Dräger SAM 3100, SAM 3200 Instructions For Use Manual

Dräger SAM 3100 / 3200 Sampling system
Instructions for Use
Contents
1 For your safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Definitions of alert icons . . . . . . . . . . . . . . . . . . . . . .4
2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.1 Air quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.2 Standard system without delivery unit . . . . . . . . . . .5
4.3 System with ejector unit . . . . . . . . . . . . . . . . . . . . . .5
4.4 System with gas sampling pump . . . . . . . . . . . . . . .5
4.5 Circuit breaker (option) . . . . . . . . . . . . . . . . . . . . . . .5
4.6 Motor circuit protector (option) . . . . . . . . . . . . . . . . .6
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5.1 Mechanical fastening . . . . . . . . . . . . . . . . . . . . . . . .6
5.2 Installing gas lines . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5.3 Electrical connections . . . . . . . . . . . . . . . . . . . . . . . .7
6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7.1 Wiring diagram for PEX 3000 . . . . . . . . . . . . . . . . . .9
7.2 Wiring diagram for Polytron 3000 / Polytron 7000 . .10
7.3 Wiring diagram for PIR 7000 / PIR 7200 . . . . . . . . . 11
8 List of materials . . . . . . . . . . . . . . . . . . . . . . . . . .12
Contents
Dräger SAM 3100/3200 3
For your safety
!
!
!

1 For your safety

1.1 General safety notes

Before using this product, carefully read the Instructions
for Use.
Strictly follow the Instructions for Use. The user must fully
understand and strictly observe the instructions. Use the product only for the purposes specified in the Intended use section of this document.
Do not dispose of the Instructions for Use. Ensure that they
are retained and appropriately used by the product user.
Only trained and competent users are permitted to use
this product.
Comply with all local and national rules and regulations
associated with this product.
Only trained and competent personnel are permitted to
inspect, repair and service the product as detailed in these Instructions for Use (see section 6 on page 8). Further maintenance work that is not detailed in these Instructions for Use may only be carried out by Dräger or personnel qualified by Dräger. Dräger recommends a Dräger service contract for all maintenance activities.
Use only genuine Dräger spare parts and accessories,
or the proper functioning of the product may be impaired.
Do not use a faulty or incomplete product. Do not modify
the product.
Notify Dräger in the event of any component fault or failure.
Safe connection to electrical devices
Electrical connections to devices which are not listed in
these Instructions for Use should only be made following consultation with the respective manufacturers or an expert.
Use in potentially explosive atmospheres
WARNING
The equipment is only approved for use in potentially explosive atmospheres when using components suitable for such areas, complete with test certificate. Risk of explosion!
Devices or components for use in potentially explosive
atmospheres, which have been tested and approved according to national, European or international Explosion Protection Regulations, may only be used under the conditions specified in the approval and with consideration of the relevant legal regulations. The devices or components may not be modified in any manner. The use of faulty or incomplete parts is forbidden. The appropriate regulations must be observed at all times when carrying out repairs on these devices or components.

1.2 Definitions of alert icons

The following alert icons are used in this document to identify and highlight areas of the associated text that require a greater awareness by the user. A definition of the meaning of each icon is as follows:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
!
Indicates a potentially hazardous situation which, if not avoided, could result in physical injury, or damage to the product or environment. It may also be used to alert against unsafe practices.
NOTICE
i
i
Indicates additional information on how to use the product.

