Drolet SIT 0.820.634, SIT 0.820.633 User Manual

ULTRA FLAME
DIRECT VENT GAS STOVE
INSTRUCTIONS MANUAL
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE
OF LOCAL CODES, WITH THE CURRENT NATIONAL FUEL GAS CODE ANSI Z223.1
(USA) OR THE CURRENT CAN/CGA B149 INSTALLATION CODES (CANADA).
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from neighbour’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
PLEASE KEEP THIS INSTRUCTIONS MANUAL
FOR FUTURE REFERENCE
000920/45046A
ULTRA FLAME DIRECT VENT GAS STOVE 1
TABLE OF CONTENTS
GENERAL INFORMATION.................................................................................................................................................... 2
WARNING.............................................................................................................................................................................. 2
TECHNICAL SPÉCIFICATIONS............................................................................................................................................ 3
Dimensions........................................................................................................................................................3
Burner................................................................................................................................................................4
Gas Valve SIT 820 Nova mV............................................................................................................................4
Pressure Adjustments...................................................................................................................................4
Available Wall Venting Kits ...............................................................................................................................5
Available Options ..............................................................................................................................................5
SELECTING TYPICAL INSTALLATION ................................................................................................................................6
Safety Notice.....................................................................................................................................................6
Positioning the Stove ........................................................................................................................................6
Clearance to combustibles................................................................................................................................6
Critical Length of Venting Pipes........................................................................................................................7
Terminal Vent Location.....................................................................................................................................7
INSTALLATION OF YOUR STOVE.......................................................................................................................................8
Pedestal cover ..................................................................................................................................................8
Installation of Wall Venting Kits.........................................................................................................................9
Direct Vent Kit ...............................................................................................................................................9
Direct Vent Kit for Corner Installation..........................................................................................................10
Direct Vent Kit for Basement Installation ....................................................................................................12
Direct Vent Kit for Floor Installation.............................................................................................................14
Gas Piping...................................................................................................................................................16
Electrical Connections.....................................................................................................................................16
Logs Installation ..............................................................................................................................................17
Ember Kit Installation......................................................................................................................................17
Bay Window Installation..................................................................................................................................17
OPERATION OF YOUR STOVE ......................................................................................................................................... 18
For your safety ................................................................................................................................................18
Lighting Instructions........................................................................................................................................18
Shut down Instructions....................................................................................................................................19
Optional Blower...............................................................................................................................................19
Optional Wall Thermostat................................................................................................................................19
MAINTENANCE INSTRUCTIONS.......................................................................................................................................20
Yearly maintenance ........................................................................................................................................20
Burst Disc Replacement..................................................................................................................................20
Bay window.....................................................................................................................................................20
Cleaning......................................................................................................................................................20
Repairing.....................................................................................................................................................20
Burner..............................................................................................................................................................21
Removing the Burner ..................................................................................................................................21
Burner Installation .......................................................................................................................................21
Air Shutter Adjustment ................................................................................................................................21
Gas Valve SIT 820 mV....................................................................................................................................21
Maximum Pressure Adjustment, Altitude Installation..................................................................................21
Pilot Assembly.................................................................................................................................................22
OPTIONS............................................................................................................................................................................. 22
REMPLACEMENT PARTS .................................................................................................................................................. 22
LIMITED WARRANTY ......................................................................................................................................................... 23
ULTRA FLAME DIRECT VENT GAS STOVE 2
GENERAL INFORMATION
The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency gas appliance with a maximum input rating of 30 000 Btu/h (8,8 kW) with natural gas or 26,000 Btu/h (7,6 kW) with propane. It features an adjustable millivolt valve and a constant pilot independent of any electrical source. Your appliance will therefore continue to heat your house in the event of a power failure. You can set the height of the flame to your liking by turning the adjusting knob.
For increased efficiency, we offer as an option a 130 CFM blower. Speed control, thermo-switch and electrical wiring are pre-installed on your stove. Easy to hook up, your fan will therefore turn itself « ON » and « OFF » automatically.
An optional thermostat is also available for automatic room temperature control. This appliance must be connected to a venting system. Read these instructions and consult your local building
authorities before installing this appliance. Install the unit and its venting system only as described in these instructions. Use only with Drolet Direct Vent Kit, supplied by manufacturer.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This gas stove has been tested by Intertek Testing Services according to CGA-2.22-M96 and CAN/CGA-2.17­M91 for Canada and ANSI Z21.50-1996 and UL307B-1995 for USA.
It is mobile home approved. This appliance must be installed in accordance with the current Standard Mobile Homes, CAN/CSA Z240 MR OR CAN/CSA Z240RV, RECREATIONAL VEHICLES or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such a standard is not applicable, the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities, ANSI/NFPA 501A or with the current Standard for RECREATIONAL VEHICLES, ANSI A119.2/NFPA 501C.
The unit can be installed in a range of altitude from 0 to 4 500 ft (0-1 370 m) in Canada. In USA see gas codes for operating above 2000 ft.

