DTS XM 2500 Sport, XM 2500 SPOT User Manual

XM 2500 SPOTXM 2500 SPOT
GB
User Manual Rel 1.0
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. DTS non assume alcuna responsabilità sull'uso o sull'applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de DTS.
DTS se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou de
design, sans préavis, à chacun de ses produits. DTS décline toute responsabilité sur l'utilisation ou sur
l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas.
Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes. Todos los derechos han
sido reservados y este documento no puede ser copiado, fotocopiado o reproducido, total o
parcialmente, sin previa autorizaciónescrita de DTS.
DTS se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter estético,
funcional o de diseño a cada producto suyo. DTS no se asume responsabilidad de ningún tipo sobre la
utilización o sobre la aplicación
de los productos o de los circuitos descritos.
ARC 1200
XM 2500 SPOT
2
INDEX:
1- TECHNICAL FEATURES 4 2- IMPORTANT SAFETY INFORMATION 5
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid matter
3- MOUNTING THE LAMPS 6
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY 7 5- INSTALLATION 7
5.1 Safety chain
5.2 Protection against liquids
5.3 Movement
5.4 Risk of fire
5.5 Forced ventilation
5.6 Ambient temperature
6- MAINS CONNECTION 8
6.1 Protection
7- DMX SIGNAL CONNECTION 8
7.1 DMX Addresses
7.2 Selecting the DMX address
8- DISPLAY FUNCTIONS 11 9- ERROR MESSAGES 14 10- HIDDEN MENU 15 11- OPENING UP THE PROJECTOR HOUSING 17
12- REPLACING GOBOS
13- PERIODIC CLEANING 18
13.1 Lenses and reflectors
13.2 Fans and air passages
13.3 Periodic controls
14- CONTROL MOTORS CARD 19 15- DISPLAY CARD 21 16-PAN & TILT CARD 17- LAMP ON-OFF CONTROL CARD 18-CABLES RESEND CARD 19- DMX PROTOCOL 22
ARC 1200
3
XM 2500 SPOT
ARC 1200
4
1- TECHNICAL FEATURES
The XM 2500 Spot is fitted with a Philips MSR 1200/SA discharge lamp (GY22 lampholder base), with a colour temperature of 5,600 °K and a luminous flux of 96,000 Lumens. Duration is 750 hours, with replacement recommended before 1000 hours Other recommended lamps: Osram HTI 1200W/SE PP; GE Lighting CSR1200W SA
The unit incorporates: Motorized Focus system 8°-13° motorized Zoom with auto-focus Dimmer (emitted light is controlled by progressive and linear dimming). Shutter (instantaneous shutter opening/closure) Strobe: mechanical strobe effect (frequency variable from 0.86 flashes/sec to 6.6 flashes/sec). Motorized iris 2 gobo wheels (6 indexable 16 bit gobos + open each) CMY linear colour mixing system Colour wheel (7 colours + open) 3 rotating prisms Frost Electronic or magnetic ballast Pan: 540° in 5.6 seconds (8 or 16 bit) with auto repositioning system Tilt: 270° in 4.3 seconds (8 or 16 bit) with auto repositioning system USITT Standard DMX 512 input 4-digit LED display with 4 buttons Power Supply: 190-245 V (50/60 Hz). Power consumption: 1300 W. Energy saving function is automatic when the fixture is blacked out. The XM 2500 SPOT is also available with a magnetic ballast, with selectable power supply (220/230/240 V). Power consumption is 1300 W. Remote Lamp on/off via DMX Net weight: 45 Kg (with electronic ballast); 55 Kg (with magnetic ballast).
Packaging Dimensions (LxWxH)
680x680x780mm Weight: 50 Kg (with electronic ballast) 60 Kg with magnetic ballast
XM 2500 SPOT
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
-XM2500 is fitted with a Philips 1200W MSR/SA lamp.
-Other recommended lamps are: Osram HTI 1200W/SE PP; GE Lighting CSR1200W SA The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 m.
-Minimum distance from the closest illuminable surface: 1 m.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XM2500 requires the assistance of specialised personnel for all servicing.Please refer to an authorised D.T.S. service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety chain to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid matter is IP 20. XM2500 uses Philips 1200 MSR/SA lamp with GY 22 socket. The temperature inside the projector can reach 250° C after just 5 minutes, but it can get as high as 350° C. Always check that the lamp is cold before attempting to remove it. In any case, only open the unit 10 minutes after it has been turned off
ARC 1200
5
XM 2500 SPOT
3- MOUNTING THE LAMPS:
Warning: Switch off the unit before replacing the lamp.
Philips MSR1200/SA Power 1200W Luminous flux 96,000 lm Colour temperature 5.600°K Lamp base GY 22 Rated life 800 hours
1) Using a screwdriver, remove the 4 screws (A,B, C,D) (photo 1) which fix the lamp holder.
2) Remove the lamp holder assembly (photo2). Insert the lamp (photo 3). The lamp used on XM 2500 is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging. The GY22 lamp socket is not symmetrical. DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
3) Replace the lamp assembly and tighten the screws (A,B,C,D) which were previously removed (photo
4).
