Duro-Last HD ISO Plus EPS User Manual

DURO-GUARD® HD ISO + EPS
FLAT AND TAPERED PANELS
Description:
®
Duro-Guard consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS) bonded to a high-density polyisocyanurate cover board. It meets or exceeds the requirements of ASTM C 578,
Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.
Top layer of ½ inch high density polyisocyanurate provides 100 psi compressive strength.
Bottom layer consists of Duro-Guard EPS Type VIII, 1.25 pcf, per ASTM C 578.
Available in both flat and tapered panels in order to meet thermal insulation needs as well as provide slope for proper roof drainage.
High thermal efficiency and maximum durability.
Reduces inter-ply adhesive and saves labor.
Provides long-term thermal insulation value.
Does not contain CFCs or HCFCs.
Superior moisture resistance.
100% recyclable.
Refer to Table 3 for physical properties.
Recommended Uses:
HD ISO + EPS is a premium insulation
Figure 1. Duro-Guard HD ISO + EPS Flat (Top Layer)
Tapered Panels:
Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm). o 4 ft. x 8 ft. (1220 mm x 2440 mm). o Thickness: ½ to 6.5 inch (13 to152 mm).
Precut cricket and saddle systems are available.
Taper designs and shop drawings are available.
Custom sizes are available.
Mechanically attached Duro-Last roof systems.
Adhered/Fully Bonded Duro-Last roof systems.
®
Duro-Bond
roof systems.
Metal retrofit roof systems.
Underwriters Laboratories Inc.:
Figure 2. Duro-Guard HD ISO + EPS Taper
Refer to Duro-Last’s UL Listings (TGFU.R10128) for assembly details (www.ul.com).
Factory Mutual Global:
Refer to FM Approval’s RoofNav for details on FM Approved systems (www.roofnav.com).
Flat Panels:
Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm). o 4 ft. x 8 ft. (1220 mm x 2440 mm). o Thickness: 1.5 to 6 inch (38 to 152 mm).
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
1 of 2 www.duro-last.com 800-248-0280
Updated: 11/4/2013
TABLE 1. TYPICAL TAPER PANEL DIMENSIONS
ID SLOPE* A1 ” per 12” 1% A2 ” per 12” 1% A3 ” per 12” 1% A4 ” per 12” 1% C1 ¼” per 12” 2% C2 ¼” per 12” 2% C3 ¼” per 12” 2% C4 ¼” per 12” 2% E1 ½” per 12” 4% E2 ½” per 12” 4% E3 ½” per 12” 4% E4 ½” per 12” 4%
* Contact Duro-Last for additional slope options.
Thickness
Panels can be formed
up to 6.5” thick.
The starting thickness
of the tapered panels
can be custom ordered
based on project
requirements.
/4/
ast.co
800
80
Installation:
DURO-GUARD® HD ISO + EPS
Duro-Guard HD ISO + EPS may be used directly under the Duro-Last membrane. Care should be taken to ensure that “bare” EPS is never in direct contact with the membrane. Refer to the appropriate Duro­Last specification for slip sheet and cover board requirements.
Panels must be kept dry before, during and after installation. Install only as much insulation as can be covered the same day with completed roofing.
The use of multiple layers of insulation with joints staggered a minimum of 6 inches between layers is recommended to eliminate thermal bridging.
Butt panel edges together and stagger joints of adjacent panels.
Boards must be neatly fitted to roof deck and around penetrations with no gaps greater than ¼ inch.
Refer to the appropriate Duro-Last roof system specification and detail drawings for deck preparation and attachment requirements.
Precautions must be taken to ensure that new concrete decks have fully hydrated and do not continue to release moisture.
Panel Attachment:
Panels may be attached to the roof deck using mechanical fasteners or insulation adhesive. It is acceptable to use these products in combination.
Mechanical Attachment
When installing multiple layers (which may include insulation, cover boards and thermal barriers) it is acceptable to mechanically secure through all layers.
Use fasteners and plates supplied by or approved by Duro-Last, Inc.
Adhesive Attachment
Insulation adhesive must be supplied by Duro- Last, Inc. Refer to the adhesive’s product data sheet for application guidelines. Acceptable products:
®
o Duro-Grip o Duro-Grip o Duro-Grip o Duro-Grip
Insta-Stik™.
®
Olybond®.
®
Millenium Weather-Tite®.
®
CR-20.
Subsequent layers of insulation and approved cover boards may also be attached with insulation adhesive.
Maximum panel dimensions are 4ft. x 4ft.
TABLE 2. TYPICAL THERMAL VALUES
THICKNESS R-Value*
(inches) (mm) TYPE VIII
1.50 38 8.8
2.00 51 10.9
2.50 64 13.0
3.00 76 15.1
3.50 89 17.2
4.00 102 19.3
4.50 114 21.4
5.00 127 23.5
5.50 140 25.6
6.00 152 27.7
* R-Value is calculated by adding the R-value of the cover
board and the R-value of Duro-Guard EPS Type VIII together.
TABLE 3. TYPICAL PHYSICAL PROPERTIES
Property Test Method Type VIII
Density (nominal) ASTM C 303 1.25 pcf
R-Value
(per inch)
@25°F @40°F @75°F
Compressive Strength
(10% deformation)
Flexural Strength ASTM C 203 30 psi
Dimensional Stability ASTM D 2126 2.0%
Water Vapor Permeance ASTM E 96 3.5 perm
Water Absorption ASTM C 272 3.0%
Flame Spread ASTM E 84 20
Smoke Developed ASTM E 84 150 - 300
(Foam Core)
ASTM C 518
or
C 177
ASTM D 1621 13 – 18 psi
Storage:
Insulation must be protected from open flame and kept dry at all times.
Factory applied packaging is intended only for protection during transit. Slit or remove the packaging to prevent accumulation of condensation.
Store elevated (at least 3”) and completely covered with a weatherproof covering such as a tarpaulin.
Do not use panels which are wet or damaged.
Limitations:
Duro-Last, Inc. will not be responsible or liable for any defects or problems related to building or roof design by others, to deficiencies in construction, to dangerous conditions on the job site, or to improper storage, handling or installation by others.