DTS XR 5 WASH User Manual

XR 5 WASH XR 5 WASH
User Manual Rel 1.1
GB
2
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S.
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
XR 5 WASH
ARC 1200
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. D.T.S. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
3
XR 5 WASH
ARC 1200
INDEX:
1- TECHNICAL FEATURES 4 2- IMPORTANT SAFETY INFORMATION 5
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid matter
3- MOUNTING THE LAMP 6
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY 7 5- INSTALLATION 7
5.1 Safety cable
5.2 Protection against liquids
5.3 Movement
5.4 Risk of fire
5.5 Forced ventilation
5.6 Ambient temperature
6- MAINS CONNECTION 8
6.1 Protection
7- DMX SIGNAL CONNECTION 9
7.1 DMX Addresses
7.2 Selecting the DMX address
8- DISPLAY FUNCTIONS 11 9- PAN & TILT SPEED 14 10- FANS SPEED 11- ERROR MESSAGES 12- HIDDEN MENU 15 13- OPENING THE PROJECTOR HOUSING 16 14- PERIODIC CLEANING
14.1 Lenses and reflectors
14.2 Fans and air passages
15- PERIODIC CONTROLS 16- DMX PROTOCOLS 17 17-COLOUR WHEEL 22
4
XR 5 WASH
ARC 1200
1- TECHNICAL FEATURES
The XR 5 Wash is fitted with a Philips MSD 250/2 discharge lamp (GY9,5 lampholder base), with a colour temperature of 8500 °K and a luminous flux of 18,000 Lumens. Average lifespam is 2000 hours, with replacement recommended before 2200 hours Other recommended lamps: Osram HSD 250/2, GE CSD 250/2. The unit incorporates:
Motorized zoom (13°-23°), rotating and indexable beam shaper (0°-170°), frost filter, 2 colour conversion filters (3.200°K and 5.600°K), CMY colour generation + a colour wheel (6 dichroic filters + open, with linear selection, and electronic or electromagnetic ballast.
Optical group Fresnel lens Ø 150 mm (Borosilicate dichroic parabolic reflector) Zoom
Motorized zoom (13°-23°)
Dimmer / shutter / strobo Linear dimmer - Shutter - Strobe from 0,85 flash/sec to 10 flash/sec Colours
CMY color generation system with 3 palettes for gradual and linear insertion + colour wheel (6 colours + open). Color change with blackout sync
Effects
Rotating and indexable beam shaper (0°-170°)
Colour conversion filters
3.200°K and 5.600°K
Pan / Tilt Pan 540° (3,9 sec.) Tilt 270° (2,6 sec.) 16-bit resolution 16 DMX channels Connections 4 XLR connectors (In and Out) with 3 and 5 pins.
Power supply
Electromagnetic ballast: 230 V (50/60 Hz) standard. On request 110 V 50/60 Hz. Power consumption 350 W Remote Lamp on/off via DMX
Operating ambient temperature -10° / 40° Weight
m6 m
20 Kg
3
3
4
23 mm
Packing Dimensions (HxWxL)
550 x 440 x 880 mm
Weight
27 Kg
mm 0 4 5
4
027 °
1
5
mm
m m 5
5 0
408 mm
5
XR 5 WASH
ARC 1200
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
XR5 can fit a Philips MSD250/2 or a Osram HSD250/2 or a GE CSD250/2.
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology present in the Xr5 requires the assistance of specialised personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid matter is IP 20.
6
XR 5 WASH
ARC 1200
3- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
Philips MSD250/2 Power 250W Luminous flux 18.000 lm Colour temperature 8.500°K Lampbase GY9,5 Rated life 3,000 hours
1) Using a screwdriver, remove the 3 screws X,Y, Z, (photo 1) which fix the lamp holder.
Photo 2Photo 1 Photo 3
2) Remove the lamp holder assembly and insert the lamp (photo 2). The lamp used on XR 5 is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging. The GY9,5 lamp socket is not symmetrical. DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
3) Replace the lamp assembly and tighten the screws X,Y,Z, which were previously removed (photo3).
3.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic filters and other components inside the unit.
Photo 5
Alignment is carried out using the 3 adjusters A, B and C. During this operation you must have a uniform luminosity all around the projected area.
7
XR 5 WASH
ARC 1200
4- VOLTAGE AND FREQUENCY
The XR5 with electromagnetic ballast can operate at 230 VOLT 50-60 Hz (110 VOLT 50-60 Hz on request)
5- INSTALLATION
XR5 may be either floor or ceiling mounted. For floor mounting installations, the XR5 is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to move or shake whilst the XR5 is moving. Four quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps provided in the box, to fix the unit in any position. .
5.1- Safety cable
We recommend the use of a safety cable or chain connected to the Xr5 and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable or chain can bear the weight of the entire unit. You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the picture below.
A
5.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
8
XR 5 WASH
ARC 1200
5.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement.
270°
540°
5.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT. Minimum distance from the object being illuminated is 2 MT.
5.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
6- MAINS CONNECTION
XR5 with electromagnetic ballast operate at 230 VOLT 50-60 Hz. Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 3,15 amps at 230V, Strict adherence to regulatory norms is strongly recommended.
Electromagnetic ballast
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR 5. A good earth connection is essential for the correct operation of the projector.
230V 50 / 60Hz
7- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a CANNON XLR 5 or 3 pins connector.