Dräger Polytron 7500 Instructions For Use Manual

Page 1
D
Dräger Polytron 7500
Instructions for Use
9023927 - 2nd edition - May 2007
ST-3804-2005_sw.eps
Page 1 of 72 Pages
Page 2

Contents

Contents
For Your Safety
Intended Use
Installing Dräger Polytron 7500
Preparing for installation Installing the Pyrolyzer docking station Electrical connections Installing the Dräger Polytron 7500
Installing accessories
Relay module Polytron 7500 Dräger Polytron 7500 software dongles
Start-up
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Analogue signal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Display Displays of control LEDs Activating info mode
Maintenance
Maintenance intervals Calibrating the unit Setting up the unit Replacing the sensor Replacing the pump Replacing the pyrolysis oven Replacing the internal dust filter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fault – Cause – Remedy
Menu functions
Menu structure
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Basic operating procedures
Switching to quick-menu mode Switching to menu mode Entering the password Navigation in the menu
The menu » Information «
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Sub-menu » Instrument « Sub-menu » Sensor « Sub-menu » Datalogger «
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Page 2 of 72 Pages
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
9023927 - 2nd edition - May 2007
Page 3
Contents
The menu » Calibration «
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Sub-menu » Zero. calibration « Sub-menu » Span. cal. « Autocalibration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
The menu » Settings «
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Sub-menu » Instrument « Sub-menu » Communication « Sub-menu » Sensor « Sub-menu » Datalogger «
Polytron 7500 Operation via LON
Technical Data
Order List
Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Calibration accessories Spare parts
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Drilling templates
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Pyrolyzer Docking Station
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
9023927 - 2nd edition - May 2007
Page 3 of 72 Pages
Page 4

For Your Safety

For Your Safety
Strictly follow the Instructions for Use
Any use of the Polytron 7500 requires full understanding and strict observation of these Instructions for Use. The Polytron 7500 is only to be used for the purpose specified here.
Maintenance
The Polytron 7500 must be inspected and serviced regularly by suitably qualified persons. Repair and general overhaul of the Polytron 7500 may only be carried out by trained service personnel. We recommend that a service contract be obtained with Dräger Safety and that all repairs also be carried out by them. Only authentic Dräger spare parts may be used for maintenance. Observe chapter “Maintenance intervals”.
Do not operate in explosion-hazard areas
The Polytron 7500 is not suitable for use in explosion-hazard areas.
Accessories
Do not use accessory parts other than those listed in the order list
Liability for proper function or damage
The liability for the proper function of the Polytron 7500 is irrevocably transferred to the owner or operator to the extent that the Polytron 7500 was serviced or repaired by personnel not employed or authorised by Dräger Safety or when the Polytron 7500 was used in a manner not conforming to its intended use. Dräger Safety cannot be held responsible for damage caused by non-compliance with the recommendations given above. The warranty and liability provisions of the terms of sale and delivery of Dräger Safety are likewise not modified by the recom­mendations given above.
Dräger Safety AG & Co. KGaA
Page 4 of 72 Pages
9023927 - 2nd edition - May 2007
Page 5

Intended Use

Intended Use
Dräger Polytron
— For stationary, continuous monitoring of gas concentrations in the intake ambient
air, with built-in DrägerSensor
®
7500
®
.
— The Polytron 7500 is available in four types:
Type Order No.
Polytron 7500 DrägerSensor
Dräger Polytron 7500 NF 0 to 50 ppm NF
(CAS 7783-54-2)
3
3
Dräger Polytron 7500 PFC 0 to 30 ppm C 0 to 30 ppm C Dräger Polytron 7500 NF 0 to 50 ppm NF
F
(CAS 559-40-0)
5
8
F
(CAS 685-63-2)
4
6
(CAS 7783-54-2)
3
LON
3
Dräger Polytron 7500 PFC LON 0 to 30 ppm C 0 to 30 ppm C
F
(CAS 559-40-0)
5
8
F
(CAS 685-63-2)
4
6
83 18 827 68 11 125
83 18 828 68 11 120
83 18 829 68 11 125
83 18 830 68 11 120
Note: Polytron 7500 cannot be used with DrägerSensors other than the above listed. The corresponding DrägerSensor must be used to ensure that the unit functions correctly.
ATTENTION! Explosion hazard! Do not operate underground or in explosion-hazard areas! The Polytron 7500 does not meet the standards for flameproofing and explo­sion protection.
00123927_1.eps
Not to be used for intake from explosion-hazard areas! The concentration of flammable substances in the intake air must be limited to values below the LEL
(Lower Explosive Limit)! The gas mixture may otherwise be ignited because of the high pyrolysis tem­perature in the Polytron 7500.
Only suitable for use in buildings!
— The measuring range may be selected, but it is dependent on the sensor installed.
®
— With 4 to 20 mA interface or HART
for connection to a suitable control unit.
— Optional: compatible with LON interface for connection to a suitable control unit.
_______________
® Polytron is a registered trademark of Dräger.
DrägerSensor is a registered trademark of Dräger. HART is a registered trademark of HCF, Austin, Texas, USA
9023927 - 2nd edition - May 2007
Page 5 of 72 Pages
Page 6
Intended Use
If used together with a control unit (such as Regard) or equipped with a relay module: — Warning before any hazardous gas concentrations are reached. — Automatic implementation of counter measures (for example, additional ventila-
tion). — Indication of unit faults; display of maintenance measures required. — Special calibration mode (blocking of alarm triggering, display of calibration
mode, one-man calibration).
Optional extras:
Polytron 7500 relay module
This module permits the local switching of actuators, alarm generators, etc. on the basis of the measured gas concentration.
Dräger Polytron 7500 software dongles
For activation of additional functions of the Dräger Polytron 7500.
Page 6 of 72 Pages
9023927 - 2nd edition - May 2007
Page 7

Installing Dräger Polytron 7500

Preparing for installation

The performance and effectiveness of the entire system depends essentially on the position chosen for installing the transmitter.
The following should be noted during installation: — Local requirements and regulations governing the installation of gas measuring
systems.
— Relevant regulations concerning the connection and routing of electric power
supply and signal lines.
— The full scope of environmental factors to which the Polytron 7500 may be ex-
posed (ambient conditions: see Technical Data, page 63). — The specific uses (e.g. possible leaks). — All other factors and conditions which could have a negative effect on the instal-
lation and operation of the system. — Physical properties of the gas to be measured:
For gases with a density lower than that of air, the gas intake must be located
above any possible leak or at the highest point at which large concentrations of
gas may occur.
For gases and vapours with a density greater than that of air, the gas intake must
be located below a possible leak or at the lowest point at which such gases and
vapours may occur.
The humidity of the gas to be measured must be between 20 and 90 % relative
humidity.
Installing Dräger Polytron 7500
— Accessibility for the necessary maintenance work . see “Installing the Pyrolyzer
docking station” on page 8.
Dräger Polytron 7500 consists of two main components: — Pyrolyzer docking station. — Dräger Polytron 7500.
9023927 - 2nd edition - May 2007
Page 7 of 72 Pages
Page 8
Installing Dräger Polytron 7500

Installing the Pyrolyzer docking station

1
2
3
— Install in an area with low vibrations and stable temperatures. — Do not install in an area where there are draughts of very warm air (>40
During installation, the slots for fitting the Polytron 7500 must point upwards on the upper edge.
A space of at least 5 cm – preferably 10 cm – must be maintained above and to all sides for the installation of the Polytron 7500.
A space of at least 10 cm – preferably 30 cm – must be maintained below the docking station to permit access for maintenance.
Push lock for connecting terminal block upwards, pull out 4-pin connecting termi­nal block from the front and insert it again after completion of the installation work.
Install the docking station using four screws e.g. M6 to a firm wall (drilling tem­plate: see page 69)
Attention: If the wall is not flat, use suitable spacers (such as mounting bracket 68 09 772) to prevent warping of the case
o
C).
10 cm
11
10 cm
10 cm
2
30 cm
00223927_1.eps

Electrical connections

Caution: Do not connect the unit to the mains before the electrical installation is com­plete and has been checked.
Connect the docking station to the central unit with a cable with at least three wires conductor cross-section, 0.5 to 2.5 mm Line lengths: see “Maximum line lengths” on page 9. — For currents of 3 and 22 mA, a DC voltage between 16.5 V DC (3 mA), or 8.0 V
DC (22 mA) must be present at the unit (between the terminals +24 V and 4...20).

3-wire connection – Installing the 4 to 20 mA current loop

Install the 3-wire connection cable in the cable gland, cut to length and strip ends (about 80 mm).
Shorten the shield (if installed) to prevent short-circuiting.
Connecting the cable: secure in terminals of 4-pin connecting terminal block – ensure correct polarity . Slide connecting terminal block back into holder until the lock clicks into place.
2
.
3
+24V
0V
4...20
00323927_1.eps
Page 8 of 72 Pages
9023927 - 2nd edition - May 2007
Page 9
– Connecting to the central unit with a central power supply
Connect shield to GND of central unit (e.g. housing, earth bar, etc.).
Installing Dräger Polytron 7500
+ 4 ... 20 mA
R
M
R
0 V
shunt
+
Central unit

Maximum line lengths

Installing a remote central unit with power supply by 3-wire connection the voltage drop due to the line resistance [R
] has to be taken in consideration.
line
In order to detect a Pyrolyzer failure in the central unit [IF] and the current drawn by the Pyrolyzer in a fault situation (250 mA) combined with the cable cross-section [A] and the shunt resistor [R
R
L
line
max
= (R
= R
x IF) / 250 mA
shunt
x A / (0.0175 Ohm x mm2 / m)
line
] will result in a maximum cable length [L
shunt
max
].
Example: The following is valid with a permitted error current [IF] of 3.15 mA:
@ R
0.50 mm2 18.23 m 0.50 mm2 36.46 m 0.50 mm
0.75 mm
1.50 mm
2.50 mm
In a given situation the cable length [L
= 50 Ohm @ R
shunt
A L
2 2 2
max
27.34 m 0.75 mm54.69 m 1.50 mm2≥109.38 m 1.50 mm2≥273.45 m
91.15 m 2.50 mm2≥182.30 m 2.50 mm2≥455.75 m
= 100 Ohm @ R
shunt
A L
2
max
max
54.69 m 0.75 mm2≥136.70 m
] can be increased by a series connection
shunt
A L
2
= 250 Ohm
max
91.15 m
of a resistor [RM] into the cable for the 4 to 20 mA signal.
00423927_1_en.eps
R
schunt new
= R
shunt old
+ R
M
Following limitations have to be fulfilled: R
line
+ R
= between 30 Ohm and 500 Ohm,
shunt
For currents of 3 and 22 mA, a DC voltage between 16.5 V DC (3 mA), or 8.0 V DC (22 mA) must be present at the unit (between the terminals +24 V and 4...20), see page 8.
9023927 - 2nd edition - May 2007
Page 9 of 72 Pages
Page 10
Installing Dräger Polytron 7500
– Connecting to the central unit with individual power supplies:
Central unit
+
R
1)
IMPORTANT: star-shaped ground system (no ground loops).
RX corresponds to line resistance R
shunt
R
shunt
from page 9.
line
Pyrolyzer 1
– Connecting to a HART Multidrop-capable central
To ensure that the unit operates as intended, the impedance of the 4 to 20 mA signal loop must not exceed 500 Ohm and must be between 230 and 500 Ohm for HART­compatible "smart" loops. The conductors of the power supply must have a suffi­ciently low resistance to ensure that the supply voltage of the unit is correct.
+
1) 1)
Pyrolyzer 2
R
X
4...20
0 V
+24 V
+
0 V
R
X
4...20
+24 V
04623927_1_en.eps
Each unit must first be put into service separately.
Use the menu item "Polling Address" to assign a different polling address in the range "1" to "15" to each Polytron 7500, which is to be connected to the multidrop cable. It is best to assign sequential polling addresses, starting with "1".
Depending on the supply unit, up to 8 Polytron 7500s can be connected to a line.
Multidrop installation with HART communication and individual power supplies: R
= 230 ... 500 Ω
shunt
Multidrop installation with HART communication and a (central) power supply:
R
(pro wire) < U – 15 V Ω / n x 0.8 [Ω]
cable
n = actual number of units in feed unit U = output voltage in V of the feed unit with an output current of n x 0.4 A R
= 230 ... 500 Ω
shunt
Page 10 of 72 Pages
9023927 - 2nd edition - May 2007
Page 11

