DURO-GUARD® EPS TYPES II AND VIII
FLAT AND TAPERED PANELS
Description:
®
Duro-Guard
insulations consisting of a superior closed-cell,
lightweight and resilient expanded polystyrene (EPS).
They meet or exceed the requirements of ASTM C
578, Standard Specification for Rigid, Cellular
Polystyrene Thermal Insulation.
• Available in both flat and tapered panels in
order to meet thermal insulation needs as well
as provide slope for proper roof drainage.
• Provides long-term thermal insulation value.
• Does not contain CFCs or HCFCs.
• Superior moisture resistance.
• 100% recyclable.
• Available in two densities per ASTM C 578:
o Type II, 1.50 pcf.
o Type VIII, 1.25 pcf.
• Refer to Table 3 for physical properties.
Recommended Uses:
• Mechanically attached Duro-Last roof systems.
• Adhered/Fully Bonded Duro-Last roof systems.
• Duro-Bond
• Metal retrofit roof systems.
EPS Type II and Type VIII are premium
®
roof systems.
Figure 1. Duro-Guard EPS Types II and VIII Flat
Tapered Panels:
• Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm).
o 4 ft. x 8 ft. (1220 mm x 2440 mm).
o Thicknesses: 0 to 40 inch (0 to 1016 mm).
• Precut cricket and saddle systems are available.
• Taper designs and shop drawings are
available.
• Custom sizes are available.
Underwriters Laboratories Inc.:
• Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details
(www.ul.com).
Factory Mutual Global:
• Refer to FM Approval’s RoofNav for details on
FM Approved systems (www.roofnav.com).
Flat Panels:
• Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm).
o 4 ft. x 8 ft. (1220 mm x 2440 mm).
o Thickness: Up to 40 inch (1016 mm).
o Custom cut “flute filler” for metal roofs is available.
* Contact Duro-Last for additional slope options.
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
1 of 2 www.duro-last.com 800-248-0280
Updated: 11/4/2013
Figure 2. Duro-Guard EPS Types II and VIII Taper
TABLE 1. TYPICAL TAPER PANEL DIMENSIONS
ID SLOPE* Thickness
A1 ⅛” per 12” 1%
A2 ⅛” per 12” 1%
A3 ⅛” per 12” 1%
A4 ⅛” per 12” 1%
C1 ¼” per 12” 2%
C2 ¼” per 12” 2%
C3 ¼” per 12” 2%
C4 ¼” per 12” 2%
E1 ½” per 12” 4%
E2 ½” per 12” 4%
E3 ½” per 12” 4%
E4 ½” per 12” 4%
EPS panels can be formed
up to 40” thick.
The starting thickness of
the tapered panels can be
custom ordered based on
project requirements.
DURO-GUARD® EPS TYPES II AND VIII
Installation:
• Duro-Guard EPS panels and Duro-Last
membrane must never be in direct contact.
Refer to the appropriate Duro-Last specification
for slip sheet and cover board requirements.
• Panels must be kept dry before, during and
after installation. Install only as much insulation
as can be covered the same day with
completed roofing.
• The use of multiple layers of insulation with
joints staggered a minimum of 6 inches
between layers is recommended to eliminate
thermal bridging.
• Butt panel edges together and stagger joints of
adjacent panels.
• Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than
¼ inch.
• Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck
preparation and attachment requirements.
• Precautions must be taken to ensure that new
concrete decks have fully hydrated and do not
continue to release moisture.
Panel Attachment:
• Panels may be attached to the roof deck using
mechanical fasteners or insulation adhesive. It
is acceptable to use these products in
combination.
Mechanical Attachment
• When installing multiple layers (which may
include insulation, cover boards and thermal
barriers) it is acceptable to mechanically secure
through all layers.
• Use fasteners and plates supplied by or
approved by Duro-Last, Inc.
Adhesive Attachment
o Insulation adhesive must be supplied by
Duro-Last, Inc. Refer to the adhesive’s
product data sheet for application guidelines.
Acceptable products:
®
o Duro-Grip
o Duro-Grip
o Duro-Grip
o Duro-Grip
Insta-Stik™.
®
Olybond®.
®
Millenium Weather-Tite®.
®
CR-20.
• Subsequent layers of insulation and approved
cover boards may also be attached with
insulation adhesive.
• Maximum panel dimensions are 4ft. x 4ft.
Storage:
• Insulation must be protected from open flame
and kept dry at all times.
• Factory applied packaging is intended only for
protection during transit. Slit or remove the
packaging to prevent accumulation of
condensation.
TABLE 2. TYPICAL THERMAL VALUES
THICKNESS* R-Value
inches mm TYPE II TYPE VIII
1.00 25 4.5 4.2
1.50 38 6.7 6.3
2.00 51 9.0 8.4
2.50 64 11.2 10.5
3.00 76 13.5 12.6
3.50 89 15.7 14.7
4.00 102 17.0 16.8
4.50 114 20.2 18.9
5.00 127 22.5 21
5.50 140 24.7 23.1
6.00 152 27.0 25.2
* Contact Duro-Last for additional thickness options.
TABLE 3. TYPICAL PHYSICAL PROPERTIES
Property Test Method Type II
Density
(nominal)
R-Value
(per inch)
@25°F
@40°F
@75°F
Compressive
Strength
(10% deformation)
Flexural Strength ASTM C 203 ≥ 35 psi
Dimensional
Stability
Water Vapor
Permeance
Water Absorption ASTM C 272 ≤ 3.0%
Flame Spread ASTM E 84 20
Smoke Developed ASTM E 84 150 - 300
ASTM C 303 1.50 pcf
ASTM C 518
or
C 177
ASTM
D 1621
ASTM
D 2126
ASTM E 96 ≤ 3.5 perm
4.76
4.55
4.17
15 – 21
psi
Type
VIII
1.25 pcf
4.55
4.25
3.92
13 – 18
psi
≥ 30 psi
≤ 2.0%
• Store elevated (at least 3”) and completely
covered with a weatherproof covering such as
a tarpaulin.
• Do not use panels which are wet or damaged.
Limitations:
• Duro-Last, Inc. will not be responsible or liable
for any defects or problems related to building
or roof design by others, to deficiencies in
construction, to dangerous conditions on the
job site, or to improper storage, handling or
installation by others.