DreamLine
For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer
to your model’s web page on DreamLine.com
reserves the right to alter, modify or redesign products at any time without prior notice.
Glass technology.
This is a specially formulated coating
that prevents the buildup of soap and
water spots.
Install the surface with the ClearMaxTM
label towards the inside of the shower.
Please note that depending on the
model, the glass may be coated on
either one or both surfaces.
For best results, squeegee the glass after
each use and dry with a soft cloth.
ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
IMPORTANT INFORMATION
REGARDING THE INSTALLATION
OF THIS SHOWER DOOR
!
Right hand door installation shown as an example
Guide Rail Brackets must be firmly
A
attached to the wall. Installation into a
stud is strongly recommended.
All of the guide rail bracket set
screws must be tightened.
Thread Lock must be applied to both
B
stopper set screws.
Panel-side stopper must be installed
into the pre-drilled stopper hole in
the upper guide rail.
Door-side stopper must be installed
at the proper position to stop the
door from contacting the wall.
C
Roller Wheel Safety Set Screws must
be re-tightened after installation.
Apply thread lock.
Lower Roller wheels must be adjusted
D
during installation to make contact with
the Upper Guide Rail. Tighten Safety set
screws. Apply thread lock.
Bumper Vinyl Seal must be installed on
E
the closing edge of the door glass
The Guide Block must be screwed to the
F
threshold and installed square to the
panel glass and door glass. Installing the
guide block crooked may damage the
bottom edge of the door glass and lead to
breakage.
Bumper is secured in position with 3M
G
tape or screwed to the wall.
PLEASE READ THE ENCLOSED INSTALLATION
MANUAL FOR DETAILS REGARDING PROPER
INSTALLATION.
THE LATEST VERSION OF THE INSTALLATION
MANUAL IS AVAILABLE TO VIEW OR PRINT
ON DREAMLINE.COM
2ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Reinforcement for Enigma Series
Heavy Glass frameless sliding shower door
Install studs OR install 2”x 6” wood blocking between the studs where the
Guide Rail Brackets will attach to the wall
Stud
or
measured
from threshold*
(see list below)
2” X 6”
2” X 6”
threshold
or tub deck
threshold
*Blocking height requirement (to center)
as measured from threshold or tub deck:
Enigma Air = 73” for shower ht / 59” for tub ht
Enigma-X, Enigma-XO = 72-1/2“ for shower ht / 58-1/2” for tub ht
Enigma-Z = 73-1/2” for shower ht / 59-1/2“ for tub ht Enigma = 75-1/2” for shower ht only
3ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Preparation
1. Prior to installation, examine all boxes and packages for shipping damage and compare the piece count
with the packing slip. After opening all boxes and packages read this introduction carefully. Check that all of
the necessary parts are included in the package by checking off the components on the “Detailed Diagram of
Shower Door Components”. If the unit has been damaged, has a finishing defect, or has missing parts, please
contact our customer support department within 3 business days of the delivery date. Please note that
DreamLine® will not replace any damaged products or missing parts free of charge after 3 business
days or if the product has been installed. Contact DreamLine
provide an order number, job name or other proof of purchase to help identify the original order.
®
if you have any questions, and please
2. Please note that you should consult your local building codes with questions on installation
compliance standards. Building and plumbing codes may vary by location, and DreamLine
responsible for code compliance standards for your project and will not accept any returns.
3. If this unit is going to be installed in a new construction, please install all of the required plumbing and
drainage before installing the shower. Use a competent and licensed (if required by local code) plumber for
all plumbing installation
4. Make sure that prior to beginning the installation, the surfaces are leveled and solid and will be able to
support the total weight of the unit. Also make sure the walls are at right angles. Irregular installation surface
level, radius corners or improper angle of side walls will result in serious problems for your installation. Note
that some adjustments and drilling will be necessary during the installation process.
5. Protect all primary surfaces of the product during installation. Never set the glass down directly onto a tile
floor. Leave corner protectors in place until necessary to remove them. Always use a piece of wood or
cardboard to protect the bottom edge and corners of the glass prior to and during installation.
6. This unit must be installed upon a finished threshold and against finished walls.
7. This model does NOT have any adjustment for out of plumb conditions. Verify that your walls are plumb
before proceeding with the installation.
®
is not
8.