4-wire connection – Installing the LON communication

Install the 4-wire connection cable in the cable gland, cut to length and strip ends
(about 80 mm).
Shorten the shield (if installed) to prevent short-circuiting.
Connecting the cable:
secure in terminals of 4-pin connecting terminal block – ensure correct polarity. 1 Slide the connecting terminal block back into holder until the lock clicks into
place.
Installing Dräger Polytron 7500
1
+24V
0V LON A LON B
00523927_1.eps
9023927 - 2nd edition - May 2007
Page 11 of 72 Pages
Page 12
Installing Dräger Polytron 7500

Installing the Dräger Polytron 7500

Unpack the Dräger Polytron 7500.
Remove the cover of the Polytron 7500. To do this
1 gently pull apart the cover on both sides and 2 lift upwards.
Fit the Polytron 7500 using the metal hooks into the slots provided on the docking
station.
Attention! The electrical connection via the edge connector must be clean, i.e. the safety hooks (3) underneath must snap into the docking station.
2
11
00623927_1.eps
Slide cover back over the installed Polytron 7500 until it snaps into place at the
sides.
Attention! No cables or internal hoses must be pinched.
Connecting the hoses:
Insert the hose into the quick release fastener below the unit.
4 Gas input from the inlet point right connection (marked with O-ring). 5 Gas output to the offtake left connection.
Check the hoses to make sure they are inserted properly
3
00723927_1.eps
54
00823927_1.eps
Page 12 of 72 Pages
9023927 - 2nd edition - May 2007
Page 13

Installing accessories

Various accessories are available for the Dräger Polytron 7500 and may also be installed later.

Relay module Polytron 7500

Intended Use

— For switching of actuators, alarm generators, etc. on the basis of the measured
gas concentration.

Connecting the devices to be switched

Open the relay housing using the cross screwdriver (4 screws on the rear side).
Install the connection cable in the cable gland, cut to length and strip ends
(approx. 80 mm).
Shorten the shield (if installed) to prevent short-circuiting.
Installing accessories
1
2
Connecting the cable:
3 potential-free relay outputs with 250 V / 5 A (AC) switching capability are available:
1 Fault relay (switches in the case of a device fault) 2 A2 relay (switches when the A2 gas alarm is active) 3 A1 relay (switches when the A1 gas alarm is active)
Connect the devices to be switched to the terminals.

Connection assignment of relay module:

red
black
yellow
Close the relay housing again.
(normally closed)
1
(common)
2 2
(normally open)
3
— Setting the alarm thresholds: see “Alarm / Relay settings” on page 45.
3
00923927_1.eps
1
3
01023927_1_en.eps
9023927 - 2nd edition - May 2007
Page 13 of 72 Pages
Page 14
Installing accessories

Inserting the relay module into the docking station

Remove the cover of the Polytron 7500. To do this
4 gently pull apart the cover on both sides and 5 lift upwards.
6 Insert connector with clip of the relay cable into opening on the back-plate of the
Polytron 7500.
7 Connect the other end onto the terminal in the measuring unit. 8 Fix cable with cable tie to the bracket
5
44
04723927_1.eps
8
7
9 Push relay housing from below into the docking station until it snaps into place.
Insert the Polytron 7500 back into the docking station.

Carry out function test

— Polytron 7500 operates in the measurement mode (normal operation). 10 The LED on the side of the relay module lights green.
Hold the hose briefly until a flow fault is displayed (red LED on the front side of
the Dräger Polytron 7500).
10 The LED on the side of the relay module lights red.
6
04823927_1.eps
9
10
Page 14 of 72 Pages
01123927_1.eps
9023927 - 2nd edition - May 2007
Page 15

Dräger Polytron 7500 software dongles

Intended Use
Dräger Polytron 7500 software dongle – 83 17 618, 83 17 619 or 8317860: — For activating additional functions in the Dräger Polytron 7500:
Data Dongle 83 17 618 Colour code blue
Sensor Dongle 83 17 619 Colour code silver
Sensor Diagnostic Dongle 83 17 860 Colour code green
Installing the software dongles
Remove the cover from the Polytron 7500.
Loosen lock below the Polytron 7500 and remove the unit from the docking sta-
tion.
— The Polytron 7500 must be disconnected from the mains!
— Activates the Event Logger, the Datalogger
and the graphical concentration display.
— Activates the sensor self-test.
— Activates the sensor self-test, the display of
the remaining sensor lifetime and the sensor di­agnostic function.
Installing accessories
1 The Dräger logo on the dongle should be facing to the front. Then insert the don-
gle into any of the three slots. Up to three dongles may be installed simultaneously.
Insert the Polytron 7500 back into the docking station
Place the cover back on.
Note: The correct operation of the software dongle can be checked by switching the measuring unit on and selecting the menu items » Information «, » Instrument «, » Module « from the unit menu, see page 36.
111
01223927_1.eps
9023927 - 2nd edition - May 2007
Page 15 of 72 Pages
Page 16

Start-up

Start-up
Switch on power supply.
— The balls in the flow tube should be floating at half way.
— The Polytron 7500 begins its warm-up routine:
— The software version, the date and the time are displayed.
Note: For the correct operation and functionality it is important to set the date and time.
— The sensor is now warming up. The remaining warming-up time for the
sensor is displayed.
Pioneering Solutions
Polytron 7000
SWversion: 2.4
29.05.05 11:47
Sensor ready
: 01 :
in 00
30
01423927_1_en.eps
01523927_1_de.eps
— The sensor is ready for use.
— Depending on the type of sensor installed, the warming-up period time may last
up to 30 minutes. See the related information in the operating instructions for the DrägerSensor. At extremely high or low temperatures, the warming-up time may last longer.
When the sensor has warmed up:
Calibrate sensor, page 22, when a pre-calibrated sensor is not used.
— The Polytron 7500 is ready for use.
Check the transmission of the signals between to the control unit and the initiation
of alarms, see the function group » Analogue interface « on page 54.
NF
3
0.0
NF
3
ppm
ppm
01623927_1_en.eps
01723927_1_en.eps
Page 16 of 72 Pages
9023927 - 2nd edition - May 2007
Page 17

Analogue signal

— A current between 4 and 20 mA flows through the current loop during normal op-
eration. This current is proportional to the gas concentration.
— The Polytron 7500 uses various current values to indicate the operating status:
Current Meaning
4 mA Zero point
20 mA Full-scale value
<3.2 mA Fault
3.8 mA ... 4 mA Sensor drift below zero point
20 mA ... 20.5 mA Measuring range exceeded
>21 mA Fault in analogue output
3.4 mA Maintenance signal
<3.2 mA1) for 1 second1)
every 10 seconds1)
1)
Factory setting; can be configured as desired, page 52.
Warning signal (factory setting: off)
Start-up

Display

— In measuring mode, the display shows the actual gas concentration, e.g.:
An alarm is triggered:
— when the alarm threshold for the concentration alarm is exceeded,
— if the measured concentration exceeds the full-scale value:
the special symbol »
Y Y Y Y « is then displayed instead of the measured value.
0.9
NF
3
ppm
5.0
NF
3
A1
Y Y Y Y
NF
3
ppm
01823927_1_en.eps
01923927_1_en.eps
02023927_1_en.eps
— If the measured concentration drops below the calibrated zero point:
the special symbol »
9023927 - 2nd edition - May 2007
X X X X « is then displayed instead of the measured value.
X X X X
NF
3
ppm
Page 17 of 72 Pages
02123927_1_en.eps
Page 18
Start-up

Displays of control LEDs

1 LED » « – pyrolysis oven
lights green when there is no error lights red when the pyrolysis oven is defect. Replace the pyrolysis oven, page 26.
2 LED » « – pump measurement branch
lights green when there is no error lights red when the flow rate in the measurement branch is not sufficient. Replace the pump, page 25 . flashes red when an internal flow test is carried out.
3 LED » « – pump – principal branch
lights green when there is no error lights red when the flow rate in the principal branch is not sufficient. Replace the pump, page 25.
123
02223927_1.eps
The following icons may be displayed on the right side of the display in measur­ing mode in order to indicate the operating status of the unit:
A warning exists – see page 36 for information on how to display warnings. The information can be retrieved in info mode, see page 19.
A fault exists – see page 36 for information on how to display faults.
Maintenance signal to the control unit, see page 55
The flow monitoring is activated
There is a Pyrolyzer fault, see page 44
The measured value exceeds the full-scale value of the analogue interface
The measured value is less than the zero point of the analogue interface
The analogue interface is set to a fixed value (e.g. for multidrop) and is not trans­mitting measured values
"Predictive" maintenance: the sensor is ready for use
"Predictive" maintenance: The sensor is ready for use but nearing the end of its operating lifetime
"Predictive" maintenance: The sensor is still ready for use but should be replaced as soon as possible
The Datalogger is active in roll mode. For details of activating and deactivating the Datalogger, see page 59
The Datalogger is active in stack mode. For details of activating and deactivating the Datalogger, see page 61
Page 18 of 72 Pages
9023927 - 2nd edition - May 2007
Page 19

Activating info mode

The info mode is used to display information about general unit settings and the unit status.
Press and hold the » « key (longer than 3 seconds) – information about the
units is displayed on several screens. — Briefly press the » « key to move to the next screen. — Briefly press the » « to move back to the previous screen. — The info mode can be terminated at any time by pressing the » « key. — If no key is pressed for 30 seconds, the unit automatically returns to its
previous state.
M
OK
Start-up
Example of info mode: Screen 1
Instrument information Line 1 – Date and time Line 2 – Software version Line 3 – Unit Part No. Line 4 – Unit Serial No. Line 5 – Unit code
Screen2
Sensor information: Line 1 – Sensor name Line 2 – Sensor Part No. Line 3 – Sensor Serial No. Line 4 – EEPROM type Line 5 – EEPROM version
Screen. 3
Sensor configuration: Line 1 – Gas name Line 2– Measuring range (cannot be change) and unit of measurement Line 3 – Measuring range for the analogue interface. displayed only if the analogue interface card is installed Line 4 – A1 alarm threshold and unit of measurement Line 5 – A2 alarm threshold and unit of measurement
1)
1)
Screen 4
Pump Infos: Line 1 – Pump flow Line 2 – Threshold error Line 3 – Threshold warning Line 4 – Pump run time
07.05.2005 12:34 SW Version: 1 Part No. : 8318827 Serial No. : ARUA0001 DeviceCode
Instrument Info
Sensorname: NF3 Part No. Serial No. : XXXXXXX EEPROM Typ EEPROM Vers.: 1
Sensor Info
Gasname : NF3 Range : 30.0 ppm 4–20 SP Alarm A1 Alarm A2
Sensor Config
Power : XXX % Fault : X.X l/min Warning : X.X l/min Op. time : XXXX h
: 00006317
: 6811125
: 1
: 30.0 ppm : 5.0 ppm : 10.0 ppm
Pump Info
02323927_1.eps
1/4
02423927_1_en.eps
2/4
02523927_1_en.eps
3/4
02623927_en.eps
4/4
02723927_1_en.eps
1)
Displayed only if a relay module is fitted!
9023927 - 2nd edition - May 2007
Page 19 of 72 Pages
Page 20
Start-up
If "xx.xx.xx xx:xx" is displayed instead of the date and time, or if an incorrect date and time are displayed:
(only after the clock has been reset due to a power failure)
Set the date and time, see page 48.
Note: If the date and time are not set correctly, some functions (such as calibra­tion) cannot be executed.
Page 20 of 72 Pages
9023927 - 2nd edition - May 2007
Page 21

