FEATURES
80% AFUE Heating input range 50,000 - 125,000 BTUH Cooling capacity supported 1-1/2 through 5 ton Horizontal left or right application-ready from
factory—no field conversion needed Direct replacement for nearly every competitive
horizontal furnace Approved for attic, closet, basement, crawl space,
alcove, garage, and other locations Electronic air cleaner connection (115V) Humidifier connection (24V and 115V) 5 amp fuse for low voltage circuit protection Time delay off for air conditioner SEER
enhancement
WARRANTY
25-year limited warranty on heat exchanger, 5-year limited warranty on covered components (see warranty certificate for details)
HEAT EXCHANGER ASSEMBLY
Crimp-Tite™ crimped aluminized steel heat exchanger for longer life and safe operation
VENTING
Category I venting 4" vent–vertical or horizontal with approved
power venter Inducer orientation allows for 360° vent
connection
CONTROLS
Integrated furnace control with LED diagnostics Direct spark ignition system
SAFETY
CSA certified for US and Canada Safety limits prevent overheating
CABINET
Heavy gauge, insulated cabinet provides strength and quiet comfort
BLOWER
3 speed PSC motors
HORIZONTAL 80
TM
Ducane Gas Furnace
www.ducanehvac.com
THE DIFFERENCE IS QUALITY
FPBB050A3B FPBB075A3B FPBB100A4B FPBB125A5B
GAS NATURAL (LP with conversion kit) INPUT RATE (BTU per Hour) 50,000 75,000 100,000 125,000 HEATING CAPACITY (BTU per Hour) 40,000 61,000 81,000 101,000 AFUE (ISOLATED COMB. SYSTEM) 80% TEMPERATURE RISE 30 - 60 F 40 - 70 F VOLTS / PHASE / HERTZ 115 /1/ 60 STATIC PRESSURE (CERTIFIED MAX) 0.50" W.C. BLOWER MOTOR HORSEPOWER 1/3
1/2 3/4 BLOWER WHEEL (DIA. X WIDTH) 10 x 6 12 x 9 12 x 12 NUMBER OF HEAT EXCHANGERS 2 3 4 5 LIMIT CONTROL, SNAP DISK STYLE 150 F 170 F 170 F 150 F IGNITION CONTROL DIRECT SPARK TRANSFORMER 40 VA, 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED INTEGRATED CONTROL SYSTEM INTEGRATED FURNACE CONTROL SHIPPING DIMENSIONS 54 X 26 X 25 3/4 54 X 29 X 25 3/4 54 X 33 X 25 3/4 SHIPPING WEIGHT 144 153 175 197 MAXIMUM DESIGN OUTLET TEMP. 170 F AUXILIARY LIMIT 130 F 140 F
UNIT SPECIFICATIONS
HORIZONTAL 80
TM
Ducane Gas Furnace
FPBB075A4B FPBB100A5B
GAS NATURAL INPUT RATE (BTU per Hour) 75,000 100,000 HEATING CAPACITY (BTU per Hour) 61,000 81,000 AFUE (ISOLATED COMB. SYSTEM) 80% TEMPERATURE RISE 30 - 60 F VOLTS/PHASE/HERTZ 115/1/60 STATIC PRESSURE (CERTIFIED MAX) 0.50 "W.C. BLOWER MOTOR HORSEPOWER 1/2 3/4 BLOWER WHEEL (DIA. X WIDTH) 10 X 6 12 X 9 NUMBER OF HEAT EXCHANGERS 3 4 LIMIT CONTROL, SNAP DISK STYLE 170 F 160 F IGNITION CONTROL DIRECT SPARK TRANSFORMER 40 VA. 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED INTEGRATED CONTROL SYSTEM INTEGRATED FURNACE CONTROL SHIPPING DIMENSIONS
54 1/2 X 26 X 25 3/4 54 1/2 X 29 X 25 3/4
SHIPPING WEIGHT 157 183 MAXIMUM DESIGN OUTLET TEMP. 170 F AUXILIARY LIMIT 130 F 140 F
UNIT SPECIFICATIONS HIGH AIR FLOW MODELS