Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S.
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S. non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
XR1200 WASH
ARC 1200
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. D.T.S. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
Page 3
3
XR1200 WASH
ARC 1200
INDEX:
1- SYMBOLS 4
2- GENERAL WARNING 4
3- GENERAL WARRANTY CONDITION 4
4- TECHNICAL FEATURES 5
5- ACCESSORIES 6
6- IMPORTANT SAFETY INFORMATION 7
6.1 Fire prevention
6.2 Prevention of electric shock
6.3 Protection against ultraviolet radiation
6.4 Safety
6.5 Level of protection against the penetration of solid and liquid matter
THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON
INFLAMMABLE SURFACES”
THIS SYMBOL MEANS “RADIATION FROM THIS LAMP
CAN CAUSE DAMAGE TO EYES AND SKIN”
THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO
BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT
Read the instruction contained in this user manual carefully, as they give important information
regarding safety during installation , use and maintenance.
The device is not for domestic use and must be installed by a qualified electrician or experienced
person.
Always disconnect the device from the mains before replacing the lamp.
The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating.
The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 36 months from the date of purchase against manufacturing material
defects.
Page 5
5
XR1200 WASH
ARC 1200
4- TECHNICAL FEATURES
The XR1200 WASH is a moving head fitted with a Philips MSR Gold 1200W Fastfit discharge lamp
(95.000 Lumens) combined with a dichroic parabolic reflector.
The XR1200 WASH incorporates motorized zoom (20°- 45° FRESNEL LENS MODEL / 9°-19° PC LENS
MODEL), rotating indexable beam shaper (0°-180°), frost filter, CMY colour generation system, colour
wheel with linear selection for perfect 2-colour beams (6 dichroic filters + 2 colour conversion filters
3.200°K and 5.600°K +open) and electronic ballast. The XR1200 WASH also includes a new Pan / Tilt
locking system with recessed buttons. The XR1200 WASH is particularly suitable for all professional
applications, both mobile (concerts, shows, tours, special events) and fixed (clubs and other venues),
requiring a light with extremely luminous output capable of illuminating objects and large backgrounds
with an endless variety of colours.
Electronic ballast 90-260V 50/60 Hz• Black colour
All models are also available in white colour
Lamp
Lamp: Philips MSR Gold 1200 Fastfit . Automatic switching on of lamp in case of accidental switching off
Lamp on/off via DMX; reset via DMX.
Optical group
XR 1200 WASH FRESNEL:
XR 1200 WASH PC: 1049
Borosilicate dichroic parabolic reflector
Zoom
XR 1200 WASH FRESNEL:
XR 1200 WASH PC: 9
Dimmer / shutter / strobo
Linear dimmer, Shutter, Strobe from 0,85 flash/sec to 10 flash/sec
Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Colours
CMY color generation system with 3 palettes + colour wheel (6 colours + 2 colour conversion filters +
open) with linear selection for perfect 2-colour beams. Color change with blackout sync
Effects
Rotating and indexable beam shaper (0°-180°)
Pan / Tilt
Pan 540° (2,9 sec.). Tilt 270° (1,8 sec.). 16-bit resolution
8 selectable speed ranges (8 selectable pan/tilt speeds); extremely smooth and precise movements even
at the highest speeds. Pan / Tilt locking system with recessed buttons. Automatic Pan/Tilt repositioning
in case of knocks
16 DMX channels
Internal operating system updatable via DMX
INTERFACE
LCD backlit graphic display (128x64)
Connections
4 XLR connectors (3-pole In and Out; 5-pole In and Out) by Neutrik
Power supply
Electronic ballast: 90 - 260 V (50/60 Hz); power consumption: 1320 W
Thermal
Operating ambient temperature: -10° / 40°
Weight
38 Kg (Electronic Ballast)
Motorized zoom ( °- 19°)
27.000 Lux at 5 m (20°). Fresnel lens Ø 200 mm.
.000 Lux at 5 m ( °). PC lens Ø 150 mm.
