WARNING: If the information in this manual
is not followed exactly, a re or explosion may result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of this or any other appliance.
Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the gas supplier.
Information and specications outlined in this manual in effect at the time of printing of this manual. Manufacturer reserves the right to discontinue, change specications or system design at any time without notice and without incurring any obligation, whatsoever.
Manufactured by:
ECR International Inc.
2201 Dwyer Avenue, Utica, NY 13501
Tel. 800 253 7900
www.ecrinternational.com
PN 240011960 REV A, [01/01/2018]
1 - GENERAL
1.1 GENERAL
This boiler has few USER serviceable parts. Maintenance
and Service shall be completed by qualied agency.
!
WARNING
Fire, explosion, asphyxiation and electrical shock
hazard. Improper maintenance and service could result in death or serious injury. Read this manual
and understand all requirements, including use of qualied service agent where directed.
1.2 BECOME FAMILIAR WITH SYMBOLS IDENTIFYING POTENTIAL HAZARDS.
This is the safety alert symbol. Symbol alerts you to
potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death.
!
DANGER
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury
!
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
!
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
!
WARNING
Following service procedures shall be performed by qualied service agent. Boiler owner shall not
attempt these steps. Failure to do so could result in death or serious injury.
!
WARNING
Combustion chamber insulation in this product
contains ceramic ber material. Ceramic bers can be converted to cristobalite in very high temperature applications. The International Agency
for Research on Cancer (IARC) has concluded, Crystalline silica inhaled in the form of quartz or cristobalite from occupational sources is
carcinogenic to humans (Group1). Avoid breathing dust and contact with skin and eyes. Use NIOSH certied dust respirator (N95). This type of respirator is based on the OSHA requirements
for cristobalite at the time this document was written. Other types of respirators may be needed
depending on the job site conditions. Current NIOSH recommendations can be found on the NIOSH website at http://www.cdc.gov/niosh/ homepage.html. NIOSH approved respirators,
manufacturers, and phone numbers are also listed
on this website. Wear long-sleeved, loose tting clothing, gloves, and eye protection. Apply enough water to the combustion chamber lining to prevent
dust. Wash potentially contaminated clothes
separately from other clothing. Rinse clothes washer thoroughly.
NIOSH stated First Aid. Eye: Irrigate immediately. Breathing: Fresh air.
NOTICE
Used to address practices not related to personal injury.
Use of CO monitor is manufacturer recommended and may be requirement of local jurisdiction.
1.3 WHAT TO DO SHOULD OVERHEATING OCCUR
Do not turn off or disconnect electrical supply to pumps.
Shut off gas supply at location external to appliance.
1.4 WHAT TO DO IF BOILER OR ANY PART HAS BEEN UNDER WATER
Do not use boiler if any part has been under water.
Immediately call a qualied service technician to inspect
boiler and to replace any part of control system and any
gas control which has been under water.
2
PN 240011960 REV A, [01/01/2018]
2 - OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
!
WARNING
If you do not follow these instructions
exactly, a re or explosion may result causing property damage, personal injury
or loss of life.
This appliance is equipped with an ignition device which automatically lights burner. Do NOT try to
light this burner by hand.
Before operating smell all around appliance area for gas. Be sure to smell next to oor because some gas is heavier than air and will settle to the oor.
Use only your hand to turn the gas shutoff valve. Never use tools. If valve will not turn by hand, do not
try to repair it, call a qualied service technician. Force or attempted repair may result in re or explosion.
Do not use this appliance if any part has been under water. Immediately call a qualied service
technician to inspect appliance and to replace any part
of control system and any gas control which has been
under water.
Do not block the ow of combustion or ventilation air to boiler.
!
CAUTION
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the re department.
2.1 OPERATION
Boiler is wall mounted, fan assisted room-sealed combination boiler, providing both central heating and domestic hot water depending on model purchased.
After initial lighting, boiler will provide central heating (as required).
Hot water is available whenever a hot tap is open (Combi models only).
2.2 OPERATING INSTRUCTIONS
Stop! Read ALL Safety information above.
Set thermostat to lowest setting.
• Turn “OFF” all electrical power to appliance.
This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light
burner by hand!
• Turn gas shutoff valve clockwise to closed position.
Handle should be perpendicular to gas pipe.
Wait 5 minutes for any gas to clear. Smell for gas, including near oor. If you smell gas, STOP! Follow instructions on this page: “What To Do If You Smell
Gas.” If you do not smell gas, go to next step.
Turn gas shutoff valve counter clockwise to the open
position. Handle should be parallel to gas pipe.
Replace front jacket panel.
• Turn “ON” electrical power to appliance.
Set thermostat to desired setting.
Set correct operating mode. See 2.4
• If the appliance will not operate, follow instructions TO
TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier.
2.3 TURN OFF GAS TO APPLIANCE
Set thermostat to lowest setting.
• Turn “OFF” all electric power to appliance if service is to be performed.
Turn gas shutoff valve handle clockwise to closed
position. Handle should be perpendicular to gas pipe.
2.4 OPERATING MODES
SYMBOL
DISPLAYED
OPERATING MODE
DHW
DHW & HEATING
HEATING ONLY
To enable the appliance in DHW - Heating or Heating only press
repeatedly and choose one of three available modes.
To disable the boiler operating modes and keep the frost protection
function enabled, press for at least 3 seconds. Just the symbol
appears on the display (the display backlighting ashes if the boiler is blocked).
3
PN 240011960 REV A, [01/01/2018]