2 Intended use

The Dräger SAM 3100/SAM 3200 is an aspirator system for continual intake of gas/air mixtures for a gas transmitter (SAM 3100) or for two gas transmitters (SAM 3200), in order to carry out measurements of toxic and/or explosive substances in hard-to-access places.
In the event of insufficient process overpressure, a partial flow
of the process gas is siphoned off from the process using a gas sampling pump with electric drive, or alternatively using an ejector.
In order to separate solid particles from the gas flow,
the gas is passed across a filter.
The sample gas is passed to the flow meter with ring
initiator (for flow monitoring) via a 3/2-way spherical valve (option for simplified feeding of test gas) and then flows into the sample chamber of the sensor or sensors.
The air is either discharged to atmosphere or fed back
to the intake point by means of the air outlet on the transmitter.
WARNING
During installation without return feed for the sample gas back to the intake point, the sample gas should be guided to a vent or outside. Risk of poisoning or explosion! The return feed must not be pressurised.
4 Dräger SAM 3100/3200
Specification
!
Example arrangements
Dräger SAM 3100 without gas sampling pump:
1 Dräger PIR 7000 gas transmitter with process adapter 2 Sample gas outlet 3 Flow meter with ring initiator (flow monitoring at 25 to 250 l/h) 4 3/2-way calibrating gas valve 5 Analysis filter (filter element 1 µm PTFE) 6 Sample gas inlet 7 Dräger Polytron 7000 gas transmitter with adapter for
gas exposure
8 Gas sampling pump
Dräger SAM 3200 with gas sampling pump:

3 Specification

Ambient temperature: +10 to +40 °C Protection class: IP 20 (standard
Flow meter with ring initiator
Flow monitoring:
Standard: 10–100 l/h Optional: 6–60 / 25–250 l/h
Material: PVDF
Sample gas lines
Material: Screw connections:
Gas sampling pump (option)
Power supply: 230 V / 50 Hz Pumping rate: approx. 5.5 l/min.
Ejector (option)
Material: Stainless steel Compressed air supply: 4 bar to 6 bar
configuration without housing)
PVDF Hose: PTFE

4 Settings

4.1 Air quantity

The flow should be set according to the sensor type:
Transmitter with electrochemical sensor ~60 l/hTransmitter with electrochemical sensor + IR transmitter
in series ~80 l/h
IR transmitter ~180 l/h
The flow should be matched to the circumstances in the system as a whole.

4.2 Standard system without delivery unit

The sample air leaves the process with excess pressure!
The sample gas flow should be set to 60 l/h at the fine
regulating valve on the flow meter. The top of the ball is the read mark for the scale.
Notice on handling: see the Instructions for Use for the
flow meter.

4.3 System with ejector unit

To function correctly, the regulating valve needs an input
pressure of 1 bar to 10 bar. The control range of the regulating valve is 0.2 bar to 10 bar.
Setting the sample gas flow:Open the fine regulating valve on the flow meter (turn anti-
clockwise to the stop, then 1 turn back).
Set the flow approximately at the regulating valve, then carry
out the fine regulation using the regulating valve on the flow meter . The top of the ball is the read mark for the scale.
Notice on handling: see the Instructions for Use for the
flow meter and for the regulating valve.

4.4 System with gas sampling pump

The sample gas flow should be set to 60 l/h at the fine
regulating valve on the flow meter. The top of the ball is the read mark for the scale.
Setting the sample gas flow:Open the fine regulating valve on the flow meter (turn anti-
clockwise to the stop, then 1 turn back), set the flow approximately at the bypass valve on the gas sampling pump, then carry out the fine regulation using the regulating valve on the flow meter. The top of the ball is the read mark for the scale.
Notice on handling: see the Instructions for Use for the
flow meter and for the gas sampling pump.
Regulating valve (option)
Input pressure: 1 bar to 10 bar Control range: 0.2 bar to 10 bar
3/2-way spherical valve (option)
Material: Stainless steel
WARNING
The equipment is only approved for use in potentially explosive atmospheres when using components suitable for such areas, complete with test certificate. Risk of explosion!
Test certificates are included in the equipment documentation.

