DTS XR2000 SPOT CMY User Manual

XR2000 SPOT CMY
User’s Manual Rel 1.6
D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.it
GB
Made in Italy
2
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
scritto della D.T.S .
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
XR2000 SPOT CMY
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de .
D.T.S.
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
D.T.S.
estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
D.T.S.
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
o reproducido, total o parcialmente, sin previa autorizaciónescrita de
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
D.T.S.
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
D.T.S
D.T.S.
3
INDEX:
1- SYMBOLS 4 2- GENERAL WARNING 4 3- GENERAL WARRANTY CONDITION 4 4- TECHNICAL FEATURES 5 5- ACCESSORIES 7 6- IMPORTANT SAFETY INFORMATION 8
6.1 Fire prevention
6.2 Prevention of electric shock
6.3 Protection against ultraviolet radiation
6.4 Safety
6.5 Level of protection against the penetration of solid and liquid objects 7- MOUNTING THE LAMP 9
7.1 Lamp alignment 8- VOLTAGE AND FREQUENCY 10 9- INSTALLATION 10
9.1 Safety cable
9.2 Protection against liquids
9.3 Movement
9.4 Risk of fire
9.5 Forced ventilation
9.6 Ambient temperature 10- MAINS CONNECTION 11
10.1 Protection 11- DMX SIGNAL CONNECTION 12
11.1 DMX Addresses
11.2 Selecting the DMX address 12- FIRMWARE UPDATING 13 13- DISPLAY FUNCTIONS 14 14- ERROR MESSAGES 17 15- HIDDEN MENU 18
15.1 Calibration mode 19 16- PAN & TILT SPEED 20 17- FANS SPEED 18- OPENING THE PROJECTOR HOUSING 21 19- REPLACING GOBOS 20- PERIODIC CLEANING 22
20.1 Lenses and reflectors
20.2 Fans and air passages 21- PERIODIC CONTROLS 22- DMX PROTOCOL 23 23- 8 MOTORS CONTROL CARD 38 24- 8 MOTORS SLAVE CONTROL CARD 39 25- PAN & TILT CARD 40 26- CABLES RESEND CARD 27- DISPLAY CARD 28- LAMP ON-OFF CONTROL CARD 29- ROTATING GOBO WHEEL 41 30- FIXED GOBO WHEEL 42 31- COLOUR WHEEL 1 43
XR2000 SPOT CMY
1- SYMBOLS
Graphic symbols used on this manual
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK RISK
4
XR2000 SPOT CMY
!
F
UV
2M
2- GENERAL WARNING
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON INFLAMMABLE SURFACES”
THIS SYMBOL MEANS “RADIATION FROM THIS LAMP CAN CAUSE DAMAGE TO EYES AND SKIN”
THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT
Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation , use and maintenance. The device is not for domestic use and must be installed by a qualified electrician or experienced person. Always disconnect the device from the mains before replacing the lamp. The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating. The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 24 months from the date of purchase against manufacturing material defects.
5
XR2000 SPOT CMY
4- TECHNICAL FEATURES
The XR2000 SPOT CMY is one of the most powerful moving heads in the 700W range. The XR2000 SPOT CMY in fact delivers a massive 64.300 Lux at 5 m (8° beam angle), thanks to its improved optical group and dichroic glass reflector, combined with a Philips MSR Gold 700/2 Fastfit lamp (50.000 Lumens). The XR2000 SPOT CMY is particularly suitable for all professional applications, both mobile (concerts, shows, tours, special events) and fixed (clubs and other venues), requiring a light with extremely high luminous output and versatility of functions. The XR2000 SPOT CMY is also the ideal light for a vast range of applications in which quiet operation is a priority, thanks to its silent ventilation system and silent pan/tilt operation. The XR2000 SPOT CMY incorporates motorized focus; motorized iris; linear zoom (8°- 30°); a sophisticated CMY colour synthesis system with 3 palettes for linear insertion, plus a colour wheel (7 colours + open); 2 gobo wheels: one customizable rotating gobo wheel (7 gobos) and one customizable fixed gobo wheel (8 gobos); frost filter (soft edge); 3-facet rotating prism; animation wheel rotating in both directions. The 16 bit Pan/Tilt mechanism features an exclusive Super Speed function, and a locking system with recessed buttons. Access to every feature of the internal menu is simple and direct, thanks to the new user interface featuring a LCD backlit graphic display (128 x 64).