Maintenance

Maintenance intervals

Before starting operation:
Check the calibration, see page 22.
Check the transmission of signals to the control unit and the triggering of
alarms, page 54.
At regular intervals to be defined by the person responsible for the gas warning installation:
Check the transmission of signals to the control unit and the triggering of
alarms, page 54.
If a selective filter specific to the sensor is being used:
Replace the selective filter –
see the related Instructions for Use for details of the capacity of the selective filter
being used.
Maintenance
Calibrate the sensor, see page 22.
The interval for regular calibration depends on the sensor being used and on the
operating conditions.
Polytron 7500 calculates, from the selected calibration interval (see page 58)
when the next calibration is due.
Specific calibration data for the sensor, see the Instructions for Use for the Dräger
sensor.
At the latest every twelve months:
Inspection by specialists.
The inspection intervals must be established in each individual case and short-
ened if necessary, depending on technical safety considerations, engineering
conditions and the technical requirements of the equipment.
We recommend that a service contract be obtained with Dräger Safety and that
all repairs also be carried out by them.
In order to check for leaks, measure the flow at the inlet point and behind the
Polytron 7500.
As required:
Replace the sensor, page 23.
Replace the pump, page 25.
Replace the pyrolysis oven, page 26.
Replace the internal dust filter, page 27.
9023927 - 2nd edition - May 2007
Page 21 of 72 Pages
Page 22
Maintenance

Calibrating the unit

— Ensure that the sensor is warmed up before it is calibrated. Warming-up time: see
the Instructions for Use for the DrägerSensor.
— The Polytron 7500 can be calibrated by the operator on site.
For critical applications, the calibration intervals are to be defined in accordance
with the recommendations in EN 500731) or. EN45544-42) and national regula­tions.

Note the calibration sequence!

First check the zero point and calibrate it if necessary, immediately after this,
check the sensitivity and adjust it as necessary.
— Never calibrate the sensitivity before calibrating the zero point.
— Calibration cannot be carried out if the date and time are not set.
Setting the date and time, page 48.
— Calibration menu, page 41 to page 39
— Zero gas and calibration gas: See the related information in the Instructions for
Use for the DrägerSensor.
Caution: Calibration gas must not be inhaled. Risk to health!
Care must be taken about the risks which can arise when using test gas; hazard instructions and safety advice must be observed. For details, see appropriate Safety Sheets.

Setting up the unit

Individual settings can be made:
— via the keypad in menu mode — via the HART interface, — with the Dräger Hand Held Terminal (DHHT)
Note: After setting up the unit automatically with the copy function of the Dräger Hand Held Terminals, the plausibility of the settings must be checked.
1)
EN 50073 – Guidelines for selection, installation, use and maintenance of devices for the detection and measurement of flammable gases and oxygen.
2)
EN 45544-4 – Electrical devices for the direct detection and direct concentration measure­ment of toxic gases and vapours – Part 4: Guidelines for selection, installation, use and maintenance.
Page 22 of 72 Pages
9023927 - 2nd edition - May 2007
Page 23

Replacing the sensor

The sensor can be replaced, if necessary, without interrupting the supply voltage. Use only DrägerSensors, which are approved for use with the Polytron 7500.
Type Order No.
Polytron 7500 DrägerSensor
Dräger Polytron 7500 NF
3
0 to 50 ppm NF3 (CAS 7783-54-2) Dräger Polytron 7500 PFC 0 to 30 ppm C5F8 (CAS 559-40-0) 0 to 30 ppm C4F6 (CAS 685-63-2) Dräger Polytron 7500 NF3 LON 0 to 50 ppm NF3 (CAS 7783-54-2) Dräger Polytron 7500 PFC LON 0 to 30 ppm C
(CAS 559-40-0)
5F8
0 to 30 ppm C4F6 (CAS 685-63-2)
In the menu » Settings « select the sub-menu » Sensor « and then the function
» Change sensor « – page 56.
83 18 827 68 11 125
83 18 828 68 11 120
83 18 829 68 11 125
83 18 830 68 11 120
Maintenance
Remove the cover of the Polytron 7500, by gently pulling apart the cover on both
sides and lifting upwards.
Attention! When the unit is opened, there is the danger of scalding yourself on hot parts of the Polytron 7500.
1 Loosen the sensor adapter from the sensor. 2 Remove the sensor from the socket on the printed circuit board.
Remove the new sensor from the packaging. Check that the sensor type is iden-
tical to the one which is installed in the Polytron 7500.
Remove the protective cap from the sensor on the DrägerSensor XS PFC!
There is a coded connector on the back of the sensor. Insert the sensor such into
the socket on the printed circuit board so that the code of the connector matches
the code of the socket.
Incorrect connection can damage the sensor! 1 Fit sensor adapter onto the sensor.
Refit the cover of the Polytron 7500.
Check the sensor function.
— The configuration of the Polytron 7500 is kept in its entirety, see also “– Sensor
lock” on page 57.
Disposal of electrochemical sensors: — Sensors must be disposed of as special waste.
Caution: — Do not throw sensors into the fire – explosion hazard. — Do not open sensors forcibly – risk of caustic burns.
1
2
02823927_1.eps
Note the relevant waste disposal regulations.
Further information can be obtained from the relevant local authority and from ap-
propriate waste disposal companies.
9023927 - 2nd edition - May 2007
Page 23 of 72 Pages
Page 24
Maintenance

Sensor diagnostic function

This function is active only if the Polytron 7500 is equipped with a sensor diagnostic dongle (Order No. 83 17 860). — Extended sensor self-test function, taking such things as the temperature, gas
monitoring and remaining sensitivity into account.
— During normal operation, the sensor status is indicated by the sensor-diagnostic
icon in the display:
The sensor is ready
The sensor is ready for use but nearing the end of its operating lifetime The sensor is still ready for use but should be replaced as soon as possible
Page 24 of 72 Pages
9023927 - 2nd edition - May 2007
Page 25

Replacing the pump

Disable the supply voltage.
Remove the cover of the Polytron 7500. To do this
1 gently pull apart the cover on both sides and 2 lift upwards.
Attention! When the unit is opened, there is the danger of scalding yourself on hot parts of the Polytron 7500.

Replace the pump for the measurement branch

— Pump on the right side infront of the pyrolysis oven.
Maintenance
2
11
02923927_1.eps
Remove the connector of the pump.
Remove the upper holder of the pump from the middle sheet.
Remove the hose from the pump and insert it into the new pump at the same
position.
Refit the new pump (without blue label) sideways on the lower holder.
Insert the upper holder of the pump into the middle sheet and pull it through.
Insert the connector of the new pump into the socket on the printed circuit board.
Ensure correct polarity! Blue cable to the outside.

Replace the pump for the principal branch

— Pump on the left side infront of the rear wall.
Remove the connector of the pump.
Remove the upper holder of the pump from the middle sheet.
Remove the hose from the pump and insert it into the new pump at the same
position.
Refit the new pump (with blue label) sideways on the lower holder.
Insert the upper holder of the pump into the middle sheet and pull it through.
Insert the connector of the new pump into the socket on the printed circuit board.
Ensure correct polarity! Blue cable to the outside.
sans bleu étiquette
blue
03023927_02_fr.eps
avec bleu étiquette
bleu
03123927_02_fr.eps
Refit the cover of the Polytron 7500.
Switch on power supply.
Wait until the sensor has fully warmed up.
— The Polytron 7500 is ready for use again.
9023927 - 2nd edition - May 2007
Page 25 of 72 Pages
Page 26
Maintenance

