Dts Z1 DMX-512 User Manual

0 (0)
Dts Z1 DMX-512 User Manual

Z1 DMX-512 LED

CONTROLLER

Code 03.LA.009

User’s Manual Rel 1.6 GB

D.T.S. Illuminazione srl - ITALY

http://www.dts-lighting.it

Made in Italy

2 Z1 LED Controller

Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S .

DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.

The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S.

D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.

Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement préalable de D.T.S.

D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S. décline toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits décrits.

Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes. Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.

D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume responsabilidad de ningún tipo sobre la utilización o sobre la aplicació

n de los productos o de los circuitos descritos.

3 Z1 LED Controller

IMPORTANT SAFETY INFORMATION

Fire prevention:

Never locate the fixture on any flammable surface.

Minimum distance from flammable materials: 10 cm

Replace any blown or damaged fuses only with those of identical value

Prevention from electric shock:

High voltage is present inside the unit.

Unplug the unit prior to performing any operation which involves touching the inside of the unit. This equipment must be grounded, do not connect to non-grounded supplies.

The use of a thermal magnetic circuit breaker is recommended for each Z1.

Use only AC supplies 90-260V, 50-60Hz

The unit should never be located in position exposed to rain or in areas of extreme humidity. A good air ventilation is essential for proper equipment work.

Safety:

The external surface of the unit may exeed 50°C; never handle the unit until at least 5 minutes have elapsed since the unit was turned off.

Never install the unit in an enclosed area lacking sufficient air flow.

The ambient temperature should not exeed 40°C and should not be lower than -10°C

DESCRIPTION:

Z1 / DMX-512 LED controller is a unit dedicated to the following LED products by D.T.S.:

MR16 RGB LED lamp; MR16 full color LED lamp; FOCUS LED projectors; HELIOS LED projectors; FOS led bar.

4 channels output DMX-512 Power interface, able to drive RGB+AMBER LED units (Max 100W per output, 25W per channel: 25W red, 25W green, 25W blue, 25W amber ).

4 x 350mA electronically dimmable led control outputs. Main Input voltage range is 90V - 260V, 50 - 60 HZ

It is possible to use this item through every DMX-512 mixer or by using the DTS InfraRed control

MAIN ELECTRICAL CHARACTERISTICS:

Input Voltage Range : Vin 90 - 260 Vac

Frequency : 50 - 60 HZ

Power Consumption Range : 8 - 100 W

Power Factor ( Pf) : 0.95 electronic PFC controller

Efficiency : 90% typical

IP protection grade: IP 20

Output:

Power Output Range : 6 - 100W per output, 1,5 - 25W per channel

Output Current : 350 mA @ 100% per channel (500mA @ 100% per channel in BOOST Mode)

Output Voltage : Vout 48V

Max Load (output) : 15 x MR16 RGB LED lamp or 15 x FOCUS RGB LED projector or 5 x MR16 full color LED lamp or 5 x FOCUS full color LED projector or 1 x HELIOS full color LED projector or 1 x FOS RGBA led bar.

Min Load (output) : 1 x MR16 RGB LED lamp

Control Input:

Control Signal : DMX 512

Dimming System :Constant Current PWM

Address Range : DMX 512 channels addressable by display

APPLICATIONS:

Cinemas - Restaurants and pubs - Discoteques - Architectural - Interior and Exterior.

4

INPUT/OUTPUT CONNECTIONS

Z1 LED Controller

DMX IN-OUT connectors

S T A N D A R D

DM X 5 1 2

CONTROLLER

5

1

4

2

 

3

1=GND 2=DATA- 3=DATA+

Display

Mains 90-260 Vac

50-60 Hz

RGB output

8-pin Female (RJ45)

Pin 1 = RED +

Pin 2 = RED -

Pin 3 = GREEN +

Pin 4 = GREEN -

Pin 5 = BLUE +

Pin 6 = BLUE -

Pin 7 = AMBER + 8 1

Pin 8 = AMBER -

8-pin Female (RJ45)

RJ45 : 8P8C

8P8C indicates 8 positions 8 cables

Infrared sensor input connector

1

8

 

1

8

8-pin Male (RJ45)

Modular Plug

LEDs cabling connection can be done with a standard UTP TIA/EIA 568-A category 3 cable.

