Drolet 75281 User Manual

OWNER`S MANUAL
DROLET EPA WOODSTOVES
HT-1600 & HT-2000
US ENVIRONMENTAL PROTECTION
WOODSTOVES
Vérified and tested following
ULC S627 et UL 1482 Standards by:
READ AND KEEP THIS MANUAL FOR REFERENCE
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : ( 418 ) 527-3060
Fax : ( 418 ) 527-4311
www.drolet.ca
45060A
TABLE OF CONTENTS
INTRODUCTION .................................................................................................................... 2
TECHNICAL SPECIFICATIONS ............................................................................................ 3
TIPS ON WOOD HEATING .................................................................................................... 4
ASSEMBLY ............................................................................................................................ 5
PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION ........................................... 5
BRICKS AND INSULATION INSTALLATION (HT-1600) .................................................... 6
BRICK AND INSULATION INSTALLATION (HT-2000) ...................................................... 7
AIR TUBES INSTALLATION (HT-2000): ............................................................................ 8
DOOR ADJUSTMENT ........................................................................................................ 9
THE BENEFITS OF INSTALLING A BLOWER .................................................................... 10
INSTALLATION .................................................................................................................... 11
POSITIONING THE STOVE ............................................................................................. 11
FLOOR PROTECTOR ...................................................................................................... 12
CLEARANCES ................................................................................................................. 13
REDUCED CLEARANCES ............................................................................................... 14
CHIMNEY ......................................................................................................................... 15
CHIMNEY CONNECTOR (STOVE PIPE) ......................................................................... 16
TYPICAL INSTALLATIONS .............................................................................................. 17
WOODSTOVE UTILIZATION ............................................................................................... 21
TESTING YOUR WOOD .................................................................................................. 22
THE FIRST FIRES ............................................................................................................ 22
IGNITION .......................................................................................................................... 22
HEATING .......................................................................................................................... 23
RELOADING ..................................................................................................................... 24
CREOSOTE FORMATION AND NEED FOR REMOVAL ................................................. 24
ASH DISPOSAL ............................................................................................................... 25
MAINTENANCE ................................................................................................................... 26
GLASS .............................................................................................................................. 26
GASKETING ..................................................................................................................... 26
PAINT ............................................................................................................................... 26
DROLET LIMITED LIFETIME WARRANTY ......................................................................... 27
REGISTER YOU WARRANTY ONLINE
To receive full warranty coverage, you will
need to show evidence of the date you
purchased your stove. Keep your sales
invoice. We also recommend that you register
your warranty online at
www.drolet.ca
Registering your warranty online will help us
track rapidly the information we need on your
stove.
1
INTRODUCTION
SBI INC., one of the most important wood stove and fireplace manufacturers in Canada,
congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation, operation and maintenance of the model you have chosen.
The instructions pertaining to the installation of your wood stove comply with ULC-S627 and UL-1482 standards.
Read this entire manual before you install and use your new stove. If this stove is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury, or even death.
Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit.
Keep this instructions manual for future references.
CAUTIONS:
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
DO NOT BURN WASTES, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
2
TECHNICAL SPECIFICATIONS
Combustion Type: Recommended Surface
(84 à 149 m2) (93 à 186 m2) Heating Capacity : E.P.A :
Real :
Efficiency : Average Emission: Colour : Flue Pipe Diameter : Chimney type : Minimum Chimney Height : Maximum Log Length : Dimensions Overall:
On Pedestal Model :
Combustion Chamber : Width x Depth :
Volume : Door Opening :
Width x Height :
Pyroceram Glass Door :
Width x Height :
Mass:
OPTIONS
Blower 75 CFM (2,83 m3/min) with variable speed control Thermodisc 100-120oF (37-490C). Yes Yes
25 1/8 x 26 ½ x 32 5/8‘’
HT-1600 HT-2000
Wood Wood
900 à 1 600 ft2 1 000 à 2 000 ft2
40 000 BTU/h
(11,7 kW)
70 000 BTU/h
(20,5 kW)
71,3% 72,2%
3,3 g/h 3,8 g/h
Metallic Black Metallic Black
6’’ (152 mm) 6’’ (152 mm)
2 100°F (650 °C) 2 100°F (650 °C)
12’ (3,66 m) 12’ (3,66 m)
18’’ (457 mm) 19’’ (483 mm)
W x D x H
(638 x 673 x 828mm)
18 ¼ x 15 ¼’’
(464 x 387 mm)
3
2,5 pi
(0,07 m3)
17 ¾ x 9 1/8'’
(425 x 222 mm)
16 ¼ x 9 ½’’
(432 x 267 mm)
420 lbs (190 Kg) 560 lbs (254 Kg)
Yes
Yes
60 200 BTU/h
(17,6 kW)
95 000 BTU/h
(27,8 kW)
W x D x H
28 3/8 x 29 ½ x 34 3/8
(721 x 749 x 873mm)
22 ½ x 18’’
(572 x 457 mm)
3,4 pi3 (0,09 m3)
17 3/4 x 9 1/8
(450 x 234 mm)
16 1/4 x 9 1/2
(413 x 241 mm)
3
TIPS ON WOOD HEATING
Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Environmental Protection Agency (EPA), a standard accepted in Canada as well.