Replacing the pyrolysis oven

Disable the supply voltage.
Remove the cover of the Polytron 7500. To do this
1 gently pull apart the cover on both sides and 2 lift upwards.
Attention! When the unit is opened, there is the danger of scalding yourself on hot parts of the Polytron 7500.
Only use a pyrolysis oven, which is suitable for use with the Polytron 7500 with the defined gas type, see “Order List” on page 64.
2
11
03223927_1.eps
Disconnect the three electrical connections of the pyrolysis oven on the printed
circuit board.
Loosen the two screws for fixing on the rear side – do not unscrew completely.
Remove the pyrolysis oven upwards from the holder.
Remove the hoses to the pyrolysis oven and connect to the new pyrolysis oven at
the same position.
Insert the new pyrolysis oven from above into the holder and tighten the two
screws.
Reconnect the three electrical connections of the pyrolysis oven.
Refit the cover of the Polytron 7500.
Switch on power supply.
Wait until the sensor has fully warmed up.
— The Polytron 7500 is ready for use again.
03323927_1.eps
Page 26 of 72 Pages
9023927 - 2nd edition - May 2007
Page 27
Replacing the internal dust filter
— The internal dust filter can be replaced without interrupting the supply voltage.
Attention! The measurement result that is displayed during the replacement is not correct.
Remove the cover of the Polytron 7500. To do this
1 gently pull apart the cover on both sides and 2 lift upwards.
Attention! When the unit is opened, there is the danger of scalding yourself on hot parts of the Polytron 7500.
Maintenance
2
Disconnect hose connections from the dust filter and connect to the new dust fil-
ter at the same position.
Refit the cover of the Polytron 7500.
— The Polytron 7500 is ready for use again.
11
03423927_1.eps
03523927_1.eps
9023927 - 2nd edition - May 2007
Page 27 of 72 Pages
Page 28
Fault – Cause – Remedy
Fault – Cause – Remedy
The fault and warning numbers shown in the following tables are displayed in the menu under » Information «, » Instrument «, » Fault « or » Warnings « – see page 36.
Fault number Cause Remedy # 1 Serious data error in unit –
various causes.
# 2 Serious unit fault –
various causes.
# 61 Data error on the interface card –
various causes
# 63 Hardware or software fault in the pyrolysis
module.
# 64 Gas flow of the pump falls below the warn-
ing threshold. Reliable measurements are no longer pos­sible.
# 65 Open-circuit in 3-wire cable. Check the connections. # 67 Bad contact of the relay module. Check the connection of the relay module. # 100 Unit cannot detect a sensor. Remove the sensor and install it again, page 23.
Initialise the unit with the menu items » Settings «, » Instrument «, » Init. device «, page 49. If this error occurs again: Have the Polytron 7500 checked by suitably qualified per­sons e.g. service personnel from Dräger Safety.
Have the Polytron 7500 checked by suitably qualified per­sons e.g. service personnel from Dräger Safety.
Have the Polytron 7500 checked by suitably qualified per­sons e.g. service personnel from Dräger Safety.
Have the Polytron 7500 checked by suitably qualified per­sons e.g. service personnel from Dräger Safety.
Check the hoses for blockages, If necessary adjust pump flow.
Check the sensor plug or install a new sensor.
# 101 Sensor data error in the unit. Remove the sensor and install it again, page 23.
If this error occurs again: Have the Polytron 7500 checked by suitably qualified persons e.g. service personnel from Dräger Safety.
# 102 Unit does not support this
sensor version.
# 103 Sensor data error in the unit. Initialise the sensor with the menu items » Settings «,
# 106 Zero point not correctly. Zero point calibration, page 39. # 107 Sensitivity calibration not executed cor-
rectly.
# 108 Sensor data error. Replace the sensor, page 23. # 109 Unit fault. Check the sensor contacts. If this does not help, have the
# 121 Fresh-air calibration (first step of autocali-
bration) not executed correctly.
# 125 Sensor not ready. Replace the sensor, page 23.
Use a compatible sensor, see page 23.
» Sensor «, » Sensor-EC «, » Init. sensor «, page 58. If this error occurs again: Have the Polytron 7500 checked by suitably qualified persons e.g. service personnel from Dräger Safety.
Repeat sensitivity calibration, page 40.
Polytron 7500 checked by suitably qualified persons e.g. service personnel from Dräger Safety.
Repeat autocalibration, page 41. making sure that the ambi­ent air is free of other gases.
Page 28 of 72 Pages
9023927 - 2nd edition - May 2007
Page 29
Fault – Cause – Remedy
Fault number Cause Remedy # 129 Electrolyte liquid evaporates If the problem persists, fit a new sensor, page 23.
The function » Sensor lock « is active or a sensor with a different Part No. has been inserted.
# 134 Bad contact between the sensor and
the sensor card.
Deactivate the function » Sensor lock «, page 57 or use a sensor with the same Part No. as the one which was removed.
Check the sensor contacts. Remove and re-install the sensor several times. If the problem persists, fit a new sensor, page 23.
# 136 Sensor hardware fault. Remove the sensor and install it again. If the problem per-
sists, fit a new sensor, page 23.
Warning number Cause Remedy # 1 Data error in the unit. Certain functions
such as the Datalogger or the dongle func­tions may not be available.
Initialise the unit with the menu items » Settings «, » Instrument «, » Init. device «, page 49. If this error occurs again: Have the Polytron 7500 checked by suitably qualified persons e.g. service personnel from Dräger Safety.
# 51 Datalogger is in stack mode and is 100 %
Read out the data. Then clear and restart the Datalogger
full. No more data can be recorded.
# 52 Datalogger is in stack mode and is 90 %
full.
Read out the data as soon as possible. Then clear and restart the Datalogger.
# 53 No valid date and/or time is set. Set the date and time, page 48. # 58 Software dongle was removed without log-
ging off.
Deactivate the function in the menu » Settings «, » Instrument «, » SW dongle «, » XXX dongle «, page 50.
Hardware fault in the software dongle. Change the software dongle, page 15.
# 59 Pump worn. Replace the pump, page 25. # 64 Pump gas flow falls below the warning
threshold. Reliable measurements are no
Check the hoses for blockages, If necessary adjust pump flow.
longer possible.
# 106 Increased zero point offset. Zero point calibration, page 39. # 111 Sensor is not working in the specified tem-
perature range.
Operate sensor in the specified temperature range (see Instructions for Use for the DrägerSensor).
# 112 Sensor near end of life. Replace the sensor, page 23. # 114 Calibration interval expired. Recalibrate the unit, page 22. # 115 Sensor was operated for too long with a
Reduce overgassing.
high concentration.
# 119 Sensor is not yet fully warmed up. An
Wait until the sensor has fully warmed up. increased measuring error must be expected.
9023927 - 2nd edition - May 2007
Page 29 of 72 Pages
Page 30
Fault – Cause – Remedy
Warning number Cause Remedy # 120 The sensor has been exposed to an exces-
sively high gas concentration for a long
Reduce the exposure to high gas concentrations. If the problem persists, fit a new sensor, page 23.
period.
# 131 Bad sensor, no longer operating. Replace the sensor, page 23. # 132 Electrolyte liquid evaporates. Measure-
If the problem persists, fit a new sensor, page 23.
ments are no longer possible.
# 135 Information such as the Part No. and the
Serial No. is not available.
Disconnect the unit from the mains and restart it. If this error occurs again: Have the Polytron 7500 checked by DrägerService.
Fault Cause Remedy
LED » « lights
The pyrolysis oven is defect Replace the pyrolysis oven, page 26.
red LED » « lights
red LED » « flashes
red LED » « lights
red All three LEDs
Fault in measurement branch – pump measurement branch defect
An internal flow test is being carried out –
Check the hose connections for blockages. Replace the pump, page 25.
– – –
this is not a fault Fault in principal branch –
pump principal branch defect
Check the hose connections for blockages. Replace the pump, page 25.
Electronic defect Polytron 7500 to be repaired by Service of Dräger Safety. » «, » « and » « lights or flashes red
Page 30 of 72 Pages
9023927 - 2nd edition - May 2007
Page 31

Menu functions

The menu can be operated as desired: — from the keypad with an integrated display on the Polytron 7500, — from a HART-compatible Hand Held Terminal (HHT), — from a HART-compatible control unit or — a Polytron 7500 Palm Pilot 515 (non-Ex version) or Palm Pilot 515x ex-version.
Menu functions
The menus are operated with the three keys – » «, » « and » «. The menus
M
OK
appear on the display.
Key » « — Use this key to move upwards through the menus.
M
Key » « — Use this key to move downwards through the menus. — If the key is held down for more than 3 seconds, the main menu is opened. — If the key is held down for longer than 1 second and less then 3 seconds, the
quick menu is opened (the Info menu is displayed without prompting for a pass­word).
OK
Key » « — This key is used to confirm inputs and selected menus and functions

Menu structure

Overview: page 32.
The unit has two operating modes: measuring mode and menu mode. Menu mode contains the menus » Information «, » Calibration « and » Settings «.

Menu » Information «

The menu » Information « can be opened by any user, but the user is unable to make any changes with this menu option.

Menu » Calibration «

This menu permits routine operations needed for the regular maintenance of the Pol­ytron 7500. It should be accessible to persons who are responsible for such maintenance. If the maintenance password is entered, only this menu is accessible.

Menu » Settings «

This menu permits the setting of individual unit and sensor parameters. It should be accessible to authorised persons from the measuring and regulation department or the work safety department. If the password for this menu is entered, the menu » Calibration « is also accessible.
The passwords for the menus » Calibration « and » Settings « can be changed at any time, page 47.
9023927 - 2nd edition - May 2007
Page 31 of 72 Pages
Page 32
Menu functions
Default password settings when the unit leaves the factory:
Password for the menu » Calibration «: _ _ _ 1 Password for the menu » Settings «: _ _ _ 2

Overview of the menu structure

Back to measure
k
Information
Calibration
Settings
page 35
page 39
page 43
Information
Instrument
Sensor
Datalogger
Calibration
Zero. calibration
Span calibration
Autocalibration
Settings
page 36
page 37
page 38
page 39
page 40
page 41
Information about the sub-menus and functions:
See the specified page.
Page 32 of 72 Pages
Instrument
Communication
Sensor
Datalogger
page 44
page 51
page 56
page 59
9023927 - 2nd edition - May 2007
Page 33

Basic operating procedures

Switching to quick-menu mode

Basic operating procedures
Press the » « for longer than 1 second but less than
M
3 seconds to open the quick menu. Here is the information on the status and settings of the transmitter, see page 35.

Switching to menu mode

Press the » « for longer than 3 seconds.
You will then be prompted for the password.
M

Entering the password

In measuring mode:
Press the » « for longer than 3 seconds.
You will then be prompted for the password.
Use the » « key to move to the line
» Enter password « and press the » « key. The password entry screen appears.
Use the » « and » « keys to set each of the four
positions of the password and press the » « key to confirm each position.
— After you have confirmed the last position, the menu
corresponding to the entered password is opened. If the entered password is invalid, a suitable error mes­sage is displayed.
M
M
OK
OK
M
back to measure
Instrument Sensor Datalogger
1/3
back to measure
Enter password
2/3
Password
_ _ _ _
2/3
Password
0 _ _ _
3/3
back to measure Wrong pwdlevel
9 9 9 9
Enter password
03623927_1_en.eps
03723927_1_en.eps
03823927_1_en.eps
03923927_1_en.eps
04023927_1_en.eps
9023927 - 2nd edition - May 2007
Page 33 of 72 Pages
Page 34
Basic operating procedures

Navigation in the menu

Graphical symbols (icons) simplify the navigation through the various menus:
Together with the text » Back «, » Menu «, etc. » — Exit from the menu or return to previous menu.
Closed folder — This item contains further functions or sub-menus.
Open folder — The functions and sub-menus shown here are contained in this item.
Function — If activated, functions can be executed in a single step or several steps.
Selection activated — For functions which can be selected and activated, activation can be
OK
M
2/2
3/3
done by pressing the » « key.
Top of list displayed — There are no further functions, menus or sub-menus above those current-
ly displayed.
List can be scrolled up — There are further functions, menus or sub-menus above those currently
displayed.
End of list displayed — There are no further functions, menus or sub-menus below those current-
ly displayed.
List can be scrolled down — There are further functions, menus or sub-menus below those currently
displayed.
Next — Execute the related action.
Number of current screen / total number of screens within the function. Input
— Data input with the » « and » « keys.
Page 34 of 72 Pages
9023927 - 2nd edition - May 2007
Page 35

The menu » Information «

The menu » Information « contains all information about the unit status, the sensors and the Datalogger.

Overview

The menu » Information «
Information Information
Calibration Instrument
Settings Sensor
Datalogger
page 36
page 37
page 38
Instrument
Warnings
Faults
Fault codes
Modules
Sensor
Vitality
Last cal. date
Next cal. date
Sensor temperature
Datalogger
Datalogr. status
Show graph
page 36
page 36
page 36
page 36
page 37
page 37
page 37
page 37
page 38
page 38
9023927 - 2nd edition - May 2007
Page 35 of 72 Pages
Page 36
The menu » Information «

Sub-menu » Instrument «

The sub-menu » Instrument Info « contains all functions for interrogating the unit sta­tus.

Warnings

— This function displays any existing warnings in clear text with the warning number,
see page 29. The icon » « is displayed if any warnings are active.
Select the menu items » Information «, » Instrument « and » Warnings « in this
order, pressing the » « key after each selection.
— Any existing warnings are displayed in clear text.
If more than one warning exists, the number of the currently displayed warning and the total number of warnings are displayed in the top right corner (example: 1/3 = screen 1 of 3).
OK

Faults

— This function displays any existing faults in clear text with the error number, see
page 28. If a fault exists, the icon » « is displayed.
Select the menu items » Information «, » Instrument « and » Faults « in this order,
pressing the » « key after each selection.
OK
— Any existing faults are displayed in clear text.
If more than one fault exists, the number of the currently displayed fault and the total number of faults are displayed in the top right corner (example: 1/2 = screen 1 of 2).

Fault codes

— This function displays any existing faults / warning codes in the form of a table.
If a fault exists, the icon » « is displayed.
Select the menu items » Information «, » Instrument « and » Fault codes « in this or-
der, pressing the » « key after each selection.
OK
— Any existing faults are displayed in the form of numerical codes in a table. If all nu-
merical groups are displayed with the value » 00 «, no faults exist.