The maximum distance between power supply and the last LED lamp in the line should not exceed 100 meters.

5

DMX SIGNAL CONNECTION:

Z1 LED Controller

The unit operates using a digital DMX 512 signal. Connection between the controller and the unit or between units must be carried out using a two pair screened ø0.5 mm cable and a CANNON XLR 5 or 3 pole connector.

Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassis. The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one.

In this way, all the projectors are cascade connected.

CONTROLLER

S T A N D A R D

DM

X

5 1 2

5

1

1=GND

 

 

 

 

2=DATA-

4

2

3=DATA+

3

 

 

P.S:

If the display showing the DMX address flashes, then one of the following errors has occurred:

-DMX signal not present

-DMX reception problem

For Installations where long distance DMX cable connections are needed,we suggest to use a DMX terminator.

The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.

5 1

4

2

3 OUT

120 ohm

PLACE A 120 OHM RESISTOR BETWEEN PIN 2

 

AND 3 OF A MALE XRL CONNECTOR AND PLUG IT

 

INTO THE DMX OUT PANEL CONNECTOR OF THE

PIN 3

LAST UNIT CONNECTED TO THE DMX LINE

PIN 2

The standard configuration of the Z1 is with XLR 5 pins connectors.

6

DMX ADDRESS

Z1 LED Controller

Z1 can be set at 3 (RGB) or 4 (RGBA) leds channels output (please refer to page 14 for details). Z1 RGB can be used in five different modes: 6 DMX channels, 9 DMX channels (default), 1 DMX channel, RGB mode (3 channels) or CUSTOM DMX mode.

Z1 RGBA can be used in five different modes: 6 DMX channels, 10 DMX channels (default), 1 DMX channel, RGBA mode (4 channels) or CUSTOM DMX mode.

If you want to use the Z1 RGB in 6 channels mode, select the 6 CH mode from the MODE menu and set the following addresses on the mixer: (To be used only with DTS Wall mounted

DMX controller 0514L007)

Projector 1

A001

If you want to select the next projector, just add “8”

Projector 2

A009

DTS Wall mounted DMX controller 0514L007 assign 8 DMX

Projector 3

A017

channels per unit also if some channels are not used

…..A….

projector 6 A041

If you want to use the Z1 RGB in 9 channels mode, select the 9 CH mode from the MODE menu and set the following addresses on the mixer:

Projector 1

A001

 

Projector 2

A010

If you want to select the next projector, just add “9”

Projector 3

A019

 

…..A….

projector 6 A046

If you want to use the Z1 RGB in CUSTOM DMX channels mode, select the CUSTOM mode from the MODE menu and set the parameters for Shutter, Dimmer, Red, Green, Blue, Ctc, Macro and Function to the desired DMX channels and confirm the settings with DONE

If you want to use the Z1 RGBA in 10 channels mode, select the 10 CH mode from the MODE menu and set the following addresses on the mixer:

Projector 1

A001

 

Projector 2

A011

If you want to select the next projector, just add “10”

Projector 3

A021

 

…..A….

projector 6 A051

If you want to use the Z1 RGBA in CUSTOM DMX channels mode, select the CUSTOM mode from the MODE menu and set the parameters for Shutter, Dimmer, Red, Green, Blue, Amber, Ctc, Macro and Function to the desired DMX channels and confirm the settings with DONE

Selelcting the DMX address

1)Press the UP-DOWN key until you reach the required DMX address. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).

2)Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.

TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.

7

DISPLAY FUNCTIONS

Z1 RGB

Z1 LED Controller

MENU

 

 

 

 

 

 

 

UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

 

 

 

DOWN

 

 

 

DISPLAY FUNCTIONS

The Z1 display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the

functions of the unit

so that it does not respond to the DMX 512 signal used to control it. Carefully

follow the instructions below before carrying out any variations or selections.