4.5 Circuit breaker (option)

The circuit breaker is delivered together with the aspirator
system as a separate item. Installation is carried out on site by the operator in accordance with the assembly instructions. Information is included in the documentation.
The circuit breaker makes it possible to monitor line breaks
and short circuits. Furthermore, the action of the relay can be reversed by means of a switch. Settings should be adjusted in accordance with the operator's requirements during commissioning. Information is included in the documentation.
Standard: Auxiliary power 24 V DCOptional: Auxiliary power 230 V, 50 Hz
Dräger SAM 3100/3200 5
Installation
00423944_01.eps
123 4 5
00523944_01.eps
00623944_01.eps
00723944_01.eps

4.6 Motor circuit protector (option)

The motor circuit protector is delivered together with
the aspirator system as a separate item.
Adjustment range 0.25 to 0.4 A.Using a screwdriver, set the value in accordance with
the rating plate on the motor of the gas sampling pump (Ex pump 0.3 A, non-Ex pump 0.4 A).
Installation is carried out on site by the operator in
accordance with the assembly instructions. Information is included in the documentation.

5 Installation

5.1 Mechanical fastening

The Dräger SAM 3100 / 3200 aspirator system is delivered
fully assembled.
The installation of the base plate or housing depends on
the local situation. Ensure that the installation is sufficiently firm and free of vibration.
Connect the intake side to the hose laid by the customer,
using the compression fitting for a hose of 6 x 1 mm (see section 5.2 on page 6).
The exhaust line is 6 x 1 mm as standard.For exhaust lines more than 10 m in length, the cross-
sections should be expanded by the customer from the outlet of the aspirator system in order to prevent pressure build-up in the system.
Assembly instructions for PTFE hose connection
1 Screw-in piece 2 Nozzle 3 Clamping ring 4 Lock nut 5Hose
Slide the lock nut and clamping ring over the hose
as illustrated.
Slide the end of the hose over the nozzle to the stop.

5.2 Installing gas lines

The gas lines may only be connected by skilled personnel.
Local legislation and regulations must be observed.
When selecting gas lines (material, length), consider potential
adsorption effects.
When designing the length of the intake line, bear in mind
that a longer line will lengthen the alarm lag time.
Recommended hose material: PTFE (Teflon) or PE,
depending on the chemical resistance to the target gas.
When using other hose materials or diameters, a transition
to 6 x 1 mm PTFE hose must be created.
Cut off hose squarely!
Screw in the lock nut by hand until it is hand-tight.
To open the hose connection, unscrew the union nut and
remove the hose, together with the clamping ring, from the aspirator system.
For air containing dust, an intake filter (order no. 68 06 743)
should be provided at the intake point to protect the aspirator system and the line.
Avoid external influences such as splashing water, oil etc.
and the possibility of mechanical damage.
Pay attention to ventilation!Always locate the intake point in the air flow between
a potential discharge or collection point and points of potential hazard.
Pay attention to the density of gas!For gases with a density lower than that of air, the intake
point must be located above any possible leak or at the highest point at which large concentrations of gas may occur. For gases and vapours with a density greater than that of air, the intake point must be located below a possible leak or at the lowest point at which such gases and vapours may occur.
Pay attention to the seal of the gas connections, as leaks
can cause significant measuring errors to occur at the gas transmitter.
When testing the seal, no overpressure or underpressure
should be generated at the sensor!
6 Dräger SAM 3100/3200

5.3 Electrical connections

!
CAUTION
The electrics may be laid and connected only by a specialist and whilst observing the relevant directives.
soldered connection ring initiator
Installation
– +
– 1 +

5.3.1 Pump

For electrical installation works, the appropriate safety
regulations must be followed.
Before connecting the pump, ensure the electricity supply
is switched off.
The supply voltage should be checked against
the specifications on the rating plate on the gas sampling pump. The supply voltage may deviate by a maximum of +/– 10 % from the specifications on the rating plate.
The earth wire should be connected to the gas
sampling pump. Install the gas sampling pump in such a way that it is not possible to touch the live parts (electrical connection).
A device for isolating the gas sampling pump from the
mains supply should be included in the electrical installation. The electricity supply to the pump motor should be protected with a fuse. The current consumption can be found on the rating plate.
For systems with a gas sampling pump, a motor circuit
protector should be provided in the supply voltage cable, without exception. The protection switch is installed in the control cabinet. The motor circuit protector should be set to the nominal motor current for the gas sampling pump (see rating plate). Please note the manufacturer's technical information (Instructions for Use are included in the documentation).
limit value transmitter connection
00823944_en.eps

5.3.5 Connection cable:

The connection cables for the intrinsically safe circuit should be selected according to the relevant installation standard. In so doing, the formation of a summation current between different intrinsically safe circuits of the float-type flow meter should be prevented. When laying the cables, ensure sufficient distance between the surfaces of the measuring component and the connection cable.