Modules

— All installed hardware modules are displayed.
Select the menu items » Information «, » Instrument « and » Modules « in this
order, pressing the » « key after each selection.
OK
— A list of all possible modules is displayed. The installed modules are indicated by
a » «. Modules which are not installed are marked with a » «.
Use the » « and » « keys to select individual modules and press the » «
M
OK
key to display more detailed information.
Page 36 of 72 Pages
9023927 - 2nd edition - May 2007
Page 37

Sub-menu » Sensor «

The sub-menu » Sensor « contains the functions for interrogating the sensor status.

Sensor vitality

This function is active only if the Polytron 7500 is equipped with the sensor diagnos­tic dongle, see page 15. — This function displays the remaining sensitivity of the sensor.
Select the menu items » Information «, » Sensor « and » Vitality « in this order,
pressing the » « key after each selection.
— The current Sensor Vitality is displayed. — Dräger Safety recommends that the sensor is exchange when the Sensor Vitality
value is less than 25.
OK
The menu » Information «

Last calibration date

— This function displays the date of the last calibration.
Select the menu items » Information «, » Sensor « and » Last cal. date « in this or-
der, pressing the » « key after each selection.
OK
— The date of the last calibration is displayed.

Next calibration date

— This function displays the date on which calibration is next due.
Select the menu items » Information «, » Sensor « and » Next cal. date « in this or-
der, pressing the » « key after each selection.
OK
— The date on which the sensor is next due for calibration is displayed.

Sensor temperature

— This function displays the current sensor temperature and the maximum sensor
temperature which has been recorded.
Select the menu items » Information «, » Sensor « and » Show sensor temp. « in
this order, pressing the » « key after each selection.
OK
— The current sensor temperature and the maximum sensor temperature which has
been recorded are displayed.
9023927 - 2nd edition - May 2007
Page 37 of 72 Pages
Page 38
The menu » Information «

Sub-menu » Datalogger «

The sub-menu » Datalogger « contains the functions for interrogating the Datalog­ger.

Datalogger status

This function is active only if the Polytron 7500 is equipped with the data dongle 83 17 618, see page 15. — This function displays the status of the Datalogger and the Eventlogger.
Select the menu items » Information «, » Datalogger « and » Datalgr. status «
in this order, pressing the » « key after each selection.
— The current status of the Datalogger and the Eventlogger is displayed:
Datalogr. : on or off (the Datalogger is on or off) Evntlogr. : on or off (the Eventlogger is on or off)
OK
— Activating / deactivating the Datalogger: see page 59. — Activating / deactivating the Eventlogger: see page 59.

Show graph

This function is active only if the Polytron 7500 is equipped with the data dongle 83 17 618, see page 15. — The measured values of the sensor are displayed graphically on a time axis of
15 minutes.
Select the menu items » Information «, » Datalogger « and » Show graph « in this
order, pressing the » « key after each selection.
OK
Page 38 of 72 Pages
9023927 - 2nd edition - May 2007
Page 39

The menu » Calibration «

The menu » Calibration « contains all functions needed for the calibration and adjust­ment of the installed sensor.

Overview

Information
Calibration Calibration
The menu » Calibration «
Settings Zero. calibration
Span calibration
Autocalibration
page 39
page 40
page 41
Zero calibration
XS–PFC
Span calibration
XS–PFC
1)
The sensor shown in this overview serves only as an example and may differ from the actual sensor installed in the unit.

Sub-menu » Zero. calibration «

The sub-menu » Zero calibration « contains the functions for calibrating / adjusting the zero point of the installed sensor.

Zero point calibration / adjustment

The zero point can be calibrated without the use of zero gas when the ambient air is free from measuring gas and other interfering gases. Alternatively:
Provide zero gas with a flow rate of 1.5 L/min via a T-piece to the inlet connection.
Connect a hose with a length of 0.5 m and a diameter which is larger than the hose for the Polytron 7500 to the third connection of the T-piece.
Attention! Never release zero gas directly (without T-piece) from a com­pressed air cylinder!
page 39
1)
1)
page 39
page 40
page 40
Calibration procedure (using the DrägerSensor XS NF3 as an example):
Select the menu items » Calibration «, » Zero calibration « and » XS–NF
order, pressing the » « key after each selection.
OK
« in this
3
— The message » Supply zero gas with flow rate 500 ml/min « is displayed (this flow
rate is not to be observed for the Polytron 7500).
Supply zero gas to the sensor.
Select » Next « and press the » « key.
OK
— The current value and the expired time are now displayed.
9023927 - 2nd edition - May 2007
1.5 L/min
04123927_1_en.eps
Page 39 of 72 Pages
Page 40
The menu » Calibration «
When the displayed value has stabilised:
Select » Calibrate « and press the » « key.
OK
— The message » Zero calibration running « is displayed
— The required value and the actual value are now displayed.
If these are correct as displayed:
Select » Back to menu « and press the » « key.
Disconnect the flow of zero gas.
OK
Zero point calibration can be aborted at any time:
Use the » « key to move to » Back « and press the » « key.
OK

Sub-menu » Span. cal. «

The sub-menu » Span calibration « contains all functions for calibrating the sensitiv­ity of the installed sensor.

Sensitivity calibration

Caution: Test gas must not be inhaled. Risk to health! Care must be taken about the risks which can arise when using test gas; haz­ard instructions and safe safety advice must be observed. For details, see appropriate Safety Sheets.
— The recommended calibration gas concentration for optimum accuracy is be-
tween 40 % and 100 % of the measuring range end value.
1 Remove the inlet line on the Polytron 7500. 2 Fill gas bag (Order No. 68 07 068) with the calibration gas and connect to the in-
let connection of the Polytron 7500.
Calibration procedure (using the DrägerSensor XS NF
Select the menu items » Calibration «, » Span. cal. « and » XS–NF
pressing the » « key after each selection.
OK
as an example):
3
« in this order,
3
— The values for the calibration gas are displayed, for example:
Cal. gas : NF
3
Unit : ppm Concentr. : 000025
— The calibration gas, concentration and unit can be changed:
Select » Cal. gas « and press the » « key. Select the desired calibration gas
from the list and press the » « key again.
Select » Concentr. « and press the » « key. Set the calibration gas concentra-
OK
OK
OK
tion (same procedure as for input of a password).
1
2
10 L
04223927_1.eps
Select » Unit « and press the » « key: Select the desired unit from the list and
OK
Page 40 of 72 Pages
9023927 - 2nd edition - May 2007
Page 41
The menu » Calibration «
press the » « key again.
OK
If the settings agree with the available calibration gas:
Select » Next « and press the » « key.
OK
— The message » Supply gas: NF3 with flow rate 500 ml/min « is displayed (this flow
rate is not to be observed for the Polytron 7500).
— Supply calibration gas to the Polytron 7500.
Select » Next « and press the » « key.
OK
— The current value and the expired time are now displayed.
When the displayed value has stabilised:
Select » Calibrate « and press the » « key.
OK
— In the display the maximum value and the current value as well as the remainder
of the sensor vitality are represented as a bar indication.
If these are correct as displayed:
Select » Next « and press the » « key.
Disconnect the flow of calibration gas.
OK
Attention: There is a danger after the gas is removed that an alarm is given on the central controller while the gas is returning to normal level!
— The calibration interval and the date of the next calibration are displayed.
Select » Back to menu « and press the » « key.
OK
Sensitivity calibration can be aborted at any time:
Use the » « key to move to » Back « and press the » « key.
OK

Autocalibration

Autocalibration consists of fresh-air calibration followed by sensitivity calibration. This function is intended only for users who are familiar with the unit, since the sequence of actions may result in calibration errors. The function can be activated or deactivated with sequence » Settings «, » Sensor «, » Autocal. «.
Autocalibration procedure (using the DrägerSensor XS NF
Select the menu items "Calibration" and "Autocal." in this order, pressing the
OK
» « key after each selection.
Attention: The sensor must be supplied with fresh air, otherwise calibration errors may occur!
as an example):
3
9023927 - 2nd edition - May 2007
Page 41 of 72 Pages
Page 42
The menu » Calibration «
— The message » Fresh-air calibration running « is displayed.
Expose the sensor to the ambient air (for some sensors, a zero gas such as N
2
must be used – see the information in the section “Zero point calibration / adjust­ment” on page 39). Afterwards:
— The values for the calibration gas are displayed, for example,:
Cal. gas : NF
3
Unit : ppm Concentr. : 000025
The current value and the calibration gas concentration are now displayed.
The calibration operation depends on whether the selected calibration gas supports so-called autostability.
Autostability is supported:
When the displayed value has stabilised:
Select » Calibrate « and press the » « key.
OK
Autostability is not supported:
The instrument evaluates the stability of the signal and automatically executes the calibration procedure.
— The required value and the actual value are now displayed.
Disconnect the flow of calibration gas.
Attention: There is a danger after the gas is removed that an alarm is given on the central controller while the gas is returning to normal level!
If these are correct as displayed:
Select » Accept value « and press the » « key.
OK
Page 42 of 72 Pages
9023927 - 2nd edition - May 2007
Page 43

The menu » Settings «

The menu » Settings « contains all functions needed for individual configuration of the unit.

Overview

The menu » Settings «
Information
Calibration
Settings Settings
Instrument
Communication
Sensor
Datalogger
page 44
page 51
page 56
page 59
Instrument
Pump
1)
Alarm
Passwords
Date and Time
Time format
Language
Function key
Device init.
SW Dongle
Communication
Hart interface
2)
Analogue interface
LON interface
3)
page 44
page 45
page 47
page 48
page 48
page 48
page 49
page 49
page 50
page 51
3) page 52
page 55
Sensor
Change sensor
Set autocal.
Sensor test
Sensor lock
XS–NF3
Datalogger
Datalogr. on/off
Set Datalogger
Clear Datalogger
Clear Eventlogr.
1)
This menu function can be executed only if the Polytron 7500 is equipped with a relay module, see page 13.
2)
This menu function can be executed only if the Polytron 7500 is equipped with the appropriate interface card.
3)
The sensor shown in this overview serves only as an example and may differ from the actual sensor installed in the unit.
4)
This menu function can be executed only if the Polytron 7500 is equipped with the data dongle 83 17 618, see page 15.
9023927 - 2nd edition - May 2007
page 56
page 56
page 57
page 57
3)
4)
5)
5)
page 58
page 59
page 59
5) page 61
page 61
Page 43 of 72 Pages
Page 44
The menu » Settings «

Sub-menu » Instrument «

The sub-menu » Instrument « can be used to make various instrument settings.

