SPECIFICATION SHEET 
DR80D(-)T Single-Stage Series 
DOWNFLOW GAS FURNACE
FORM NO. GDS-559 REV. 1
PRODUCT FEATURES 
• 80% residential Gas Furnace CSA certified 
• 7 Segment LED all units 
• Direct spark ignition for reliability and longevity 
• Heat exchanger is removable for improved serviceability. Aluminized steel 
construction provides maximum corrosion resistance and thermal fatigue 
reliability. 
• Low profile 34" cabinet ideal for space constrained installations 
• Integrated Control board features dip switches for easy system set up 
• QR code for quick access to product information from your smart phone  
or tablet 
• Constant Torque electrically commutated motor
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy 
test procedures.
80% A.F.U.E.† 
INPUT RATES 50 TO 125 kBTU
1

DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
2
TABLE OF CONTENTS 
Standard & Optional Equipment ......................................................................3 
Model Features/Physical Data & Specifications ................................................4 
Model Number Identification ............................................................................5 
Dimensional Data............................................................................................6 
Blower Performance Data................................................................................7 
Accessories....................................................................................................8 
Limited Warranty ............................................................................................9

Standard & Optional Equipment 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
3
STANDARD EQUIPMENT 
Completely assembled and wired; induced draft; pressure 
switch; redundant main gas control; blower compartment door 
safety switch; solid state time on/time off blower control; limit 
control; manual shut-off valve, pressure regulator for natural 
and L.P. (propane) gas; transformer; direct drive multi-speed 
blower motor. Furnaces are equipped with cooling/heating 
relay and transformer (40VA) ready for air conditioning 
applications. (Please note: a thermostat is not included as 
standard equipment.) Flame sensor diagnostics; on-board 
twinning; fused-protection (secondary), 3rd speed option for 
continuous fan; common heat/cool terminal. 
OPTIONAL EQUIPMENT 
NOTE: Furnace is not listed for use with fuels other than 
natural or L.P. (propane) gas. 
The complete terms of limited and other warranties are 
available at our sales office, or through local installer. 
All models can be converted by a qualified Durastar distributor 
or local service dealer to use L.P. (propane) gas without 
changing burners. Factory approved kits must be used to 
convert from natural to L.P. (propane) gas and may be ordered 
as optional accessories from a Durastar parts distributor. 
For L.P. (propane) operation, refer to Conversion Kit Index Form. 
NOTE: For natural and L.P. (propane) gas models, direct spark 
ignition is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED 
OR RECOMMENDED 
FOR USE IN MOBILE HOMES
HEAT EXCHANGER
INTEGRATED 
FURNACE 
CONTROL
DIRECT SPARK IGNITOR 
WITH REMOTE SENSE
IN-SHOT BURNERS
DRAFT INDUCER MOTOR
CONSTANT TORQUE ECM MOTOR

MODEL NUMBERS 
DR80D(-)T SERIES
0501314SA 0751317SA 0751521SA 1001521SA 1251524SA
Input in BTU’s/Hr [kW]
 ➁
50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 125,000 [37]
Heating Capacity in BTU’s/Hr [kW]
 ➀
40,000 [12] 60,000 [18] 60,000 [18] 80,000 [23] 100,000 [29] 
Heat Ext. Static Pressure in wc [kPa] .10 [.025] 0.12 [0.029] 0.12 [0.029] 0.15 [0.037] 0.2 [0.05] 
Blower (D x W) in inches [mm] 11 x 6[279 x 152] 11 x 7[279 x 178] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254]
Motor H.P.-Speeds - Type [W]
1/2 hp [373] 5 Spd 
Constant Torque
1/2hp, 5spd, X-13 [373] 1hp, 5spd, X-13 [746] 1hp, 5spd, X-13 [746] 1hp, 5spd, X-13 [746]
Min. Circuit Ampacity 9 9 13 12 15 
Min. Overload Protection 15 15 15 15 20 
Max. Overload Protection 15 15 20 15 25 
Heating Speed (factory setting) MED-LOW MED-HIGH MED MED-HIGH MED-HIGH 
Cooling Speed (factory setting) HIGH HIGH HIGH HIGH HIGH 
Cooling in CFM [L/s] @ 0.5 wc 
[0.12 kPa] E.S.P. (nominal)
1301[614] 1200 [566] 2000 [944] 2000 [944] 2000 [944]
Rated E.S.P. in wc [kPa] 0.5 [.12] 0.5 [0.12] 0.5 [0.12] 0.5 [0.12] 0.5 [0.12] 
Temperature Rise Range in °F [°C] 25-55 [13.9-30.6] 35-65 [19.4-36.1] 25-55 [13.9-30.6] 30-60 [17-33] 35-65 [19.4-36.1] 
Max Outlet Air in °F [°C] 155 [68.3] 190 [87.7] 165 [73.8] 190 [87.7] 185 [85.0] 
Approx. Shipping Weight in Lbs. [kg] 85 [38.6] 105 [48] 120 [54] 120 [54] 140 [63] 
AFUE - Electronic Ignition Modules
 ➀
80% 80% 80% 80% 80%
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" N.P.T. 
      ➀ In accordance with D.O.E. test procedures. 
      ➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. 
This furnace does not meet air district requirements of 14 ng/J NOx emissions limit, and thus is subject to a mitigation fee of up to $450.
 This furnace is not eligible for the 
Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. 
This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits. Operating in natural gas mode is in viola
tion of these Rules. 
[  ] Designates Metric Conversions
Model Features/Physical Data & Specifications 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
4
Physical Data and Specifications 
U.S. and Canadian Models
•
80% residential Gas Furnace CSA certified 
•
7 Segment LED all units 
•
DSI for reliability and longevity 
•
Heat exchanger is removable for improved serviceability. 
Aluminized steel construction provides maximum corrosion 
resistance and thermal fatigue reliability. 
•
Low profile 34" cabinet ideal for space constrained 
 installations 
•
Integrated Controls board features dip switches for easy 
 system set up 
•
QR code for quick access to product information from your 
smart phone or tablet 
•
Constant Torque electrically commutated motor
Model Features

