DSC Maxsys PC4116 Installation Instructions Manual

PC4116 Zone Input Module
Installation Instructions
1. Introduction
The PC4116 is a zone input module that adds up to 16 fully programmable zones to the Maxsys security system.
2. Specifications
• Connects to control panel via 4-wire Combus
• Supports no end-of-line, single end-of-line and double end-of-line zone loops (5600 ohm resistors)
• AUX+ output: 12V
DC, 250mA max. (drawn from
Combus)
• Tamper contact input
Compatible Cabinets
• PC4051C/CR*
• PC4001C
• PC4054C *CR cabinet for North American customers only
3. Installing the PC4116
3.1 Unpacking
The PC4116 package includes the following parts:
• One PC4116 circuit board
• 32 end-of-line resistors (5600 ohms)
• Five plastic stand-offs
3.2 Mounting
The PC4116 should be located inside a compatible cabinet, mounted in a dry, secure location. Preferably, it should be placed at a convenient distance from the connected devices.
Perform the following steps to mount the unit:
1. Press the five plastic stand-offs through the mounting holes at back of the cabinet.
2. Secure the cabinet to the wall in the desired location. Use appropriate wall anchors when securing the cabinet to drywall, plaster, concrete, brick or other surfaces.
3. Press the circuit board into the five plastic stand-offs to secure the unit to the cabinet.
Once the unit is mounted, wiring may be completed.
3.3 Installation and Wiring
Before beginning to wire the unit, ensure that all power (AC transformer and battery) is disconnected from the control panel.
Perform the following steps to complete wiring:
1. Connect the four Combus wires to the PC4116. Connect the red, black, yellow and green Combus wires to the RED, BLK, YEL and GRN terminals, respectively.
2. Complete all zone wiring to the zone input terminals (Z1-Z16). See the control panel Installation Manual for details on zone wiring configurations.
3. Connect the external tamper switch, if used.
Consult the wiring diagram above for further information.
3.4 Applying Power
After all wiring is completed, apply power to the control panel. Connect the battery leads to the battery, then connect the AC transformer. For more information on control panel power specifications, see the control panel Installation Manual.
NOTE: Do not connect the power until all wiring is complete.
4. Enrolling the Module
Once all wiring is complete, the module must be enrolled on the system. To enroll the module, perform the following:
1. Enter installer’s programming by pressing [*] [8] [Installer’s Code].
2. Scroll to “Module Hardware” and press the [*] key.
3. Scroll to “Enroll Module” and press the [*] key.
4. Scroll through the different modules until “PC41XX” is displayed. Press the [*] key.
5. The message “Create Tamper on Desired Unit” will be displayed. To create the required tamper, secure the tamper zone on the module and then open it. The transition from secure to violated enrolls the module. After this is done, the keypad will display the module number and will confirm enrollment (e.g. “PC4116 Mod 01 Enrolled”).
Zones 1-8 (PC4010)/1-16 (PC4020) are located on the main control panel. Additional zones are added in sequence. For example, if two PC4116 zone expanders are enrolled, the first one enrolled will be assigned zones 17 to 32 and the second will be assigned zones 33 to 48. To confirm which zones are assigned to which expander, press the arrow key when the enrollment confirmation message is displayed.
For more information regarding module enrollment, see the control panel Installation Manual.
5. Programming the Module
To access PC4010/4020 programming, enter [*][8] followed by the Installer’s code. The zones connected to the module must be added to a partition and programmed for operation. The programming worksheet located on this sheet indicates which sections must be programmed.
For more information regarding zone programming, see the control panel Installation Manual.
NOTE: The zone types and attributes listed below are for PC4010/4020 v3.0. For zone programming for previous software versions, see the corresponding programming manual.
Please refer to the System Installation Manual for information on limitations regarding product
use and function and information on the limitations as to liability of the manufacturer.
Security Products
TM
©1998 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6
(416) 665-8460 • Fax (416) 665-7498 • 1-800-387-3630 Printed in Canada 29000297 R5
System Partition
Zone 1 2 3 4 5 6 7 8 Zone Label Zone Type A1 A2 A3 A4 A5 A6 A7 A8
1. _ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
2.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
3.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
4.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
5.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
6.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
7.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
8.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
9.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
10.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
11.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
12.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
13.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
14.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
15.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
16.
_ _ _ I
______I______I______I______I______I______I______I______II______I______I______I______I______I______I______I______I______I______I______I______I______I______II______I______II______I______I______I______I______I______I______I______
I
Zone Assignment
[Partition Area > Add/Edit Par]
XX= Partitions 01-08 (PC4020) 01-04 (PC4010)
[0100XX0300] Add New Zone
[0100XX0301] Edit Zone
[0100XX0302] Delete Zone “ZONE XXX”
Zone Attribute Defaults
A1 A2 A3 A4 A5 A6 A7 A8
[00] Standard Delay ............................. YNYYNYNN
[01] Auxiliary Delay ............................. YNYYYYNN
[02] Instant ............................................. YNY YNYNN
[03] Interior ............................................ YNYNNYNN
[04] Interior Delay ................................ YNYNNYNN
[05] Int Stay Away ................................ YNYNYYNN
[06] Delay Stay Away .......................... YNYNY YNN
[07] Standard Fire ................................. YYNNNNNN
[08] Delayed Fire .................................. Y YNNNNNN
[09] Auto Ver Fire ................................. YYNNNNNN
[10] Waterflow ...................................... Y YNNNNNN
[11] Fire Supervis. ................................. NYNNNNNN
[12] 24 Hr Bell ....................................... YNYNNNNN
[13] 24 Hr Bell/Buzz ............................ YNY NNNNN
[14] 24 Hr Buzzer .................................. YNYNNNNN
[15] 24 Hr Technical ............................. NNNNNNNN
[16] 24 Hr Gas ....................................... Y NY NNNNN
[17] 24 Hr Heat ..................................... Y YNNNNNN
[18] 24 Hr Medical ................................ NNY NNNNN
[19] 24 Hr Emergency .......................... YNY NNNNN
[20] 24 Hr Water ................................... YNY NNNNN
[21] 24 Hr Freeze .................................. YNY NNNNN
[22] 24 Hr Holdup ................................ NNNNNNNN
[23] 24 Hr Panic .................................... NNNNNNNN
[24] Latching 24 Hr .............................. Y NNNNNNN
[25] Momentary Arm ........................... YNNNNNNN
[26] Maintained Arm ........................... YNNNNNNN
[27] Forced Answer .............................. NNY NYNNN
[28] Links Supervis. .............................. NNYNYNNN
[29] Links Answer ................................ NNYNYNNN
Zone Attributes:
A1=Bell Audible
A2=Bell Pulsed
A3=Bypass Enabled
A4=Chime Function
A5=Force Arm
A6=Swgr Shut Down
A7=TX Delay
A8=Waterflow Del
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient the receiving antenna
Relocate the alarm control with respect to the receiver
Move the alarm control away from the receiver
Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4.
This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la Classe B respecte toutes les exigences de règlement sur le matériel brouilleur du Canada.
Loading...