NOTE: the symbol

shows which key has to be pushed to obtain the desired function.

Z1 RGB (3 leds channels output) Software version 2.70

 

 

 

 

 

Floor

MENU Up-Down

 

ENTER Up-Down

ENTER

Up-Down

position

REVERSE DISPLAY

 

 

 

 

Suspension

Reverses display's reading

depending on

 

 

 

 

position

the mounting position

 

 

 

 

 

 

 

 

 

(On the ground or suspended).

Up-Down

 

 

 

 

 

 

 

 

 

 

 

ENTER

Up-Down

Display OFF

 

 

 

 

ENTER

ENTER

ENTER

DISPLAY STAND BY

Display

To turn off the display (after 5 seconds)

Or leave it always on.

always ON ENTER

MENU

Up-Down

 

ENTER Up-Down

DMX MODE

To select DMX mode : 9 ch (default) - 6 Up-Down ch - RGB (3ch) - 1 ch - AUX - CUSTOM

AUX mode let you activate an external

Up-Down

 

ON -OFF control on IR connector.

 

CUSTOM DMX mode let you set the

Up-Down

 

parameters for Shutter, Dimmer, Red,

 

Green, Blue, Ctc, Macro and Function to

Up-Down

the desired DMX channels.

 

 

Up-Down

9 CHANNELS

ENTER

Default DMX Mode = 10 CH

 

 

 

 

 

6 CHANNELS

ENTER

 

 

 

 

 

1 CHANNEL

ENTER

 

 

 

 

 

RGB (3 CHANNELS)

ENTER

 

 

 

 

 

AUX MODE

 

External ON - OFF control on

ENTER

IR connector

 

 

 

 

Custom mode enabled

ENTER Up-Down

 

ENTER

 

 

 

 

 

 

ENTER

Show Custom settings

 

 

 

 

 

 

Setting the parameters

 

 

ENTER on Custom Mode

MENU

Up-Down

 

ENTER Up-Down

BOOST DRIVING

This menu allow to increase the LED’s Up-Down current from 350mA to 500 mA

Boost mode activated

Boost mode deactivated

ENTER

ENTER

Whit BOOST active,the LED’s current is setted to 500mA (30%more gain).

Default = Disable

MENU Up-Down

 

ENTER Up-Down

LED

RGB Min/Max, Smooth and Compression level values settings

Up-Down

8 Z1 LED Controller

Default = 0

ENTER Up-Down

ENTER

 

Default = 255

ENTER

RGB MINIMUM VALUES

This menu allow to select the minimum levels for Red,Green and blue

RGB MAXIMUM VALUES

Up-Down

This menu allow to select the

 

maximum levels for Red,Green and

 

blue

 

These settings have priority on Master Dimmer (DMX channel 2)

Up-Down

SMOOTH VALUE

This menu allow to select the value of the delay( in millisecons) for RGB and Dimmer channels reaction to DMX or Program variation.

Off=25 ms delay (Fast response) 20=250 ms delay (Slow response)

COMPRESSION

 

This menu allow to select between

Up-Down

Linear courrent output or

 

Quadratic courrent output for LEDs

 

Default = Linear

 

SYNC

This menu allow to adjust the PWM Up-Down frequency value (Hz) in order to

reduce flickering in the process of your camera recordings

Default = 0

ENTER Up-Down

ENTER

Default = 255

ENTER

Default = 0

ENTER Up-Down

ENTER

Default = 255

ENTER

ENTER

Up-Down

Range = Off-20

 

Default = 4

ENTER

 

 

Off = 25 ms

 

 

 

Istant responce to DMX variation

 

 

20 = 250 ms

 

 

 

Smooth response to DMX variation

 

 

Linear = Linear

 

ENTER

Up-Down

courrent output

ENTER

 

 

Quadratic =

 

 

 

Linear light

ENTER

 

 

output

 

 

 

Range = 610 Hz -10 KHz

ENTER

Up-Down

Default = 610 Hz

ENTER

MENU Up-Down

ENTER

ENTER Up-Down

ENTER

Up-Down

ENTER

AUTOMATIC MODE

Automatic demo game without DMX controller

ChPr

Chase with 16 steps previously created in REC MODE

Speed and Wait time selectable by user

CUPr

RGB values selectable by user

Rainbow (rAIn) Rainbow colours effect.