WARNING

Installation should be done by a qualified installer.
Do not burn wood or any other material in this appliance.
Hot when in operation. Keep children, furniture, clothing and flammable material away
from the appliance.
Inform adults and children to the hazard of high surface temperatures and that they should stay away to avoid burns or clothing ignition.
Young children should be supervised when they are in the same room as the appliance.
The appliance should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
It is imperative that the control compartments, burners and circulating air passageways be kept clean.
Do not modify this appliance.
The openings in the gas stove pedestal should never be blocked.
Provide adequate accessibility clearances for servicing and proper operation.
ULTRA FLAME DIRECT VENT GAS STOVE 3

TECHNICAL SPÉCIFICATIONS

Dimensions

Dimensions

Height : 29 in 735 mm
Width : 26 in 920 mm Depth : 23 in 585 mm
Ceramic Glass Front : 18 3/16 in x 15 15/16 in
462 mm x 405 mm Sides : 5 1/16 in x 15 15/16 in 129 mm x 405 mm Weight : 140 lbs 64 kg Color : Metallic Black
Clearances to Combustibles
Back : 1 po 25 mm
Side : 14 po 355 mm
Corner : 4 po 100 mm
Top : 36 po 915 mm
TOP VIEW
Floor :combustible
Note 1 : Your stove has been successfully certified while installed on a wood floor. Do not install your stove on carpet. Choose instead ceramic tile or wood floor.
Note 1
FRONT VIEW SIDE VIEW
ULTRA FLAME DIRECT VENT GAS STOVE 4

Burner

Natural Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : Inlet Pressure INWC (kPa) minimum : maximum : Manifold Pressure INWC (kPa) minimum : maximum : Burner orifice, ∅ : Injecteur du pilot. ∅ :
20 000 (5,9) 30 000 (8,8) 5,0 (1,3) 7,0 (1,8) 1,8 (0,5) 3,5 (0,9)
36 52 51 30
20 000 (5,9) 26 000 (7,6) 11,0 (2,8) 14,0 (3,5) 7,0 (1,8) 10,0 (2,5)

Gas Valve SIT 820 Nova mV

Natural Gas Propane LP
Gas Valve :
Your stove is equipped with a sophisticated gas control valve, which will give you a safe use of your appliance. The gas control valve SIT 820 Nova mV operates without electricity due to the energy given by the pilot flame and captured by the thermo-generator. (also called thermopile). The admission of the gas fuel to the burner is done only under safe conditions.

Pressure Adjustments

Adjustments to the valve assembly must be performed by a qualified service person.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa);
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less that ½ psi (3.5 kPa);
NATURAL GAS
The inlet supply or line pressure must be a minimum of 5 INWC and a maximum of 7 INWC. The orifice has a #36 hole. ELEVATION INPUT RATING 0-4500 ft (0-1400m) 30 000 BTU/h (8.8 kW) over 4500 ft (1400 m) + 30 000 BTU/h (8.8 kW) less 4% per 1000 ft (300 m) or reduce manifold pressure by 0.25 INWC per 1000 ft (300 m) GAZ PROPANE The inlet supply or line pressure must be a minimum of 10.5” WC and a maximum of 12” WC. The orifice has a #52 hole. ELEVATION INPUT RATING 0-4500 pi (0-1400 m) 26 000 BTU/h (7.6kW) 4500 pi (1400m)+ 26 000 BTU/h (7.6kW) moins 4% par 1000 pi (300m) or reduce manifold pressure by 1 INWC per 1000 ft
NOTE : The input rating should always be checked when first running this appliance. To do this, verify inlet valve pressure and manifold pressure,. Adjust manifold pressure to meet values range as indicated in burner characteristics table.
Model SIT 0.820.634
Nova mV
Model SIT 0.820.633
Nova mV
ULTRA FLAME DIRECT VENT GAS STOVE 5

