IMPORTANT INSTRUCTIONS READ & SAVE

1

TABLE OF CONTENTS

Important Instructions .………………………………….…

3-4

Installation Instructions .……………………….………..… 5-8

Specifications and Wiring Diagram……………………….

9

Parts of the Heater ……………………….……………….. 10

Operating Instructions……………………….………....….

11-13

Maintenance and Cleaning ……………………………….

14

Troubleshooting ……………………………………………

15

2

IMPORTANT INSTRUCTIONS

PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER

NOTE: There may be a trace of smoke or odor when unit is first operated. Don’t be alarmed. This indicates that a drop of oil fell on the heating coil during the manufacturing process. It will quickly evaporate and should not recur.

Make sure that the room in which the appliance is located is well ventilated during this operation. It is normal for the appliance to emit small crackling sounds when you turn it on for the first time. Do not be alarmed.

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, AND INJURY TO PERSONS AND/OR PROPERTY. THESE INCLUDE THE FOLLOWING:

1.Read all instructions before using this heater.

2.This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the heater and away from the sides and rear.

3.Extreme caution is necessary when any heater is used by or near children or the physically challenged and whenever the unit is operating and unattended.

4.Always switch off the heater when not in use.

5.Do not operate any heater after it malfunctions, or has been dropped or damaged in any manner. Disconnect the power at the service panel and have the heater inspected by a certified electrician before use.

6.Do not use outdoors.

7.To disconnect heater, turn off the power to the heater circuit at the main circuit breaker panel.

8.Do not install less than 8 feet (2.4 m) high from the floor and closer than 1 foot (0.3m) to any adjacent vertical surfaces or walls. Keep at least 4.5 inches (0.12m) from the back wall (with or without using the wall hanging mounting bracket).

9.Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may damage the heater and/or cause an electric shock or fire.

3

10.To prevent a possible fire, do not block air intakes or exhaust in any manner.

11.This heater has hot/arcing or sparking parts inside. To reduce the risk of fire, do not use the unit in areas where gasoline, paint, or flammable liquids are used or stored.

12.Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.

13.This product must be installed by a certified electrician, in accordance with local codes.

14.For supply cables, use 8-2 or 8-3 AWG (8.4 mm2) copper wires.

15.This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm flashes, immediately turn the heater OFF and inspect for any objects on or adjacent to the heater that may cause high temperatures. DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING. To reset the heater, switch the CIRCUIT BREAKER OFF and wait five to ten minutes for the unit to cool down before turning the heater back on.

SAVE THESE INSTRUCTIONS

WARNING – RISK OF FIRE, DO NOT USE AS A RESIDENTIAL

OR HOUSEHOLD HEATER.

4

INSTALLATIONINSTRUCTIONS

WARNING: All wiring must be installed by a certified electrician in accordance with electrical safety standards.

The ceiling heater must be grounded in accordance with all national and local building codes.

WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.

All wiring procedures and connections should be in accordance with local codes and ordinances.

NOTE: Compatible with a 240V Line Voltage Double Pole Wall Thermostat. Must be installed by a certified/licensed electrician.

Before installation:

Disconnect the main supply connection.

Supply cables should be 8-2 AWG (8.4 mm2) copper wires. The heater must be connected to an individual branch circuit protected by a 35 amp circuit breaker.

Supply cables must be equipped with a dual pole circuit breaker rating of at least 240V 35 A/pole as the main cut-off switch of power to the heater.

Tools/ Materials Needed (Not Included):

·Regular Screwdriver Set

·Spanner

·Impact Drill with 12mm Drill Bit

Recommended Accessories:

·DR-001: Thermostat

Unpacking Contents:

·Heater

·Heater Handle

·Owner's Manual

·Mounting Bracket

·Warranty Card

·Tilt Adjustable Knob x 2

·Screw Kit

 

5

Loading...
+ 11 hidden pages