Drolet GEMINI 1200, GEMINI 1500, LORRAINE, CASSANDRA, JANET Installation Manual

THE INSTALLATION MANUAL FOR GEMINI 1200 AND GEMINI 1500 WOODSTOVES
Manufactured by DROLET STOVES & FIREPLACES INC
45041a
.
Rev 07/96
________________________________________________ THE INSTALLATION MANUAL FOR
GEMINI 1200 ET GEMINI 1500 WOODSTOVES ________________________________________________
DROLET STOVES & FIREPLACES Inc. is pleased to congratulate you on your new acquisition. We would like to assist you in drawing the utmost benefit from the unit which you have selected. Therefore, we would like to offer a few useful hints on heating with wood and on controlled combustion in particular.
Moreover, the technical data specifications pertaining to the model which you have chosen are outlined on the following pages, including instructions for installation, use and maintenance.
The installation instructions in accordance with the standards set by ULC #S627, must be followed exactly in order to avoid the possibility of major problems.
Your instruction booklet is a gold mine of information. Keep it handy.
1
________________________________________________ INSTALLATION
________________________________________________
Your stove must be mounted on fireproof surface. If you have decided to mount it on an area where flooring material is not fireproof, then you must add a panel of asbestos between the stove and the floor. The thickness and dimensions of this panel differ according to each model, as outlined in the following chart.
__________________________________________________________________________ Model Thickness Panel Panel Panel of Protrusion Protrusions Protrusion panel at front at sides at back __________________________________________________________________________
Gemini 1200 3/8" (7mm) 18" (457mm) 6" (150mm) 6" (150mm) __________________________________________________________________________
Gemini 1500 3/8" (7mm) 18" (457mm) 6" (150mm) 6" (150mm) __________________________________________________________________________
Note: Asbestos panel can be replaced by a ceramic of gauge 18 sheet metal.
1) Whether you choose to install your stove cornerwise in a room or parallel to a wall, you must adhere to the specifications for distances to be respected. These are clearly illustrated for each particular model.
Gemini 1200..............................................................................................................drawing #1
Gemini 1500..............................................................................................................drawing #1
2) Note : Only competent authorities can approve shorter distances.
3) Avoid placing wood or other inflammable substances too close to your heating unit. As we have already stipulated, make sure that the proper distances are respected between your unit and any inflammable substances.
2
______________________________________________________
SMOKE EVACUATION SYSTEM ________________________________________________
A good smoke evacuation system will ensure superior performance if you observe these precautionary measures:
1) The stove pipe and the chimney must be of the same dimension as the woodstove outlet, minimum height 15 feet from floor to chimney top.
2) If you use an insulated chimney, make sure that it has the necessary approvals. You must follow very closely the instructions given by the manufacturer.
3) If you choose to equip your stove with a masonry chimney, we strongly recommend that you call on specialist. Make sure that the masonry encasement of the clay tiles is 8 inches thick. This thickness is recommended so that the chimney can retain its heat, thereby preventing excessively rapid cooling of the gases, which, in turn, results in excessive creosote and soot formation.
4) Should a spark arrestor be required at the end of your chimney, it must be inspected at frequent intervals in order to prevent any accumulation of creosote and soot from blocking the chimney.
5) We recommend that you use a chimney connector pipe made of conventional steel of a minimum 24 gauge thickness. Read carefully your installation manual provided by the chimney manufacturer before proceeding to the installation. Check with your local building code before making a hole in a wall or ceiling for a chimney opening.
6) Your smoke outlet system should be completely airtight. In order to achieve this, assemble the pipe lengths in position, male end facing downwards. Each length should then be fixed in place with three metal screw per section, each one at an equal distance apart. (See illustration page 11).
7) The chimney pipe system should be straight and short. If a horizontal installation is unavoidable, you must allow a minimum slope of 1/4" per foot.
8) The stove should not be connected to a central heating unit.