ELECTRICAL REQUIREMENTS
H. WEISS MACHINERY & SUPPLY
H. WEISS MACHINERY & SUPPLY
PHONE: (718) 605-0395 - www.hweiss.com
TIMER ADJUSTMENT
Connect the MF-12 to a 30 amp power supply. (208­230 volts – 60 cycle). The MF12 uses 208 – 230 volt single phase. To wire to 208-230 volt single phase, the green lead is ground and the white and black leads are power. It is suggested that the unit be permanently wired into a 30 amp disconnect box fitted with 30 amp slow blow fuses.
MF-12 AS A BENCH TOOL
To use your work bench as a welding table, set the MF-12 alongside or on top of the work bench. Cover the bench top with a copper sheet (.025 inch) which will act as a permanent ground when the duct work is placed on the table top. Attach the MF-12 ground clamp to the duct work or copper bench top. The Clip Pins will quickly weld every time with no burn marks or wasted pins due to misfires.
BRING MF-12 TO THE WORK
Where duct is too large to put on a bench, snap the ground clamp onto the duct and secure the insula­tion quickly by welding the Clip Pins inside or outside of the ducts as required. Eliminate the heat mark on the duct using the simple “heat sink” supplied on the opposite side of the weld.
SERVICE
The MF-12 has been designed and built to withstand rugged shop usage. The Indicator lights on the front panel will help you to diagnose minor problems. If your MF-12 fails to operate follow this simple procedure to find the defective component.
1. Pull the trigger and watch the lights. The green light (24 volts) and then the red light (220 volts) should flash on and off.
2. If only the green light comes on, go to step 4.
The timer dial facing you on the front panel of the unit, determines the duration of the weld cycle. For maximum efficiency of the unit, the weld cycle should be set for the shortest length of time necessary to provide a good weld. An excessive amount of time does not improve the weld. On the contrary, the resulting weld may not be an acceptable one. It is recommended that at the start of a production run, using a given length of pin with a given gauge of metal, the opera­tor take a few moments to determine the minimum timer setting to perform the job and leave the timer at that point. NOTE: There is a common misconception that the longer the weld time, the stronger the weld. This is not true. It is important that you follow the above instructions for maintaining the minimum weld time.
"HEAT SINK"
Included with your MF-12 is a simple “heat sink” tool that looks somewhat like a cookie cutter. This tool, when placed behind the point of weld on bare metal, will eliminate any mark on the metal by dissipating the heat generated from the point of the weld. The use of a copper sheet on the work bench will also eliminate this mark.
MAINTENANCE
The MF-12 has been designed and built to withstand rugged shop. Constant, trouble-free operation is as­sured with a minimum of maintenance. The GUN TIP, the GROUND CLAMP and all CABLE CONNECTIONS should be kept clean to maintain a good electrical contact. Wire brush the parts to remove any oxida­tion or adhesive that may have accumulated during the fastening operation.
INSTALLING CLIP PINS
Clip Pins are welded as easily as "A", "B", "C".
"A"
Position the Clip pin on the Magnetic tip of hand gun.
3. If neither light comes on, press the WELD CYCLE TEST switch on the front panel.
A. If both lights flash and the transformers do not
hum go to step 5.
B. If both lights flash and the transformers hum,
the problem is either a bad trigger switch or bad switch cable.
C. If only the green light flashes, go to step 4 D. If neither light flashes, replace 24 volt trans-
former.
4. Replace the weld activator.
5. The problem is probably a bad weld transformer.
Call technical service for further assistance.
(1-800-899-3876)
"B"
Press down through the insu­lation, twist the gun, and pull the trigger. Do not release the trigger until the timer cycle has ended.
"C"
The Clip Pins are permanently welded in position flush with the insulation.