DURO-GUARD® EPS NAIL BASE
Description:
Duro-Guard
®
EPS Nail Base is a premium composite
insulation consisting of a superior closed-cell,
lightweight and resilient expanded polystyrene (EPS)
bonded to oriented strand board (OSB) or plywood.
The EPS board meets or exceeds the requirements
of ASTM C 578, Standard Specification for Rigid,
Cellular Polystyrene Thermal Insulation.
• Provides long-term thermal insulation value.
• A superior combination of high insulating
properties and a nailable surface.
• Incorporates APA-TECO Rated Exposure 1
OSB.
• Also available with plywood.
• Does not contain CFCs or HCFCs.
• Superior moisture resistance.
• Duro-Guard EPS Nail Base is not a
structural panel, and is suitable only for
installation over fully supported structural
decks.
• Available in two densities per ASTM C 578:
o Type II, 1.50 pcf.
o Type VIII, 1.25 pcf.
• Refer to Table 1 for physical properties.
Recommended Uses:
®
• Underlayment for Exceptional
Metals standing
seam metal roofs.
• Mechanically attached Duro-Last roof systems.
®
• Duro-Bond
roof systems.
• Metal retrofit roof systems.
Underwriters Laboratories Inc.:
• Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details
(www.ul.com).
Factory Mutual Global:
• Refer to FM Approval’s RoofNav for details on
FM Approved systems (www.roofnav.com).
Figure 1. Duro-Guard EPS Nail Base
Flat Panels:
• Typical sizes:
o 4 ft. x 4 ft. (1220 mm x 1220 mm).
o 4 ft. x 8 ft. (1220 mm x 2440 mm).
o Thickness: 1.5 to 11.75 inch (38 – 304 mm).
• Custom width, length and thickness available.
Contact Duro-Last with special requests.
• Refer to Table 1 for typical R-values.
TABLE 1. TYPICAL THERMAL VALUES
THICKNESS* R-Value
inches mm TYPE II
2.00 51 6.4
3.00 76 10.5
4.00 102 14.1
5.00 127 18.2
6.00 152 21.8
7.75 196 28.5
9.75 247 36.2
11.75 298 43.9
* Contact Duro-Last for additional thickness options
.
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
1 of 2 www.duro-last.com 800-248-0280
Updated: 11/4/2013
DURO-GUARD® EPS NAIL BASE
Installation:
• Duro-Guard EPS Nail Base may be used
directly under the Duro-Last membrane.
Care should be taken to ensure that “bare”
EPS is never in direct contact with the
membrane. Refer to the appropriate DuroLast specification for slip sheet and cover
board requirements.
• Panels must be kept dry before, during and
after installation. Install only as much insulation
as can be covered the same day with
completed roofing.
• The use of multiple layers of insulation with
joints staggered a minimum of 6 inches
between layers is recommended to eliminate
thermal bridging.
• Butt panel edges together and stagger joints of
adjacent panels.
• Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than
¼ inch.
• Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck
preparation and attachment requirements.
• Precautions must be taken to ensure that new
concrete decks have fully hydrated and do not
continue to release moisture.
Panel Attachment:
• Panels may be attached to the roof deck using
mechanical fasteners or insulation adhesive. It
is acceptable to use these products in
combination.
Mechanical Attachment
• When installing multiple layers (which may
include insulation, cover boards and thermal
barriers) it is acceptable to mechanically secure
through all layers.
• Use fasteners intended for use with this
product and that are supplied by or approved
by Duro-Last, Inc.
Adhesive Attachment
• Insulation adhesive must be supplied by Duro-
Last, Inc. Refer to the adhesive’s product data
sheet for application guidelines. Acceptable
products:
®
o Duro-Grip
o Duro-Grip
o Duro-Grip
o Duro-Grip
Insta-Stik™.
®
Olybond®.
®
Millenium Weather-Tite®.
®
CR-20.
• Subsequent layers of insulation and approved
cover boards may also be attached with
insulation adhesive.
• Maximum panel dimensions are 4ft. x 4ft.
TABLE 2. TYPICAL PHYSICAL PROPERTIES (FOAM CORE)
Property
Density
(nominal)
R-Value
(per inch)
@25°F
@40°F
@75°F
Compressive
Strength
(10% deformation)
Flexural Strength
Dimensional
Stability
Water Vapor
Permeance
Water Absorption
Flame Spread
Smoke Developed
Test
Method
ASTM
C 303
ASTM
C 518
or
C 177
ASTM
D 1621
ASTM
C 203
ASTM
D 2126
ASTM E 96 ≤ 3.5 perm
ASTM
C 272
ASTM E 84
ASTM E 84
Type II Type VIII
1.50 pcf 1.25 pcf
4.76
4.55
4.17
15 – 21
psi
≥ 35 psi ≥ 30 psi
≤ 2.0%
≤ 3.0%
20
150 - 300
4.55
4.25
3.92
13 – 18
psi
Storage:
• Insulation must be protected from open flame
and kept dry at all times.
• Factory applied packaging is intended only for
protection during transit. Slit or remove the
packaging to prevent accumulation of
condensation.
• Store elevated (at least 3”) and completely
covered with a weatherproof covering such as
a tarpaulin.
• Do not use panels which are wet or damaged.
Limitations:
• Duro-Last, Inc. will not be responsible or liable
for any defects or problems related to building
or roof design by others, to deficiencies in
construction, to dangerous conditions on the
job site, or to improper storage, handling or
installation by others.
m
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
2of 2www.duro-l
Updated: 11
-248-02
2013