Motorized zoom (20°- 45°)
Page 6
4- TECHNICAL FEATURES
Dimensions
6
XR1200 WASH
ARC 1200
Packaging Dimensions (LxWxH)
580 x 490 x 800 mm
Weight: 43 Kg
m
m
85
6
430 mm
Unit Dimensions (LxWxH)
500 x 490 x 685mm
Weight: 38 Kg
m
270°
0 m
4
6
500 mm
490 mm
460 mm
5- ACCESSORIES
As standard
•1 x MSR Gold 1200 Fastfit lamp
•1 x POWERCONN male cable connector (cod. 0520P014)
•1 x XLR 5 Pins male cable connector (cod. 0508B028)
•1 x XLR 5 Pins female cable connector (cod. 0508B027)
•2 x “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
•1 x FROST filter (cod. 0506V016 )
• User’s manual
Optional (on request)
• Wireless DMX receiver card (cod. 03.LA.012)
• “C” Clamp G60 black (max. load 50Kg) (cod. 0521A004)
• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (cod. 0521A010)
Page 7
7
XR1200 WASH
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
XR1200 WASH uses a Philips MSR Gold 1200 Fastfit lamp.
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology present in the XR1200 requires the assistance of specialised personnel for all
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
F
2M
6.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
!
UV
6.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid matter is IP 20.
For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR1200 base (top) (cod. 03.MA009)
• Raincover for XR1200 base (bottom) (cod. 03.MA010)
!
Page 8
8
XR1200 WASH
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
Philips MSR Gold 1200 Fastfit
Power 1200W
Luminous flux 95,000 lm
Colour temperature 6.300°K
Lampbase PGJX50
Rated life 750 hours
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
Photo 2Photo 1Photo 4Photo 3
2) Insert the lamp (photo2).
3)Rotate the lamp 1/4 turn clockwise (photo 3 and 4).
The lamp used on XR1200 is made in quartz glass and should be handled with care. Always follow the
instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided
in the lamp's packaging. The lamp socket is not symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
4) Replace the metal cover and tighten the screws A,B,C, which where previously removed.
WARNING: Never look directly at the lamp when it’s lit.
Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
PGJX50
UV
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit. The lamp alignment is also essential to obtain the
maximum unifirmity and luminous performance by the projection.
Lamp
Alignment
Photo 5
NormalHot Spot
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface
no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto
the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
Z (photo 5)
When the lamp is correctly optimized,
zones wich are brighter than others.
until you achieve a uniform flat field.
you will have an evenly projected light beam, with no shadows or
3 adjusters X, Y and
Page 9
9
XR1200 WASH
8- VOLTAGE AND FREQUENCY
The XR1200 with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9-INSTALLATION
XR1200 may be either floor or ceiling mounted.
For floor mounting installations, the XR1200 is supplied with four rubber mounting feet on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the XR1200 is moving.
Eight quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
9.1- Safety cable
We recommend the use of a safety cable or chain connected to the XR1200 and to the suspension truss
in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable or chain can bear the weight of the entire unit.
You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the
picture below.
A
!
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
Page 10
10
XR1200 WASH
9.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
!
270°
WARNING
Do not place any object in the path
of the projector’s movement
9.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
540°
F
Minimum distance from the object being illuminated is 2 MT.
9.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
9.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
10- MAINS CONNECTION
XR1200 with electronic ballast operate at 90-260 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 8 amps at 230V,
Or 16 amps at 100-120 V
Strict adherence to regulatory norms is strongly recommended.
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR1200.
A good earth connection is essential for the correct operation of the projector.
2M
Electronic ballast
90-260V 50 / 60Hz
!
Page 11
11
XR1200 WASH
11- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a
CANNON XLR 5 or 3 pins connector.
Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassy
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it
to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the
second one.
In this way, all the projectors are cascade connected.
NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
CONTROLLER
S TA ND AR D
D M X 5 1 2
5
1
1=GND
2=DATA3=DATA+
42
3
For Installations where long distance DMX cable connections are needed,we suggest to use a DMX
terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor
Between pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
5
4
1
2
3
OUT
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
PIN 3
120 ohm
PIN 2
Page 12
12
XR1200 WASH
11.1-DMX Addresses
XR1200 WASH have 16 DMX channels.
Set the following addresses on the mixer:
Projector 1A001
Projector 2A017If you want to select the next projector, just add “16”
Projector 3A033
…..A….
projector 6A081
11.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will
start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the
projector is now setted to the new DMX address.
TRICKS:
if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a
faster selection.
12 FIRMWARE UPDATING
!
Warning:
This procedure require a base knolewge of computer applications and Windows
Hyperterminal program.
To update the software version of the Xr1200 WASH you will need:
D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).
USB-DMX Driver for the D.T.S. RED BOX interface .
