Parapet Wall Vent
Description:
The Parapet Wall Vent is engineered for maximum
ventilation with pre-punched slots on the bottom along
with louvered face.
Fabricated from 24-gauge vinyl-coated metal
and pre-finished Galvalume® 14” wide and 10”
tall with a 6” Duro-Last® attached skirt.
Parapet vent provides 44.5 in2 of net free area.
Parapet ventilation area for the attic area without
vapor retarder is 1 sf (ventilation)/150 sf of attic
area.
Parapet ventilation for new construction attic
area that provides a vapor retarder is 1 sf
(ventilation) / 300 sf of attic area. See the IBC
for ventilation requirements.
Contact Duro-Last or EXCEPTIONAL® Metals to
request a color chart, samples and information
regarding custom metals and finishes.
Energy Efficiency:
LEED® and ENERGY STAR® compliant; 100%
recyclable.
Installation:
1. Install in accordance with Duro-Last detail
drawings #6010 and #6015.
2. Any deviation from the requirements set forth in
the detail drawings must be pre-approved, in
writing, by the EXCEPTIONAL Metals Technical
Department.
Warranty:
Duro-Last offers a wide range of warranty coverage for
EXCEPTIONAL Metals products when used with the
Duro-Last roofing system, including paint and finish.
Technical Services:
Product samples, detail sheets, color chips, and color
chart are available for your submittal package. For
assistance with questions or submittals, contact your
local representative or call EXCEPTIONAL Metals.
“Duro-Last” and “EXCEPTIONAL” are registered marks owned by Duro-Last Roofing, Inc. Revised 8/12/2012