Du Pont WFPF38001C Installation Instructions Manual

WFPF3800 V4.2L1
Installation Instructions
Universal Valve-in-Head Whole House Filtration Systems
Instrucciones de instalación Sistema universal de filtrado de agua potable
Model Series WFPF38001C
Water Filtration
V4.2L
Installation Instructions
Universal Valve-in-Head Whole House Filtration System
Protect Plus, LLC n Hickory, NC 28601 n USA
Information & Assistance
Parts & Hardware Included
A Valve-in-Head Filter System
(System Head with Filter Housing)
B Black O-Ring C Filter Cartridge D Filter Housing Wrench
Tools & Materials Required
n Compression Fittings/Valves (not included)
(See Step 2: Configure Your System)
n Two Adjustable Wrenches n Pipe Wrench n Pipe Cutter or Hacksaw n Pan or Bucket n File n Pencil n Plumber’s Tape n Silicone Grease
Optional Materials
n Mounting Bracket
DuPont Part No. WFAB150
n Grounding Kit
Package Contents
A
System Head
B
Black O-Ring
DuPont Part No. WFAO150
C
Filter Cartridge
A
Filter Housing
D
Filter Housing Wrench
DuPont Part No. WFAW150
866-709-2086 Toll Free
For Service Requests & Product Information Hours of Operation: 24 Hours/Day, 7 Days/Week
Email us at:
dupontwaterfilters@protectplus.com
“How to Install” Video ­FREE Download:
www.waterfiltration.dupont.com
WFPF3800 V4.2L3
STEP 1
Turn Off the Main Water Supply Line
The Filter System must be installed after the water meter or pressure tank.
CAUTION
1 Turn off the main water supply line to your home. 2 Purge all water from the plumbing lines by turning on all faucets in your home and draining completely.
STEP 2
Configure Your System
See the System Configuration Chart below to determine how you will configure your filter system.
Materials Needed for 3/4” Diameter Housing Inlet/Outlet Ports
TYPE OF PLUMBING
3/4"
COPPER
PIPE
QUANTITY
Solder according to
local plumbing codes.
FITTING
METHOD
No individual fitting (will require
more than 1). Solder according to
local plumbing codes.
Use PVC Primer & PVC Pipe
Cement per your local plumbing
codes.
Use PVC Primer & PVC Pipe
Cement per your local plumbing
codes.
You may need to consult your
local plumber - requires special
tools.
You may need to consult your local
plumber - requires special tools.
1"
COPPER
PIPE
2
Standard Male Adapter
3/4" PVC PIPE
1" PVC PIPE
3/4"
PEX
1"
PEX
3/4" Male Adapters
2
Compression
3/4" OD tube x 3/4" MIP
Compressions Male Adapter.
1" x 3/4" reducing coupling & 3/4"
male adapter
& 3/4" x 2" copper nipple.
Compression
not readily available for 1" copper
pipe.
3/4" MPT x 3/4" tube male
adapter PVC Slip Type.
n/a
3/4" MPT x 1" tube male adapter
PVC Slip Type.
n/a
3/4" MPT x 3/4" CTS QC Adapter
(WATTS Water PEX).
3/4" MPT x 1" CTS QC Adapter
(WATTS Water PEX).
2
Union
3/4" Copper Union & 3/4" Male
Adapter & 3/4" x 2" copper nipple.
1" Copper Union & 1" x 3/4" reducing coupling & 3/4" male adapter & (2) 3/4" x 2" copper
nipple.
3/4" PVC Union & 3/4" MPT x
3/4" tube male adapter PVC Slip
Type & 3/4" x 2" PVC nipple.
1" PVC Union & 3/4" MPT x 1"
tube male adapter PVC Slip Type
& 1" x 2" PVC nipple.
NOTE: For galvanized piping, consult a professional plumber.
1
2
WFPF3800 4 V4.2L
Proper Installation
Please read all instructions, specifications, and precautions before installing and using your water filter system.
This filter must be protected from freezing, which can cause cracking of the filter and water leakage.
CAUTION
Precautions: For cold water use only.
After prolonged periods of non-use (such as during a vacation), it is recommended that the system be flushed thoroughly. Let water run for 10 minutes before using.
The filter cartridges used with this system have a limited service life. Changes in taste, odor, and/or flow of the water being filtered indicate that the cartridge should be replaced.
Do not install where system will be exposed to direct sunlight. Your water filtration system will withstand up to 100 psi water pressure. If your house water supply pressure is higher than 100 psi, install a
pressure reducing valve before the system is installed.
Before You Begin
n Locate the main water supply line to your home and check to see what type of plumbing is in place (ex: plastic, copper, galvanized).
The main water supply line is typically located in a basement, crawlspace or garage. Connect to cold water line only.
n Measure the diameter of the existing pipe to determine what size fittings and/or valves (not included) will be required. n Choose a location in the main supply line to install the Filter System. Make sure to place the Filter System in an area after the water
meter or pressure tank and before the water heater. Also select a location that will be easily accessible when changing filter cartridges.
n Consult your local plumbing codes and install accordingly.
WFPF3800 V4.2L5
STEP 3
Assemble the System
1 Dry assemble the complete system (according to the configuration chosen), including all fittings and valves.
OPTIONAL: If using a mounting bracket (not included), position it on the Filter System Head in alignment with the inlet and outlet ports.
2 Measure the overall length (see diagram) of the configured system. 3 Reduce this measurement enough to allow for the amount of engagement (X) to determine how much pipe to remove from the line.
STEP 4
Mark Measurements and Cut the Plumbing Pipe
CAUTION
Please wear safety glasses to protect eyes when cutting.
1 Mark the section of the plumbing pipe that will need to be removed (X) to allow for the configured system (as determined in Step 3).
NOTE: Measure twice, cut once!
2 Using a pipe cutter or hacksaw, cut the marked section from the plumbing pipe.
NOTE: Use a pan or bucket to catch any remaining water in the pipes.
3 Remove any burrs or debris from the cut edges with a file.
3
1
X
2
3
4
X
WFPF3800 6 V4.2L
STEP 5
Hang the Filter System Head
1 Align the System Head A on the pipes so that the inlet and outlet are in the correct locations. The “in” port on the Filter System should
be facing the incoming water supply.
2 Allow the System Head to temporarily hang between the two cut plumbing pipes. 3 Apply plumber’s tape or appropriate sealant to the fittings and lines, according to your system configuration. 4 Make all connections and tighten fittings.
NOTE: Keep the Filter System in an upright position.
A grounding kit (not included) must be installed on water pipes if they are used to ground electrical systems, appliances or phones.
CAUTION
STEP 6
Install the Filter Housing
1 Insert the Filter Cartridge C over standpipe in the bottom of the Filter Housing A. 2 Screw the Filter Housing back onto the System Head and hand-tighten D.
IMPORTANT: Do not over tighten.
GROUNDING KIT (NOT INCLUDED)
5
3
IN OUT
WATER
FLOW
TO
HOUSE
A
6
A
C
D
Loading...
+ 14 hidden pages