3.1 Lamp alignment:
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic filters and other components inside the unit.
Alignment is carried out using the 3 adjusters X, Y and Z. During this operation you must have a uniform luminosity all around the projected area.
Osram HTI 1200W/SE PP Power 1200W Luminous flux 105,000 lm Colour temperature 5.400°K Lamp base GY 22 Rated life 750 hours
ARC 1200
6
Photo 2Photo 1 Photo 4Photo 3
GE Lighting CSR1200W SA Power 1200W Luminous flux 100,000 lm Colour temperature 5.800°K Lamp base GY 22 Rated life 750 hours
Photo 5
XM 2500 SPOT
4- Voltage and frequency
The XM2500 E.B.(ELECTRONIC BALLAST) can operate at 190-245 VOLT 50 or 60 Hz.
5- Installation
XM2500 may be either floor or ceiling mounted. For floor mounting installations, the XM2500 is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hang it. The structure should also be sufficiently rigid so as not to move or shake whilst the XM2500 is moving. Eight quarter-turn fast locks placed on the base of the units allow - by using the two Omega Clamps provided in the box - to fix the unit in any position. .
Safety chain
We recommend the use of a safety cable or chain connected to the XM2500 and to the suspension truss in order to avoid the fixture accidental fall, should the main fixing point fail. Make sure that the iron cable or chain can bear the weight of the entire unit. You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the picture below.
Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
A
ARC 1200
7
XM 2500 SPOT
quarter turn fast locks
quarter turn fast locks
Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement.
Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 0.5m. Minimum distance from the object being illuminated is 2 m.
Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
6- MAINS CONNECTION
XM2500 operates at 190-245V at 50 or 60Hz. Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is of a suitable rating of 8 amps at 230V.
Strict adherence to regulatory norms is strongly recommended.
Protection
The use of a thermal magnetic circuit breaker is recommended for each XM2500. A good earth connection is essential for the correct operation of the projector.
7- DMX signal connection
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø0.5 mm cable and a CANNON XLR 5 or 3 pole connector.
190-245V 50 / 60Hz
ARC 1200
8
540°
270°
XM 2500 SPOT
Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassy. The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one. This way all the projectors are cascade connected. NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
The standard configuration of the XM2500 is with XLR 5 pins connection. To convert to an XLR 3 pins configuration proceed as follows:
1) Remove the 4 screws fixing the display cover panel to the unit (photo 1).
2) Remove the screws that fix the XLR connectors to the panel (photo 2).
3) Rotate the electronic card by 180° (photo 3).
4) Place the 3 pins XLR connectors in the special holes and close.
For Installations where long distance DMX cable connections are needed,we suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor between pin 2 and 3. The DMX terminator must be plugged in the last unit (DMX out panel connector) of the DMX line.
Photo 2Photo 1 Photo 3
5
3
4 2
1
1=GND 2=DATA­3=DATA+
CONTROLLER STA N D A R D DM X 5 1 2
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
9
XM 2500 SPOT
DMX Addresses
XM2500 can be used in two different modes: 30 or 18 DMX channels. If you want to use the XM2500 in 18 channels mode, select the 18 CH mode from the MODE menu and
set the following addresses on the mixer: Projector 1 A001
Projector 2 A019 If you want to select the next projector, just add “18” Projector 3 A037
….. A…. projector 6 A073
If you want to use the XM2500 in 30 channels mode, select the 30 CH mode from the MODE menu and set the following addresses:
Projector 1 A001 Projector 2 A031 If you want to select the next projector, just add “30”
Projector 3 A061 ….. A…. Projector 6 A151
Changing the DMX address
1) Press the UP-DOWN key until you reach the required DMX number. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.
TRICKS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
Pushing UP and DOWN keys together,will set the DMX address to channel 001.
ARC 1200
10
XM 2500 SPOT
DMX IN
DMX OUT
DISPLAY
MAINS
190-245V ~ 50-60 Hz
8- DISPLAY FUNCTIONS
ARC 1200
11
MENU
ENTER
DOWN
UP
DISPLAY FUNCTIONS
The XM2500 display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Up-DownMENU ENTERUp-Down
PAN MOVEMENT INVERSION To reverse Pan movement from left to right and vice versa on DMX level variation.
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTERUp-Down
TILT MOVEMENT INVERSION To reverse Tilt movement from bottom upwards and vice versa on DMX level variation
Up-Down
Up-Down
MENU
ENTERUp-Down
REVERSE DISPLAY Reverses display's reading depending on the mounting position (On the ground or suspended).
Up-Down
Floor
position
Counterclockwise
Clockwise
Suspension
position
Up-DownMENU ENTER
DMX MODE To select DMX mode : 30-18 channels
30 CHANNELS (Pan & Tilt 16 bit)
18 CHANNELS (Pan & Tilt 16 bit)
Up-Down
Up-Down
Up-DownENTER
Up-DownENTER
DISPLAY STAND BY To turn off the display (after 5 seconds) Or leave it always on.
Display OFF
Display
always ON
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
XM 2500 SPOT
Loading...
+ 25 hidden pages