Mason Air AS8800
Low air loss/Alternating pressure mattress
Instruction Manual
Drive Medical Design & Manufacturing
99 Seaview Boulevard
Port Washington, NY 11050
Toll Free: 877-224-0946
Local: 516-998-4600
www.drivemedical.com
REV2.12.17.13
526001-5150 V1.2
PLEASE READ ALL INSTRUCTIONS BEFORE USE.
Important Safeguards
Introduction
Product Description
Installation
Operation
Cleaning
Storage
Maintenance
………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………..
………………………………………………………………………………………………… ………………… ……
………………………………………………………………………………… …………… ………… …………… …..
……………………………………………………………………………………………………………………………..
……………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………….
Technical Description
Contents
………………………………………………………………………………………………………
………………………………………………………………………………………………………
1
2
3
4
7
9
11
11
12
13
SA VE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical short circuit grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with a grounding plug. The plug must be plugged into an ou tlet that is prop erly
installed and grounded.
DANGER - Improper use of the grounding plug can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat
blade terminal. The wire with insulation having an outer surface that is green with or without yello w
stripes is the grounding wire.
NOTE - If the repair or replacement of the cord is necessary, please contact a qualified electrician or
serviceman. To reduce the risk of electric shock, do not modify the cord or plug in any way.
Check with a qualified electrician or serviceman if the grounding instructions are not completely
understood, or if in doubt as to whether the product is properly grounded.
14
8. TECHNICAL DESCRIPTION
Specifications:
Item
Power Supply (Note: See
rating label on the product)
Fuse Rating T1A, 250V
Cycle time Four selectable
Dimension (L x W x H) 29.1 x 20 x 11.7 (cm) or 11.4" x 7.9" x 4.6"
Weight 2.2 Kg or 5 lb
Temperature
Environment
Humidity
Classification
Mattress
Model 8” Mattress
Dimension (L x W x H)
Weight 7.5 kg or 16.5 lb
NOTE: 1. Consult the distributor or EU representative for further technical documents.
2. The specification is also suitable for other areas operating with same power
supply.
3. Mattress dimension and weight is measured without foam cushion
4. The manufacturer reserves the right to modify the specification without notice.
5. The earthing terminal is served as functional earth, not protective earth. (for UL
only)
AC 120V 50/60 Hz, 0.17A (for 120V system)
AC 230V 50/60 Hz, 0.07A (for 230V system)
Operation:10° C to 40° C (50° F to 104° F)
Storage: -15° C to 50° C (5° F to 122° F)
Shipping: -15° C to 70° C (5° F to 158° F)
Operation: 10% to 90% non-condensing
Storage: 10% to 90% non-condensing
Shipping:10 % to 90% non-condensing
Class II with functional earth (NOTE: 5)*, Type BF, IPX0
Applied Part: Air Mattress
Not suitable for use in the presence of a flammable
anesthetic mixture (No AP or APG protection)
200 x 90 x 20.3 (cm)
or 78.7" x 35.4" x 8"
Specification
Specification
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING
DANGER - To reduce the risk of electrocution:
1. Always unplug this product immediately after using.
2. Do not use while bathing.
3. Do not place or store product where it can fall or be pulled into a tub or sink.
4. Do not place in or drop into water or other liquid.
5. Do not reach for a product that has fallen into water. Unplug immediately.
WARNING - To reduce the risk of burns, electrocution, fire, or injury to persons:
1. This product should never be left unattended when plugged in.
2. Close supervision is necessary when this product is used by, on, or near children or invalids.
3. Use this product only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturer.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the p
and repair.
5. Keep the cord away from heated surfaces.
6. Never block the air openings of this product or place it on a soft surface, such as a bed or couch,
where their openings may be blocked. Keep the air opening free of lint, hair, and other similar
particles.
7. Never drop or insert any object into any opening or hose.
8. Connect this product to a properly grounded outlet only. See Grounding Instructions.
NOTE, CAUTION AND WARNING STATEMENTS:
NOTE - Indicate some tips.
CAUTION - Indicate correct operating or maintenance procedures in order to prevent damage to or
destruction of the equipment or other property.
WARNING - Calls attention to a potential danger that requires correct procedures or practices in order
to prevent personal injury.
SYMBOLS
"BF" symbol, indicate this product is according to the degree of protecting against
for type BF equipment.
Grounding terminal (for 230V system)
Functional earth. (for UL only)
roduct to a service center for examination
electric shock
13
Attention, should read the instructions!
Disposal of Electrical & Electronic Equipment (WEEE):
This product should be handed over to an applicable collection point for the recycling of
electrical and electronic equipment. For more detailed information about the recycling of this
product, please contact your local city office, household waste disposal service or the retail store
where you purchased this product.
Class II (for UL only)
2