DTS XR10 SPOT User Manual

GB
Made in Italy
XR10 SPOT
User’s Manual Rel 1.0
D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.it
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S .
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de .
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
D.T.S
D.T.S.
D.T.S.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
D.T.S.
D.T.S.
D.T.S.
ARC 1200
XR10 SPOT
2
3
ARC 1200
INDEX:
1- SYMBOLS 4 2- GENERAL WARNING 4 3- GENERAL WARRANTY CONDITION 4 4- TECHNICAL FEATURES 5 5- ACCESSORIES 7 6- IMPORTANT SAFETY INFORMATION 8
6.1 Fire prevention
6.2 Prevention of electric shock
6.3 Protection against ultraviolet radiation
6.4 Safety
6.5 Level of protection against the penetration of solid and liquid objects 7- MOUNTING THE LAMP 9
7.1 Lamp alignment 8- VOLTAGE AND FREQUENCY 10 9- INSTALLATION 10
9.1 Safety cable
9.2 Protection against liquids
9.3 Movement
9.4 Risk of fire
9.5 Forced ventilation
9.6 Ambient temperature 10- MAINS CONNECTION 11
10.1 Protection 11- DMX SIGNAL CONNECTION 12
11.1 DMX Addresses
11.2 Selecting the DMX address 12- FIRMWARE UPDATING 13 13- DISPLAY FUNCTIONS 14 14- PAN & TILT SPEED 17 15- FANS SPEED 16- ERROR MESSAGES 17 17- HIDDEN MENU 18 18- OPENING THE PROJECTOR HOUSING 19 19- REPLACING GOBOS 20- PERIODIC CLEANING 20
20.1 Lenses and reflectors
20.2 Fans and air passages 21- PERIODIC CONTROLS 22- DMX PROTOCOL 21 23- 8 MOTORS CONTROL CARD 36 24- 6 MOTORS CONTROL CARD 37 25- PAN & TILT CARD 38 26- CABLES RESEND CARD 27- DISPLAY CARD 28- LAMP ON-OFF CONTROL CARD 29- ROTATING GOBO WHEEL 39 30- FIXED GOBO WHEEL 40 31- COLOUR WHEEL 1 41 32- COLOUR WHEEL 2 42
XR10 SPOT
ARC 1200
1- SYMBOLS
Graphic symbols used on this manual
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation , use and maintenance. The device is not for domestic use and must be installed by a qualified electrician or experienced person. Always disconnect the device from the mains before replacing the lamp. The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating. The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 24 months from the date of purchase against manufacturing material defects.
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON INFLAMMABLE SURFACES”
2M
THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT
4
F
THIS SYMBOL MEANS “RADIATION FROM THIS LAMP CAN CAUSE DAMAGE TO EYES AND SKIN”
!
UV
XR10 SPOT
ARC 1200
4- TECHNICAL FEATURES
The XR10 SPOT is a brand new moving head fitted with a 575W discharge lamp,
, which delivers no less than 10.600 Lux at 5 m (12° beam angle).
The XR10 SPOT
The XR10 SPOT is one of the most complete moving heads in the 575W range and is particularly suitable for all professional applications, both mobile (concerts, shows, tours, special events) and fixed (clubs and other venues), requiring a compact light with a very high luminous output and versatility of functions. The XR10 SPOT incorporates motorized focus, motorized iris, motorized linear zoom (10°- 30°), 3-facet rotating prism, frost filter (soft edge). The XR10 SPOT features also a very flexible colour generation, thanks to two colour wheels with 7 colours each, including 3 colour conversion filters (3200°K, 5600°K and 6800°K), with linear selection for perfect 2-colour beams. 2 customizable gobo wheels are available, featuring respectively: 7 rotating and 16 bit indexable gobos; 8 fixed gobos. The XR10 SPOT also includes a new Pan / Tilt locking system with recessed buttons. The XR10 SPOT is the ideal moving head as well for all applications in which quiet operation is required, thanks to its silent internal ventilation system and silent pan/tilt operation.
XR 10 SPOT (Cod. 03.MS010.L)
• Electromagnetic ballast 230V 50/60 Hz • Black colour
XR 10 SPOT (Cod. 03.MS010.EB.L)
• Electronic ballast 90-245V 50/60 Hz • Black colour
Also available with white finish (RAL 9003) on demand. Also available with 120V or 100V power supply (Electromagnetic ballast version)
Lamp
Lamp: Philips MSR 575/2 Automatic switching ON of lamp in case of accidental switching OFF. Lamp ON/OFF via DMX; Reset via DMX.
Optical group
10.600 Lux at 5 m (12°) Dichroic glass reflector
Focus
Motorized focus
Iris
Motorized iris (16 bit)
Zoom
Motorized zoom (12°- 36°)
combined with a
dichroic parabolic reflector
is fitted with a Philips MSR 575/2 discharge lamp (GX9,5 lampholder base), with a
colour temperature of 7,200 °K and a luminous flux of 49,000 Lumens.
