Ducane (HVAC) EU1P, EM1P, EC1P, EH1P User Manual

FEATURES
All coils are compatible with R22 or R410A All drain pans are compatible with UV lights
EC1P/EM1P
Cased Upflow/Counterflow (EC1P) for application flexibility Upflow/Horizontal (EM1P) for application flexibility Microban® antimicrobial additive in the drain pan to resist mold and mildew growth One of the lowest water retention drain pans in the industry to minimize mold and mildew growth Insulated galvanized steel coil case with durable embossed finish Interlocking door assemblies and snug line seal grommets to minimize air leakage External cabinet mounted distributor body designed for easy changing of orifice sizes and fast TXV connections Foil-face insulation for easy cleaning Two dual drain connections on front of coil for installation flexibility of drain lines around furnace vent and utility connections Side drain pan built in for easy horizontal coil installations (EM1P only) Tubing located at door split for easy coil service or coil cleaning
EU1P
Uncased Upflow/Counterflow for application flexibility Microban® antimicrobial additive in the drain pan to resist mold and mildew growth One of the lowest water retention drain pans in the industry to minimize mold and mildew growth Two dual drain connections on front of coil for installation flexibility of drain lines around furnace vent and utility connections Orifice assembly designed for easy changing of orifice sizes and fast TXV connections
Ducane Evaporator Coils
EC1P
EM1P
EU1P
EH1P
Cased Dedicated horizontal Microban® antimicrobial additive in the drain pan to resist mold and mildew growth Drain pan has trough to fully drain condensate away Insulated galvanized steel coil case with durable embossed finish Top, front, and back panels are removable for easy service or coil cleaning Dual condensate drains on front and back of coil allows flexibility of placement to accommodate left or right airflow furnaces Foil faced insulation for easy cleaning Refrigerant connections on top of coil for ease of installation in left or right airflow furnaces
Warranty - 5- year limited
ARI Certified
Certification applies only when
used with proper components as
listed with ARI.
EH1P
Model Number Guide
EEEEEUUUUUP1P1P1P1P18181818181AAAAANNNNN-----11111
lioCrotaropavE=E seireS
desacnU=UroloC desaC=C elbacilppAtoN=N noitisop-itluM=M
latnoziroH=H
eciveDnoisnapxE htdiWtenibaC notsiP=P1 5.31=AN evlavkcehc/wVXTPHroCA22R=T2 71=BN evlavkcehc/wVXTPHroCAa014R=T4 5.02=CN
yticapaClanimoN not5.1=91,81 not0.2=42,32 not5.2=03,92 not
0.3=63,53 not5.3=24 not0.4/5.3=34 not0.4=05,94,84 not0.5=26,16,06
dessobmEdezinavlaG=M
ecanruFsaGgnihctaM
5.42=DN
Coil Pressure Drop
rotaropavE
A91**E90.61.42.--------------
B,A81**E71.52.93.25.----------­A32**E01.81.62.63.-----------­B32**E90.51.22.13.------------
B,A42**E21.12.03.34.55.---------­A92**E80.31.02.82.73.---------­B92**E60.11.61.32.13.­A03**E--41.12.03.93.15.--------
C,B03**E--11.61.12.82.43.-------­A63**E--41.12.03.93.15.-------­B63**E--11.61.12.82.43.-------­C63**E--60.11 B34**E----31.81.42.13.04.-----­C34**E----90.21.61.02.42.-----­B84**E----31.81.42.13.04.-----­C84**E------71.32.92.73.34.---­C94**E­C05**E------71.32.92.73.34.---­D06**E--------51.81.12.72.23.73. C26**E--------91.32.82.43.04.64. D26**E--------51.81.12.72.23.73
00600800010021004100610081000200220042
.71.32.92.--------
-----21.71.22.82.53.----
MFCporDerusserPlioCteW
-
---------
.