Pump

This function group contains the setting functions for the pump in the measurement branch.
– Flow fault on/off
— This flow fault setting is not possible for the Polytron 7500.
– Pump output
— This function is used to set the pump output.
Select the menu items » Settings «, » Instrument «, » Pump « and » Pump output «
in this order, pressing the » « key after each selection.
OK
— The message: » Flow alarm will be switched off; please use a flowmeter « is dis-
played.
Connect a flowmeter.
Select » Next « and press the » « key.
Use the » « and » « keys to set the pump output, monitoring the change on
M
OK
the flowmeter.
Select » Next « and press the » « key.
OK
— The flow thresholds are displayed –
Flow threshold for fault: e.g. 0.3 L/min Flow threshold for warning: 0.4 L/min (example)
The flow thresholds cannot be changed for the Polytron 7500. If this setting is attempted, on the value 0.3 L/min is accepted.
– Operating time
— This function is used to display the operating time of the pump.
Select the menu items » Settings «, » Instrument «, » Pump « and
» Operating time « in this order, pressing the » « key after each selection.
OK
— The actual operating time of the pump is displayed in hours.
L/min
04323927_1.eps
Page 44 of 72 Pages
9023927 - 2nd edition - May 2007
Page 45

Alarm / Relay settings

Alarms can be output via a relay and a digital interface if a relay module is installed. This group contains the setting functions for the alarms.
– Alarm on/off
— This function is used to enable and disable alarm monitoring.
Select the menu items » Settings «, » Instrument «, » Alarm « and » Alarm on/off «
in this order, pressing the » « key after each selection.
OK
The menu » Settings «
Select » Enable « or » Disable « and press the » « key to activate it.
OK
Attention: If the alarm is disabled, no alarms will be signalled via the relay or the HART interface!
– Set alarm A1
— This function is used to change the alarm configuration for alarm A1.
Select the menu items » Settings «, » Instrument «, » Alarm « and « Alarm A1 « in
this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the threshold value for
the alarm A1 and press the » « key to confirm the setting.
Press the » « key to confirm the complete alarm threshold value. The setting
OK
OK
M
OK
for the alarm threshold A1 is displayed.
— The function for setting the alarm direction is opened.
Select » Rising « or » Falling « and press the » « key to activate your selection.
Select » Next « and press the » « key.
OK
OK
— The function for setting the self-hold function of the A1 alarm is opened.
Select » Latching « or » Non latching « and press the » « key to activate it.
Select » Next « and press the » « key.
OK
OK
— The function for setting the A1 acknowledgement is opened.
Select » Can be acknowledged « or » Cannot be acknowledged « and press the
OK
» « key to activate it.
— The function for setting the A1 hysteresis is opened.
This function allows the user to set a bandwidth in which a tripped relay stays in its status until the gas concentration is outside this bandwidth. With this function relays will not "chatter" at the alarm set point. E.g. A1 set point is 40 ppm, hyster­esis is set to 3 ppm. alarm A1 will come on at 40 ppm and will stay active until the concentration falls below 37 ppm.
Select the line for input of the hysteresis and press the » « key to switch to
OK
edit mode.
9023927 - 2nd edition - May 2007
Page 45 of 72 Pages
Page 46
The menu » Settings «
Use the » « and » « keys to set each digit of the value and press the » «
M
OK
key to confirm the setting.
Select » Next « and press the » « key.
OK
— The settings of the A1 are indicated.
To confirm select » Confirm « and press the » « key.
OK
— The settings for alarm A1 are now complete.
– Set alarm A2
— This function is used to change the alarm configuration for alarm A2.
Select the menu items "Settings «, "Instrument «, "Alarm « and "Alarm A2 « in this
order, pressing the » « key after each selection
OK
— The settings are made in the same manner as for alarm A1.
– Set ack.
— This function is used to enable or disable the acknowledgement of the alarms with
OK
the » « key.
Select the menu items » Settings «, » Instrument «, » Alarm « and » Set ack. « in
this order, pressing the » « key after each selection.
OK
Select » Enable « or » Disable « and press the » « key to activate it.
OK
– Test alarm A1
— This function simulates the A1 alarm state for testing purposes.
Select the menu items » Settings «, » Instrument «, » Alarm « and » Test alarm A1 «
in this order, pressing the » « key after each selection.
OK
— The function » Test A1 status « is opened.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
— When the function is enabled, the relay and the interfaces are set to the
A1 alarm state.
Page 46 of 72 Pages
9023927 - 2nd edition - May 2007
Page 47
– Test alarm A2
— This function simulates the A2 alarm state for testing purposes.
Select the menu items » Settings «, » Instrument «, » Alarm « and » Test alarm A2 «
in this order, pressing the » « key after each selection.
OK
— The function » Test A2 status « is opened.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
— When the function is enabled, the relay and the interfaces are set to the
A2 alarm state.
– Test fault
— This function simulates the fault alarm state for testing purposes.
Select the menu items » Settings «, » Instrument «, » Alarm « and » Test fault
alarm « in this order, pressing the » « key after each selection.
OK
— The function » Test fault status « is opened.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
The menu » Settings «
— When the function is enabled, the relay and the interfaces are set to the fault
alarm state.

Passwords

This group contains the setting functions for the passwords.
– Password Calibration
— This function is used to change the password for the menu » Calibration «.
Select the menu items » Settings «, » Instrument «, » Passwords « and
» Password Cal. « in this order, pressing the » « key after each selection.
Select the line for password input and press the » « key to switch to edit mode.
Use the » « and » « keys to set each position of the password and press
OK
the » « key to confirm the setting.
Press the » « key to confirm the complete password.
OK
M
OK
OK
– Password Settings
— This function is used to change the password for the menu » Settings «.
Select the menu items » Settings «, » Instrument «, » Passwords « and
» Password Cfg. « in this order, pressing the » « key after each selection.
Select the line for password input and press the » « key to switch to edit mode.
Use the » « and » « keys to set each position of the password and press
OK
the » « key to confirm the setting.
Press the » « key to confirm the complete password.
OK
M
OK
OK
9023927 - 2nd edition - May 2007
Page 47 of 72 Pages
Page 48
The menu » Settings «

Date and time

— This function is used to set the date and / or time.
Select the menu items « Settings «, « Instrument « and « Date and time « in this or-
der, pressing the » « key after each selection.
OK
Select the desired input line (Date or Time) and press the » « key to switch to
OK
edit mode.
Use the » « and » « keys to set the value and press the » « key to confirm
M
OK
the setting.

Time format

— This function is used to set the display format for the date and/or time.
Select the menu items « Settings «, « Instrument « and « Time format « in this or-
der, pressing the » « key after each selection.
Select the desired input line (Date format or Time format) and press the » « key
OK
OK
to switch to edit mode.
Use the » « and » « keys to select the desired format (European or US) and
press the » « key to confirm the setting.
OK
M

Language

— This function is used to set the language for the menus.
Select the menu items « Settings «, « Instrument « and « Language « in this order,
pressing the » « key after each selection.
Select the desired language from the list and press the » « key to activate it.
OK
OK
Page 48 of 72 Pages
9023927 - 2nd edition - May 2007
Page 49

Function key

— This function is used to set the function which is to be activated when the function
key (the » « key) is pressed briefly. Default setting: Fault report.
Select the menu items » Settings «, » Instrument « and » Function key « in this or-
der, pressing the » « key after each selection.
OK
The menu » Settings «
Select the desired function and press the » « key to activate it. An icon corre-
OK
sponding to the selected function appear on the right side of the display. Possible selections:
Show graph – the measured values are displayed on a time axis,
see page 38
Fault report – existing faults are displayed in clear text, see page 36
Notice
– existing warnings are displayed in clear text, see page 36
report
Fault codes – existing fault codes are displayed in a numerical table,
see page 36
— In measuring mode, briefly pressing the » « key will now activate the
selected function.

Initialise device

This function resets all parameters of the Polytron 7500 to the factory default set­tings. This affects the following parameters:
— Sensor lock. — Gas selection (if the sensor is suitable for measuring several different gases). — Units in the measured value display (normally ppm). — Measuring range for the 4 to 20 mA interface. — Gas configuration of the calibration gas (if the sensor is suitable for calibration
with a replacement gas).
— Calibration interval. (the sensor-specific default values can be found in the
related sensor data sheet).
It also affects the setting parameters for: — Pump output — Alarm parameters — Passwords — Language — Function key — HART interface — Datalogger — Analogue interface
Select the menu items » Settings «, » Instrument « and » Device init. « in this order,
pressing the » « key after each selection.
Select » Confirm « and press the » « key to initialise the device.
9023927 - 2nd edition - May 2007
OK
OK
Page 49 of 72 Pages
Page 50
The menu » Settings «

SW dongle

This group permits the deactivation of individual dongles before they are removed or in the case of a fault in a dongle. A dongle can be reactivated only by restarting the unit.
– Data dongle
Select the menu items » Settings «, » Instrument «, » SW dongle « and » Data
dongle « in this order, pressing the » « key after each selection.
OK
Select the line » Disable function « and press the » « key to disable the
OK
data dongle.
– Sensor test dongle
Select the menu items » Settings «, » Instrument «, » SW dongle « and
» Sensor test dongle « in this order, pressing the » « key after each selection.
Select the line » Disable function « and press the » « key to disable the sensor
OK
OK
test dongle.
– Diagnostic dongle
Select the menu items » Settings «, » Instrument «, » SW dongle « and
» Diagnostic dongle « in this order, pressing the » « key after each selection.
Select the line » Disable function « and press the » « key to disable the diag-
OK
OK
nostic dongle.
Page 50 of 72 Pages
9023927 - 2nd edition - May 2007
Page 51

Sub-menu » Communication «

The sub-menu » Communication « permits various settings to by made for the inter­faces.

HART interface

This group contains the setting functions for the HART interface.
– Polling address
The polling address configures the unit either for the analogue mode (4 to 20 mA) or the multidrop mode. Setting the polling address to " 0 " enables the analogue mode (4 to 20 mA). To enter multidrop mode, the polling address must be set to a value in the range from " 1 " to " 15 ", which disables the analogue interface and freezes it to a constant current of approx. 3 mA. In order to enable the central controller to request the unique identifier (unambiguous HART address) using HART command #0, all Polytron 7500s located on one cable trunk need to be configured with a dif­ferent polling address. It is advisable to choose a subsequent series of addresses, starting with address " 1 ". This setting corresponds to the HART command #6 ("Write Polling Address").
The menu » Settings «
Select the menu items » Settings «, » Communication «, » Hart interface « and
» Polling address « in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the polling address
and press the » « key to confirm the setting.
Press the » « key to confirm the complete polling address.
OK
M
OK
OK
– Unique Identifier
This function can be used to read out the unique identifier (unique HART address), which must be known for the addressing in almost all HART commands. However, knowledge of the unique identifier is necessary only for systems which are not able to read out the unique identifier with the HART command #0 in the short-frame for­mat or the HART command #11. The display corresponds to the address returned by the HART command #0 ("Read Unique Identifier") or #11 ("Read Unique Identifier associated with Tag").
Select the menu items » Settings «, » Communication «, » Hart interface « and
» Identifier « in this order, pressing the » « key after each selection.
OK
— The unique identifier will be displayed.
9023927 - 2nd edition - May 2007
Page 51 of 72 Pages
Page 52
The menu » Settings «
– Tag
The tag may be used to mark a specific transmitter and comprises up to 8 alphanumeric characters. It can also serve for addressing a Polytron 7500, in order to read the unique identifier using HART command #11 ("Read Unique Identi­fier associated with Tag"), even if the polling address is unknown. This presumes that an unambiguous tag has been configured before.
Select the menu items » Settings «, » Communication «, » Hart interface « and
» Tag « in this order, pressing the » « key after each selection.
OK
Use the » « and » « keys to set each position of the tag and press the » «
M
OK
key to confirm the setting.
Press the » « key to confirm the complete tag.
OK

Analogue interface

This group contains the functions needed for the test and setting functions.

