The XR 5 Wash is fitted with a Philips MSD 250/2 discharge lamp
(GY9,5 lampholder base), with a colour temperature of 8500 °K and a luminous flux of
18,000 Lumens.
Average lifespam is 2000 hours, with replacement recommended before 2200 hours
Other recommended lamps: Osram HSD 250/2, GE CSD 250/2.
The unit incorporates:
Motorized zoom (13°-23°), rotating and indexable beam shaper (0°-170°), frost filter, 2
colour conversion filters (3.200°K and 5.600°K), CMY colour generation + a colour wheel (6
dichroic filters + open, with linear selection, and electronic or electromagnetic ballast.
Optical group
Fresnel lens Ø 150 mm (Borosilicate dichroic parabolic reflector)
Zoom
Motorized zoom (13°-23°)
Dimmer / shutter / strobo
Linear dimmer - Shutter - Strobe from 0,85 flash/sec to 10 flash/sec
Colours
CMY color generation system with 3 palettes for gradual and linear insertion +
colour wheel (6 colours + open). Color change with blackout sync
Effects
Rotating and indexable beam shaper (0°-170°)
Colour conversion filters
3.200°K and 5.600°K
Pan / Tilt
Pan 540° (3,9 sec.)Tilt 270° (2,6 sec.)16-bit resolution
16 DMX channels
Connections
4 XLR connectors (In and Out) with 3 and 5 pins.
Power supply
Electromagnetic ballast: 230 V (50/60 Hz) standard. On request 110 V 50/60 Hz.
Power consumption 350 W
Remote Lamp on/off via DMX
Operating ambient temperature -10° / 40°
Weight
m6 m
20 Kg
3
3
4
23 mm
Packing Dimensions
(HxWxL)
550 x 440 x 880 mm
Weight
27 Kg
mm
0
4
5
4
027 °
1
5
mm
m
m
5
5 0
408 mm
5
XR 5 WASH
ARC 1200
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
XR5 can fit a Philips MSD250/2 or a Osram HSD250/2 or a GE CSD250/2.
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology present in the Xr5 requires the assistance of specialised personnel for all
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid matter is IP 20.
6
XR 5 WASH
ARC 1200
3- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
Philips MSD250/2
Power 250W
Luminous flux 18.000 lm
Colour temperature 8.500°K
Lampbase GY9,5
Rated life 3,000 hours
1) Using a screwdriver, remove the 3 screws X,Y, Z, (photo 1) which fix the lamp holder.
Photo 2Photo 1Photo 3
2) Remove the lamp holder assembly and insert the lamp (photo 2).
The lamp used on XR 5 is made in quartz glass and should be handled with care. Always follow the
instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided
in the lamp's packaging. The GY9,5 lamp socket is not symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
3) Replace the lamp assembly and tighten the screws X,Y,Z, which were previously removed (photo3).
3.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit.
Photo 5
Alignment is carried out using the 3 adjusters A, B and C.
During this operation you must have a uniform luminosity all around the projected area.
7
XR 5 WASH
ARC 1200
4- VOLTAGE AND FREQUENCY
The XR5 with electromagnetic ballast can operate at 230 VOLT 50-60 Hz (110 VOLT 50-60 Hz on
request)
5- INSTALLATION
XR5 may be either floor or ceiling mounted.
For floor mounting installations, the XR5 is supplied with four rubber mounting feet on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the XR5 is moving.
Four quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
5.1- Safety cable
We recommend the use of a safety cable or chain connected to the Xr5 and to the suspension truss in
order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable or chain can bear the weight of the entire unit.
You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the
picture below.
A
5.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
8
XR 5 WASH
ARC 1200
5.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
270°
540°
5.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
5.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
6- MAINS CONNECTION
XR5 with electromagnetic ballast operate at 230 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 3,15 amps at 230V,
Strict adherence to regulatory norms is strongly recommended.
Electromagnetic ballast
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR 5.
A good earth connection is essential for the correct operation of the projector.
230V 50 / 60Hz
7- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a
CANNON XLR 5 or 3 pins connector.