EPA-certified wood stoves are different than conventional wood stoves. Burning with an EPA-certified wood stove may therefore require that you modify some of your heating habits. To get the most satisfaction out of your new wood-heating system, please make sure you go through the following check list.
9 The chimney is the engine that drives the wood-heating system. Use a chimney that
is UL-listed, with an inner diameter to match the stove’s outlet collar (6” for all Drolet wood stoves);
9 Try to run the chimney inside the building for as much length as you can. A tall and
warm chimney will produce a good draft;
9 Try to install your chimney straight up and avoid 90 degree turns in the flue pipe and
offsets in the chimney;
9 Make sure that the chimney is tall enough and its top is clear of obstacles so it can
produce a stable draft;
9 Use a chimney thermometer installed at a distance of approximately 18 inches on the
flue pipe above the stove. Flue gases should reach at least 350oF before you close the stove’s primary air intake completely. Operate your unit within the comfort zone indicated on the thermometer;
9 To reduce the risk of smoke spillage into the room upon reloading your stove, leave
the primary air intake completely open for a few minutes. This will heat up the chimney and build up draft before you open the stove door;
9 Maximize hot air circulation! Our wood stoves are designed to easily receive a
variable speed blower that will improve heat distribution in front of the stove;
9 Remember that wood stoves produce radiant heat. Since heat rises, the use of floor
traps will greatly improve the heat transfer to rooms upstairs;
9 Use a mobile home approved stove if you are going to install your wood-heating
system in a mobile home. A fresh air kit must be connected to the stove. Never install your wood stove in a bedroom;
9 Burn only dry cordwood; 9 Make sure you have a good bed of red coals before you load your stove with logs
exceeding 3 inches in diameter;
9 Read and keep you owner’s manual. It will provide you with tips on how to run a
successful wood-heating system.
4
ASSEMBLY
PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION
Figure 1: HT-2000
Pedestal Installation :
1. Remove all bricks and insulations in the appliance.
2. Slowly, lay down the stove on his back.
3. Install legs or the pedestal with the supplied nuts and bolts. Stand up the stove and place it with the required clearances. Note that there is eight holes in the bottom of the stove but only four will align with the pedestal.
4. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws.
5. Slide the ash pan in position
5
BRICKS AND INSULATION INSTALLATION (HT-1600)
1. Remove from the stove all bricks and insulation.
2. Install all side bricks (11 x 4 1/2" x 9" & 1 x 4 ½” x 8 3/16") as shown in drawing below.
3. Install the back bricks (6 x 4 1/2" x 9")
4. Install the bottom bricks (4 x 4 1/2" x 9") + (2 x 6 " x 8") and the ash cap.
5. Install the "T" shape support.
6. Install the baffle bricks (4 x 4 1/2" x 9") + (2 x 3" x 9") on T shape support.
7. Finally, gently slide the insulation panels over the baffle bricks.
Nbr. Description Qty
1 1 ¼” x 4 ½” x 9” 25 2 1 ¼” x 4 ½” x 8 3/16" 1 3 1 ¼” x 6” x 7" 2 4 ASH CAP (SE09224) 1
1 ¼” x 3” x 9"
5 6 ISOLATOR (9 ½" x 12" ) 2 7 SUPPORT (SE09242) 1
2
Figure 2: HT-1600 Refractory Bricks Assembly
6
BRICK AND INSULATION INSTALLATION (HT-2000)
The stove is normally supplied with secondary air tubes in position. To install the baffle bricks and white ceramic insulation, it’s necessary to remove the two front secondary air tubes. First place only one baffle brick and one white ceramic insulation. Use the same method to put the other baffle brick and insulation. Put back in place the secondary air tubes.
Install the yellow insulation and the 6" x 8" or 6" x 6" bricks. Install the side and bottom bricks.
Figure 3: HT-2000 Refractory Bricks Assembly
7
AIR TUBES INSTALLATION (HT-2000):
The secondary air tubes are painted different colours . The back tube is yellow, the middle on is red and the front is unpainted. Before installing, make sure the locating holes in the tubes (holes near one end of the tube) are on the left side. Insert one tube in the right side air channel and slide it to the right as much as possible. Bring the left end of the tube aligned with the ring welded to the left air channel. Move the tube to the left until the locating holes are aligned with those in the ring. Insert a cutter pin to hold in place. The air injection holes should be facing down in the front and middle tubes.
Figure 4: Air Tubes Installation
8
Loading...