Drolet NG1800 User Manual

OWNER`S MANUAL

DROLET
NG1800 WOODSTOVES:
AUSTRAL, AZIMUTH, BALTIC, LEGEND AND
MYRIAD
AGENCY PHASE II CERTIFIED
WOODSTOVES
Verified and tested following
ULC S627 and UL 1482 Standards by:

Intertek Testing Services

Manufactured by : STOVE BUILDER INTERNATIONAL INC..
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : (418 ) 527-3060
Fax : (418 ) 527-4311
www.drolet.ca
READ AND KEEP THIS MANUAL FOR REFERENCE
45063A_rev. fev.03.doc

TABLE OF CONTENTS

INTRODUCTION............................................................................................................... 2
TECHNICAL SPECIFICATIONS.......................................................................................3
ASSEMBLY....................................................................................................................... 4
BALTIC.......................................................................................................................... 4
AUSTRAL, AZIMUTH, LEGEND AND MYRIAD............................................................ 5
DOOR ADJUSTMENT................................................................................................... 6
INSTALLATION................................................................................................................. 7
POSITIONING THE STOVE.......................................................................................... 7
FLOOR PROTECTOR................................................................................................... 8
CLEARANCES FROM COMBUSTIBLES......................................................................9
REDUCED CLEARANCES (CANADA ONLY)............................................................. 10
CHIMNEY.................................................................................................................... 11
CHIMNEY CONNECTOR (STOVE PIPE).................................................................... 12
TYPICAL INSTALLATIONS......................................................................................... 13
OUTSIDE COMBUSTION AIR..................................................................................... 17
WOODSTOVE UTILISATION.......................................................................................... 18
AVERAGE ENERGY YIELD OF ONE AIR DRIED CORD OF CUT WOOD................ 18
TESTING YOUR WOOD ............................................................................................. 19
THE FIRST FIRES....................................................................................................... 19
IGNITION..................................................................................................................... 19
HEATING..................................................................................................................... 20
RELOADING................................................................................................................ 21
CREOSOTE FORMATION AND NEED FOR REMOVAL............................................ 21
ASH DISPOSAL .......................................................................................................... 22
MAINTENANCE.............................................................................................................. 23
GLASS......................................................................................................................... 23
GASKETING................................................................................................................ 23
PAINT.......................................................................................................................... 23
LIMITED LIFETIME WARRANTY.................................................................................... 24
1

INTRODUCTION

SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation, operation and maintenance of the model you have chosen.
The instructions pertaining to the installation of your wood stove comply with ULC-S627 and UL-1482 standards.
Read this entire manual before you install and use your new stove. If this stove is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury, or even death.
Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit.
Keep this instructions manual for future references.
CAUTIONS:
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
DO NOT BURN WASTES, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
2

TECHNICAL SPECIFICATIONS

Combustible: Recommended Surface
Wood
500 to 1 800 ft
2
(46 to 167 m2)
Heating Capacity : E.P.A :
30 800 BTU/h
(9.02 kW)
Efficiency : Emissions: Colors :
Flue Pipe Diameter : Chimney type :
Minimum Chimney Height : Maximum Log Length :

Dimensions

19 1/2’’ (495 mm)
Overall:
Baltic, Myriad : Austral, Legend : Azimuth :
23 ¾ x 26 ½ x 31 ½ "
(603 x 673 x 800mm)
23 ¾ x 26 ½ x 30 ¼ "
(603 x 673 x 768mm)
23 7/8 x 30 ¼ x 29 ½ "
(606 x 768 x 749mm)
Combustion Chamber : Width x Depth :
Volume :
3.228 pi
Door Opening : All Models :
Pyroceram Glass Door :
All Models :
15 3/16 ’’ x 11 1/4 ’’
Weight: Austral : Azimuth : Baltic : Legend : Myriad :
65 %
5.7 g/h
Flat Black
6’’ (152 mm)
2 100°F (650 °C)
12’ (3,66 m)
L x P x H
W x D
18 ¼ x 20 ¼ ’’
(464 x 514 mm)
3
(0,092 m3)
W x H
15 ½ x 12 1/4’’
(394 x 311 mm)
W x H
(386 x 286 mm)
342 lbs ( 116 Kg) 370 lbs ( 127 Kg) 388 lbs ( 188 Kg) 383 lbs ( 188 Kg) 381 lbs ( 188 Kg)
OPTIONS PART NUMBER
Thermodisc All Models: AC05530 Outside air intake kit All Models: AC02080
3

ASSEMBLY

BALTIC

Pedestal Base Installation:
1. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws.
2. Slide the ash pan in position.
Side Panels and Ash Lip Installation:
1. Start by fixing the front part of the decorative side in the two clips welded on the sides of the fire box.
2. Then, fix the back of the decorative side with two screws and washers supplied. Line up the decorative side parallel to the side of the appliance.
4

AUSTRAL, AZIMUTH, LEGEND AND MYRIAD

Ash Pan Installation:
5

DOOR ADJUSTMENT

In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust:
Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip")
Turn the handle counter clock wise one turn to increase pressure
Re-install the lock pin (spring pin) with a small hammer
Figure 1: Door Adjustment
6

INSTALLATION

SAFETY NOTICE
IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK
OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.
USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR "FRESHEN UP" A FIRE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE STOVE.
IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE
OF OXYGEN. CALL THE FIRE DEPARTMENT.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN
REQUIRED.

POSITIONING THE STOVE

It is very important to position the wood stove as close as possible to the chimney, and in an area that will favour the most efficient heat distribution possible throughout the house. The stove must therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower.
The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.
A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fall to respect required clearances.
7