This door requires a minimum 2-3/4”of flat threshold space for installation.
9.Note: The installation of this unit requires that you drill down into the threshold.
10.Please note that Step #17 has an option for installing the door-side guide rail bracket to
the wall using anchors. However, the manufacturer strongly recommends installing these
heavy doors to the studs or to pre-installed 2”x 6” wood reinforcements behind the wall in
the area where the guide rail brackets will be attached to the wall.
11. Professional installation required.
Attention: This door is extremely heavy and requires professional installation.
!
!
Two installers recommended.
NOTE: DO NOT attach the handle to the door glass or the towel bar to the panel glass
until instructed. DO NOT use the handle or towel bar to lift the glass during installation.
This may result in damage to the glass and/or serious injury. Always use an assistant or
a professional grade glass suction cup when handling heavy glass.
4ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Tools
Level
Drill bit
(Ø1/8")
(3mm)
Metal File
Tape
Measure
Drill bit
(Ø1/4")
(6mm)(8mm)(10mm)
Professional-grade
Glass suction cup
Drill bit
(D=5/16")
Pencil
Drill bit
(Ø3/8")
Phillips
Screwdriver
Hammer
Miter sawChop saw
or
Silicone
Painter’s
Tape
Hacksaw
Power
Drill
Razor
Knife
Threshold must be level.
!
Tip: Measure the finished opening before
proceeding with the installation to be sure
that the correct model size has been ordered.
Tip:Prior to installation, cover the shower/tub
!
drain with tape to prevent losing screws or
small parts.
!
Tip: Set screw gun clutch to low setting when
!
NOTE: Unpack your unit carefully and inspect it. Lay it out and identify all parts using the detailed
diagram and packing list in this manual as a reference. Before discarding the carton, check for small
hardware bags that may have fallen to the bottom of the box. If any parts are damaged or missing,
please contact DreamLine
your model configuration.
installing screws and bolts to prevent stripping
the heads.
®
for replacement. The shipping boxes may contain extra parts not used in
NOTE: Retain these installation instructions for future reference.
8ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Shower Enclosure Plan
2-3/4” minimum
threshold required
68-3/8” min - 72-3/8" max
32-1/2” or 34 1/2"
When constructing or installing a shower
!
!
base, consider how the thickness of the
wall treatment (wallboard, tile, etc.) will
affect where the shower enclosure will
sit on the threshold.
Compare the overall outside dimensions of
the shower enclosure model size as shown
on the “Shower Enclosure Plan” with the
finished threshold before proceeding with
the installation.
Note: The minimum threshold requirement
for the ENIGMA-XO is 2-3/4” of flat
9ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Installation steps
1. Attach the three Wall Brackets (#19) to the Return Panel
(#27). The bolt side of each Wall Bracket (#19) must face inside the shower. (Fig 1)
Outside
Outside
Fig 1
2. Place the Return Panel (#27) on the pre-installed
shower base or threshold. Position the panel up against
the wall and level it vertically (plumb). Make sure the
Return Panel (#27) is aligned with the shower base or
threshold and will create an opening that is within the
model dimensions of the door section (as measured
from the finished wall to the inside surface of the return
panel glass). (Fig 2)
Return panel placement depends on the
model size purchased:
<48” (SHEN-6132480),(SHEN-6134480) or
<54” (SHEN-6132540),(SHEN-6134540) or
<60” (SHEN-6132600),(SHEN-6134600) or
<72” (SHEN-6132720),(SHEN-6134720)
Outside
<48",<60",<72"
<48",<54”,<60",<72"
See the “Shower Enclosure Plan” on pages 6 and 7 for
dimensions.
10ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
3.Outline the position of the Wall Brackets (#19)
on the wall and the shower base or threshold.
Carefully set the Return Panel (#27) aside.