5
XR10 SPOT
4- TECHNICAL FEATURES
Dimmer / shutter / strobo
Linear dimmer Shutter Strobe from 0,85 flash/sec to 6,75 flash/sec Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Colours
2 Colour wheels (7 colours + open with linear selection) 3200°K and 5600°K colour conversion filters Colour change with blackout sync; rainbow effect
Gobos
2 gobo wheels: 1 rotating (7 indexable 16 bit gobos + open) and 1 fixed (8 gobos + open) Extractable gobo holders for both wheels Gobo change with synchronized blackout Gobo scrolling; Gobo shake
Effects
Indexable prism rotating in both directions (3-facet) Wash effect filter
Pan / Tilt
Pan 540° (3,9 sec.) Tilt 270° (2,6 sec.) 16-bit resolution 2-Speed function (2 selectable pan/tilt speeds); extremely smooth and precise movements even at the highest speeds Pan / Tilt locking system with recessed buttons Automatic Pan/Tilt repositioning in case of knocks
25 DMX channels (Default)
Internal operating system updatable via DMX
Connections
4 XLR connectors (3-pole In and Out; 5-pole In and Out) by Neutrik POWERCONN connector by Neutrik
Power supply
Electronic ballast: 90 - 245 V (50/60 Hz) Electromagnetic ballast: 230 V (50/60 Hz)
Power consumption: 750 W Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Thermal
Operating ambient temperature: -10° / 40°
Weight
On request: 100 V 50-60 Hz /120 V 60 HZ
26 Kg (electronic ballast) 32 Kg (magnetic ballast)
ARC 1200
6
XR10 SPOT
4- TECHNICAL FEATURES
Dimensions
5- ACCESSORIES
As standard
•1 x MSR 575/2 lamp
•1 x POWERCONN male cable connector (cod. 0520P014)
•1 x XLR 5 Pins male cable connector (cod. 0508B028)
•1 x XLR 5 Pins female cable connector (cod. 0508B027)
•2 x “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• User’s manual
Optional (on request)
• Raincover for XR base (top) (cod. 03.MA001)
• Raincover for XR base (bottom) (cod. 03.MA002)
• Embedding flange for XR (visible display) (cod. 03.MA005)
• Embedding flange for XR (no visible display) (cod. 03.MA006)
• Wireless DMX receiver card (cod. 03.LA.012)
• “C” Clamp G60 black (max. load 50Kg) (cod. 0521A004)
• “C” Clamp G60 chrome (max. load. 50Kg) (cod. 0521A004.20)
• “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• “C” Clamp G100 black / professional (max. load. 200Kg) (cod. 0521A015)
• Omega clamp with “Fast Lock” connection 1⁄4 turn (Cod. 02K00467)
• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (cod. 0521A010)
Unit Dimensions (LxWxH) 525x500x810mm 26 Kg (Electronic ballast) 32 Kg (Electromagnet ballast)
Packaging Dimensions (LxWxH) 610 x 540 x 720 mm 31,5 Kg (Electronic ballast) 37,5 Kg (Electromagnet ballast)
ARC 1200
7
408 mm
625 mm
500 mm
415 mm
18 0
mm
525 mm
270°
XR10 SPOT
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
MSR lamp
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1.5 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XR10 SPOT requires the assistance of specialised personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering are damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
6.5 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20. For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR base (top) (cod. 03.MA001)
• Raincover for XR base (bottom) (cod. 03.MA002)
XR10 SPOT uses a PHILIPS 575/2 (other reccomended lamps: Philips 575 MSD).
ARC 1200
2M
8
F
!
!
UV
XR10 SPOT
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
2) .
3) . The lamp used on XR10 SPOT is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging. . DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
4) . WARNING: Never look directly at the lamp when it’s lit. Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic filters and other components inside the unit. The lamp alignment is also essential to obtain the maximum unifirmity and luminous performance by the projection.
3 adjusters X, Y and
Z (photo 5)
you will have an evenly projected light beam, with no shadows or
zones wich are brighter than others.
Remove the lamp holder assembly (photo2)
)Insert the lamp (photo 3)
The GX9,5 lamp socket is symmetrical
Replace the lamp assembly and tighten the screws A,B,C, which were previously removed (Photo4)
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
until you achieve a uniform flat field.