Settings for the analogue interface

– Analogue set point / Set measurement range
When the measuring range of the analogue interface must be adjusted. The following corresponds: 0 ppm = 4 mA; Analogue set point / Set measurement range = 20 mA — According to the standard, the standard measuring range of the sensor automat-
ically ends here.
– Warning on/off
This function is used to switch the warning signal » « on the analogue interface on and off. If the presence of a warning is to be signalled via the analogue interface, the warning signal must be switched on. In the case of a warning, the current on the analogue interface is switched for one second to the state "Warning". For the rest of the time, the measured signal is transmitted. The interval between the warning sig­nals and the level of the analogue signal can be configured as desired, see "Warning signal" on page 53 and "Warning level" on page 53.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Warning on/off « in this order, pressing the » « key after each selection.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
OK
Page 52 of 72 Pages
9023927 - 2nd edition - May 2007
Page 53
– Warning interval
This function is used to set the interval between the warning signals » « on the analogue interface.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Warning interval « in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the time interval (in sec-
onds) for T1 and T2 and press the » « key to confirm the setting.
M
OK
OK
[mA]
20
Measured value
4
3
T
T
1
2
t
[s]
The menu » Settings «
04423927_1_en.eps
Press the » « key to confirm the complete time interval.
OK
– Warning level
— This function is used to set the current on the analogue interface for the warning
signal » «.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Warning level « in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the current value and press
OK
the » « key to confirm the setting.
Press the » « key to confirm the complete current value.
OK
M
OK
– Maintenance level
— This function is used to set the current on the analogue interface for the
maintenance signal » «.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Warning level « in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the current value and press
OK
the » « key to confirm the setting.
OK
Press the » « key to confirm the complete current value.
OK
9023927 - 2nd edition - May 2007
Page 53 of 72 Pages
Page 54
The menu » Settings «
Test functions for the analogue interface – Test analogue
— This function is used to set various currents in the range 3 to 22 mA on the ana-
logue interface.
Note: These functions may trigger alarms in the control unit! If necessary, the alarms should be disabled in the control unit before using the functions.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Test analogue « in this order, pressing the » « key after each selection.
If the alarms are disabled in the control unit, confirm the message » Switch off all
alarms « by pressing the » « key.
OK
OK
Use the » « and » « keys to set each position of the current value and press
OK
the » « key to confirm the setting.
Use the »» « and » « keys to select the state » Set current output « and press
OK
the » « key to activate it.
M
M
— The selected current is transmitted on the analogue interface.
Use the » « and » « keys to select the line » Next « and press the » « key
M
OK
to confirm the selection. The function is terminated.
When the alarms in the control unit have been enabled again, confirm the mes-
sage » Switch on all alarms « by pressing the » « key.
OK
– Test fault
— This function is used to set the analogue interface to the fault signal » «.
Note: These functions may trigger alarms in the control unit! If necessary, the alarms should be disabled in the control unit before using the functions.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Test fault « in this order, pressing the » « key after each selection.
Use the » « and » « keys to select » Enable « and press the » « key to
M
OK
OK
activate it.
— The current for the fault signal is transmitted on the analogue interface.
Use the » « and » « keys to select » Disable « and press the » « key to
M
OK
activate it.
— The current for the fault signal is switched off.
– Test warning
— This function is used to set the analogue interface to the warning signal » «.
Note: These functions may trigger alarms in the control unit! If necessary, the alarms should be disabled in the control unit before using the functions.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Test warning « in this order, pressing the » « key after each selection.
OK
Page 54 of 72 Pages
9023927 - 2nd edition - May 2007
Page 55
The menu » Settings «
Use the » « and » « keys to select » Enable « and press the » « key to ac-
M
OK
tivate it.
— The current for the warning signal is transmitted on the analogue interface.
Use the » « and » « keys to select » Disable « and press the » « key to
M
OK
activate it.
— The current for the warning signal is switched off.
– Test maintenance
— This function is used to set the analogue interface to the maintenance
signal » «.
Note: These functions may trigger alarms in the control unit! If necessary, the alarms should be disabled in the control unit before using the functions.
Select the menu items » Settings «, » Communication «, » Analogue interface «
and » Test maintenance « in this order, pressing the » « key after each selec-
OK
tion.
Use the » « and » « keys to select » Enable « and press the » « key to ac-
M
OK
tivate it.
— The current for the maintenance signal is transmitted on the analogue interface.
Use the » « and » « keys to select » Disable « and press the » « key to
M
OK
activate it.
— The current for the maintenance signal is switched off.

LON interface

This function group contains the functions for the LON interface. Operation with LON: see also “Polytron 7500 Operation via LON” on page 62.
– Neuron ID
Every Polytron 7500 has a Neuron chip with its own Neuron ID, with which the Poly­tron 7500 can be identified in the LON network. To display the Neuron ID:
Select the menu items » Settings «, » Communication «, » LON Interface « and
» Neuron ID « pressing the » « key after each selection.
OK
— The Neuron ID is displayed.
– Service PIN
The Polytron 7500 can be commissioned by sending its Neuron ID to the LON net­work with the aid of the function "Service PIN".
Select the menu items » Settings «, » Communication «, » LON Interface « and
» Service PIN « pressing the » « key after each selection.
Use the » « and » « to select » Confirm « and press the » « key to activate
M
OK
OK
this selection.
— The Neuron ID of the Polytron 7500 is transmitted.
9023927 - 2nd edition - May 2007
Page 55 of 72 Pages
Page 56
The menu » Settings «

Sub-menu » Sensor «

The sub-menu » Sensor « can be used to make various settings for the installed sen­sor.

Change sensor

— This function can be used to change a sensor while the unit is running without
sending a fault alarm to the control unit. It also ensures that all sensor data cur­rently in the microprocessor can be saved to the EEPROM of the sensor before the sensor plug is disconnected.
— In principle, a sensor can be replaced at any time. However, for technical safety
reasons, a fault alarm will be activated until a new sensor is connected, in case a sensor is disconnected accidentally.
Select the menu items » Settings «, » Sensor « and » Change sensor « in this or-
der, pressing the » « key after each selection.
— The maintenance signal is transmitted on the interface and the message
» Please remove sensor « is displayed.
Remove the old sensor and plug in the new one (see page 23).
When the new sensor has been installed:
The message » Loading database, please wait « is displayed.
OK
When the sensor data have been loaded:
— The message » Database is loaded « is displayed.
Select » Back to menu « and press the » « key.
OK
The maintenance signal on the interface remains active until the sensor has warmed up. The duration of the warming-up period depends on the type of sensor and its history. If, for example, the sensor had already been warmed up on another unit and it was disconnected only for a short time, the warming-up period may be shorter than that shown in the Instructions for Use for the sensor. See the operating instructions for the sensor for the maximum warming-up period. see the Instructions for Use for the sensor. If the old sensor is replaced with an identical sensor (with the same Part No.), the configuration of the Polytron 7500 (gas type, measuring range, calibration gas, cali­bration interval) remains unchanged. Otherwise, the default values for the sensor (see Instructions for Use for the Dräger­Sensor) are used by the Polytron 7500 if the sensor-lock function (page 57) is disa­bled.

Autocalibration setting

— This function is used to enable and disable the autocalibration (page 41).
Select the menu items » Settings«, » Sensor « and » Set autocal. « in this order,
pressing the » « key after each selection.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
OK
— Autocalibration from the menu "Calibration" can be used only if this function is en-
abled.
Page 56 of 72 Pages
9023927 - 2nd edition - May 2007
Page 57

Sensor test

This group contains the setting functions for the sensor self test. These functions can be used only if the Polytron 7500 is equipped with the Sensor Dongle 83 17 619 or the Sensor Diagnostic Dongle 83 17 860, see page 15.
– Sensor test setting
— This function can be used to activate or reactivate the sensor self test.
Select the menu items » Settings«, » Sensor «, » Sensor test « and » Set sensor
test « in this order, pressing the » « key after each selection.
OK
The menu » Settings «
Use the » « and » « keys to select « Enable « or « Disable « and press the
OK
» « key to activate it.
M
— If the sensor self test is enabled, the Polytron 7500 continually tests the sensor in
order to ensure reliable operation. If the sensor does not pass the self test, a suit­able warning or fault is generated.
– Sensor self-test
— This function is used to start the sensor self-test.
Select the menu items » Settings«, » Sensor «, » XSxx « and » Sensor self test «.
To start the sensor self-test (depending on the sensor and/or device status): se-
lect » Start sensor self-test « with » « key and press the » « key to start.
M
OK
— After a few seconds the result is indicated in the display.
To terminate the function:
Select » Back to menu « and press the » « key.
OK
– Sensor lock
— This function is used to enable or disable the sensor lock.
For Polytron 7500 this function should always be switched on since only one sen­sor with the same Part No. can be replaced.
Select the menu items » Settings «, » Sensor «, » XS–NF
in this order, pressing the » « key after each selection.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
OK
« and » Sensor lock « «
3
Enable = Polytron 7500 will accept a new sensor only if it has the
same Part No. (= Dräger Order No.) as the old sensor and thus the same sensor type.
Disable = Polytron 7500 will accept other sensor types. In this case,
Polytron 7500 uses the default settings for the new sensor, which means that the configuration of the Polytron 7500 will be changed.
9023927 - 2nd edition - May 2007
Page 57 of 72 Pages
Page 58
The menu » Settings «
Sensor configuration (using XS–NF
as an example):
3
This group contains the setting functions for the sensor.
– Gas setting
— This function is used to change the settings for the gas to be measured.
Select the menu items » Settings «, » Sensor «, » XS–NF
order, pressing the » « key after each selection.
OK
« and » Set gas « in this
3
When several measuring gases of the sensor are displayed:
From the list of measuring gases use the » « and » « keys to select and the
OK
» « key to activate it.
M
— The selected gas is indicated.
Use the » « and » « keys to select the unit of measurement (e.g. ppm)
from the list and press the » « key to activate it.
M
OK
— The overview of the settings are displayed.
— If the settings are correct:
Use the » « key to select the line » Confirm « and press the » « key.
M
OK
– Sensor initialisation
— This function is used to set all parameters of the sensors back to the factory de-
fault values.
Select the menu items » Settings «, » Sensor «, » XS–NF
in this order, pressing the » « key after each selection.
Select » Confirm « and press the » « key to initialise the sensor.
OK
OK
« and » Sensor init. «
3
– Set calibration interval
— This function is used to set the calibration interval.
Select the menu items » Settings «, » Sensor «, » XS–NF
in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the calibration interval
(in days) and press the » « key to confirm the setting.
OK
M
OK
« and » Set cal. int. «
3
To confirm the entered calibration interval:
Select » Confirm « and press the » « key.
OK
Page 58 of 72 Pages
9023927 - 2nd edition - May 2007
Page 59

Sub-menu » Datalogger «

The sub-menu » Datalogger « permits various settings to be made for the Datalogger and the Eventlogger. These functions are available only if the Polytron 7500 is equipped with the Data Dongle 83 17 618, see page 15. The contents of the Datalogger or Eventlogger can be evaluated only with the PC software GasVision (Version 5.5 or higher). The contents of the Datalogger for the previous 15 minutes can be viewed with the menu sequence » Information «, » Datalogger « and » Show graph «, page 38.
Datalogger: The Datalogger saves the measured values in accordance with the configuration set under » Set Datalogger «. It can save at least 3000 measured values. If the data is saved at intervals of one minute, this is sufficient for a monitoring period of 50 hours. The monitoring period can be extended considerably by using the setting » Trigger « (page 60).
The menu » Settings «
Eventlogger: The Eventlogger saves unit and sensor events (such as: A1 threshold value exceeded; flow fault in pump). It can save a maximum of 100 events

Datalogger on/off

— This function is used to enable or disable the Data- or Eventlogger.
Select the menu items » Settings «, » Datalogger « and » Datalgr. on/off « in this
order, pressing the » « key after each selection.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
OK