Model Number Identification 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
5
Model Number Identification—Downflow Models
DR 80 D A T 050 1 3 14 S A
Durastar  80 = 
80% AFUE
Configuration - 
Downflow
Revision 
R&D - A
Motor - 
Constant 
Torque
Input 
BTU/HR [kW]
050 =  50,000 [14.7] 
075 =  75,000 [22.0] 
100 = 100,000 [29.0] 
125 = 125,000 [37.0]
Stage - 
Single
3 = Up to 
3 Ton 
4 = 2
1
/2 to 
4 Ton 
5 = 31/2 to 
5 Ton
Cabinet 
Width 
14 = 14".0 
17 = 17.5" 
21 = 21".0 
24 = 24.5"
S = Standard Revision- 
Marketing 
A – First Time 
Release
[  ] Designates Metric Conversions

Dimensional Data 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
6
A
REDUCED CLEARANCES (IN.) [mm]
LEFT  
SIDE
RIGHT 
SIDE
BACK TOP FRONT VENT
SHIP. WGTS. 
(LBS.) [kg]
075521 21
 [533] 1927/32 [504] 137/8 [352]
➀
201/8 [511] 0
0
0 1 [25] 3 [76]
6 [152] ➂
120 [54.4]
075317 171/2 [445] 1611/32 [415] 121/8 [308]
➀
165/8 [422] 0
3 
0 1 [25] 3 [76] 6 [152] 105 [47.6]
050 14
 [356] 2727/32 [326] 103/8 [264]
➀
131/8 [333] 0
4 
0 1 [25] 3 [76] 6 [152]
 85 [38.6]
100 21
 [533] 1927/32 [504] 137/8 [352]
➀
201/8 [511] 0
0
0 1 [25] 3 [76]
6 [152]
➂
120 [54.4]
125 241/2 [622] 2311/32 [593] 155/8 [397]
➀
235/8 [600] 0 0
0 1 [25] 3 [76]
6 [152] ➂
140 [63.5]
MODEL 
DR80D(-)T 
(DOWNFLOW) 
SERIES
B C D E
Dimensional Data
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.  
      ➁ May be 0" [0 mm] with type B vent. 
       ➂ May be 1" [25 mm] with type B vent. 
       Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes. 
[  ] Designates Metric Conversions
Downflow Dimensions