Speed time selectable by user

CU01-CU16

Color Macros as on DMX channel 8 (Macro)

 

ENTER

 

Up-Down

 

ENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

 

Up-Down

 

ENTER

 

 

 

 

 

 

 

ENTER Up-Down ENTER

9 Z1 LED Controller

MENU Up-Down

ENTER

ENTER Up-Down

ENTER Up-Down ENTER

AUTOMATIC MODE

Automatic demo game without

DMX controller

WHITE MACROS

16 macros for White color from

2000 to 7200 ° K

DIMMER

Dimmer level selectable by user as on DMX channel 2 (Dimmer) Dimmer level is active for all the programs and macros

SHUTTER

Shutter level selectable by user as on DMX channel 1 (Shutter)

Shutter level is active only for

CU01/CU16 and Wh01/Wh16 macros

ESC

Esc from Automatic Mode Menu

ENTER

Up-Down

ENTER

ENTER

Up-Down

ENTER

MENU Up-Down

ENTER

ENTER

REC MODE

In DMX Recorder Mode,it is possible to create and store the scenes of the ChPr by using an external DMX controller.

The unit must be setted to 9 channels MODE

DMX Recorder Mode

For the programming of ChPr by using a DMX controller, besides the 9 channels necessary to control the unit a further 3 DMX channels are needed.

So that in RECORDER mode ( via DMX) the unit will need 12 channels to be correctly programmed. The three new DMX channels are:

DMX channel 10 = SCENES channel

From 0-10 = no function ( r001)

From 11-255 are displayed the programmable scenes (max 16 scenes from M001 to M0016 )

DMX channel 11 = EDIT channel: -From 0-19 = no function

-From 20-234 the unit runs the configuration given by the received input DMX values.

With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene. -From 235-255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene.

With the channel REC it is possible to record the selected scene as last scene.

DMX channel 12 = RECORDING channel

Records the set scene with a variation between 0 to 255 (the display flashes indicating that the scene has been recorded).It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene. If ChPr is not closed, by indicating the last scene ( Edit channel between 235-255), in playback mode all 16 scenes will be played through even if not programmed

10 Z1 LED Controller

MENU Up-Down

ENTER

ENTER Up-Down

ENTER

SLAVE MODE

Slave mode for ChPr program. All slave units will be synchronised with master unit, running their own Chpr program.

MENU Up-Down

ENTER Up-Down

ENTER

INFRARED MODE

 

NOTE:

Infrared remote control.

 

External infrared remote sensor

By activating Ir MODE, it will be

 

needed.

possible to navigate trought the

 

D.T.S. Code :03.LA.016

unit functions by using the D.T.S.

 

 

infrared remote control.

 

 

D.T.S. Code :0514L008

 

 

MENU Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER

EMERGENCY

Emergency operating mode. By setting Emergency mode, it will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX

signal is missing or not available. Usefull for Emergency EXIT ilumination on public areas.

Default = OFF

Default = White 1

ENTER

Default = 255

ENTER

MENU Up-Down

ENTER

ENTER

DEFAULT

To restore default settings

MENU Up-Down

ENTER Up-Down

ENTER

LIFE TIME

This menu show the total UNIT life tine and the RGB life time

MENU Up-Down

 

ENTER

TEST MODE

RGB colours test with rainbow

MENU Up-Down

 

ENTER

 

 

 

SOFTWARE Software version

Loading...
+ 22 hidden pages