5.3.6 Earth connection:

With float-type flow meters, when the flow impacts non­conductive components during operation this can cause charge separation in the measuring tube. In the case of glass equipment, it is, in principle, possible for the electrostatic field generated within the measuring tube to penetrate through to the outside of the equipment.
earthing connection

5.3.2 Gas transmitter

Gas transmitters from Dräger are connected to a central
controller, e.g. Dräger REGARD, in accordance with the specifications in the associated Instructions for Use (see section 7 on page 8).

5.3.3 Flow meter with ring initiator

The flow meter is supplied provided with a connection
housing.
The cable is connected directly to the circuit breaker in
the control cabinet.
Please note the manufacturer's technical information
(see Instructions for Use for the flow meter).

5.3.4 Wiring diagram:

The electrical connection of the installed, intrinsically safe, equipment to the + and – terminals is carried out in accordance with the following illustration and table. A limit sensor is connected to each terminal block. Pay attention to the specified polarity.
01823944_en.eps
The float-type flow meter is connected to the installation plate via the earth connection for the purpose of diverting electrostatic charge. The earthing should be connected to the local earth potential by the individual assembling the system as a whole.
The operator is responsible fo r the uninterrupted earthin g of the process line.
The connection merely ensures electrostatic earthing of the equipment and does not meet the requirements for equipotential bonding. When measuring dust-free gases or liquids, the flow rate may not exceed 20 times the nominal flow rate. Note the max. permissible operating pressure PS printed on the rating plate.
Dräger SAM 3100/3200 7
Maintenance
!

6 Maintenance

Dräger SAM 3100/3200 aspirator system:
The aspirator system is designed so as to minimise the need for servicing.
Directions for maintenance and servicing can be found in
the Instructions for Use for the components used.
Depending on the dust load in the sample gas, the filter
inserts should be replaced when visibly soiled. Spare parts: see the Instructions for Use for the filter.
In the case of systems with gas sampling pump, it is
recommended that the diaphragm and valve plates of the pump are replaced at least once a year.
Spare parts: refer to the Instructions for Use for the gas
sampling pump.
The ejectors for delivering sample gas have no mechanical
parts subject to wear, and are therefore maintenance-free.
Gas transmitter
Maintenance and servicing of the gas transmitter should be
carried out according to the enclosed Instructions for Use.
The calibration interval and calibration i nstructions can be
found in the Instructions for Use for the gas transmitter and for the DrägerSensor.
For aspirator systems with gas sampling pump, the pump
should be switched off during test gas feeding (calibrating). For models with ejector, the air feed should likewise be interrupted.

7 Wiring diagrams

CAUTION
Electrical wiring is only to be laid and connected by an expert, paying attention to the relevant regulations and laws concerning electrical equipment in potentially explosive atmospheres as well as the approval conditions.
Consult the Instructions for Use for installation!
8 Dräger SAM 3100/3200

