DURO-GUARD® HD ISO + EPS
FLAT AND TAPERED PANELS
Description:
®
Duro-Guard
consisting of a superior closed-cell, lightweight and
resilient expanded polystyrene (EPS) bonded to a
high-density polyisocyanurate cover board. It meets
or exceeds the requirements of ASTM C 578,
Standard Specification for Rigid, Cellular Polystyrene
Thermal Insulation.
• Top layer of ½ inch high density
polyisocyanurate provides 100 psi compressive
strength.
• Bottom layer consists of Duro-Guard EPS Type
VIII, 1.25 pcf, per ASTM C 578.
• Available in both flat and tapered panels in
order to meet thermal insulation needs as well
as provide slope for proper roof drainage.
• High thermal efficiency and maximum
durability.
• Reduces inter-ply adhesive and saves labor.
• Provides long-term thermal insulation value.
• Does not contain CFCs or HCFCs.
• Superior moisture resistance.
• 100% recyclable.
• Refer to Table 3 for physical properties.
Recommended Uses:
HD ISO + EPS is a premium insulation
Figure 1. Duro-Guard HD ISO + EPS Flat (Top Layer)
Tapered Panels:
• Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm).
o 4 ft. x 8 ft. (1220 mm x 2440 mm).
o Thickness: ½ to 6.5 inch (13 to152 mm).
• Precut cricket and saddle systems are available.
• Taper designs and shop drawings are available.
• Custom sizes are available.
• Mechanically attached Duro-Last roof systems.
• Adhered/Fully Bonded Duro-Last roof systems.
®
• Duro-Bond
roof systems.
• Metal retrofit roof systems.
Underwriters Laboratories Inc.:
Figure 2. Duro-Guard HD ISO + EPS Taper
• Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details
(www.ul.com).
Factory Mutual Global:
• Refer to FM Approval’s RoofNav for details on
FM Approved systems (www.roofnav.com).
Flat Panels:
• Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm).
o 4 ft. x 8 ft. (1220 mm x 2440 mm).
o Thickness: 1.5 to 6 inch (38 to 152 mm).
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
1 of 2 www.duro-last.com 800-248-0280
Updated: 11/4/2013
TABLE 1. TYPICAL TAPER PANEL DIMENSIONS
ID SLOPE*
A1 ⅛” per 12” 1%
A2 ⅛” per 12” 1%
A3 ⅛” per 12” 1%
A4 ⅛” per 12” 1%
C1 ¼” per 12” 2%
C2 ¼” per 12” 2%
C3 ¼” per 12” 2%
C4 ¼” per 12” 2%
E1 ½” per 12” 4%
E2 ½” per 12” 4%
E3 ½” per 12” 4%
E4 ½” per 12” 4%
* Contact Duro-Last for additional slope options.
Thickness
Panels can be formed
up to 6.5” thick.
The starting thickness
of the tapered panels
can be custom ordered
based on project
requirements.
Installation:
DURO-GUARD® HD ISO + EPS
• Duro-Guard HD ISO + EPS may be used
directly under the Duro-Last membrane.
Care should be taken to ensure that “bare”
EPS is never in direct contact with the
membrane. Refer to the appropriate DuroLast specification for slip sheet and cover
board requirements.
• Panels must be kept dry before, during and
after installation. Install only as much insulation
as can be covered the same day with
completed roofing.
• The use of multiple layers of insulation with
joints staggered a minimum of 6 inches
between layers is recommended to eliminate
thermal bridging.
• Butt panel edges together and stagger joints of
adjacent panels.
• Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than
¼ inch.
• Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck
preparation and attachment requirements.
• Precautions must be taken to ensure that new
concrete decks have fully hydrated and do not
continue to release moisture.
Panel Attachment:
• Panels may be attached to the roof deck using
mechanical fasteners or insulation adhesive. It
is acceptable to use these products in
combination.
Mechanical Attachment
• When installing multiple layers (which may
include insulation, cover boards and thermal
barriers) it is acceptable to mechanically secure
through all layers.
• Use fasteners and plates supplied by or
approved by Duro-Last, Inc.
Adhesive Attachment
• Insulation adhesive must be supplied by Duro-
Last, Inc. Refer to the adhesive’s product data
sheet for application guidelines. Acceptable
products:
®
o Duro-Grip
o Duro-Grip
o Duro-Grip
o Duro-Grip
Insta-Stik™.
®
Olybond®.
®
Millenium Weather-Tite®.
®
CR-20.
• Subsequent layers of insulation and approved
cover boards may also be attached with
insulation adhesive.
• Maximum panel dimensions are 4ft. x 4ft.
TABLE 2. TYPICAL THERMAL VALUES
THICKNESS R-Value*
(inches) (mm) TYPE VIII
1.50 38 8.8
2.00 51 10.9
2.50 64 13.0
3.00 76 15.1
3.50 89 17.2
4.00 102 19.3
4.50 114 21.4
5.00 127 23.5
5.50 140 25.6
6.00 152 27.7
* R-Value is calculated by adding the R-value of the cover
board and the R-value of Duro-Guard EPS Type VIII
together.
TABLE 3. TYPICAL PHYSICAL PROPERTIES
Property Test Method Type VIII
Density (nominal) ASTM C 303 1.25 pcf
R-Value
(per inch)
@25°F
@40°F
@75°F
Compressive Strength
(10% deformation)
Flexural Strength ASTM C 203 ≥ 30 psi
Dimensional Stability ASTM D 2126 ≤ 2.0%
Water Vapor Permeance ASTM E 96 ≤ 3.5 perm
Water Absorption ASTM C 272 ≤ 3.0%
Flame Spread ASTM E 84 20
Smoke Developed ASTM E 84 150 - 300
(Foam Core)
ASTM C 518
or
C 177
ASTM D 1621 13 – 18 psi
Storage:
• Insulation must be protected from open flame
and kept dry at all times.
• Factory applied packaging is intended only for
protection during transit. Slit or remove the
packaging to prevent accumulation of
condensation.
• Store elevated (at least 3”) and completely
covered with a weatherproof covering such as
a tarpaulin.
• Do not use panels which are wet or damaged.
Limitations:
• Duro-Last, Inc. will not be responsible or liable
for any defects or problems related to building
or roof design by others, to deficiencies in
construction, to dangerous conditions on the
job site, or to improper storage, handling or
installation by others.