XR2000 SPOT CMY (Cod. 03.MS008.EB.L)
• Electronic ballast 90-245V 50/60 Hz • Black finish Also available with white finish (RAL 9003) on demand
Lamp
Lamp: Philips MSR Gold 700/2 Fastfit Automatic switching ON of lamp in case of accidental switching OFF. Lamp ON/OFF via DMX; Reset via DMX.
Optical group
64.300 Lux at 5 m (8° beam angle) Dichroic glass reflector
Focus
Motorized focus
Iris
Motorized iris (16 bit)
Zoom
Motorized zoom (8°- 30°)
6
XR2000 SPOT CMY
4- TECHNICAL FEATURES
Dimmer / shutter / strobo
Linear dimmer Shutter Strobe from 0,85 flash/sec to 6,75 flash/sec Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Colours
CMY colour synthesis system + colour wheel (7 colours + open) with linear selection for perfect 2-colour beams Colour change with blackout sync; rainbow effect
Gobos
2 gobo wheels: 1 rotating (7 indexable 16 bit gobos + open) and 1 fixed (8 gobos + open) Extractable gobo holders for both wheels Gobo change with synchronized blackout Gobo scrolling; Gobo shake
Effects
Indexable prism rotating in both directions (3-facet) Frost filter (soft edge) Animation wheel rotating in both directions
Pan / Tilt
Pan 540° (3,9 sec.); Tilt 270° (2,6 sec.); 16-bit resolution Super Speed function; extremely smooth and precise movements even at the highest speeds Pan / Tilt locking system with recessed buttons Automatic Pan/Tilt repositioning in case of knocks
30 DMX channels (Default)
Internal operating system updatable via DMX
Interface
LCD backlit graphic display (128x64)
Connections
4 XLR connectors (3-pole In and Out; 5-pole In and Out) by Neutrik POWERCONN connector by Neutrik
Power supply
Electronic ballast: 90 - 260 V (50/60 Hz) Power consumption: 820 W
Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Standard accessories
2 x “C” GQuick clamps with “fastlock” connection
Thermal
Operating ambient temperature: -10° / 40°
Weight
44,5 Kg
4- TECHNICAL FEATURES
Dimensions
7
XR2000 SPOT CMY
Packaging Dimensions (LxWxH) 670 x 550 x 730 mm Weight: 49,5 Kg
m m
826
568mm
Unit Dimensions (LxWxH) 568x510x826mm Weight: 44,5 Kg
510mm
7 °2
0
m m
636
5- ACCESSORIES
459mm
As standard
•1 x MSR Gold 700/2 Fastfit lamp
•1 x POWERCONN male cable connector (cod. 0520P014)
•1 x XLR 5 Pins male cable connector (cod. 0508B028)
•1 x XLR 5 Pins female cable connector (cod. 0508B027)
•2 x “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• User’s manual
Optional (on request)
• Wireless DMX receiver card (cod. 03.LA.012)
• “C” Clamp G60 black (max. load 50Kg) (cod. 0521A004)
• “C” Clamp G60 chrome (max. load. 50Kg) (cod. 0521A004.20)
• “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• “C” Clamp G100 black / professional (max. load. 200Kg) (cod. 0521A015)
• Omega clamp with “Fast Lock” connection 1⁄4 turn (cod. 02K00467)
• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (cod. 0521A010)
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
8
XR2000 SPOT CMY
XR2000 SPOT CMY uses a PHILIPS /2
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1.5 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XR2000 SPOT CMY requires the assistance of specialised personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against ultraviolet radiation:
MSR Gold 700 Fastfit lamp
F
2M
UV
-Never turn on the lamp if any of the lenses, filters or ABS covering are damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
6.5 Level of protection against the penetration of solid and liquid objects:
!