Remove the Wall Brackets (#19) from the Return Panel (#27). Place the brackets against the outlined
positions and mark the holes on the wall and
threshold for drilling. (Fig 3)
12
34
Fig 3
4. Drill the holes in the wall using a Ø5/16” drill bit and insert the Wall Anchors (#9b) for two of the
Wall Brackets (#19). Mount the Wall Brackets (#19) to the wall using the Round Head Screw
ST4.2×55 (#18). *Drill a hole into the threshold using a Ø1/8” drill bit for an acrylic base
(or Ø5/16” and an anchor for tile) and mount the remaining Wall Bracket (#19) to the threshold using
the
11ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
5.Place the Return Panel (#27) back in the
designated position and assemble the Wall Brackets (#19) onto the glass. Use the provided
gaskets and sleeve to protect the glass. (Fig 5)
6.Measure the distance from the finished wall to the
inside surface of the installed Return Panel Glass (#27). This distance will represent the finished
opening size “W” that will be used to calculate the
finished cut dimension for the Upper Guide Rail
(#03). (Fig 6)
W
Fig 5
7. The Upper Guide Rail (#03) has been precut for the
model width of 48”, 60” or 72”. (Note: The actual rail is
shorter than the model width by design).
Cut the Upper Guide Rail (#03) from the door end only,
which is the end that is farther from the Glass Bracket (#07)
holes. (Fig 7)
The length to cut off will be (L):
Model Width – opening W = cut off length (L)
FOR EXAMPLE ONLY:
If the model width is 60” and the finished opening from the
finished wall to the inside surface of the installed Return Panel Glass (#27) is 58”, then you will need to cut 2” off
from the door end of the Guide Rail.
Example: 60” – 58” = 2” cut off
W
Fig 6
glass bracket
holes
door end
door end
*Note that this is only an example and the actual cut-off
length will vary based on the actual finished opening
dimension.
12ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
X
8a.Attach the Upper Guide Rail (#03) to the Stationary Glass (#02) with the Glass Brackets (#07) and
tighten the bolts into the predrilled holes in the Upper Guide Rail (#03). Make sure both adjustment
disks are installed in the same direction with the high spot towards the door end. (see *Note below)
Make sure that the guide rail is attached parallel to the top edge of the stationary panel glass. (Fig 8.3)
*NOTE:The outer glass bracket disk has
an eccentric bushing for adjustment.
Be sure to install both glass bracket disks
with the high spot of the bushing pointed
towards the door end of the guide rail.
TIP: Mark the location of the high spot on the outer
surface of the adjustment disk with an erasable felt
tip pen to make adjustment easier to see.
High spot of disk bushing
Door end of guide rail
8b.Slide the Door Stoppers (#01) onto each end of the Upper Guide Rail (#03) and secure them
using the 4mm Allen Wrench (#11). Install the panel-end stopper into the pre-drilled stopper hole in the Upper Guide Rail (#03) and apply Thread Lock (#26) to the set screw. Attach the
door-end stopper approximately 4” from the other end of the guide rail. (The door-end stopper
position will be adjusted in a later step after the door glass is installed). (Fig 8)
glass bracket
disk
panel end
1
outside
4
Door end
of Guide
Rail
not used in this
configuration
see step# 9
2
5
stopper hole
outside
Fig 8
3
thread lock
6
outside
8c.Slide the Guide Rail Brackets (#08) onto each end of the Upper Guide Rail (#03) and secure them.
Next, assemble the Wall Bracket (#19) onto the bottom corner of the Stationary Glass (#02) with the
bolt facing into the shower as shown in Fig 8.5. Use the supplied gaskets to protect the glass. (Fig 8)
13ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
X
9.Place the Stationary Glass (#02) with the Upper Guide Rail (#03) onto the threshold and position it
against the wall. Fasten the Upper Guide Rail (#03) to the Return Panel (#27) using the Glass
Connector (#28). (Fig 9a)
Tighten the set screws to secure the guide rail bracket sleeve to the Glass Connector (#28). (Fig 9a)
Make sure the Stationary Glass (#02) and the Upper Guide Rail (#03) are level. If a horizontal
adjustment is required; loosen, rotate and re-tighten the disks on the Glass Brackets (#07) and/or the
Glass Connector (#28). (Fig 9b)
123
sleeve
Glass Connector (#28)
not used in this
configuration
Fig 9a
Glass Bracket adjustment
rotate disk(s) to level rail
Lower guide railRaise guide rail
Glass Bracket adjustments
rotate disk to level rail
Fig 9b
!
Note: When installing the 72” model, proceed to Step #10.
When installing the 48”or 60” model, skip to Step #13 to continue
with the installation.
14ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
ATTENTION: This step shows the Small Stationary Glass Bracket (#21) installation for the
72” model only (not included with the 48“ or 60” model).