(The driver and the installation procedure are available in our web site www.dts-lighting.it)
Updating the software version.
Please follow the procedure below to perform the update:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using Windows Hyperterminal program.
Please refer to an authorised D.T.S. service centre.
It will be possible to download the software from the reserved area of D.T.S. web site:
www.dts-lighting.it.
Page 13
13
XR1200 WASH
13- DISPLAY FUNCTIONS
DISPLAY
DMX OUT
DMX IN
DMX IN
DMX OUT
MENU
ENTER
UP
DOWN
FUSE 16A T 5X20
MAINS
Electronic ballast
90-260V 50 / 60Hz
DISPLAY FUNCTIONS
The XR1200 display panel shows all the available functions . Using these functions, it is possible to
change some of the parameters and add some functions. Changing the DTS setting can vary the
functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully
follow the instructions below before carrying out any variations or selections.
NOTE: the symbol shows which key has to be pushed to obtain the desired function.
SOFTWARE VERSION: 8 motors R.20 / Pan&Tilt R.29
Menu
PAN DIRECTION
This menu allow to set the Pan
movement.
Normal or Reversed
Menu
TILT DIRECTION
This menu allow to set the Pan
movement.
Normal or Reversed
Menu
PAN TILT SPEED
Pan Tilt Speed control (1-8)
Pan Direction
Up-Down
Tilt Direction
Up-Down
Pan Tilt Speed
Up-Down
Up-DownENTER
PAN DIRECTION
NORMAL
MENU ENTER DOWNUP
Up-DownENTER
TILT DIRECTION
NORMAL
MENU ENTER DOWNUP
Up-DownENTER
PAN TILT SPEED
4
Pan movement Normal or Reversed
Default = Normal
Tilt movement Normal or Reversed
Default = Normal
Pan Tilt Speed control (1-8)
Default = 4
ENTER
ENTER
ENTER
MENU ENTER DOWNUP
Page 14
13- DISPLAY FUNCTIONS
14
XR1200 WASH
Up-Down
Display
Menu
DISPLAY FLIP / STAND BY / CONTRAST
Display Flip:
Reverses display's reading depending on the
mounting position
(On the ground or suspended).
Display Standby:
To turn off the display (after 5 seconds)
Or leave it always on.
Display Standby
OFF = Display Standby disabled
(Default)
ON = Display goes OFF after 5
seconds
Display Contrast
1-16 (Default = 8)
ENTER
ENTER
8
MENU ENTER DOWNUP
Up-Down
Up-Down
Up-Down
DMX Mode
Motors Test
Lamp
Menu
DMX MODE
To select DMX mode :
Mode 1 or Mode 2
Menu
TEST MODE
Full test and single function test.
Menu
LAMP
Lamp always ON, always OFF,
lamp ON-OFF selectable via DMX
And lamp life time reset
ADJUST
To adjust the lamp with no mixer
connected.
It’s possible to set the parameters for
PAN-TILT and ZOOM
Up-DownENTER
DMX MODE
Mode1 = 16 DMX channels, Pan&Tilt
ENTER
16 bit (Default)
Mode2 = Same fixture as XR7 WASH
MODE 1
16 DMX channels, Pan&Tilt 16 bit
(Please check at page 23 for details)
MENU ENTER DOWNUP
Up-DownENTER
MOTORS TEST
Motors Test
ENTER
ALL ,PAN, TILT, DIMMER, SHUTTER,
COLOUR WHEEL, CYAN, MAGENTA,
ALL
YELLOW,
EFFECTS, ZOOM
MENU ENTER DOWNUP
Up-DownENTER
LAMP
BY DMX
FLIP
BY DMX = ON / OFF via DMX (default)
ALWAYS ON = Forced ON
ALWAYS OFF = Forced OFF
RESET COUNTER = Lamp life time
ENTER
reset
MENU ENTER DOWNUP
LAMP
ADJUST
FLIP
LAMP ADJUST =
with no mixer connected.
It’s possible to set the parameters for
PAN-TILT and ZOOM
To adjust the lamp
ENTER
MENU ENTER DOWNUP
Page 15
13- DISPLAY FUNCTIONS
15
XR1200 WASH
Menu
RESET
Reset via DMX ENABLED / DISABLED
and unit reset
Menu
FAN SPEED
Fan Speed control
Menu
CMY BLACKOUT
CMY filters blades inserted at 100% if the dimmer
remain closed for more than 5 seconds.