Datalogger setting

This group contains the setting functions for the Datalogger.
– Sample time
— This function can be used to set the sample time for the Datalogger.
Select the menu items » Settings «, » Datalogger «, » Set Datalogger « and
» Sample time « in this order, pressing the » « key after each selection.
OK
Select the desired sample time from the list and press the » « key to
OK
activate it (» «).
9023927 - 2nd edition - May 2007
Page 59 of 72 Pages
Page 60
The menu » Settings «
– Peak / average
— This function can be used to select whether the Datalogger is to save peak or av-
erage values.
Select the menu items » Settings «, » Datalogger «, » Set Datalogger « and »
Peak/average « in this order, pressing the » « key after each selection.
OK
Select » Peak « or » Average « and press the » «« key to activate it.
OK
Peak The maximum concentration value measured during the
selected sample time is saved.
Average The average of all concentration values measured during
the selected sample time is saved.
– Trigger on/off
— This function can be used to enable or disable the threshold criterion for saving
of concentration values.
— If this function is enabled and a suitable trigger value is selected, it is possible to
monitor the measured values for a longer period.
Select the menu items » Settings «, » Datalogger «, » Set Datalogger « and
» Trigger on/off « in this order, pressing the » « key after each selection.
Select » Enable « or » Disable « and press the » « key to activate it.
OK
OK
Enable Concentration values are saved only if they exceed the thresh-
old set under » Trigger value « (referred to the previously saved value).
Disable All measured values which occur during the sample time
are saved.
– Trigger value
— This function can be used to set the trigger value.
This value refers proportionally to the whole measuring range. Example: with a measuring range of 500 ppm a trigger value of 2 % is entered. Then the Datalogger will only store measured values (refer to the last stored meas­ured value) that deviate by more than 10 ppm.
Select the menu items » Settings «, » Datalogger «, » Set Datalogger « and
» Trigger value « in this order, pressing the » « key after each selection.
Use the » « and » « keys to set each position of the trigger value and
press the » « key to confirm the setting.
Press the » « key to confirm the complete trigger value.
OK
OK
M
OK
Page 60 of 72 Pages
9023927 - 2nd edition - May 2007
Page 61
– Stack/roll
— This function can be used to set the operating mode of the Datalogger and
the Eventlogger.
Select the menu items » Settings «, » Datalogger «, » Set Datalogger « and
» Stack/roll « in this order, pressing the » « key after each selection.
OK
The menu » Settings «
Select » Stack « or » Roll « and press the » « key to activate it (» «).
OK
Roll when the Datalogger storage space is use up, the oldest data
will be overwritten first.
Stack when the Datalogger storage is full, no further data can be
saved. An appropriate warning is generated.

Clear Datalogger

— This function is used to delete all data from the Datalogger.
Select the menu items » Settings «, » Datalogger « and » Clear Datalogger «
in this order, pressing the » « key after each selection.
OK
— The message: » Clear Datalogger data « is displayed.
Use the » « key to select the line » Confirm « and press the » « key.
M
OK
— The data are deleted from the Datalogger.

Clear Eventlogger

— This function is used to delete all data from the Eventlogger.
Select the menu items » Settings «, » Datalogger « and » Clear Eventlogger «
in this order, pressing the » « key after each selection.
OK
— The message: » Clear Eventlogger data « is displayed.
Use the » « key to select the line » Confirm « and press the » « key.
M
OK
— The data are deleted from the Eventlogger.
9023927 - 2nd edition - May 2007
Page 61 of 72 Pages
Page 62

Polytron 7500 Operation via LON

Polytron 7500 Operation via LON
There are 3 LEDs behind the display window that indicate the different status of the Polytron 7500. — The red LED indicates an error. — The orange LED indicates communication with the central unit via LON of LON
specific data e.g. sending the Service PIN.
— The green LED indicates the correct operation of the Polytron 7500 when it is
continuously on. When the green LED flashes it indicates a warning in the Polytron 7000.
Every Polytron 7500 has a Neuron Chip with its own Neuron ID, with which the Poly­tron 7500 can be identified in the LON network. To view the Neuron ID:
Select menu items » Settings «, » Communication «, » LON Interface « and
» Neuron ID «.
To commission the Polytron 7500, the Neuron ID can be sent to the central unit using the "Service PIN" function.
Select menu items » Settings «, » Communication «, » LON Interface « and
» Service PIN «.
Select » Confirm « and press the » « key to sent the Neuron ID.
OK
Use the Polytron 7500 Plugin for configuration and commissioning the Polytron
7500. The Plugin is available for free download under: http://www.echelon.com/products/integration/plugin/
Page 62 of 72 Pages
9023927 - 2nd edition - May 2007
Page 63

Technical Data

The measuring range and the measuring properties depend on the DrägerSensor – see the Instructions for Use of the DrägerSensor being used.
Type Microprocessor controlled transmitter with pump and pyrolysis oven
Technical Data
Measuring range and the measuring properties
Flow rate 900 ±100 mL/min;
Signal transmission to the central unit Analogue:
Measured-value signal 4 mA to 20 mA Drift below zero point 3.8 mA Measuring range exceeded 20 mA to 20.5 mA Unit fault <3.2 mA; 21 mA Maintenance signal 3.4 mA ±0.2 mA constant
Digital: HART compatible, transmission on 2-wire shielded cable
Supply voltage 24 V DC ±2 V; 1.5 A
Cable inlet M20x1.5, for cable diameter 6 to 12 mm (0.24" to 0.47")
Ambient conditions Specifications for the sensor: see the Instructions for Use for the DrägerSensor
Dimensions (H x W x D) 150 mm x 125 mm x 300 mm
depend on the type – see the Instructions for Use of the installed DrägerSensor
Hose inside diameter 4 mm, hose outside diameter 6 mm
optionally LON
0 to 40 oC 700 to 1300 hPa 0 to 99 % relative humidity, no condensation
Weight approx. 2.4 kg
CE markings Electromagnetic compatibility (Directive 89/336/EEC)
Ingress protection IP 21
Relay module:
logical channels A1, A2, Fault principle normally energised (for fail-safe operation) contacts 1-pole changeover (SPDT) contact rating 5 A at 30 V DC; 5 A at 250 V AC
9023927 - 2nd edition - May 2007
Page 63 of 72 Pages
Page 64

Order List

Order List
Part name and description Order No.
Pyrolyzer Docking Station
Once per Dräger Polytron 7500
Dräger Polytron 7500 – NF
Measuring range 0 to 50 ppm NF3 (CAS 7783-54-2)
Dräger Polytron 7500 – NF3 LON
Measuring range 0 to 50 ppm NF3 (CAS 7783-54-2)
Dräger Polytron 7500 – PFC
Measuring range 0 to 30 ppm C4F6 (CAS 685-63-2) Measuring range 0 to 30 ppm C5F8 (CAS 559-40-0)
Dräger Polytron 7500 – PFC LON
Measuring range 0 to 30 ppm C4F6 (CAS 685-63-2) Measuring range 0 to 30 ppm C5F8 (CAS 559-40-0)
3
83 18 580
83 18 827
83 18 829
83 18 828
83 18 830

Accessories

Dräger Polytron 7500 Relay Module 83 18 524 Dräger Polytron 7500 Software Dongles: Data Dongle 83 17 618 Sensor Dongle 83 17 619 Sensor Diagnostic Dongle 83 17 860

Calibration accessories

Calibration Bag, 20 L 68 07 068

Spare parts

DrägerSensor XS NF3
for Dräger Polytron 7500 – 83 18 824
DrägerSensor XS PFC
for Dräger Polytron 7500 – 83 18 825 and 83 18 826
Pyrolysis oven NF3 83 18 340 Pyrolysis oven PFC 83 18 820 Spare part set pump (83 18 523)
for the measurement branch
Spare part set pump (83 18 996)
for the principal branch
Dust Filter internal 83 17 348 Cover, unit cover 83 18 528
Page 64 of 72 Pages
68 11 125
68 11 120
83 19 518
83 19 519
9023927 - 2nd edition - May 2007
Page 65

Index

3-wire technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4-wire connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Index
Accessibility
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 64
Accessories, installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Activating info mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Alarm / Relay settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Alarm on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Analogue interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Analogue set point / Set measurement range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Analogue signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Areas subject to explosion hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Autocalibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41, 56
Basic operating procedures
Calibration
Calibration accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Calibration gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 40
Calibration interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
CE markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Change sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Connecting to a HART Multidrop-capable central . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Connecting to the central unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8, 9, 10
Control LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Data dongle Datalogger on/off
Datalogger setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Datalogger status Datalogger, clearing Date and Time Density of the gas
Diagnostic dongle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Dimensions Display
Displays of control LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Drilling templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Electrical connections
Environmental factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Eventlogger, clearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Fault
Fault codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Fault number
9023927 - 2nd edition - May 2007
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 28, 30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Page 65 of 72 Pages
Page 66
Index
Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Flow fault on/off
Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Full-scale value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Function key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Gas settings
HART interface
HART-communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Icons
Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Initialise device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Install the relay module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing the 4 to 20 mA current loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing the docking station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing the LON communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing the Polytron 7500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installing the software dongles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Internal dust filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Language
Last calibration date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Line resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LON interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
LON network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
LON specific data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Maintenance
Maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Maintenance level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Maintenance signal Maximum line lengths Measuring range Measuring range exceeded
Measuring range setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Menu » Calibration « Menu » Information « Menu » Settings « Menu functions Menu structure
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 43
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Page 66 of 72 Pages
9023927 - 2nd edition - May 2007
Page 67
Index
Menu structure – Overview Modules
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Multidrop installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Navigation in the menus
Neuron chip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Neuron ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Next calibration date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Operation via LON Optional extras Order List
Password Calibration
Password Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Password, entering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Passwords when the unit leaves the factory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Peak / average . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Polling address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Preparing for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Pump for the measurement branch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Pump operating time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Pump output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Relay module
Replace the internal dust filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Replace the pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Replace the pyrolysis oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Replace the sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Replacing the pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Replacing the pyrolysis oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Replacing the sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Safety Sensitivity calibration Sensor configuration Sensor diagnostic function Sensor drift below zero point
Sensor initialisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Sensor lock Sensor self-test Sensor temperature Sensor test Sensor test dongle
Sensor vitality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Service PIN
Set ack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Set alarm A1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Settings for calibration interval
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9023927 - 2nd edition - May 2007
Page 67 of 72 Pages
Page 68
Index
Settings for sensor test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Settings for the analogue interface
Show graph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Signal transmission to the central unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Software dongles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 15
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Stack/roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Sub-menu » Communication « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Sub-menu » Datalogger « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38, 59
Sub-menu » Instrument « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 44
Sub-menu » Sensor « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 56
Sub-menu » Span. calibration. « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Sub-menu » Zero calibration « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
SW Dongle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Tag
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Test alarm A1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Test alarm A2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Test fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47, 54
Test functions for the analogue interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Test maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Test warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
The menu » Calibration « . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Time format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Transmission of signals to the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Trigger on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Trigger value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Unique Identifier
Unit calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Unit settings
Warm-up phase Warning interval Warning level Warning number
Warning on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Warning signal Warnings
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Zero gas
Zero point calibration / adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Page 68 of 72 Pages
9023927 - 2nd edition - May 2007
Page 69

Drilling templates

Pyrolyzer Docking Station

Drilling templates
95 mm
120 mm
04523927_1.eps
9023927 - 2nd edition - May 2007
Page 69 of 72 Pages
Page 70
Page 70 of 72 Pages
9023927 - 2nd edition - May 2007
Page 71
9023927 - 2nd edition - May 2007
Page 71 of 72 Pages
Page 72
Thank you for reading this data sheet.
For pricing or for further information, please contact us at our UK Office, using the details
below.
UK Office
Keison Products,
P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.
Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399
Email: sales@keison.co.uk
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the
suitability of this product.
Loading...