(Fig 10)
10. If the model width is 72” and includes the
Small Stationary Glass (#23), attach the Small
Stationary Glass Bracket (#21) to the Upper Guide Rail
for 72” (#24) between the Door Stopper (#01) and the
Guide Rail Bracket (#08) as shown in Fig 10.
This bracket will be repositioned during the installation
of the Small Stationary Glass (#23). (Fig 10)
disk
Fig 10
ATTENTION: This step shows the Small Stationary Glass (#23) installation for the 72” model
only (not included with the 48“ or 60” model).
11. If the model width is 72” and includes the Small Stationary Glass
(#23), assemble the Wall Bracket (#19) onto the larger notch at the
bottom corner of the SmallStationary Glass (#23). Use the provided
gaskets to protect the glass. (Fig 11)
15ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
12.If installing the 72” model:
Unscrew the disk from the Small Stationary Glass Bracket (#21) and loosen the set screw that secures
the bracket to the guide rail. If necessary, slide the Door Stopper (#01) away from the area so that it will
not interfere with the placement of the Small Stationary Glass (#23). (Fig 12.2)
Position the Small Stationary Glass (#23) onto the threshold and carefully butt it up against the installed
Return Panel Glass (#27). Align the Small Stationary Glass Bracket (#21) with the hole in theSmall
Stationary Glass (#23). Reattach the outer disk and secure the Small Stationary Glass Bracket (#21) to
the Upper Guide Rail for 72” (#24). (Fig 12)
1
2
3
4
Fig 12
13. Once the Upper Guide Rail (#03) or Upper Guide Rail (for 72”) (#24) is level, mark the position
of the Guide Rail Bracket (#08) and the Wall Bracket (#19) on the wall. (Fig 13a)
*NOTE:
for the Small Stationary Panel Glass (#23). (Fig 13b.3*)
If installing the 72” model, also mark the position of the Wall Bracket (#19) on the threshold
16ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
14.Make sure the Stationary Glass (#02) is parallel to the front edge of the threshold. Level it vertically
(plumb) and mark the position on the threshold. Slide the Guide Block (#12) into the notch in the
Stationary Glass (#02), and align flush with the edge. Mark its position and also mark the hole for
drilling using a pencil (or center punch). (Fig 14a)
Note:If installing the 72” model, also position the Small Stationary Glass Bottom Bracket (#22) with
the edge of the Small Stationary Glass (#23) and mark its position and the hole for drilling. (Fig 14b)
Fig 14a
Fig 14b
15. After marking the positions of all the hardware, set
the Stationary Glass (#02) with the Upper Guide Rail
(#03) aside. (If installing the 72” model, also remove the
Small Stationary Glass (#23) from the Upper Guide Rail
(#03). Remove the Guide Rail Brackets (#08) from the
Upper Guide Rail (#03) and the Wall Bracket (#19) from
the Stationary Glass (#02). Place the Wall Bracket (#19)
and one Guide Rail Bracket (#08) back to the outlined
positions on the wall and mark the holes for drilling.
*NOTE:If installing the 72” model, perform the same
procedure to mark the hole for the Wall Bracket (#19) on
the threshold for the Small Stationary Panel Glass (#23).
(Fig 15.3)
12
3*
Fig 15
base
sleeve
Separate the Guide Rail Bracket (#08) base from the sleeve by loosening
the set screws. Leave the sleeves on both ends of the upper guide rail.
17ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
16. Drill a hole for the Wall Bracket (#19) using a Ø5/16”
(8mm) drill bit and insert the Wall Anchor (#9b).
(Fig 16.1 and 16.2)
*For the 72“ model, drill an Ø1/8” hole for an acrylic base (or Ø5/16” for tile) for the Wall Bracket (#19) for the Small
Stationary Panel Glass (#23). (Fig 16.5)
Drill the holes for the Guide Rail Brackets (#08) using a
Ø3/8” (10mm) drill bit and insert the Wall Anchors (#9a).
(Fig 16.3**-16.4**)
!
**NOTE: Step #16 has an option for installing the guide rail brackets to the wall using anchors. However, the
manufacturer strongly recommends installing these
heavy doors to the studs or to pre-installed 2”x 6”
wood reinforcement behind the wall in the area where
the guide rail brackets will be attached to the wall.
