Description:
Roof Trak® III is a non-skid, maintenance-free walkway/protection pad. Roof Trak III is an extruded pad made from both recycled Duro-Last® membrane and an oriented strand polyester reinforcement.
Duro-Last, Inc. manufactures the Roof Trak III Walkway Pad to provide protection in heavily traveled rooftop areas. It also provides added protection around mechanical equipment and as a separator for sleepers that support mechanical equipment. Field and laboratory testing have proven that Roof Trak III can be used in all seasons and applications.
Roof Trak III utilizes factory-attached, 4-inch wide, white membrane skirts for attachment to the field membrane by heat welding (hot-air).
Duro-Last, Inc. manufactures Roof Trak III in the colors and skirt configurations shown in the table below.
TABLE 1. ROOF TRAK III AVAILABLE COLORS AND SKIRT
CONFIGURATIONS
Sizes |
Colors |
Attachment |
|
Skirts |
|||
|
|
||
|
|
|
|
30 in. x 60 in. |
White, Tan and Gray solid colors. |
2 skirts along |
|
|
White with safety-yellow skirts. |
60-in. sides |
|
60 in. x 60 in. |
White, Tan and Gray solid colors. |
2 skirts along |
|
|
White with safety-yellow skirts. |
60-in. sides |
|
30 in. x 60 in. |
White solid color. |
Fully skirted |
|
White with safety-yellow skirts. |
along all 4 sides |
||
|
|||
|
|
|
Installation:
1.Roof Trak III attachment skirts shall be heatwelded (hot-air) to the field membrane using a 1.5-inch wide weld along the entire length of the skirt.
2.Walkway pads installed directly over field seams shall have one side unattached to allow for the inspection of field seams for warranty purposes. Following inspection, the unattached skirt must be welded to the roof membrane.
3.A 1-inch gap is required between sections of walkway pad to allow for proper water drainage.
ROOF TRAK® III WALKWAY PAD
PRODUCT DATA SHEET
Figure 1. Roof Trak III Available Sizes
TABLE 2. TYPICAL PHYSICAL PROPERTIES
Property |
Result (US) |
|
Result (metric) |
|
|
|
|
Thickness |
0.135 in. |
|
3 mm |
|
|
|
|
Weight |
0.79 lb./ft.2 |
|
3.9 kg/m2 |
|
|
|
|
Breaking Strength |
516 lb. |
|
2,296 N |
(machine direction) |
|
||
|
|
|
|
Breaking Strength |
489 lb. |
|
2,176 N |
(cross machine direction) |
|
||
|
|
|
|
|
|
|
|
Elongation |
50% |
|
50% |
(machine direction) |
|
||
|
|
|
|
|
|
|
|
Elongation |
64% |
|
64% |
(cross machine direction) |
|
||
|
|
|
|
Tear Strength |
45 lb. |
|
200 N |
(machine direction) |
|
||
|
|
|
|
|
|
|
|
Tear Strength |
71 lb. |
|
316 N |
(cross machine direction) |
|
||
|
|
|
|
|
|
|
|
Static Coefficient of |
|
0.95 |
|
Friction (Dry) |
|
||
|
|
|
|
Static Coefficient of |
|
1.19 |
|
Friction (Wet) |
|
||
|
|
|
www.duro-last.com |
1 of 1 |
800-248-0280 |
Duro-Last, “World’s Best Roof” and Roof Trak are registered marks owned by Duro-Last, Inc. Updated: 10/14/2013