Drolet ULTRA FLAME DIRECT VENT GAS STOVE, ULTRA FLAME Installation And Operating Instructions Manual

ULTRA FLAME
DIRECT VENT GAS STOVE
INSTALLATION AND OPERATING INSTRUCTIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. OPEN WINDOWS
2. TURN OFF MAIN GAS SUPPLY
3. DON'T TOUCH ELECTRICAL SWITCHES
4. EXTINGUISH ANY OPEN FLAME
5. IMMEDIATELY CALL YOUR GAS SUPPLIER
Manufactured by :
DROLET STOVES & FIREPLACES INC.
1700 Leon Harmel Quebec, Qc (Canada) G1N 4R9
Tested by :
WARNOCK HERSEY
Rev 07/96 45046A
2
TABLE OF CONTENTS :
TABLE OF CONTENTS : ........................................................................................... 2
GENERAL INFORMATION : .................................................................................... 3
WARNING .................................................................................................................. 4
SPECIFICATIONS : .................................................................................................... 5
TOP, FRONT AND SIDE VIEWS : ............................................................................ 6
INSTALLATION:
SAFETY NOTICE : ......................................................................................... 7
POSITIONING THE STOVE : ........................................................................ 7
VENT TERMINAL LOCATION : .................................................................. 7-8-9
CLEARANCES : ............................................................................................. 10
INSTALLATION OF THE UNIT : ................................................................. 10-11
VENTING KITS :
STRAIGHT OUT INSTALLATION ............................................................... 12
CORNER INSTALLATION: ........................................................................... 12-13
BASEMENT INSTALLATION: ..................................................................... 13
DISTANT INSTALLATION : ........................................................................ 15
VENTING SYSTEM : ................................................................................................. 16
VENT TERMINAL STRAIGHT OUT AND CORNER INSTALLATION: .............. 16-17
VENT TERMINAL, BASEMENT INSTALLATION: .............................................. 17
VENT TERMINAL, ROOF INSTALLATION : ......................................................... 18
INSTALLATION OF SIDE PANELS AND PEDESTAL .......................................... 18-19
GLASS FRONT REMOVAL, CLEANING AND INSTALLATION: ....................... 20
BURNER REMOVAL AND INSTALLATION ......................................................... 20
LOG INSTALLATION : .............................................................................................. 22
EMBER KIT INSTALLATION : ................................................................................ 23
REFRACTORY PANELS INSTALLATION: ............................................................ 24
GOLD TRIM INSTALLATION: ................................................................................. 24
OPERATING INSTRUCTIONS: ................................................................................ 25-26
MAINTENANCE INSTRUCTIONS ........................................................................... 27
OPTIONAL PARTS: ................................................................................................... 28
REPLACEMENT PARTS ........................................................................................... 28
LIMITED 5-YEAR WARRANTY .............................................................................. 29
3
GENERAL INFORMATION :
The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h with propane. It features a thermostatic modulating valve and a constant pilot. This means that the flame will vary in height according to room temperature. The colder the ambient temperature the larger the flames. The valve is also independent of any exterior electrical supply. Your appliance will therefore continue to heat your house in the event of a power failure.
For increased efficiency, we have included a 140 CFM blower with speed control and thermo­switch. Your fan will therefore turn itself on or off automatically, if you desire.
Read these instructions and consult your local building authorities before installing this appliance. Install the unit and its venting system only as described in these instructions.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This gas stove has been tested by WARNOCK HERSEY according to the CAN-CGA-2.22M82_ INTERIM #41 and engineering buletin #68 for Canada and ANSI Z21,50, 50A, 50B for USA.
It is mobile home approved.
The unit can be installed in a range of altitude from 0 to 4 500 ft (0-1 370 m).
This appliance must be connected to a venting system.
Use only with Drolet direct vent kit, supplied by manufacturer.
4
WARNING
INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.
DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE.
HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE.