1
3**
for 72” model
5*
Ø5/16”
(8mm)
Ø3/8”
(10mm)
see Note**
2
4**
**For the recommended installation into a stud,
drill a Ø1/4” hole up to the stud, do not use wall
anchors, and let the screw bore into the wood.
(Fig 16)
Ø1/8”
(8mm)
see Note*
Fig 16
17. Fasten the Wall Bracket (#19) to the wall using the ST4.2×55 Truss Head Screw (#18). (Fig 17.1)
For the 72“ model, repeat this step to attach the Wall Bracket (#19) for the Small Stationary Panel
Glass (#23). Use an ST4.2x25 screw into an acrylic base or ST4.2x40 with an anchor for tile (Fig 17.5).
Attach the base part of one Guide Rail Bracket (#08) to the wall using the ST6×65 Large Truss Head
Screw (#10) (Fig 17.2). Note that the adjustment set screws on the bracket must be aligned verticallyfor easier access to tighten and adjust for level after the glass is installed. Fasten the Upper Guide
Rail (#03) to the Return Panel (#27), connecting the sleeve of the Guide Rail Bracket (#08) to the
Glass Connector (#28) (Fig 17.3 and 17.4). Align the set screws vertically and tighten. (Fig 17)
19ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
19. If installing the 72” model, repeat Step #18 for the Small
Stationary Glass Bottom Bracket (#22). Loosen the set screw
and remove the guide block face plate.
use a pencil or a
12
center-punch to
mark the hole
*NOTE:
◾For installation into an Acrylic Threshold:
drill an Ø1/8”(3mm) hole and use the ST4.2 x 40mm
Countersunk Screw (#17)
OR
◾For installation into a Tile Threshold:
drill a Ø5/16”(8mm) hole and use the ST4.2 x 40mm
Countersunk Screw (#17) (with Wall Anchor (#09b) for
tile)
Apply silicone to the underside of the Stationary Glass
Bottom Bracket (#22) and screw the Stationary Glass
Bottom Bracket (#22) to the threshold. (Fig 19)
NOTE: The Small Stationary Glass Bottom Bracket (#22)
screwed down to the threshold.
ST4.2 X 40
**use anchor with
34
tile threshold
5
*see note
Fig 19
M5 X 10
Part#22 - Small stationary Glass Bottom Bracket for 72” model only
NOTE: Before you install the Stationary Glass (#02),
take the Door Glass (#05) into the shower area and
!
lean it against the wall with the handle holes on the
correct side. After the Stationary Glass (#02) is installed, it
may not be possible to easily get the door glass into the
shower or to turn it around. Always use padding to protect
the glass and shower surfaces.
NOTE: DO NOT attach the handle to the door glass
!
until instructed to do so. DO NOT attempt to lift the
door glass with the handle as this may result in
damage to the glass and/or serious personal injury.
Use a professional grade glass suction cup and an
assistant.
20ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
20. Reposition the Stationary Glass (#02) and Upper Guide
Rail (#03) onto the threshold and fasten the sleeves of the
Guide Rail Brackets (#08) to the installed bracket on the wall
and the Glass Connector (#28).
Tighten the set screws on the Guide Rail Brackets (#08) to
secure the Upper Guide Rail (#03). Position the bracket set
screws so that they are accessible from the top and bottom.
(Fig 20.1 and Fig 20.2)
1
2
Assemble the Wall Bracket (#19) at the bottom corner of the
Stationary Glass (#02). Use the clear vinyl gasket between
the glass and the metal parts to avoid contact with the glass,
then tighten the bolt with the supplied allen wrench. (Fig 20)
TIP: Adjust the installed Upper Guide Rail (#03) to level
as necessary using the Guide Rail Brackets(#08) first
and then the Glass Brackets (#07). Start adjustments
from the door end. (Fig 21 and Fig 22)
Panel end
Glass bracket
(Right hand door installation shown as example)
3
Fig 20
outside
Door end
Guide Rail Bracket
or Glass Connector
Fig 21
NOTE: Use the Guide Rail Bracket (#08) set
screws and/or the Glass Connector (#28) to
adjust the Guide Rail (#03) to level.
Fig 22
To lower the rail using the
Guide Rail Bracket:
Loosen the top set screw and
tighten the bottom set screw.
To raise the rail:
Loosen the bottom set screw
and tighten the top set screw.
