DURASTAR.COM
FORM NO. CDS-224
1
SPECIFICATION SHEET 
DRAEF Series 
CASED COILS FOR GAS FURNACES
PRODUCT FEATURES 
• Durastar Indoor Furnace cased coils are designed for use with Durastar 
outdoor units and are available for vertical upflow or downflow, and horizontal 
left or horizontal right airflow. When matched with Durastar outdoor units, the 
coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 
60,000 BTU/HR [17.6 kW]. 
• Constructed of aluminum fins bonded to internally grooved aluminum tubing. 
• Coils are tested at the factory with an extensive refrigerant leak check. 
• Coils have copper sweat refrigerant connections. 
• Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate drain connections  
for ease of connection. 
• Chatleff metering device connections, at inlet and outlet of TXV and equalizer 
connections. 
• Condensate drain pan is constructed of high grade, heat resistant,  
corrosion free thermal-set material. 
• Compatible with Germicidal Light System (UV resistant) 
• Bi-Directional airflow eliminates the need to switch any internal components 
from horizontal left to right. 
• Unique drain pan design maximizes application flexibility and  
condensate removal. 
• N-Coil design maximizes performance and minimizes height  
required at installation. 
• Coils are AHRI certified for system application.
AIRFLOW CAPACITY: 
600-1,900 CFM [283-897 L/s] 

DURASTAR.COM
2
DRAEF Series
TABLE OF CONTENTS 
Model Number Identification ............................................................................3 
Coil Specifications ......................................................................................4-5 
Coil Dimensions and Weights........................................................................6-7 
Accessories ................................................................................................8-9 
Limited Warranty ..........................................................................................10

DURASTAR.COM
3
Model I.D. 
DRAEF Series
DR  A  E  F  24  17  S  T   A  M CC A 
                                                                         Minor Series**
                                                               A - 1st Design 
                                                                         Casing
                                                               CC = Cased Coil 
                                                                         Orientation
                                                               M = Multiposition 
                                                               U = Upflow/Vertical 
                                                               H = Horizontal 
                                                                         Major Series
                                                               A - 1st Design 
                                                               Metering Device  
                                                               T = TVX 
                                                               Efficiency 
                                                               S = Standard Efficiency 
                                                               M = Mid Efficiency 
                                                               H = High Efficiency 
Width 
                                                               14 = 14" 
                                                               17 = 17.5" 
                                                               21 = 21" 
                                                               24 = 24.5" 
                                                               Capacity 
                                                               24 – 2 Ton 
                                                               36 – 3 Ton 
                                                               48 – 4 Ton 
                                                               60 – 5 Ton 
                                                               Type 
                                                               F = Furnace Coil 
                                                               H = Air Handler Coil 
                                                               Product Category 
                                                               E = Evaporator Coi 
                                                               A = 410A 
                                                               Brand 
                                                               Durastar 
  [  ] Designates Metric Conversions
Model Number Identification
MODELS AVAILABLE
DRAEF2414STAMCCA 
DRAEF2417STAMCCA 
DRAEF3617STAMCCA 
DRAEF3621MTAMCCA 
DRAEF3621STAMCCA 
DRAEF4821MTAMCCA 
DRAEF4821STAMCCA 
DRAEF6021STAMCCA 
DRAEF6024STAMCCA

DURASTAR.COM
4
Coil Specifications 
DRAEF Series
Table 1: Coil Specifications/Airflow Pressure Drop
Coil 
Model 
DRAEF
Approx. 
Design Cooling 
 Air Flow 
Range CFM 
[L/s]
Face 
Area 
Sq. Ft. 
[m
2
]
Fins 
Per 
Inch / 
Rows 
Deep
Width
Nominal 
Capacity
Wet Coil Static Pressure Drop (Inches W.C.) [kPa] @ CFM [L/s] – (Coil Only)
600 
[283]
700 
[330]
800 
[378]
900 
[425]
1000 
[472]
1100 
[519]
1200 
[566]
1300 
[614]
1400 
[661]
1500 
[708]
1600 
[755]
1700 
[802]
1800 
[850]
1900 
[897]
2414STAM
600/900 
[283/425]
4.56 
[0.42]
16/2 14
1.5 – 2
0.1650.2090.2620.325——————————
2417STAM
600/900 
[283/425]
4.56 
[0.42]
16/2
17
0.1200.1570.1990.246——————————
3617STAM
700/1300 
[330/614]
5.70 
[0.52]
16/2
2.5 – 3
0.1130.1450.1810.2220.2660.3150.368———————
3621STAM
700/1300 
[330/614]
5.70 
[0.52]
16/2
21
0.1130.1450.1810.2220.2660.3150.368———————
3621MTAM
700/1300 
[330/614]
8.55 
[0.79]
16/2 0.0620.0860.1120.1400.1700.2020.236———————
4821MTAM
1100/1800 
[519/850]
7.60 
[0.70]
13/3
3.5 – 4
0.106 0.125 0.146 0.169 0.194 0.221 0.251 0.282 0.315 0.350 0.386 0.425 0.466 —
4821STAM
1100/1800 
[519/850]
8.55 
[0.79]
16/2 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 0.349 0.391 0.434 0.480 0.527
6021STAM
1400/1600 
[661/755]
7.60 
[0.70]
13/3 2 – 5 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 — —
6024STAM
1400/1800 
[661/755]
9.98 
[0.93]
14/3 24 5 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 —
[  ] Designates Metric Conversions

