Duro-Last EPS Flute Fill Combo User Manual

DURO-GUARD® EPS FLUTE FILL COMBO
Description:
Duro-Guard insulation consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS). It meets or exceeds the requirements of ASTM C 578, Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.
EPS Flute Fill Combo can be cut to fit virtually all types of steel deck and metal roof profiles, thus elimimating any need for a separate flute filler. It can be ordered with a polyester facer or fire rated (FR) coated-glass fiber mat facer.
Benefits:
FR facer helps to achieve UL class A roof
assembly over noncombustible decks. Refer to UL listings for maximum incline.
Both facer types eliminate the need for a
slip sheet.
Shiplap joints help prevent thermal bridging.
High thermal efficiency and maximum durability.
Reduces inter-ply adhesive and saves labor.
Provides long-term thermal insulation value.
Does not contain CFCs or HCFCs.
Superior moisture resistance.
100% recyclable.
Available in three densities per ASTM C 578:
o Type I, 1.00 pcf. o Type VIII, 1.25 pcf. o Type II, 1.50 pcf.
Refer to Table 2 for physical properties.
Recommended Uses:
Mechanically attached Duro-Last
Duro-Bond
Metal retrofit roof systems.
Refer to the appropriate installation specification for the above uses.
Underwriters Laboratories Inc.:
Refer to Duro-Last’s UL Listings (TGFU.R10128)
for assembly details (www.ul.com).
Factory Mutual Global:
Refer to FM Approval’s RoofNav for details on
FM Approved systems (www.roofnav.com).
®
EPS Flute Fill Combo is a premium
®
roof systems.
®
roof systems.
Duro-Last, Duro-Bond, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
Figure 1. Duro-Guard EPS Flute Fill Combo with FR facer
Flat Panels:
Typical sizes:
o 4 ft. x 8 ft. (1,220 mm x 2,440 mm). o Thickness (overall): Up to 8 inches (203 mm). o Thickness (above top flute): 1-1/2 inches
(38 mm) minimum.
Installation:
Duro-Guard EPS Flute Fill Combo may be
used directly under the Duro-Last membrane with either polyester or FR facer. Care should be taken to ensure that “bare” EPS is never in direct contact with the membrane. Refer to the appropriate Duro-Last specification for slip sheet and cover board requirements.
Panels must be kept dry before, during and after
installation. Install only as much insulation as can be covered the same day with completed roofing.
1 of 2 www.duro-last.com 800-248-0280
Created: 01/22/2014
/
ast.co
800
80
DURO-GUARD® EPS FLUTE FILL COMBO
The use of multiple layers of insulation with joints
staggered a minimum of 6 inches between layers is recommended to eliminate thermal bridging.
Abut panel edges together and stagger joints of
adjacent panels.
Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than ¼ inch.
Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck preparation and attachment requirements.
Panel Attachment:
Panels may be attached to the roof deck using
mechanical fasteners only.
Mechanical Attachment
When installing multiple layers (which may
include insulation, cover boards and thermal barriers) it is acceptable to mechanically secure through all layers.
Only use fasteners and plates supplied by, or
approved by, Duro-Last, Inc.
Storage:
Insulation must be protected from open flame and
kept dry at all times.
Factory applied packaging is intended only for
protection during transit. Slit or remove the packaging to prevent accumulation of condensation.
Store elevated (at least 3 inches) and completely
covered with a weatherproof covering such as a tarpaulin.
Do not use panels which are wet or damaged.
Limitations:
Duro-Last, Inc. will not be responsible or liable for
any defects or problems related to building or roof design by others, to deficiencies in construction, to dangerous conditions on the job site, or to improper storage, handling or installation by others.
TABLE 1. TYPICAL THERMAL VALUES
Thickness* R-Value
Inches mm Type I Type VIII Type II
1.50 38 6.1 6.3 6.7
2.00 51 8.2 8.4 9.0
2.50 64 10.2 10.5 11.2
3.00 76 12.3 12.6 13.5
3.50 89 14.3 14.7 15.7
4.00 102 16.4 16.8 17.0
4.50 114 18.4 18.9 20.2
5.00 127 20.5 21.0 22.5
5.50 140 22.5 23.1 24.7
6.00 152 24.6 25.2 27.0
6.50 165 26.6 27.3 29.2
7.00 177 28.7 29.4 31.5
7.50 190 30.7 31.5 33.7
8.00 203 32.8 33.6 36.0
* Contact Duro-Last for additional thickness options.
TABLE 2. TYPICAL PHYSICAL PROPERTIES
Property
Density
(nominal)
R-Value
(per inch)
@40°F @75°F
Compressive
Strength
(10%
deformation)
Flexural Strength
Dimensional
Stability
Water Vapor
Permeance
Water Absorption
Test
Method
ASTM C 303
ASTM C 518
or
C 177
ASTM
D 1621
ASTM D 203
ASTM
D 2126
ASTM E 96
ASTM C 272
Type I
1.00 pcf 1.25 pcf 1.50 pcf
4.17
3.85
10 – 14
psi
25 – 30
psi
2.0% 2.0% 2.0%
2.0 – 5.0 perm
< 4.0% < 3.0% < 3.0%
Type
VIII
4.25
3.92
13 – 18
psi
32 – 38
psi
1.5 – 3.5 perm
Type II
4.55
4.17
15 – 21
psi
40 – 50
psi
1.0 – 3.5 perm
m