To raise or lower the rail
using the Glass Connector:
Loosen the bolt and rotate
the disk then tighten the
bolt.
21ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
21a.For the 48” or 60“ model size: Measure the
distance from the edge of the Guide Block (#12)
to the wall. This distance will be “X”. Cut the
Anti-Splash Guard (#15) to the size of:
(X) + 3/8”. (Fig 23a)
21b.For the 72” model size:Measure the
distance between the edge of the Guide
Block (#12) to the edge of the Small
Stationary Glass Bottom Bracket (#22). This
distance will be “L”.
Cut the Anti-Splash Guard (#15) to the size of:
(L) + 3/4”. (Fig 23b)
for 48”or 60“
model
X
X + 3/8”
measure the distance ‘X’ from the guide block to the
wall and add 3/8”
for 72” model
L
L + 3/4”
measure the distance ‘L’ between the guide blocks
and add 3/4”
Fig 23aFig 23b
22. Apply silicone to the bottom of the Anti-Splash Threshold (#15). Insert one end of the
Anti-Splash Threshold (#15) into the Guide Block (#12). Align the Anti-Splash Threshold (#15)
parallel with the front edge of the shower base or threshold.
Cover the other end of the Anti-Splash Threshold (#15) with the ThresholdCap (#16) against the
wall with a spot of silicone. (48” or 60” model) (Fig 24.4)
For the 72” model: Insert the Anti-Splash Threshold (#15) into the Small Stationary Glass
Bottom Bracket (#22). Add a spot of silicone inside the guide block. (Fig 24.5*)
23ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
25.If installing the 72” model: Apply a thin bead of silicone to the edge
of the Small Stationary Panel Glass (#23) and carefully butt it up against
the installed Return Panel Glass (#27). Attach the Small Stationary Panel
Glass (#23) to the Upper Guide Rail (#03) using the Small Stationary
Glass Bracket (#21).
Attach the face plate to the Wall Bracket (#19) on the threshold.
Use some painter’s tape to secure the corner until the silicone cures.
(Fig 27 and Fig 28)
1
4
2
5
3
Fig 27
outside
26. Attach the Guide block face plate to the installed
Small Stationary Glass Bottom Bracket (#22) and
tighten the set screw with the supplied allen wrench.
Make sure that the clear gaskets are in place to protect
the glass. Use the supplied Decorative caps to cover the
screw holes. (Fig 28)
24ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
NOTE: DO NOT attach the handle to the door glass until instructed to do so.
!
DO NOT attempt to lift the door glass with the handle as this may result in damage to the glass
and/or serious personal injury.
27.Attach the two Rollers (#04) to the Door Glass (#05) with the wheelsfacing the outside of the
shower. Align the safety set screw towards the top for easier access (See Fig 29 and page 30 for
details).
Lift the door and position the Rollers (#04) onto the Upper Guide Rail (#03) while carefully sliding
the bottom edge of the Door Glass (#05) into the groove of the Guide Block (#12).
If necessary, adjust the disks on both Rollers (#04) to ensure that the bottom edge of the Door Glass
(#05) does not touch the Guide Block (#12) and the bulb vinyl seal meets evenly with the wall.
(see details on page 32). (Fig 29)
Note: The adjustment disks in
the wheels are the same as the
disks in the Glass brackets and
can be rotated to adjust the
door glass to create a seal with
the wall. See detailed
description on page 32.
!
TIP: Mark the location of the
high spot on the outer surface of the
adjustment disk with a felt tip pen to
make adjustment easier to see.
TIP: Use a 3/16” shim
beneath the door glass when
adjusting the level of the
door so that the glass does
not make contact with the
guide block.
25ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
28.Attach the two remaining Rollers (#04) into the holes
in the Door Glass (#05) beneath the Upper Guide Rail
(#03). Adjust these Rollers (#04) to make contact with the
Upper Guide Rail (#03). Apply Thread Lock Adhesive
(#26) to the bolts and safety set screws. Align the safety
set screw towards the bottom(Fig 30.4) for easier access to
retighten after installation. (Fig 30)
12
Upper Guide Rail
front view
side view
!
3
4
safety set screw
Fig 30
NOTE: The Safety set screw on both wheels MUST BE
re-tightened after installation to prevent the large bolt
from coming loose. Apply thread lock during installation.