By activating this function, it will be possible to
reduce substantially any visible light reflection
coming out from the front lens when dimmer is
closed.
Reset
Up-Down
Fan Speed
Up-Down
CMY Blackout
Up-Down
Up-DownENTER
Up-DownENTER
RESET
BY DMX
ENABLED
MENU ENTER DOWNUP
Up-DownENTER
FAN SPEED
ENABLED = Reset via DMX enabled
(Default)
DISABLED = Reset via DMX disabled
NOW = Unit motors reset
Fan speed control
ENTER
ENTER
1-12 (Default = 12)
12
MENU ENTER DOWNUP
CMY BLACKOUT
ON = Blackout enabled (Default)
ENTER
OFF = Blackout disabled
ON
MENU ENTER DOWNUP
Up-Down
Up-Down
System info
Reserved
Menu
SYSTEM INFO
Lamp life time, lamp strikes, unit life time, 8
motors card software version, Pan&Tilt card
software version and unit model
Menu
RESERVED
Pan lock-Tilt lock
Pan free-Tilt free
System Reboot
(Code = 100)
time, 8 motors card software
version, Pan&Tilt card software
version and unit model
Pan Lock = Lock the Pan to the
desired value
Tilt Lock = Lock the Tilt to the
desired value
ENTER
Pan Free = Remove power to Pan
MENU ENTER DOWNUP
PAN LOCK
NO
motor
Tilt Free = Remove power to Tilt
motor
System Reboot = Unit Reboot
without needing of turning OFF the
unit
MENU ENTER DOWNUP
TILT LOCK
NO
MENU ENTER DOWNUP
PAN FREE
NO
MENU ENTER DOWNUP
TILT FREE
NO
MENU ENTER DOWNUP
REBOOT
MENU ENTER DOWNUP
Page 16
13- DISPLAY FUNCTIONS
16
XR1200 WASH
Up-Down
Up-Down
Default
Frost
Menu
DEFAULT
To restore main settings
Menu
Frost
To be set “ YES” in case FROST filter 0506V016
provided as standard accessory in the box will be
applied on the EFFECT wheel of the unit.
This MENU affect ZOOM excursion
Up-DownENTER
DEFAULT
RESTORE MAIN SETTINGS
MENU ENTER DOWNUP
Default
To restore main settings
ENTER
DEFAULT
RESTORE MAIN SETTINGS
SURE?
PRESS ENTER TO CONFORM
PRESS MENU TO CANCEL
MENU ENTER DOWNUP
Up-DownENTER
FROST
NOT
MENU ENTER DOWNUP
Frost
Not = Not inserted (Default)
Yes = Inserted
ENTER
14- ERROR MESSAGES
ERROR
COLOUR WHEEL
MENU ENTER DOWNUP
COLOUR WHEEL
POSITION ERROR
ERROR
PAN
EFFECTS
MENU ENTER DOWNUP
BEAM SHAPE WHEEL
POSITION ERROR
ERROR
ERROR
TILT
ERROR
ZOOM LEFT
MENU ENTER DOWNUP
LEFT ZOOM SENSOR
POSITION ERROR
ERROR
INTERNAL BUS
ERROR
ZOOM RIGHT
MENU ENTER DOWNUP
RIGHT ZOOM SENSOR
POSITION ERROR
ERROR
DMX ADDRESS
MENU ENTER DOWNUP
PAN REPOSITIONING
ENCODER ERROR
MENU ENTER DOWNUP
TILT REPOSITIONING
ENCODER ERROR
MENU ENTER DOWNUP
COMMUNICATION
PROBLEM BETWEEN 8
MOTORS CARD AND
PAN&TILT CARD
MENU ENTER DOWNUP
DMX ADDRESS
ERROR
Page 17
17
XR1200 WASH
15- HIDDEN MENU
For technical personnel only.
To operate this menu:
-Connect the projector to the DMX controller (DMX SIGNAL MUST BE CORRECTLY RECEIVED)
-Reset the XR1200 (reset from the MENU, not from the DMX controller!).
-While reset is running, press the MENU and ENTER keys at the same time.
CALIBRATION
MOTORS ALIGNMENT
PAN
134
MENU ENTER DOWNUP
ELECTRONIC
CALIBRATION OF THE
MOTORS
Calibration mode
CALIBRATION
MOTORS ALIGNMENT
PAN
134
MENU ENTER DOWNUP
PAN ALIGNMENT
To align pan position
DEFAULT CAL
SET ALL MOTORS AT 128
MENU ENTER DOWNUP
RESET EEPROM.
