USER'S
INFORMATION
MANUAL
DCC-150/205
DCB -125/165
WARNING: If the information in this manual
is not followed exactly, a re or explosion
may result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the re department.
- Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
Information and specications outlined in this manual in effect at the
time of printing of this manual. Manufacturer reserves the right to
discontinue, change specications or system design at any time without
notice and without incurring any obligation, whatsoever.
Manufactured by:
ECR International Inc.
2201 Dwyer Avenue, Utica, NY 13501
Tel. 800 253 7900
www.ecrinternational.com
PN 240011960 REV A, [01/01/2018]
1 - GENERAL
1.1 GENERAL
This boiler has few USER serviceable parts. Maintenance
and Service shall be completed by qualied agency.
!
WARNING
Fire, explosion, asphyxiation and electrical shock
hazard. Improper maintenance and service could
result in death or serious injury. Read this manual
and understand all requirements, including use of
qualied service agent where directed.
1.2 BECOME FAMILIAR WITH SYMBOLS
IDENTIFYING POTENTIAL HAZARDS.
This is the safety alert symbol. Symbol alerts you to
potential personal injury hazards. Obey all safety messages
following this symbol to avoid possible injury or death.
!
DANGER
Indicates a hazardous situation which, if not avoided,
WILL result in death or serious injury
!
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
!
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
!
WARNING
Following service procedures shall be performed
by qualied service agent. Boiler owner shall not
attempt these steps. Failure to do so could result in
death or serious injury.
!
WARNING
Combustion chamber insulation in this product
contains ceramic ber material. Ceramic bers
can be converted to cristobalite in very high
temperature applications. The International Agency
for Research on Cancer (IARC) has concluded,
Crystalline silica inhaled in the form of quartz
or cristobalite from occupational sources is
carcinogenic to humans (Group1). Avoid breathing
dust and contact with skin and eyes. Use NIOSH
certied dust respirator (N95). This type of
respirator is based on the OSHA requirements
for cristobalite at the time this document was
written. Other types of respirators may be needed
depending on the job site conditions. Current
NIOSH recommendations can be found on the
NIOSH website at http://www.cdc.gov/niosh/
homepage.html. NIOSH approved respirators,
manufacturers, and phone numbers are also listed
on this website. Wear long-sleeved, loose tting
clothing, gloves, and eye protection. Apply enough
water to the combustion chamber lining to prevent
dust. Wash potentially contaminated clothes
separately from other clothing. Rinse clothes
washer thoroughly.
NIOSH stated First Aid. Eye: Irrigate immediately.
Breathing: Fresh air.
NOTICE
Used to address practices not related to personal
injury.
Use of CO monitor is manufacturer recommended and may
be requirement of local jurisdiction.
1.3 WHAT TO DO SHOULD OVERHEATING OCCUR
Do not turn off or disconnect electrical supply to pumps.
Shut off gas supply at location external to appliance.
1.4 WHAT TO DO IF BOILER OR ANY PART HAS
BEEN UNDER WATER
Do not use boiler if any part has been under water.
Immediately call a qualied service technician to inspect
boiler and to replace any part of control system and any
gas control which has been under water.
2
PN 240011960 REV A, [01/01/2018]
2 - OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
!
WARNING
If you do not follow these instructions
exactly, a re or explosion may result
causing property damage, personal injury
or loss of life.
• This appliance is equipped with an ignition device
which automatically lights burner. Do NOT try to
light this burner by hand.
• Before operating smell all around appliance area for
gas. Be sure to smell next to oor because some gas
is heavier than air and will settle to the oor.
• Use only your hand to turn the gas shutoff valve.
Never use tools. If valve will not turn by hand, do not
try to repair it, call a qualied service technician. Force
or attempted repair may result in re or explosion.
• Do not use this appliance if any part has been
under water. Immediately call a qualied service
technician to inspect appliance and to replace any part
of control system and any gas control which has been
under water.
• Do not block the ow of combustion or
ventilation air to boiler.
!
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the re department.
2.1 OPERATION
Boiler is wall mounted, fan assisted room-sealed
combination boiler, providing both central heating and
domestic hot water depending on model purchased.
• After initial lighting, boiler will provide central heating
(as required).
• Hot water is available whenever a hot tap is open
(Combi models only).
2.2 OPERATING INSTRUCTIONS
Stop! Read ALL Safety information above.
• Set thermostat to lowest setting.
• Turn “OFF” all electrical power to appliance.
• This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light
burner by hand!
• Turn gas shutoff valve clockwise to closed position.
Handle should be perpendicular to gas pipe.
• Wait 5 minutes for any gas to clear. Smell for gas,
including near oor. If you smell gas, STOP! Follow
instructions on this page: “What To Do If You Smell
Gas.” If you do not smell gas, go to next step.
• Turn gas shutoff valve counter clockwise to the open
position. Handle should be parallel to gas pipe.
• Replace front jacket panel.
• Turn “ON” electrical power to appliance.
• Set thermostat to desired setting.
• Set correct operating mode. See 2.4
• If the appliance will not operate, follow instructions TO
TURN OFF GAS TO APPLIANCE and call your service
technician or gas supplier.
2.3 TURN OFF GAS TO APPLIANCE
• Set thermostat to lowest setting.
• Turn “OFF” all electric power to appliance if service is
to be performed.
• Turn gas shutoff valve handle clockwise to closed
position. Handle should be perpendicular to gas pipe.
2.4 OPERATING MODES
SYMBOL
DISPLAYED
OPERATING MODE
DHW
DHW & HEATING
HEATING ONLY
To enable the appliance in DHW - Heating or Heating only press
repeatedly and choose one of three available modes.
To disable the boiler operating modes and keep the frost protection
function enabled, press for at least 3 seconds. Just the symbol
appears on the display (the display backlighting ashes if the boiler is
blocked).
3
PN 240011960 REV A, [01/01/2018]