!
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20. For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR2000 base (top) (cod. 03.MA009)
• Raincover for XR2000 base (bottom) (cod. 03.MA010)
9
XR2000 SPOT CMY
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
Philips MSR Gold 700/2 Fastfit Power 700W Luminous flux 50,000 lm Colour temperature 7.500°K Lampbase PGJX50 Rated life 750 hours
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
Photo 2Photo 1 Photo 4Photo 3
2) Insert the lamp (photo2).
3)Rotate the lamp 1/4 turn clockwise (photo 3 and 4). The lamp used on XR2000 SPOT CMY is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp’s packaging. The lamp socket is not symmetrical. DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
4) Replace the metal cover and tighten the screws A,B,C, which were previously removed. WARNING: Never look directly at the lamp when it’s lit. Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
PGJX50
UV
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic filters and other components inside the unit. The lamp alignment is also essential to obtain the maximum unifirmity and luminous performance by the projection.
Lamp
Photo 5
Alignment
Normal Hot Spot
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
Z (photo 5)
When the lamp is correctly optimized,
zones wich are brighter than others.
until you achieve a uniform flat field.
you will have an evenly projected light beam, with no shadows or
3 adjusters X, Y and
10
XR2000 SPOT CMY
8- VOLTAGE AND FREQUENCY
The XR2000 SPOT CMY with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
XR2000 SPOT CMY may be either floor or ceiling mounted. For floor mounting installations, the XR2000 SPOT CMY is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hang it. The structure should also be sufficiently rigid so as not to move or shake whilst the XR2000 SPOT CMY is moving. Eight 1/4 turn Fast Locks connections placed in the base of the unit allow to fix the XR2000 SPOT CMY in any position, by using the two Fast Lock “C” clamps provided in the box. .
240 mm
107 mm
9.1- Safety cable
We recommend the use of a safety cable connected to the XR2000 SPOT CMY and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable can bear the weight of the entire unit. You may attach the safety cable to the two holes (A) located on the base of the fixture, as shown in the picture below.
A
!
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
11
XR2000 SPOT CMY
9.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement.
270°
!
WARNING
Do not place any object in the path
of the projector’s movement
9.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT.
540°
F
Minimum distance from the object being illuminated is 2 MT.
9.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
9.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
10- MAINS CONNECTION
XR2000 SPOT CMY with electronic ballast operate at 90-260 VOLT 50-60 Hz. Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 8 amps at 230V, Or 16 amps at 100-120 V Strict adherence to regulatory norms is strongly recommended.
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR2000 SPOT CMY. A good earth connection is essential for the correct operation of the projector.
2M
Electronic ballast 90-260V 50 / 60Hz
!
12
XR2000 SPOT CMY
11- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR 5 or 3 pins connector. Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassy The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one. This way, all the projectors are cascade connected. NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
CONTROLLER S TA ND AR D D M X 5 1 2
5
1
1=GND 2=DATA­3=DATA+
4 2
3
For Installations where long distance DMX cable connections are needed, we suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
5
4
120 ohm
1
2
3
OUT
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
PIN 3
PIN 2
13
XR2000 SPOT CMY
11.1-DMX Addresses
XR2000 SPOT CMY can be controlled with 30 (default) or 22 DMX channels. If you want to use the unit in 30 channels mode (default), set the following addresses on the mixer:
Projector 1 A001 Projector 2 A031 If you want to select the next projector, just add “30”
Projector 3 A061 ….. A…. projector 6 A151
11.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now setted to the new DMX address.
TRICKS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
12 FIRMWARE UPDATING
Warning: This procedure require a base knolewge of computer applications and Windows Hyperterminal program.