RESET ALL SETTINGS
TO 128 VALUE
CALIBRATION
MOTORS ALIGNMENT
TILT
167
MENU ENTER DOWNUP
TILT ALIGNMENT
To align tilt position
EXIT TO MAIN
MENU ENTER DOWNUP
EXIT FROM HIDDEN
MENU
CALIBRATION
MOTORS ALIGNMENT
SHUTTER
145
MENU ENTER DOWNUP
SHUTTER ALIGNMENT
To align shutter blades
CALIBRATION
MOTORS ALIGNMENT
COLOUR WHEEL
151
MENU ENTER DOWNUP
COLOUR WHEEL ALIGNMENT
To align colour wheel
CALIBRATION
MOTORS ALIGNMENT
EFFECTS
149
MENU ENTER DOWNUP
EFFECTS ALIGNMENT
To Align Effects wheel
CALIBRATION
MOTORS ALIGNMENT
MAGENTA
121
MENU ENTER DOWNUP
MAGENTA ALIGNMENT
To align magenta colour
CALIBRATION
MOTORS ALIGNMENT
ZOOM RIGHT
97
MENU ENTER DOWNUP
ZOOM RIGHT ALIGNMENT
To align zoom right position
CALIBRATION
MOTORS ALIGNMENT
YELLOW
106
MENU ENTER DOWNUP
YELLOW ALIGNMENT
To align yellow colour
CALIBRATION
MOTORS ALIGNMENT
ZOOM LEFT
85
MENU ENTER DOWNUP
ZOOM LEFT ALIGNMENT
To align zoom left position
CALIBRATION
MOTORS ALIGNMENT
CYAN
162
MENU ENTER DOWNUP
CYAN ALIGNMENT
To align cyan colour
Page 18
18
XR1200 WASH
16- OPENING THE PROJECTOR HOUSING
It is possible to inspect the inside of the projector by removing the cover as indicated below.
ATTENTION
REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR’S INTERNAL COMPONENTS.
1) Loosen the 3 (1/4 turn) screws which fix the head covers (photo 1) .
2) Once unscrewed, simply lift the covers to access the internal components (photo 2).
Photo 1
Photo 2
17- PERIODIC CLEANING
17.1- Lenses and reflectors
Even a fine layer of dust can substantially reduce the luminous output . Regularly clean all lenses
and the reflector using a soft cotton cloth, dampened with a specialist lens cleaning solution.
17.2- Fans and air passages
The fans and air passages must be cleaned approximately every 6 weeks. This periodic cleaning
will depend of course, on the conditions in which the projector is operating. Suitable instruments
for performing this type of maintenance are a brush and a common vacuum cleaner or an air
compressor. If necessary, clean the fans and air passages more frequently.
18- PERIODIC CONTROLS
Attention
Disconnect mains power prior to removing the projector housing.
!
Lamp
The lamp should be replaced if there is any visible damage or deformation due to heat. This will
help to avoid the danger of the lamp exploding. Lamp lifespan is about 750 hours, then it is
necessary to replace it.
Mechanical parts
Periodically check all mechanical parts, gears, guides, belts, etc. for wear and tear, replacing them
if necessary. Periodically check the lubrication of all components, particularly the parts subject to
high temperatures. If necessary, lubricate with suitable lubricant, available from your D.T.S.
distributor. Check the tension of the belts and adjust it if necessary.
Electrical components
Check all electrical components for correct earthing and proper connection of all connectors;
refasten them if necessary.
Fuse replacement
Locate the fuse, which protects the lamp and electronics, in the base of the XR1200.
Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if
necessary.
UV
Page 19
19- DMX PROTOCOL
16 CHANNEL MODE ( 16bit)
1 PAN ms b ( 5 4 0°)
2
3
4 TILT l s b
5
6 D IM MER
7 SHU T T ER
8 C OL OUR
9 C YAN
10 MAGENTA
11 YEL L O W
12 SPEED CMY / DIMMER
13 MACRO CMY / COLOUR
14 E FF ECTS
15 ZOOM
16 RESET
Right rotation speed 5
Right rotation speed 6
Right rotation speed 7
Right rotation speed 8
Right rotation speed 9 min
Stop
Left rotation speed 1 min.
