GENERAL INFORMATION :
The ULTRA FLAME is a high efficiency fireplace gas insert with an input rating of 30
000 Btu/h with natural gas and 26 000 Btu/h with propane. It features a millivolt valve
with a constant pilot. This lets you choose between a wall mounted switch, a wireless
remote control to turn on or off the main flame at will. This also means that your
ULTRA FLAME gas valve is not connected to any exterior electrical supply and that
your appliance will continue to heat your house in the event of a power failure.
For added efficiency, we included a 140 CFM blower with speed control and thermoswitch. Your fan will therefore turn itself on or off automatically, if you so desire.
The ULTRA FLAME should only installed in a existing masonry or prefab fireplaces.
The installation must be in accordance with local building codes or, if inexistant, with
current CAN/CGA B149.1 & B149.2 , ANSI Z 223.1 installation codes for gas appliance.
The gas insert must be electrically grounded in accordance with the current electrical
Codes.
Read these instructions and consult your local building authorities before installing this
appliance. Install the unit and its venting system only as described in these instructions.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This gas insert has been tested by WARNOCK HERSEY according to the CAN-CGA-
2.22M86 standard, and Z21.50, 50A, 50B American standard.
2
WARNING
* INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.
* DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT.
* HOT WHEN IN OPERATION. KEEP, FURNITURE, CLOTHING AND
FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE.
* ADVISE ADULTS AND CHILDREN TO THE HAZARD OF HIGH SURFACE
TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
* YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE APPLIANCE.
* THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,
DUST, BEDDING MATERIAL, ETC.
* IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS, BURNERS AND
CIRCULATING AIR PASSAGEWAYS BE KEPT CLEAN.
* DO NOT MODIFY THIS APPLIANCE.
* THE LOUVER OPENINGS ON THE GAS INSERT FACE PLATE SHOULD
NEVER BE BLOCKED.
* PROVIDE ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND
PROPER OPERATION.
3
SPECIFICATIONS :
Dimensions :
height : 20”
width : 28”
depth : 15”
face plate : 44 5/16” x 27 1/2”
glass : 14 1/2 x 30 5/16 1400° F clear ceramic
Fuel : Natural Gas Propane
Input : 30 000 26 000 Btu/h
Manifold pressure : 3.5 11 in w.c.
Min inlet pressure : 5 11 in w.c.
Max inlet pressure : 7 14 in w.c.
Vent size : 4” Diam. listed gas liner
Valve : Natural gas Propane
White Rogers Robertshaw
Model 36C03U TYPE 139 Model 7000 MVRLC
Millivolt operated Millivolt operated
SIT SIT
Nova model Nova model
Millivolt operated Millivolt operated
Blower : Variable speed, 140 CFM
Thermo-switch : 120° F “ON” 110° F “OFF” bi-metal type
Efficiency : 74% heating
Clearances to combustibles :
mantel : 10” from top of face place
side wall : 0” from side of face plate
4
TOP, SIDE AND FRONT VIEWS :
5
INSTALLATION :
1. When the masonry fireplace that will receive the ULTRA FLAME gas insert is
thoroughly cold, remove all ashes and vacuum clean.
2. Remove the glass front from the gas insert following page 11 instructions.
3. Remove the burner and firebox bottom plate from the gas insert following page 12
instructions.
4. Remove the draft hood from the top of the appliance.
5. Move the ULTRA FLAME to the desired position and level the appliance using
the two bolts located in the back corners. Mark the location for the gas inlet pipe.
( We suggest using the hole in the back of the ULTRA FLAME for ease of
connection. )
6. Remove the ULTRA FLAME gas insert from the fireplace.
7. Route a 3/8” minimum NPT iron pipe gas line to the desired location.
8. If you wish to make a direct electrical connection to the blower without using the
six foot cord supplied, route a 120 volts, 60 Hz electrical power supply line to the
same location.
9. Remove or block open the masonry fireplace flue damper.
10. Install a certified 4” gas liner inside the chimney from its very top down to the
fireplace.