(See details in Fig 30 and Fig 31 and also on Page 33)
26ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
29.Press the Anti-Water Strip (#14) onto the vertical edge
of the Stationary Glass (#02) and the Door Glass (#05)(Fig 24.1). Press the Bumper Strip (#13) onto the vertical
edge of the Door Glass (#05) (48” and 60“ model). (Fig 32.2)
For the 72” model: Attach Anti-Water Strip (#14) to the
edge of the Small Stationary Glass (#23). The Bumper Strip (#13) is not necessary with the 72” model (Fig 33.3*).
1
inline panel
inside
door
2
door
48”or 60”
model
wall
72” model
Attach the Handle (#06) to the Door Glass (#05). (Fig 32)
Note: Use a razor knife to trim the Anti-Water Strip (#14) at
the top to avoid interfering with the lower Rollers (#04).
(Right-hand door installation shown as an example)
30. Position the Door Stoppers (#01) and screw them tightly to the Upper Guide Rail (#03).
!
NOTE: The Door Stoppers (#01) must be positioned correctly to prevent the handle from
contacting the Stationary Glass (#02) (48”, 60” & 72“ models) and to stop the Door Glass (#05) in a
position that allows the bumper strip to create a seal with the wall, but does not allow the door glass to
bang into the wall during normal operation (48” & 60” models). (Fig33a and Fig 33b)
*For the 72” model: Install the door-side stopper in a position to prevent the handle from making
contact with the small inline panel glass when the door is in the closed position. (Fig33b.7)
28ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
31.Toinstall the Bumper (#30) with the 3M tape: position the Bumper (#30) onto the threshold
and against the wall on the stationary panel side of the installation. (For 72” model, this will be the
side of the opening with the large stationary panel) Remove the 3M Tape and position the Bumper
(#30) onto the thresholdagainst the Wall Bracket (#19).(Fig 34)
NOTE:The surfaces need to be clean and free of
construction debris before installing the bumper.
!
Wipe the area with an alcohol swab before
installation
Door
Panel
TIP: Install the Bumper (#30)using the
3M tape. Screwing the bumper to the wall
using a Ø5/16” hole and anchor is
optional (see step 32).
The Bumper (#30) is reversible for
Left or Right wall installation.
(Left wall installation shown below from
inside the shower)
29ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
32.Toinstall the Bumper (#30) with the screw method: position the Bumper (#30) onto the threshold
and against the wall on the stationary panel side of the installation. (For 72” model, this will be the side
of the opening with the large stationary panel). and mark the position of the hole onto the wall. Drill a
Ø5/16” hole and insert the wall anchor. Remove the 3M Tape and position the Bumper (#30) onto the
threshold against the Wall Bracket (#19) and attach using the ST4.2 x 40 Countersunk screw.
(Fig 35)
NOTE:
The surfaces need to be clean and free of
construction debris before installing the bumper.
Wipe the area with an alcohol swab before installation
Door
Panel
NOTE: Use caution if using the screw
method to not crack the wall/tile and to
avoid any plumbing behind the wall.
The Bumper (#30) is reversible for
Left or Right wall installation.
(Left wall installation shown below from
inside the shower)
12
34
3M TAPE
4a
Inside
Extender driver bit recommended
for screw installation method
31ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Roller adjustment procedure for Enigma, Enigma-X and Enigma-XO
The bushing that goes through
Insert a small tool (like an
you reghten the big bolt.
Once you have loosened the
This is the adjustment disk.
2
3
4 4a
To achieve minimal clearance beneath the door glass without making contact with the boom
guide block and creang a good seal with the wall.
Have at least two 3/16” shims or wedge shims (to maintain space beneath the door glass) and an assistant
available to help with this procedure.
Adjust only one wheel at a me and you may need to perform these steps more than once to
get the desired results.
Cauon: The door glass is heavy and may require two people to safely accomplish these steps.
1. the -X) orFirst, loosen and lower either Roller Guards (Enigma Boom Rollers (Enigma, Enigma-XO) to allow
enough room to adjust the upper rollers. (If you have not installed these yet, you will be instructed to in
step #7 aer these adjustments are made)
2. Loosen the safety set screw on the roller. (See note 2 below)
3. Loos
en the big bolt just enough so that you can rotate the adjustment disk. (See note 3 below)
4. Rotate the adjustment disk to raise or lower the door slightly with help from an assistant. You can use a
small tool (like an allen wrench) to aid in turning this disk by inserng it into the small hole on the edge of
the adjustment disk. (see note 4 & 4a below)
5. While holding the adjustment disk in p
lace, reghten the big bolt. Use a shim or have an assistant hold
the door glass in place while you reghten the big bolt.