When the lamp is correctly optimized,
ARC 1200
Photo 2Photo 1 Photo 4Photo 3
Photo 5
9
Lamp
Alignment
UV
XR10 SPOT
Philips 575 MSR/2 Power 575W Luminous flux 49,000 lm Colour temperature 7.200°K Lampbase GX9,5 Rated life 1,000 hours
Philips 575 MSD Power 575W Luminous flux 43,000 lm Colour temperature 6.000°K Lampbase GX9,5 Rated life 3,000 hours
8- VOLTAGE AND FREQUENCY
The XR10 SPOT with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
XR10 SPOT may be either floor or ceiling mounted. For floor mounting installations, the XR10 SPOT is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hang it. The structure should also be sufficiently rigid so as not to move or shake whilst the XR10 SPOT is moving. Four quarter turn fast locks placed on the base of the units, allows by using the two fast lock C clamps provided in the box, to fix the unit in any position. .
9.1- Safety cable
We recommend the use of a safety cable connected to the XR10 SPOT and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable can bear the weight of the entire unit. You may attach the safety cable to the two holes (A) located on the base of the fixture, as shown in the picture below.
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
The XR10 SPOT with electromagnetic ballast can operate at 230 VOLT 50 or 60 Hz (Standard).
On request: 100 V 50-60 Hz /120 V 60 HZ.
A
ARC 1200
!
240 mm
105 mm
10
XR10 SPOT
9.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement.
9.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
9.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
9.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
10- MAINS CONNECTION
XR10 SPOT with electronic ballast operate at 90-260 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 6,3 amps at 230V, Or12 amps at 100-120 V Strict adherence to regulatory norms is strongly recommended.
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR10 SPOT. A good earth connection is essential for the correct operation of the projector.
XR10 SPOT with electromagnetic ballast operate at 230 VOLT 50-60 Hz
(On request: 100 V 50-60 Hz /120 V 60 HZ).
540°
270°
ARC 1200
11
2M
F
Fuse Holder
(12A T 5x20 Fuse)
!
WARNING
Do not place any object in the path
of the projector’s movement
XR10 SPOT
Electronic ballast 90-260V 50 / 60Hz Electromagnetic ballast 230 V 50/60 Hz (standard)
On request: 100 V 50-60 Hz 120 V 60 HZ
11- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR 5 or 3 pins connector. Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassy The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one. In this way, all the projectors are cascade connected. NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
For Installations where long distance DMX cable connections are needed, we suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
ARC 1200
12
5
3
4
2
1
1=GND 2=DATA­3=DATA+
CONTROLLER S T AN D A R D D M X 5 1 2
XR10 SPOT
11.1-DMX Addresses
XR10 SPOT can be controlled with 18, 25 (default) or 26 DMX channels. If you want to use the unit in 25 channels mode (default), set the following addresses on the mixer:
Projector 1 A001 Projector 2 A026 If you want to select the next projector, just add “25”
11.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now setted to the new DMX address.
TRICKS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
Projector 3 A051 ….. A…. projector 6 A126
12 FIRMWARE UPDATING
Warning: This procedure require a base knolewge of computer applications and Windows Hyperterminal program.
To update the software version of the XR10 SPOT you need: D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008). USB-DMX Driver for the D.T.S. RED BOX interface . (The driver and the installation procedure are available in our web site www.dts-lighting.it) Updated software version. Please follow the below procedure to perform the updating:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using Windows Hyperterminal program.
It will be possible to download the software from the reserved area of D.T.S. web site: www.dts-lighting.it.
Please refer to an authorised DTS service centre.
ARC 1200
13
!
XR10 SPOT
13- DISPLAY FUNCTIONS
DISPLAY FUNCTIONS
The XR10 SPOT display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the DTS setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Up-DownMENU ENTERUp-Down
PAN MOVEMENT INVERSION To reverse Pan movement from left to right and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTERUp-Down
TILT MOVEMENT INVERSION To reverse Tilt movement from bottom upwards and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTER
DMX MODE To select DMX mode : 25 (default), 26 or18 DMX channels
25 CHANNELS
(Pan & Tilt 16 bit)
18 CHANNELS
(Pan & Tilt 16 bit)
Up-Down
Up-Down
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
Up-Down
MENU
ENTERUp-Down
REVERSE DISPLAY Reverses display's reading depending on the mounting position (On the ground or suspended).
Up-Down
Floor
position
Suspension
position
Up-DownENTER
Up-DownENTER
DISPLAY STAND BY To turn off the display (after 5 seconds) Or leave it always on.
Display OFF
Display
always ON
ENTER
ENTER
ENTER
ENTER
DMX IN
DMX OUT
DISPLAY
MENU
ENTER
DOWN
UP
FUSE
12 A T 5x20
ARC 1200
14
DMX IN
DMX OUT
Default
Same fixture as XR9 SPOT
26 CHANNELS
(Pan & Tilt 16 bit)
Mains Electronic ballast: 90-260V 50 / 60Hz Electromagnetic ballast: 230 V 50/60 Hz (standard)
On request: 100 V 50-60 Hz 120 V 60 HZ
XR10 SPOT
Loading...
+ 30 hidden pages