DreamLine
without prior notice. For the latest up-to-date technical drawings, manuals or any
TM
reserves the right to alter, modify or redesign products at any time
other details please refer to the support.BathAuthority.com
web page.
Please carefully read the instructions before installing. If you have any questions
regarding installation, please call our technical support specialists Monday through
Friday 9:00 AM – 5:00 PM EST at 1-866-731-8378, ext. 3 or e-mail our technical support
group at
For more information on DreamLineTM Tub Back Wallplease visit www.BathAuthority.com
Rev 1.1
support@BathAuthority.com.
1
Preparation
1. After opening all boxes and packages, read this introduction carefully. Check that all of
the needed parts are included in the package, by marking all the components on the
“Detailed Diagram of Tub Back Wall Components”. Examine boxes and packages for
shipping damage. If the unit has been damaged, has a finishing defect, or has missing
parts, please contact our customer support department within 3 business days of the
delivery date. Please note that DreamLine TM will not replace any damaged products or
missing parts free of charge after 3 business days or if the product has been
installed. Feel free to contact DreamLineTM if you have any questions.
2. Please note that you should consult your local building codes with questions on
installation compliance standards. Building and plumbing codes may vary by
location, and DreamLine is not responsible for code compliance standards for your
project.
3. This acrylic wall system is specially designed to be installed over any solid surface. If you
are installing the acrylic walls over the existing tiles, remove all loose tiles before the
installation. If you are installing over the existing painted walls, take all loose paint off.
Please, note that some cutting and drilling might be necessary during the installation
process.
4. Make sure to turn off the water supply, remove faucet, handles or any fixture trims
protruding from the wall. Clean the surface removing soap film and dirt from all wall
surfaces using regular household detergent, then wipe it dry.
Caulk
Level
Tools Required
Tape
MeasurePencil
Caulk
Gun
Electric
Drill
Knife
Drill bit
(Ø 5/16")
Hammer
T-Square
Phillips
Screwdriver
Rev 1.1
2
Detailed Diagram of Tub Back Wall Components
4
6
7
8
9
10
3
1
2
5
Packing List
01 Side panel 2pcs 06 Wall anchor 21pcs
02 Back panel 2pcs 07 Countersunk screw ST4.2×30 21pcs
NOTE: Unpack your unit carefully and inspect it. Lay it out and identify all parts using the
detailed diagram and packing list in your manual as a reference. Before discarding the carton,
check for small hardware bags that tend to fall to the bottom of the box. If any parts are
damaged or missing, please contact DreamLineTM for replacement.
Rev 1.1
3
Back Panel Installation Instruction
1. Measure the distance of the back wall
of the tub (corner to corner)
The distance is “W”
See Fig. 1 for details.
W
2.Divide the W measurement by 2
(W/2). Place a mark on the back wall
and draw a vertical line from top to
bottom.
See Fig. 2 for details.
Fig. 1
W/2
W/2
Rev 1.1
Fig. 2
4
3. Measure the side walls from the
corner to the front point where the
Side panel (01) is going to end.
This distance is “D”.
See Fig. 3 for details.
D
D
4. Verify on which side of your tub
wall the fixtures will be installed.
Place a mark on the side wall (NB: not the side panel!) with a
distance of 1” (one inch) from the
corner and draw a vertical line from
top to bottom.
Take the exact measurements:
• from the fixture to the line:
(A, B, C)
• from the fixture to the bottom:
(E, F).
See Fig. 4 and Fig. 5 for details.
E
”
F
A
Fig. 3
D - 1”
C B
D
Trim line
Rev 1.1
Fig. 4
5
Attach the Center cover (05)
5.
vertically at the center point
Fig. 5
3
along the line and mark the
drilling holes through the
Ø5/16”
predrilled holes on the Center
cover.
Drill the holes using Ø5/16” drill
bit and insert the Wall Anchors (06).
See Fig. 6 and Fig. 7 for details.
2
4
Rev 1.1
Fig. 6
6
6. Attach the Corner cover (04)
to the corner of the wall and
mark the drilling holes
through the predrilled holes
on the Corner cover.
Drill the holes using Ø5/16”
drill bit and insert the Wall Anchors (06).
See Fig. 8 and Fig. 9 for
details
1
2
Fig. 7
3
Ø5/16”
4
Rev 1.1
Fig. 8
7
7.Determine the position of both Back
panels (02).
NOTE:
a) Narrow side of the Back panel
cannot be trimmed and should
face the center of the Back wall.
b) Wide side of the Back panel can
be trimmed to the size of the wall
and should face the corner.
Place a mark on the wide side of the
Back panel with a distance of
(W/2 – 1”) from the center edge of
the Back panel to the wide side of
the Back panel and draw a straight
line from top to bottom.
See Fig. 10 for details.
Fig. 9
W/2-1”
W/2-1”
a
b
b
Rev 1.1
Fig. 10
8
Loading...
+ 16 hidden pages