Du Pont WFPF3800 Series, WFPF2800 Series, WFCH2 series Installation Instructions Manual

Installation Instructions
Universal Valve-in-Head Whole House Filtration Systems
Instrucciones de instalación Sistema universal de filtrado para toda la casa con válvula en el cabezal
Water Filtration
Model Series WFPF3800 & WFPF2800
V4.0
Package Contents
Installation Instructions
Universal Valve-in-Head Whole House Filtration System
Parts & Hardware Included
A
Valve-in-Head Filter System
(System Head with Filter Housing)
B Black O-Ring C Filter Cartridge D Filter Housing Wrench
Tools & Materials Required
n Compression Fittings/Valves (not included)
(See Step 2: Configure Your System)
n Two Adjustable Wrenches
n Pipe Wrench
n Pipe Cutter or Hacksaw
n Pan or Bucket
n File
n Pencil
n Plumber’s Tape
n Silicone Grease
Optional Materials
n Mounting Bracket, Bolts & Screws
DuPont Part No. WFAB150
n Grounding Kit
A
B
A
D
C
For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code CMR248 shall be adhered to.
www.waterfiltration.DuPont.com
Protect Plus, LLC n Hickory, NC 28601 USA
866-709-2086Toll Free
For Service Requests & Product Information Hours of Operation: 24 Hours/Day, 7 Days/Week
800-441-7515
For Safety & Health Questions
Information & Assistance
System Head
Black O-Ring
DuPont Part No. WFAO150
Filter Cartridge
Filter Housing
Filter Housing Wrench
DuPont Part No. WFAW150
WFPF3800 / WFPF2800 Series
2
V4.0
Proper Installation
Please read all instructions, specifications, and precautions before installing and using your water filter system.
Precautions:
For cold water use only.
After prolonged periods of non-use (such as during a vacation), it is recommended that the system be flushed thoroughly. Let water run for 10 minutes before using.
The filter cartridges used with this system have a limited service life. Changes in taste, odor, and/or flow of the water being filtered indicate that the cartridge should be replaced.
Do not install where system will be exposed to direct sunlight.
Your water filtration system will withstand up to 100 psi water pressure. If your house water supply pressure is higher than 100 psi, install a pressure reducing valve before the system is installed.
Before You Begin
n Locate the main water supply line to your home and check to see what type of plumbing is in place (ex: plastic, copper, galvanized).
The main water supply line is typically located in a basement, crawlspace or garage. Connect to cold water line only.
n Measure the diameter of the existing pipe to determine what size fittings and/or valves (not included) will be required.
n Choose a location in the main supply line to install the Filter System. Make sure to place the Filter System in an area after the
water meter or pressure tank and before the water heater. Also select a location that will be easily accessible when changing filter cartridges.
n Consult your local plumbing codes and install accordingly.
This filter must be protected from freezing, which can cause cracking of the filter and water leakage.
CAUTION
Because of the product’s limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the housing be replaced every ten years. If the head of the filter has been in use for longer than this period, it should be replaced immediately. Date the top of any new head to indicate the next recommended replacement date.
CAUTION
WFPF3800 / WFPF2800 Series
3
V4.0
STEP 1
Turn Off the Main Water Supply Line
1 Turn off the main water supply line to your home.
2 Purge all water from the plumbing lines by turning on all faucets in your home and draining completely.
STEP 2
Configure Your System
See the System Configuration Chart below to determine how you will configure your filter system.
NOTE: For galvanized piping, consult a professional plumber.
2
The Filter System must be installed after the water meter or pressure tank.
CAUTION
1
Type of plumbing in your house: 3/4” Copper Pipe 1” Copper Pipe 3/4” PVC Pipe 1” PVC Pipe 3/4” PEX 1” PEX
Quantity Fitting Method
Solder according to local
plumbing
No individual fitting - it will require more than just 1. Solder according to local plumbing codes
Use PVC Primer & PVC
Pipe Cement per your
local plumbing codes
Use PVC Primer & PVC
Pipe Cement per your
local plumbing codes
You may need to consult
your local plumber -
requires special tools
You may need to consult
your local plumber -
requires special tools
2 Std Male Adapter 3/4” Male Adapters
1” x 3/4” reducing
coupling & 3/4” male
adapter & 3/4” x 2” copper
nipple
3/4” MPT x 3/4” tube male
adapter PVC Slip Type
3/4” MPT x 1” tube male
adapter PVC Slip Type
3/4” MPT x 3/4” CTS QC
Adapter
(WATTS Water PEX)
3/4” MPT x 1” CTS QC
Adapter
(WATTS Water PEX)
2 Compression
3/4” OD tube x 3/4” MIP
Compressions Male
Adapter
Compression not readily
available for 1” copper
pipe
n/a n/a
2 Union
3/4” Copper Union & 3/4” Male Adapter & 3/4” x 2”
copper nipple
1” Copper Union & 1” x
3/4” reducing coupling &
3/4” male adapter & (2)
3/4” x 2” copper nipple
3/4” PVC Union & 3/4”
MPT x 3/4” tube male
adapter PVC Slip Type &
3/4” x 2” PVC nipple
1” PVC Union & 3/4” MPT
x 1” tube male adapter
PVC Slip Type & 1” x 2”
PVC nipple
Materials Needed For 3/4” Diameter Housing Inlet/Outlet Ports
STEP 3
Assemble the System
1 Dry assemble the complete system (according to the configuration chosen), including all fittings and valves.
OPTIONAL: If using a mounting bracket (not included), position it on the Filter System Head in alignment with the inlet and outlet ports.
2 Measure the overall length (see diagram) of the configured system.
3 Reduce this measurement enough to allow for the amount of engagement (X) to determine how much pipe to remove from the line.
STEP 4
Mark Measurements and Cut the Plumbing Pipe
1 Mark the section of the plumbing pipe that will need to be removed (X) to allow for the configured system (as determined in Step 3).
NOTE: Measure twice, cut once!
2 Using a pipe cutter or hacksaw, cut the marked section from the plumbing pipe.
NOTE: Use a pan or bucket to catch any remaining water in the pipes.
3 Remove any burrs or debris from the cut edges with a file.
3
WFPF3800 / WFPF2800 Series
4
V4.0
4
1
2
3
Please wear safety glasses to protect eyes when cutting.
CAUTION
WFPF3800 / WFPF2800 Series
5
V4.0
STEP 5
Hang the Filter System Head
1 Align the System Head A on the pipes so that the inlet and outlet are in the correct locations. The "in" port on the Filter
System should be facing the incoming water supply.
2 Allow the System Head to temporarily hang between the two cut plumbing pipes.
3 Apply plumber’s tape or appropriate sealant to the fittings and lines, according to your system configuration.
4 Make all connections and tighten fittings.
NOTE: Keep the Filter System in an upright position.
STEP 6
Install the Filter Housing
1 Insert the Filter Cartridge C over standpipe in the bottom of the Filter Housing A.
2 Screw the Filter Housing back onto the System Head and hand-tighten. Using the Filter Housing Wrench D, tighten 1/4 turn.
NOTE: Do not over tighten.
5
3
A grounding kit (not included) must be installed on water pipes if they are used to ground electrical systems, appliances or phones.
CAUTION
GROUNDING KIT (NOT INCLUDED)
WATER
FLOW
TO
HOUSE
6
2
D
A
A
IN OUT
C
Loading...