6. Re-ghten the safety set screw to hold the big bolt in place (see note 5). Test the operaon of the door.
7. For the Enigma-X:Reposion the rollerguards approximately 1/16” beneath the guide rail and
reghten. For the Enigma/Enigma-XO: adjust the lower rollers to make contact with the rail in the same
manner as th
Loosen this safety set screw
first. This holds the big
bolt in place and must
be re-ghtened aer
the roller is adjusted.
Posion this set screw at
the top for easier access.
5
It is extremely important
that the safety set screw
is re-tightened to secure
the big bolt.
e upper rollers.
During installaon onto the glass,
rotate this disk so that the safety set
screw is at the top for easier access
set screw, you will be able to
loosen this big bolt just
enough to allow you to
rotate the adjustment disk.
Once the big bolt is loosened,
rotate this disk to raise or
lower the door glass slightly.
Use cauon so that the door
glass does not make contact
with the guide block.
!
add threadlock to
the safety set screw
and wheel bolt
the glass is ellipcal and
allows you to raise or lower
the glass when you rotate the
adjustment disk.
allen wrench) into this hole
to help rotate this
adjustment disk and also to
hold the disk in place when
32ENIGMA-XO Shower Enclosure manual Ver 1 Rev 1 01/2018
Product Maintenance
BASES and BACKWALLS: To ensure long lasting life for your acrylic back walls: wipe them off
after each use with a soft cloth. To clean the acrylic back walls use non-abrasive sprays or cream
based cleaners. Avoid the use of aerosol spray cleaners. Never use abrasive cleansers, metal
brushes or scrapers that could scratch or dull the surface.
GLASS: To ensure long lasting life for your glass shower products: wipe them off after each use
with a soft cloth. Rinse and wipe off the glass using either a soft cloth or a squeegee to prevent
soap buildup and water spots (Hard water can etch the surface of the glass over time if left to
dry). To prevent scratching the surface: never use abrasive cleaners or cleaning products that
contain scouring agents. Never use bristle brushes or abrasive sponges that may scratch the
surface.
HARDWARE: To ensure a long lasting finish: wipe off the metal parts after each use with a soft
cloth. Do not use abrasive cleaners or cleaning products containing ammonia, bleach or acid. If
accidentally used, rinse the surface as soon as possible to prevent damage to the finish (peeling
or corrosion). After cleaning the polished finishes, rinse thoroughly and wipe dry with soft cloth.
Clean stainless steel surfaces at least once a week. When applying stainless steel cleaner or
polish to stainless steel hardware, work with (not across) the grain. Never use an abrasive
sponge or cloth, steel wool or wired brush as these may permanently scratch the surfaces.
NOTE: To maximize the life of your door, it is important to regularly inspect
the glass and other hardware for misalignment, proper attachment, and/or
damage. Contact DreamLine
®
with any questions or concerns.
Enigma-XO Maintenance checklist
◻ Guide rail level and tight
◻ Guide rail brackets tight to the walls
o All set screws tight
◻ Inline and Return Panel glass secure
◻ Panel glass brackets tight
◻ Guide block square to the threshold and glass
◻ Proper clearance beneath the door glass between the threshold and within the guide block
◻ Door Glass adjusted so that the Bulb vinyl seal makes even contact with the return panel glass
◻ Wheel assemblies tight
o Wheel roller bolts tight on all four wheels
o Wheel assembly safety set screws tight and accessible on all four wheels
◻Stoppers tight and positioned correctly
o Panel-side stopper installed into the pre-drilled hole in the guide railo Adequate Handle clearance when the door is fully open
o Door-side stopper positioned at approximately 3” (+/- 1/8”) (as measured from the
return panel glass to the center of the stopper)
◻ Stopper stops the door and bulb vinyl seals to the return panel glass
◻ SafeStop bumper secure to the wall
◻ Remove vinyl seals to inspect the edges of the door glass for concealed damage
o Damaged glass must be replaced!◻ Replace damaged or missing vinyl seals