Available Wall Venting Kits

Venting Kit for Direct Installation AC05506 Venting Kit for Corner Installation AC05507
DESCRIPTION
Outer pipe ( 8 in.) for admission of fuel-air in carbon steel, black 24GA ;
Inner flexible pipe ( 5 in.) in aluminum allowing the exhaust of the flue ;
Snorkel type vent terminal in galvanized steel.
DESCRIPTION
Outer pipe ( 8 in.) for admission of fuel-air in carbon steel, black 24GA ;
Inner flexible pipe ( 5 in.) in aluminum allowing the exhaust of the flue ;
O
45
Snorkel type vent terminal in galvanized steel.
elbow ( 8 in.)
Venting Kit for Floor Installation AC05502 Venting Kit for Basement Installation AC05509
DESCRIPTION
Outer pipe ( 8 in.) for admission of fuel-air in carbon steel, black 24GA;
Inner flexible pipe ( 4 in.) in aluminum allowing the exhaust of the flue;
O
2-90
elbow and straight pipes ( 8 in.) included ;
Small vent terminal in galvanized steel.

Available Options

Blower AC05529
Flow rate : 130 CFM (3.68m
Thermoswitch starting the blower at 110
stop it at 90
O
F (32 OC)
Speed control (rheostat)
Thermostat AC05558
3
/min)
O
F (43 OC) and
DESCRIPTION
Outer pipe ( 8 in.) for admission of fuel-air in carbon steel, black 24GA ;
Inner flexible pipe ( 5 in.) in aluminum allowing the exhaust of the flue ;
O
2-90
elbow and straight pipes ( 8 in.) included ;
Snorkel type vent terminal in galvanized steel.2
ULTRA FLAME DIRECT VENT GAS STOVE 6

SELECTING TYPICAL INSTALLATION

Safety Notice

Improper installation may result in a house fire. Follow installation directions. Installation must be done in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 installation codes for gas appliances (Canada) and current National Fuel Gas Code ANSI Z223.1 (USA).
A qualified installer must do installation.
This gas stove must be vented outside.
This gas stove, when installed with optional blower or hand held remote, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the national electrical code, ANSI/FPA 70, or the Canadian Electrical code, CSA C22.1.

Positioning the Stove

Always locate the stove as near as possible to an outside wall. Keep horizontal run of vent pipe as short as possible;
Provide adequate clearances around air openings into the combustion chamber. Provide adequate accessibility clearances for servicing and proper operation.
The ULTRA FLAME may be installed in a bedroom provided that all required clearances are met and a wall thermostat is installed.
Never install the stove in a hallway or near a staircase as it may block the way in case of a fire
A gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning
appliance.

Clearance to combustibles

Clearance between the stove and any combustible material must also be maintained while installing your appliance.
CLEARANCE Back (in) 1 Side (in)) 14 Corner (in) 4 Top (in) 36 Front (in) 12 Pipe (in) 1
Floor Combustible
Direct Installation
Note 1 :Your stove has been successfully certified while installed on a wood floor. Do not install your stove on carpet. Choose instead ceramic tile or wood floor.
Clearance between wall and the pipe is 1". Do not install the vent pipe in an enclosed area or through an insulated wall without a radiation shield ( # E-5710)
Note 1
Corner Installation
Basement or Floor Installation
ULTRA FLAME DIRECT VENT GAS STOVE 7

Critical Length of Venting Pipes

The following table shows maximum length to be respected while installing your appliance:
In conclusion:
If you have no rise (Vertical run= 0 ft) : The
If you have a known horizontal run :
If you have a vertical run shorter than 5 ft :
If you have a vertical run longer than 5 ft :
Note : 1-90O elbow is equivalent to 5 ft of horizontal run ; 1-45O elbow is equivalent to 2,5 ft of horizontal run.
maximum horizontal run is 5 ft ; Minimum vertical run = Horizontal run – 5 ft ; Maximum horizontal run = Vertical run + 5 ft. Maximum horizontal run = 10 ft.

Terminal Vent Location

Your Ultra Flame stove vents through a vent terminal installed on the roof or on the outside of any exterior wall of your house. Many restrictions apply to the vent terminal location that should be considered before locating your stove. The following drawing presents a summary of most of these restrictions.
LEGEND A. 12" Clearance above grade, veranda, porch, deck or balcony B. 12" Clearance to window or door that may be opened C. 12" Clearance to permanently closed window D. 18" Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm)
from the center-line of terminal (direct or corner installation)
24" Vertical clearance to ventilated soffit (Basement installation)
E. 12" Clearance to unventilated soffit, (straight out or corner installation)
24" Clearance to unventilated soffit, (Basement installation)
F. 12" Clearance to outside corner G. 12" Clearance to inside corner H. 36" clearance to each side of the centreline extended above the meter / regulator assembly to a maximum vertical
distance of 15ft (4.57M)
I. 36" clearance to service regulator vent outlet J. 12" Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
Loading...
+ 16 hidden pages