FEATURES

92.1% AFUE

Heating input range 50,000 – 125,000 BTUH Cooling capacity supported 1 1/2 - 5 ton Upflow/horizontal-left application flexibility Electronic air cleaner connection (115V) Humidifier connection (115V)

5 amp fused low voltage circuit protection

Time delay off for air conditioner SEER enhancement Twinning compatible

WARRANTY

Limited lifetime warranty on heat exchanger, 5-year limited warranty on covered components (see warranty certificate for details)

HEAT EXCHANGER ASSEMBLY

Crimp-TiteTM crimped aluminized steel primary heat exchanger for longer life and safe operation

Stainless steel secondary heat exchanger maximizes durability and efficiency

VENTING

Category IV appliance

Can be vented horizontally or vertically using 2” or 3” Schedule 40 PVC, ABS, or CPVC (see installation manual for details)

Approved for 2-pipe (direct vent) or single-pipe applications Approved for installations with listed concentric vent kit

CONTROLS

Integrated furnace control with LED diagnostics for fast, accurate troubleshooting

SAFETY

CSA certified for US and Canada

Safety limit prevents overheating

CABINET

Heavy-gauge, insulated cabinet provides strength and quiet comfort Ducane diagnostic sleeve for fast, safe troubleshooting

INDOOR AIR BLOWER

Three-speed PSC blower motor

D u c a n e G a s F u r n a c e

FITS-ALL 92

UPFLOW/ HORIZONTAL-LEFT MODELS

T H E D I F F E R E N C E I S Q U A L I T Y.

W W W. D U C A N E H V A C . C O M

D u c a n e G a s F u r n a c e

FITS-ALL 92

UNIT SPECIFICATIONS

 

CMPE050U2B

CMPE050U3B

CMPE075U2B

 

CMPE075U3B

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

 

 

NATURAL (LP WITH CONVERSION KIT)

 

 

 

INPUT RATE (BTU per Hour)

50,000

 

50,000

 

 

75,000

 

75,000

 

HEATING CAPACITY

46,000

 

 

 

 

70,000

 

AFUE (ISOLATED COMB. SYSTEM)

 

 

92.1%

 

 

 

 

 

 

 

TEMPERATURE RISE

40–70˚F

 

 

35–65˚F

 

 

45–75˚F

 

40–70˚F

VOLTS/PHASE/HERTZ

 

 

115/1/60

 

 

 

 

 

 

 

STATIC PRESSURE (certified max)

 

 

 

0.50"W.C.

 

 

 

.

 

BLOWER MOTOR HORSEPOWER

1/4

 

1/3

 

 

1/4

 

 

1/3

 

BLOWER WHEEL SIZE (dia x width)

 

 

 

10 x 6

 

 

 

 

 

 

 

NUMBER OF HEAT EXCHANGERS

2

 

 

 

 

 

 

 

3

 

 

FLUE AND AIR INLET PIPE–CONNECTION

 

 

2"

 

 

 

 

 

 

 

(schedule 40 PVC, ABS or CPVC used on all)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT CONTROL, SNAP DISC STYLE

170˚F

 

 

170˚F

 

 

170˚F

 

170˚F

GAS VALVE/IGNITION CONTROL

INTEGRATED FURNACE CONTROL W/ 115V HSI SYSTEM

TRANSFORMER

40 VA. 115 VAC PRIMARY, 24 VAC SECONDARY, FOOT-MOUNTED

MAXIMUM OUTLET TEMPERATURE

 

 

 

180˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHIPPING WEIGHTS

152

 

 

 

 

 

 

 

158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CMPE100U3B

 

CMPE100U4B

 

 

 

 

CMPE125U5B

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

 

 

NATURAL (LP WITH CONVERSION KIT)

 

 

 

INPUT RATE (BTU per Hour)

100,000

 

 

100,000

 

 

 

 

125,000

 

HEATING CAPACITY

 

 

93,000

 

 

 

 

 

116,000

 

AFUE (ISOLATED COMB. SYSTEM)

 

 

92.1%

 

 

 

 

 

 

 

TEMPERATURE RISE

40–70˚F

 

 

 

 

 

 

 

 

45–75˚F

VOLTS/PHASE/HERTZ

 

 

115/1/60

 

 

 

 

 

 

 

STATIC PRESSURE (certified max)

 

 

 

0.50"W.C.

 

 

 

 

 

 

 

BLOWER MOTOR HORSEPOWER

1/3

 

 

1/2

 

 

 

 

 

3/4

 

BLOWER WHEEL SIZE (dia x width)

10 x 9

 

12 x 9

 

 

 

 

 

12 x 12

NUMBER OF HEAT EXCHANGERS

 

 

4

 

 

 

 

 

5

 

FLUE AND AIR INLET PIPE–CONNECTION

 

 

2"

 

 

 

 

 

 

 

(schedule 40 PVC, ABS or CPVC used on all)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT CONTROL, SNAP DISC STYLE

170˚F

 

 

 

 

170˚F

 

 

 

GAS VALVE/IGNITION CONTROL

INTEGRATED FURNACE CONTROL W/ 115V HSI SYSTEM

TRANSFORMER

40 VA. 115 VAC PRIMARY, 24 VAC SECONDARY, FOOT-MOUNTED

MAXIMUM OUTLET TEMPERATURE

 

 

 

180˚F

 

 

 

 

 

 

 

SHIPPING WEIGHTS

 

 

187

 

 

 

 

 

217

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: U=Upflow (CMPE050U3)