7.1 Wiring diagram for PEX 3000

02023944_en.eps
+24 Volts 0 Volt
Cable screen
contacted within
the cable gland
PEX 3000
Type XTR 0000,
XTR 0001,
XTR 0010
and XTR 0011
Cable screen
contacted within
the cable gland
PEX 3000
Type XTR 0090,
XTR 0091
Sensing head
Polytron SE Ex PR ... DD
Power supply
24 V 20 %,
0.15 A
4 to 20 mA 0 mA
Controller Unit
max. cable length
50 m 100 m 150 m
core cross-section
0.5 mm
2
1.0 mm
2
1.5 mm
2
12
3
12
3
Wiring diagrams
PEX 3000, all types PEX 3000, types XTR 0090 and XTR 0091
Connection to central controller: Connection to sampling head Connect terminal +24 V to +24 volts Connect terminal br/br to terminal 1 Connect terminal SIG to 4 bis 20 mA input Connect terminal ge/yw to terminal 2 Connect terminal 0 V to 0 volts Connect terminal sw/bk to terminal 3
Dräger SAM 3100/3200 9
Wiring diagrams
02423944_en.eps
Non-explosion-hazard areaExplosion-hazard area, zone 0, 1 or Div. 1
Safety barrier
Control unit
Ex i
PA
Earth point
4 ... 20 mA
0 V
+
+
4 to 20 mA
+24 V
!
!
02323944_en.eps
Non-explosion-hazard area
without a safety barrier
Control unit
4 ... 20 mA
0 V
+
+
4 to 20 mA
+24 V
Explosion-hazard area, zone 2 or non-explosion hazard

7.2 Wiring diagram for Polytron 3000 / Polytron 7000

Installing the transmitter in potentially explosive atmospheres of zone 0 or zone 1
Installing the transmitter in potentially explosive atmospheres of zone 2 or in areas not at risk of explosion.
WARNING
The category 1 classification must be cut out of the rating plate hanger at the location provided. Once the equipment has been operated in accordance with this installation, it may n o longer be installed in mines in which firedamp may occur, nor in potentially explosive atmospheres of zone 0 or zone 1 (equipment category 1 or 2). Risk of explosion!
Installing the transmitter in areas not at risk of explosion:
WARNING
The Ex protection classification must be removed from the transmitter. Once the transmitter has been operated in accordance with this installation, it may no longer be installed in potentially explosive atmospheres.
10 Dräger SAM 3100/3200

7.3 Wiring diagram for PIR 7000 / PIR 7200

2123944_en.eps
+
+
R
S
123456
power supply
red
black
brown
white
green/yellow
central device, e.g. Dräger REGARD
02223944_en.eps
+
+
R
S
123456
power supply
red
black
brown
white
green/yellow
central device
Wiring diagram for operation as a 4 to 20 mA current source (source operation):
Wiring diagram for operation as a 4 to 20 mA current sink (sink operation):
Wiring diagrams
Dräger SAM 3100/3200 11
List of materials

8 List of materials

Name Order no. Manufacturer
Gas transmitter and sensor type According to customer requirements Dräger
Aspirator system SAM 3100 / 3200
Dräger
for a gas transmitter, comprising:
Base plate, 500 mm x 500 mm, stainless steel DrägerFilter, fine filter 1 µm 38.PC1410PVDF-ISW ISWFlow meter with ring initiator,
monostable, flow monitoring
15. DK 800 PV K 1-MO 6–60 l/h
Krohne
10–100 l/h 25–250 l/h
All system hoses are PTFE, screw connections are PVDF, system is installed on the base plate.
Additional equipment:
Gas sampling pump, not for Ex areas PM21772-87 (N87 TTE) ISW (KNF) Gas sampling pump, for Ex areas PM21773 -87 (N87 TTE Ex) ISW (KNF) Protective housing, 500 x 500 x 300 mm,
plastic, filter mounted externally Protective housing, 500 x 500 x 300 mm,
sheet steel, filter mounted externally Protective housing, 500 x 500 x 300 mm,
stainless steel, for Ex areas, filter mounted externally 3/2-way spherical valve, stainless steel 02.SS-42 GXS 6 mm Swagelok Ejector 01.710200.00VA ISW Regulating valve 70.159.625 Festo Isolation amplifier 24 V DC 03.160312 Steel Isolation amplifier 230 V AC 03.160321 Steel Motor circuit protector 0 to 0.4 A 115.072732 Eaton
KS 1453.600 Rittal
AE 1013.600 Rittal
AE 1013.600 Rittal
12 Dräger SAM 3100/3200
Dräger Safety AG & Co. KGaA
Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 20 80 www.draeger.com