AIR FLOW PERFORMANCE - DR8OD(-)T SINGLE-STAGE SERIES (Downflow) MODELS
INPUT 
(Btu) 
CABINET 
WIDTH (in)
AIRFLOW  
CONTROL  
SETTINGS
SPEED 
TAP
CFM [L/s] AIR DELIVERY 
EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]
0.1 
[0.02]
0.2 
[0.05]
0.3 
[0.07]
0.4 
[.10]
0.5 
[0.12]
0.6 
[0.15]
0.7 
[0.17]
0.8 
[.19]
0.9 
[.22]
1.0 
[.25]
50k 
14"
CIRC FAN LOW 889 770 615 475 428 377 335 279 227 180
HEAT OR 
HEAT/COOL
MED. LO 1029 989 954 918 884 841 798 759 722 679
COOL MEDIUM 1190 1155 1116 1083 1059 1032 1000 971 939 904
COOL MED. HIGH 1364 1329 1310 1288 1264 1228 1205 1176 1155 1117
COOL HIGH 1419 1395 1362 1336 1309 1298 1271 1249 1222 1192
75k 
17"
CIRC FAN LOW 940 812 673 619 566 508 457 403 362 326
COOL MED. LO 1013 968 916 875 824  772 729 683 642 605
COOL MEDIUM 1222 1184 1126 1089 1051 1016 971 939 897 864
HEAT OR 
HEAT/COOL
MED. HIGH 1384 1348 1310 1269 1235 1206 1171 1139 1109 1076
COOL HIGH 1510 1471 1439 1407 1374 1342 1310 1285 1255 1213
75k 
21"
CIRC FAN LOW 1231 1108 1040 982 915 855 798 738 690 642
COOL MED. LO 1413 1346 1297 1242 1190 1141 1088 1039 992 939
HEAT OR 
HEAT/COOL
MEDIUM 1616 1563 1516 1466 1425 1370 1327 1289 1245 1204
COOL MED. HIGH 1925 1879 1839 1798 1764 1721 1678 1639 1599 1569
COOL HIGH 2154 2117 2074 2041 2008 1969 1933 1881 1804 1715
100k 
21"
CIRC FAN LOW 1236 1117 1051 995 942 873 820 770 713 670
COOL MED. LO 1360 1300 1255 1203 1152 1101 1059 1011 954 924
COOL MEDIUM 1564 1516 1476 1433 1388 1345 1312 1267 1222 1187
HEAT OR 
HEAT/COOL
MED. HIGH 1822 1786 1742 1703 1670 1629 1597 1556 1520 1485
COOL HIGH 1990 1949 1914 1877 1838 1802 1776 1741 1708 1661
125k 
24"
CIRC FAN LOW 1172 989 919 852 781 715 651 613 570 522
COOL MED. LO 1261 1199 1137 1072 1009 950 889 834 778 735
COOL MEDIUM 1519 1454 1398 1350 1295 1242 1190 1142 1097 1051
HEAT OR 
HEAT/COOL
MED. HIGH 1817 1767 1722 1674 1622 1583 1544 1494 1467 1427
COOL HIGH 2391 2350 2299 2214 2151 2070 1990 1904 1787 1661
NOTE: Bold data is factory heating tap 
[  ] Designates Metric Conversions
Blower Performance Data 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
7
Blower Performance Data—Downflow Models

Accessories 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
8
DOWNFLOW ACCESSORIES
DOWNFLOW WARNING: Unit design is certified for installation on noncombustible floor. A special factory supplied combustible floor subbase is required when installing on a combustible floor. Failure to install 
the sub-base may result in fire, property damage and personal injury.
RXGF-CC 
FILTER RACK—Downflow top return mount. Requires (2) 14 x 20 Filters. 
NOTE: Filter racks are shipped without filters. 
FOR HIGH ALTITUDES: 
HIGH ALTITUDE OPTION CODE: U.S. & Canada – 
None required for high altitudes. 
HIGH ALTITUDE CONVERSION KITS: U.S. & Canada – 
None required for high altitudes. 
80+ HIGH ALTITUDE INSTRUCTIONS 
Caution: Always follow National Fuel Gas Code (NFGC) guidelines when 
converting for high altitudes. 
High altitude option codes are not required for these models. However, the 
burner orifice size needs to be recalculated and verified at elevations above 
2000 ft. See Installation Instructions for more information. 
NOTE: For Canadian installations only, an optional derate (manifold gas 
pressure reduction) method may be used to adjust the furnace for 
altitude. See Installation Instructions for more information. This 
optional method may NOT be used for U.S. installations. 
COMBUSTIBLE FLOOR BASE DIMENSIONS
COMBUSTIBLE 
FLOOR BASE
USE WITH 
FURNACE SIZESA IN. [mm]B IN. [mm]
C 
IN. [mm]
RXGC-B17 075317 18
 [457] 163/4 [425] 143/4 [451]
RXGC-B21 100521, 075521 211/2 [546] 201/4 [514] 181/4 [464]
RXGC-B24 125 25
 [635] 233/4 [603] 213/4 [552]
RXGC-B14 050 141/2 [368] 131/4 [337] 111/4 [286]
[  ] Designates Metric Conversions

Limited Warranty 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
9
GENERAL TERMS OF LIMITED WARRANTY*
Durastar will furnish a replacement for any part of this 
 product which fails in normal use and service within the 
applicable period stated, in accordance with the terms of 
the limited warranty
. 
*For complete details of the Limited and Conditional Warranties, 
including applicable terms and conditions, contact your local contractor 
or the Manufacturer for a copy of the product warranty certificate.
Heat Exchanger............................................Ten (10) Years 
Parts ............................................................Five (5) Years 

Notes 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
10

Notes 
DR80D(-)T Single-Stage (DF) Series
DURASTAR.COM
11

Before proceeding with installation, refer 
to installation instructions packaged 
with each model, as well as complying 
with all Federal, State, Provincial, and 
Local codes, regulations, and practices.
“In keeping with its policy of continuous progress and product improvement, Durastar reserves the right to make changes without notice.” 