ADVISE ADULTS AND CHILDREN TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS BE KEPT CLEAN.
DO NOT MODIFY THIS APPLIANCE.
THE OPENINGS IN THE GAS STOVE PEDESTAL SHOULD NEVER BE BLOCKED.
PROVIDE ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND PROPER OPERATION.
5
SPECIFICATIONS :
Dimensions : height : 29-3/16" width : 26-5/16" depth : 19-5/8"
Glass : front 18-3/16" x 15-31/32" 1400oF clear ceramic sides 5-1/16" x 15-31/32" 1400oF clear ceramic
Fuel : Natural Gas Propane Input : 30 000 26 000 Btu/h Manifold pressure : 3.5 10 in w.c. Min inlet pressure : 5 11 in w.c. Max. inlet pressure : 7 14 in w.c.
Vent size : 5" inner 8" outer coaxial vent pipes for straight out and corner kits installation. 4" inner 8" outer coaxial vent pipes for basement or distant kit installation
Valve : SIT Model EUROSIT 630 Thermostatic modulating
Blower : Variable speed, 140 CFM Thermo-switch : 120oF "ON", 90oF "OFF" bi-metal type, Pressure relief device: Burst disc Efficiency : 75 % heating
Maximum lenght of venting pipe allowed: Straight out installation: - Vertical rise: 0’
- Max horizontal lenght: 5'
- Max combination of both: 5’
Corner installation: - Vertical rise: 0’
- Max horizontal lenght: 5'
- Max combination of both: 5’
Basement or distant - Max vertical rise: 25' kit installation: - Max horizontal lenght: 10'
- Max combination of both: 25' * Maximum number of elbows 90° or 45°: 3
6
TOP, FRONT AND SIDE VIEWS :
INSTALLATION:
5"
26-5/16"
13-5/32"
8"
19-5/8"
Top view
13-5/8"
26-5/16"
17-1/2"
24-1/8"
Front view
19-5/8" 2-5/8"
6-1/8"
18-7/8"
29-3/16"
10-5/16"
18-1/4"
Side view
7
INSTALLATION
SAFETY NOTICE :
Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes and with current CAN/CGA B149.1 & B149.2 installation codes for gas appliances.
INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. THIS GAS FIREPLACE MUST BE VENTED OUTSIDE.
The gas stove must be electrically grounded in accordance w ith the current CSA C22.1 Canadian Electrical Code.
POSITIONING THE STOVE :
Always locate the stove as near as possible to an outside wall to keep vent length to a minimum. Provide adequate accessibility clearances for servicing and proper operation. Never install the stove in a hallway or near a staircase since it may block the way in case of a fire.
VENT TERMINAL LOCATION :
Your Ultra Flame stove vents through a vent terminal installed on the roof or on the outside of any exterior wall of your house. Many restrictions apply to the vent terminal location that should be considered before locating your stove.
The following drawing presents a summary of most of these restrictions.
8
L9002.TIF
A = 12" Clearance above grade, veranda, porch, deck or balcony B = 12" Clearance to window or door that may be opened C = 12" Clearance to permanently closed window D = 18" Vertical clearance to ventilated soffit located above the terminal within a horizontal
distance of 2 feet (60 cm) from the centre-line of terminal (straight out or corner
installation) D = 24" (Basement or distant installation) E = 12" Clearance to unventilated soffit (straight out or corner installation) E = 24" (Basement or distant installation) F = 12" Clearance to outside corner G =12" Clearance to inside corner H = Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from
the centre-line of the regulator * I = 72" Clearance to service regulator vent outlet J = 12" Clearance to non-mechanical air supply inlet to building or the combustion air inlet to
any other appliance K = 72" Clearance to a mechanical air supply inlet L = 84"  Clearance above paved sidewalk or a paved driveway located on public property M =36"  Clearance under veranda, porch, deck, or balcony
9

A vent shall not terminate directly above a sidewalk or paved driveway which
is located between two single family dwellings and serves both dwellings *

Only permitted if veranda, porch, deck, or balcony is fully open on a minimum
of 2 sides beneath the floor *
* As specified in CGA B149 Installation Codes (1991)
NOTE: Local codes or Regulations may require different clearances
In addition, the following restrictions also apply.
When the vent terminal is accessible, a certified guard shall be installed around the terminal. This guard is available as an option, identified as part #E5480, for straight and corner terminals and #E5482 for the basement terminal.
The vent terminal may not be recessed into the wall or siding.
The vent terminal shall not terminate :
- Within 3 ft. of a building mechanical air supply.
- Less than 12 inches from a perpendicular wall.
- In an area which is allocated to the occupancy.
- Under a window that pivots open.
In addition, in a structure with three walls and a roof , the following restrictions applies :
a) The minimum distance between the two side walls must be 72". b) The roof must not exceed the walls more than 24". c) If both those conditions applies, the clearance shall be as follow:
- 18" to a side wall.
- 12" to an unventilated soffit, 24" for basement or distant installation.
- 18" to a ventilated soffit, 24" for basement or distant installation.
CLEARANCES :