DURO-LAST® METAL FASCIA SYSTEM
DATA SHEET
Description:
The Duro-Last
a perimeter detail for the Duro-Last roofing system and
as termination on rectangular penetrations. The system
consists of a bar and snap-on metal cover. The system
is listed by FM Approvals as a Class 1 perimeter
flashing with the 1.75 inch (44 mm) wide system
achieving a Class 1-990 and the 4 inch (102 mm) wide
system achieving a Class 1-825.
® Metal Fascia System may be used as
The fascia bar is fabricated from rigid exterior vinyl
with pre-punched slotted holes 6 inches (152 mm)
on center. The bar is 10 foot long and available in
two widths: 1.75 inch (44 mm) and 4 inch (102 mm).
The bar is only available in white color.
The metal cover is 10 foot long and available in
24-gauge galvalume steel with 35 stocked finishes
as well as in these specialized metals:
* .040 aluminum with Kynar finish.
* .040 aluminum with mill finish.
* 16-oz. copper.
* 24-gauge stainless steel.
* 24-gauge bonderized (paintable) steel.
Contact Duro-Last, Inc. to request a color chart,
samples and information regarding custom metals
and finishes.
Installation:
1. The 1.75 inch (44 mm) wide fascia bar must be
fastened 6 inches (152 mm) on center, maximum.
2. The 4 inch (102 mm) wide fascia bar must be
fastened 6 inches (152 mm) on center, maximum.
The fastening may be along one row of holes or
staggered along three rows.
3. It is required to leave a ¼ inch (6.3 mm) gap
between sections of the fascia bar.
4. The fascia cover should be installed so that the
joints between sections are offset a minimum of
12 inches (25 mm) from the joints between sections
of the fascia bar.
5. Adjacent sections of cover are designed to overlap.
No joint clips are required.
6. Apply Duro-Caulk® Plus along the top of the fascia
bar.
7. Refer to detail drawings 3500 and 3510 for
installation information when roof system is
mechanically attached or FA3500 and FA3510
when the roof system is fully adhered.
8. The fascia system may not be installed as a
gravel/water stop.
9. All vertical applications require Duro-Caulk Plus to
be applied on both sides of fascia bar.
Note:
Fascia bar and metal cover are ordered separately
in 10 foot lengths. They will be packaged in
cardboard tubes or wooden crates.
The cover is shipped with a protective plastic film
which should be removed prior to installation.
To clean the metal cover use soap and water (i.e.
1/3 cup laundry detergent per gallon of water).
1.75 inch (44 mm) wide Metal Fascia System
(Install per detail drawing 3500 or FA3500)
4 inch (102 mm) wide Metal Fascia System
(Install per detail drawing 3510 or FA3510)
Duro-Last: The Proven Performer®
www.duro-last.com
"Duro-Last " an d T he "World's Best Roof" are registered marks owned by Duro-La st , Inc.
34
800-248-0280
Revised: 12/15/2011