Left rotation speed 2
Left rotation speed 3
Left rotation speed 4
Left rotation speed 5
Left rotation speed 6
Left rotation speed 7
Left rotation speed 8
Full colours rainbow wait = 0
Full colours rainbow wait = 2
Full colours rainbow wait = 3
Full colours rainbow wait = 4
Full colours rainbow wait = 5
Full colours rainbow wait = 6
Full colours rainbow wait = 7
Full colours rainbow wait = 8
Full colours rainbow wait = 9
Full colours rainbow wait = 10
Page 23
-
DMX CHANNEL
DMX range
Value
14
Parameter:
Mid point
DMX value
EFFECTS
Move
range
(degrees)
0-19
20-39
40-255
DMX CHANNEL
DMX range
Value
0-225
DMX CHANNEL
15
Mid point
DMX value
16
Parameter:
ZOOM
Move
range
(degrees)
Parameter: LAMP / RESET
23
XR1200 WASH
Mode Option Function
Standard Frost inserted
No Frost inserted
Beam Shape
Mode Option Function
Proportional
ARC 1200
MODE 1 (DEFAULT)
DMX range
Value
0-9
10-60
61-129
130-179
180-200
201-239
240-255
Mid point
DMX value
30
95
154
190
220
247
Move
range
(degrees)
5
Mode Option Function
No Effect
Lamp OFF (Active after 3 seconds)
No Effect
Lamp ON (Active after 3 seconds)
No Effect
Internal Motors Reset
Total Reset
MODE 2 SAME AS XR 7 WASH (Please check at page 14
“DMX MODE” for details)
DMX range
Value
Mid point
DMX value
0-29
30-85
86 - 170
171-235
236-255
Move
range
(degrees)
Mode Option Function
No effect
Lamp OFF (active after 3
seconds)
Internal motor Reset
Total Reset
Lamp ON (active after 3
seconds)
Page 24
-
20- COLOUR WHEEL
1
2
3
24
4
6
XR1200 WASH
ARC 1200
5
COL1
0507K004
CONV.FILTER CTO
TC3256
8
0507K003
CONV. FILTER CTB
DL542
COL6COL5
7
COL3COL2
0507C046.D01
WOOD SW 460
COL7
COL4
0507C051.D01
ORANGE LW590
COL8
0507C042.D01
GREEN WB5055
0507C047.D01
RED LW 640
0507C041.D01
DARK BLUE SW490
0507C053.D01
AMBER LW 550
Page 25
21- 8 MOTORS CONTROL CARD
8 MOTORS CONTROL CARD
J7 Magnetic Sensors
Connector
Line 1 Brown:
Line 2 Orange:
GND
ORANGE
BROWN
VCC
25
XR1200 WASH
Zoom motor1
(BLACK)
Zoom motor2
(DARK GREEN)
J1 Internal DATA
Communication
Connector
From J8 Pan & Tilt
card
30 VDC
Strobe
(YELLOW)
Colour wheel
(PINK)
+
Effects
(GREY)
-
Magenta
(LIGHT BLUE)
Cyan
(GOLD)
Fans
Yellow
(BLUE)
Fans
Page 26
22-PAN & TILT CARD
ENCODER PAN
(RED)
ENCODER TILT
(ORANGE)
PAN
(WHITE)
26
TILT
(BROWN)
GND
(BLACK)
30 VDC
(RED)
XR1200 WASH
ARC 1200
FAN
(WHITE)
TO J2
LAMP
ON-OFF
CARD
DATA 2
DATA 1
(VIOLET)
(LIGHT GREEN)
(BROWN)
MOTOR TILT
TO J1
DISPLAY CARD
(WHITE)
23-CABLES RESEND CARD
(ORANGE)
ENCODER TILT
25-LAMP ON-OFF CONTROL CARD
TO J1
8 MOTORS CARD
(GREEN)
24-DISPLAY CARD
DMX INPUT
(WHITE)
FROM J12
PAN&TILT
CARD
FROM J16
PAN&TILT
CARD
J2
J4
J3
TO J9
ELECTRONIC
BALLAST
Page 27
NOTES
27
XR1200 WASH
ARC 1200
Page 28
The information contained in this publication has been carefully prepared and checked.
However, no responsibility will be taken for any errors. All rights are reserved and this document
cannot be copied, photocopied or reproduced, in part or completely, without prior written consent
from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its
products without prior notice. D.T.S. assumes no responsibility for the use or application of the
products or circuits described herein.