To update the software version of the XR2000 SPOT CMY you need: D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008). USB-DMX Driver for the D.T.S. RED BOX interface . (The driver and the installation procedure are available in our web site www.dts-lighting.it)
Updating the software version. Please follow the procedure below to perform the update:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using Windows Hyperterminal program.
Please refer to an authorised DTS service centre.
!
It will be possible to download the software from the reserved area of D.T.S. web site: www.dts-lighting.it.
14
XR2000 SPOT CMY
13- DISPLAY FUNCTIONS
DMX OUT
DMX IN
DMX IN
DMX OUT
MENU
ENTER
DISPLAY
UP
DOWN
FUSE 16A T 5X20
MAINS
Electronic ballast
90-260V 50 / 60Hz
DISPLAY FUNCTIONS
The XR2000 SPOT CMY display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the DTS setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Menu
PAN DIRECTION This menu allows to set the Pan movement. Normal or Reversed
Menu
TILT DIRECTION This menu allows to set the Pan movement. Normal or Reversed
Menu
PAN TILT SPEED Pan Tilt Speed control (1-4)
Pan Direction
Up-Down
Tilt Direction
Up-Down
Pan Tilt Speed
Up-Down
Up-DownENTER
PAN DIRECTION
Pan movement Normal or Reversed
ENTER
Default = Normal
NORMAL
MENU ENTER DOWN UP
Up-DownENTER
TILT DIRECTION
Tilt movement Normal or Reversed
ENTER
Default = Normal
NORMAL
MENU ENTER DOWN UP
Up-DownENTER
PAN TILT SPEED
Pan Tilt Speed control
ENTER
Default = 4
4
MENU ENTER DOWN UP
13- DISPLAY FUNCTIONS
15
XR2000 SPOT CMY
Up-Down
Up-Down
Display
DMX Mode
Menu
DISPLAY FLIP / STAND BY / CONTRAST
Display Flip:
Reverses display's reading depending on the mounting position (On the ground or suspended).
Display Standby: To turn off the display (after 5 seconds) Or leave it always on.
Display Contrast: Display contrast regulation (1-16)
Menu
DMX MODE To select DMX mode : 30 channels or 22 channels
Up-DownENTER
DISPLAY
FLIP
FLIP
Display Flip ON THE GROUND (Default) SUSPENDED
ENTER
ON THE GROUND
MENU ENTER DOWN UP
DISPLAY
STANDBY
FLIP
OFF
MENU ENTER DOWN UP
DISPLAY
CONTRAST
FLIP
Display Standby OFF = Display Standby disabled (Default) ON = Display goes OFF after 5 seconds
Display Contrast 1-16 (Default = 8)
ENTER
ENTER
8
MENU ENTER DOWN UP
Up-DownENTER
DMX MODE
DMX mode
ENTER
30 channels (Default) 22 channels
30 channels
Up-Down
Up-Down
Lamp
Reset
Menu
LAMP Lamp always ON, always OFF, lamp ON-OFF selectable via DMX And lamp life time reset
ADJUST To adjust the lamp with no mixer connected. It’s possible to set the parameters for PAN-TILT and ZOOM
Menu
RESET Reset via DMX ENABLED / DISABLED and unit reset
MENU ENTER DOWN UP
Up-DownENTER
LAMP
BY DMX
FLIP
BY DMX = ON / OFF via DMX (default) ALWAYS ON = Forced ON ALWAYS OFF = Forced OFF RESET COUNTER = Lamp life time
ENTER
reset
DOWN
ENTER
MENU
LAMP
ADJUST
FLIP
DOWN
ENTER
MENU
Up-DownENTER
RESET
BY DMX
ENABLED
UP
UP
LAMP ADJUST = To adjust the lamp
with no mixer connected. It’s possible to set the parameters for PAN-TILT and ZOOM
ENABLED = Reset via DMX enabled (Default) DISABLED = Reset via DMX disabled NOW = Unit motors reset
ENTER
ENTER
MENU ENTER DOWN UP
Loading...
+ 33 hidden pages