DURASTAR.COM
5
Coil Specifications 
DRAEF Series
Table 1: Coil Specifications/Airflow Pressure Drop (con’t.)
Coil 
Model 
DRAEF
Approx. 
Design Heating 
 Air Flow 
Range CFM 
[L/s]
Face 
Area 
Sq. Ft. 
[m
2
]
Fins 
Per 
Inch / 
Rows 
Deep
Width
Nominal 
Capacity
Dry Coil Static Pressure Drop (Inches W.C.) [kPa] @ CFM [L/s] – (Coil-Only)
600 
[283]
700 
[330]
800 
[378]
900 
[425]
1000 
[472]
1100 
[519]
1200 
[566]
1300 
[614]
1400 
[661]
1500 
[708]
1600 
[755]
1700 
[802]
1800 
[850]
1900 
[897]
2414STAM
600/1600 
[283/755]
4.56 
[0.42]
16/2 14
1.5 – 2
0.118 0.118 0.145 0.176 0.210 0.247 0.288 0.332 0.379 0.429 0.483 — — —
2417STAM
600/1500 
[283/707]
4.56 
[0.42]
16/2
17
0.1160.1160.1510.1900.2350.2840.3380.3970.4610.530————
3617STAM
600/1600 
[283/755]
5.70 
[0.52]
16/2
2.5 – 3
0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 — — —
3621STAM
600/1600 
[283/755]
5.70 
[0.52]
16/2
21
0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 — — —
3621MTAM
600/1900 
[283/896]
8.55 
[0.79]
16/2 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353
4821MTAM
600/1900 
[283/896]
7.60 
[0.70]
13/3
3.5 – 4
0.043 0.043 0.053 0.066 0.080 0.096 0.115 0.135 0.158 0.182 0.208 0.237 0.267 0.299
4821STAM
600/1900 
[283/896]
8.55 
[0.79]
16/2 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353
6021STAM
600/1900 
[283/896]
7.60 
[0.70]
13/3 2 – 5 0.080 0.080 0.092 0.106 0.121 0.136 0.153 0.171 0.190 0.211 0.232 0.254 0.278 0.302
6024STAM
600/1900 
[283/896]
9.98 
[0.93]
14/3 24 5 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337
Important Note: Gas furnace heating CFM can exceed the design cooling CFM. Ductwork and coil selection must accommodate the higher of the cooling or gas heating CFM to prevent furnace limit tripping, 
excessive noise, and coil freeze-up. 
[  ] Designates Metric Conversions

DURASTAR.COM
6
Coil Dimensions and Weights 
DRAEF Series
Table 2: Coil Dimensions and Weights
FRONT VIEW
SIDE VIEW
FIGURE 1: DIMENSIONS UNCASED
[  ] Designates Metric Conversions
Coil 
Model 
DRAEF
Connections
Uncased Coil Dimensions 
(in) [mm]
Weight
Sweat (in.) [mm]
Liquid Suction
AB
Coil Weight 
(lbs.) [Kg.]
Shipping Weight 
(lbs.) [Kg.]
I.D. I.D.
2414ST
3
/8 [9.53]
3
/4 [19.05] 213/4 88[552] 127/8 [327]  43 [19]   47 [21]
2417ST
3
/8 [9.53]
3
/4 [19.05] 153/8 88[390] 163/8 [416]  43 [19]   48 [22]
3617ST
3
/8 [9.53]
3
/4 [19.05] 183/4 88[476] 163/8 [416]  49 [22]  54 [24]
3621ST
3
/8 [9.53]
3
/4 [19.05] 183/4 88[476] 197/8 [505]  51 [23]  60 [27]
3621MT/4821ST
3
/8 [9.53]
3
/4 [19.05] 265/8 88[676] 197/8 [505]  71 [32]  78 [35]
4821MT/6021ST
3
/8 [9.53]
7
/8 [22.23] 335/8 88[838] 197/8 [505]  76 [34]  86 [39]
6024ST
3
/8 [9.53]
3
/4 [19.05] 3015/16 [786] 233/8 [594] 100 [45] 108 [48]
*The 14 inch, 2 ton DRAEF coil (2414) is part of the “N-Coil” design series, even though the coil shape resembles an “A” coil design. 
(TXV SHOWN)
(TXV SHOWN)
(EEV SHOWN)
1
/8
[3.1 mm]
11
/16
4
[119 mm]
13
/16 [46 mm]
1
11
1
/16 [42.8 mm]
5
1
/16
[33.3 mm]
SUCTION
TUBE
7
/16
3
5
[11.1 mm]
11
/16 [17.4 mm]
/8 
[137 mm]
LIQUID 
TUBE
9
3
/16
[90.4 mm]
213/8 [543 mm]

