Duluth Forge FVFLC18-1, FVFLC18-2 Installation Instructions Manual

Page 1
VENT-FREE GAS LOGS
INSTALLATION INSTRUCTIONS
MODELS
FVFLC18-1 & FVFLC18-2
For Use With FDLR18-1 Chassis
US
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-855-607-6557, 8:00 am - 4:30 pm EST,
Monday through Friday or email info@factorybuysdirect.com
FVFLC18-1 Shown
Page 2
2
www.factorybuysdirect.com
200235-01A
TABLE OF CONTENTS
Safety ........................................................ 3
Local Codes............................................... 4
Qualied Installing Agency ........................ 4
Installation Guidelines ............................... 5
Installing Logs............................................ 6
Parts .......................................................... 7
Warranty .................................................... 8
SAVE THIS BOOK
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters and also com­plies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State and local codes in some areas prohibit the use of vent-free heaters. Check your state or local codes.
Page 3
3
www.factorybuysdirect.com
200235-01A
INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly posi­tioned onto the burner. The illustrations in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.
Logs must t rmly onto the burner when positioned as shown in the illustrations. Malformed logs or logs with sloppy pin holes must be replaced.
Proper Primary Airow into the
Burner
For proper burner operation and ame ap­pearance, the ow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This ow of air is re­duced if dirt, lint or other obstructions build-up around or inside the venturi. Any obstruction in the venturi tube area must be removed. The ow of air into the venturi is also reduced if the gas orice isn't centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orice may be cor­rected by bending the shutter cap holding the orice to the inlet or the venturi tube.
Ceiling Fans, Portable Fans or Logs
Installed Near Cold Air Returns
Ceiling fans or oscillating oor type fans need to be monitored during the operation of vent­free logs. If the air blows directly into the ame causing it to impinge on the log set, or rebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate ame impingement, and the oor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the ame to impinge on the log and create a sooting situation.
Candles
Avoid the use of scented or decorative can­dles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating magnies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.
Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken replace, you must raise the oor to insure adequate airow and guard against sooting. Raise re­place oor using a noncombustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the log set. The opening of the glass door frame should be the dimen­sion used for the minimum front opening of the rebox.
Wood Burning Fireplaces
The interior of the rebox and the chimney should be cleaned and free of all creosote be­fore installing a gas burning log set. Creosote will soften when heated and can drop on the log set causing odors and possibly sooting.
Page 4
4
www.factorybuysdirect.com
200235-01A
INSTALLING LOGS
WARNING: Failure to position the parts in accordance with these
diagrams or failure to use only parts specically approved with this
heater may result in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to
ensure that no yellow ame comes in contact with any log. With the heater set to High, check to see if yellow ames contact any log. If
so, reposition logs according to the log installation instructions in
this manual. Yellow ames contacting logs will create soot.
It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater.
Each log is marked with a number. This number will help you to identify the logs when installing. After installing logs, add decorative cinders around the grate base, do not place any decora-
tive cinders on logs or burner.
Rear Log Bracket
Middle Log Bracket
Front Log Bracket
Page 5
5
www.factorybuysdirect.com
200235-01A
Log #1
Log #5
Log #7
Log #6
Log #8
Log #2
Log #4
Log #3
MODEL FVFLC18-1
1. Insert log #1 into slots in rear log bracket.
2. Insert log #2 into slots in middle log bracket.
3. Insert logs #3 and #4 into slots in front log bracket.
4. Place log #5 onto logs #1 and #3.
5. Place log #6 onto logs #1 and #4.
6. Place log #7 onto logs #3 and #5.
7. Place log #8 onto log #4.
INSTALLING LOGS
Page 6
6
www.factorybuysdirect.com
200235-01A
INSTALLING LOGS
MODEL FVFLC18-2
1. Insert log #1 into slots in rear log bracket.
2. Insert log #2 into slots in middle log bracket.
3. Insert log #3 into slots in front log bracket.
4. Place log #4 on over the left side of logs #1, #2 and #3.
5. Place log #5 on over the right side of logs #1, #2 and #3.
6. Place log #6 onto logs #2 and #4 as shown below.
7. Place log #7 onto logs #3 and #5 as shown below.
Log #1
Log #5
Log #7
Log #6
Log #2
Log #4
Log #3
Page 7
7
www.factorybuysdirect.com
200235-01A
PARTS
MODELS FVFLC18-1 AND FVFLC18-2
ITEM
FVFLC18-1 FVFLC18-2 DESCRIPTION
QTY
1 FVFLC18-1-1 FVFLC18-2-1 Log 1 1
2 FVFLC18-1-2 FVFLC18-2-2 Log 2 1
3 FVFLC18-1-3 FVFLC18-2-3 Log 3 1
4 FVFLC18-1-4 FVFLC18-2-4 Log 4 1
5 FVFLC18-1-5 FVFLC18-2-5 Log 5 1
6 FVFLC18-1-6 FVFLC18-2-6 Log 6 1
7 FVFLC18-1-7 FVFLC18-2-7 Log 7 1
8 FVFLC18-1-8 --- Log 8 1
This list contains replaceable parts used in your heater. When ordering parts, contact autho­rized dealers of this product or call customer service at 1-855-607-6557. When calling have you model and serial numbers available.
Page 8
200235-01 Rev. A 05/15
Factory Buys Direct 500 Brown Industrial Parkway Canton, GA 30114 1-855-607-6557