53/8
[136.5 mm]
SUCTION LINE
LIQUID LINE
1
13
/16 [46 mm]
2
1
/4 [57.1 mm]
1
1
/4
[31.7 mm]
7
/16
[11.1 mm]
5
15
/16 
[150.8 mm]
4
1
/8
[104.7 mm]
1
7
/16
[36.5 mm]
21
11
/16
[550.8 mm]
PRIMARY DRAIN 
3
/4 N.P.T. (VERTICAL) 
PRIMARY DRAIN 
/4 N.P.T. 
(VERTICAL & 
HORIZONTAL)  
SECONDARY DRAIN 
3
/4 N.P.T. (VERTICAL) 
NOTE: 
FLANGES ARE 
PROVIDED 
FOR FIELD 
INSTALLATION
 1
/2 [12.7 mm]
FRONT VIEW
SIDE VIEW
FIGURE 1: DIMENSIONS CASED
➀ Casing top and bottom openings are the same dimensions. 
[  ] Designates Metric Conversions
PLENUM WIDTH
Coil Dimensions and Weights 
DRAEF Series
Table 2: Coil Dimensions and Weights
Coil 
Model 
DRAEF
Connections
Cased Coil Dimensions 
(in) [mm]
Weight
Sweat (in.) [mm]
Liquid Suction
ABC
Coil Weight 
(lbs.) [Kg.]
Shipping Weight 
(lbs.) [Kg.]
I.D. I.D.
2414ST
3
/8 [9.53]
3
/4 [19.05] 14 1/2[356] 21 1/2[533] 233/16 [584]  43 [19]   47 [21]
2417ST
3
/8 [9.53]
3
/4 [19.05] 171/2 [445] 141/2 [368] 201/2 [508]  43 [19]   48 [22]
3617ST
3
/8 [9.53]
3
/4 [19.05] 171/2 [445] 177/8 [454] 201/2 [508]  49 [22]  54 [24]
3621ST
3
/8 [9.53]
3
/4 [19.05] 21 1/2[533] 171/2 [445] 201/2 [508]  51 [23]  60 [27]
3621MT/4821ST
3
/8 [9.53]
3
/4 [19.05] 21 1/2[533] 257/8 [657] 287/8 [711]  71 [32]  78 [35]
4821MT/6021ST
3
/8 [9.53]
7
/8 [22.23] 21 1/2[533] 327/8 [813] 341/2 [876]  76 [34]  86 [39]
6024ST
3
/8 [9.53]
3
/4 [19.05] 241/2 [622] 301/4 [768] 321/2 [826] 100 [45] 108 [48]
*The 14 inch, 2 ton DRAEF coil (2414) is part of the “N-Coil” design series, even though the coil shape resembles an “A” coil design. 
197/8
[505 mm]
A MINUS ONE INCH ➀

DURASTAR.COM
8
Accessories 
DRAEF Series
Table 3: Coil Application 
Coils can be matched to heating products as listed in table below.
Coil Model DRAEF
Furnace Width (In.) (mm)
Oil
Gas
2414ST/2417ST — 14  [356]
2417ST/3617ST 17
1
/2 [431]
171/2 [444]
14  [356]
3621ST/3621MT/4821ST/6021ST 21  [533]
21  [533]
171/2 [444]
6024ST 24
1
/2 [622]
241/2 [622]
21  [533]
2414S
RXHH-A01
2417M/2421M/3617S/
3621S/2421H
RXHH-A03
3621M/3624M/
4821S/4824S
RXHH-A04
Coil Model Horizontal Adapter Kit Model No.
2417S
RXHH-A02
3624H/4824H/
6024S/6024H
RXHH-A05
3621H/4821M/
6021S/6021M
RXHH-A06
Table 4: Horizontal Adapter Kit Model No.
Accessories 
• PLENUM ADAPTER ACCESSORY 
RXBA-AE 
This plenum adapter accessory is for use with the 241/2" wide 
cased indoor cooling and heat pump coils. This allows a 241/2" 
wide cased coil to be installed on a 28" wide oil furnace. This is a 
field-installed accessory only. 
• RXBA-AC (Upflow/Horizontal) 
These plenum adapter accessories are for use when a cooling 
coil is matched with a gas furnace of one smaller size. 
• HORIZONTAL ADAPTER KIT RXHH 
This horizontal adapter kit is used to convert a upflow or downflow 
only models to horizontal flow. See following table to order the 
proper horizontal adapter kit.
AIR FLOW 
HORIZONTAL-DUAL 
DIRECTION
FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION
 R   X   B   C   —   D  14   I 
                                                         INSULATION
                                                 I = Insulated 
                                                 Blank = Uninsulated 
                                                         CABINET WIDTH
                                                 14 = 14" [356 mm] 
                                                 17 = 17.5" [444 mm] 
                                                 21 = 21" [533 mm] 
                                                 24 = 24.5" [622 mm] 
                                                 DESIGN SERIES 
                                                 COIL CASING 
                                                 BLOWER UNIT 
                                                 ACCESSORY 
                                                 DURASTAR 
Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings
RXBC-D17AI 171/2 [445] 20  [508] 18  [8] 161/2 [419]
RXBC-D21BI 21  [533] 28  [711] 27 [12] 20  [508] 
RXBC-D24AI 241/2 [622] 321/2 [826]
Model 
Number
34 [16]
Width 
(in.) [mm]
231/2 [597]
Height 
(in.) [mm]
Depth 
(in.) 
[mm]
Unit Weight
Supply Air/Return 
Air Openings
RXBC-D21AI 21  [533] 20  [508] 20  [9] 20  [508]
1931/32 
[508]
RXBC-D14AI 14  [356] 233/16 [589]
215/
8 
[549]
19  [9] 13  [330]
23 [10]
23 [10]
36 [17] 
44 [20]
26 [12]
Ship. Wt. 
(lbs.) [Kg.]
Depth 
(in.) 
[mm]
Weight 
(lbs.) [Kg.]
 Width 
(in.) [mm]
• INDOOR COIL CASING- RXBC (See Table 5)
HORIZONTAL ADAPTER KIT (RXHH-)
B14x20 131/8[333] 
B17x20
165/8[422]
Uncased Coil Adapter
Model Number RXBA
A
Width (in.) [mm]
B21x20 201/8[511]
-HUxx14
-HUxx17
Uncased Coil
Model RCFP
-HUxx21
B24x20 235/8[599] -HUxx24
Table 6: Uncased Coil Adapter Kit
[  ] Designates Metric Conversions

DURASTAR.COM
9
Accessories 
DRAEF Series
FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED
Note: Sliding the coil into the coil rail before attaching coil rack front.
FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION
• UNCASED COIL ADAPTER KIT 
RXBA- (See Figure 3 & 4) 
This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. 
Each kit contains a quantity of 20 adapters.
Accessories (cont.) 
[  ] Designates Metric Conversions
11/2 
[41 mm]
11
/16 
7
[196 mm]
A
5
20
/16 
[516 mm]

DURASTAR.COM
10
Limited Warranty 
DRAEF Series
GENERAL TERMS OF LIMITED WARRANTY*
Durastar will furnish a replacement for any part of this 
 product which fails in normal use and service within the 
applicable periods stated, in accordance with the terms of 
the limited warranty. 
*For complete details of the Limited and Conditional Warranties, including 
applicable terms and conditions, contact your local contractor or the 
Manufacturer for a copy of the product warranty certificate. 
Parts.......................................................................Five (5) Years

Before proceeding with installation, refer 
to installation instructions packaged 
with each model, as well as complying 
with all Federal, State, Provincial, and 
Local codes, regulations, and practices.
“In keeping with its policy of continuous progress and product improvement, Durastar reserves the right to make changes without notice.” 
@2020 Ferguson Enterprises, LLC 0520                                                 PRINTED IN U.S.A.         8- 20 QG         FORM NO. CDS-224