Draper Premier Installation & Operating Instructions Manual

Page 1
Installation/Operating Instructions
Targa and Premier 220V Electric Projection Screen—Large Sizes by Draper
These Installation/Operating Instructions are available in the offi cial language of the country where you purchase the product. Please contact your distributor to request a copy. Vous pourriez demander les instructions d’installation et d’opération traduises dans la langue offi cielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur. Die Gebrauchsanweisung für Installation und Konstruktion sind in der offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.
Before fully operating screen: On Large Targa, remove tape; on Large Premier, lower viewing surface enough to fully expose shipping brackets, then remove shipping brackets by loosening screws, removing end shipping brackets, sliding center shipping brackets off dowel, and re-tightening screws (see diagram).
Caution
Read instructions through completely before proceeding. Follow instructions carefully. Installation con trary to instructions in val i dates war-
ranty.
aged or should other ser vice be required.
Screen should be installed level (using a carpenter’s level). The case must also
be installed so that the top of the case is level (front-to-back) to prevent the fabric from contacting the case housing.
Nothing should be fastened to screen dowel or viewing surface. Operating switch(es) packed separately in screen carton. Do not dis card with
packing material.
Screen operates on 220V AC, 50 Hz., 1 ph. current.
NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any re spon si bil i ty on the part of Draper, Inc. for improper in stal la tion or faulty work man ship at the jobsite.
Hanging Screen
General:
Screen should be lifted into position only by the end mounting brackets. Never attempt to lift screen along its length. Installer must also insure that wall or ceiling structure is of adequate strength. Supporting hardware must be essentially vertical. Do not suspend this product using chain or cable (see note at bottom right regarding this screen with Tork Star). The screen must be securely fastened using at least two of the mounting holes provided in each of the case mounting brackets.
When locating view ing surface and checking clear ance for screen’s op er a tion, remember surface is centered in case. Handle case care ful ly to protect its fi nish. Regardless of mounting method, screen should be positively and securely sup port ed so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall. Installer must insure that fas ten ers used are of adequate strength and suit able for the mounting sur face cho sen.
Ceiling Installation:
Product is very heavy: Installer must provide adequate attachment hardware and anchors as required. Installer must also insure that ceiling structure is of adequate strength.
Wall Installation:
Product is very heavy: Installer must provide adequate attachment hardware and anchors as required. Installer must also insure that wall structure is of adequate strength.
Caution: Do not remove the roller as­sembly from the case unless necessary for repairs. If the roller assembly is removed, be sure motor is fully re-seated in the bracket, and re-secure it carefully with the motor retaining spring and screw (see diagram below).
Screw is included with Large Targas and Large Premiers.
Please note: Do not use a power screwdriver to tighten screw. Maximum torque for tightening screw is 5 lb-inches.
Electrical Connections
Screen operates on 220V AC, 50 Hz., 1 ph. current. Junction box is located inside left endcap and cover plate is secured to endcap with two screws. Junction box contains terminal strip, per wiring diagram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with wiring diagram supplied, and wiring should comply with na tion al and local electrical codes. All operating switches should be “Off” before power is con nect ed.
®
220V AC Single Station Control—3-position up-off-down switch per mits op er a tion to be stopped at any point. Factory adjusted limit switches au to mat i cal ly stop screen when fully down or fully up. 220V AC Multiple Station Control—Switches are sim i lar in ap pear ance to 220V Single Station Control. Screen stops when switch is re leased and may be re start ed in either direction. Factory adjusted limit switch es stop screen automatically when fully up or fully down. 24V Control—Three-button up-stop-down switch(es) stop at any point de sired, operate in any sequence. Factory adjusted limit switches au to mat i cal ly stop screen when fully up or fully down. Installer should incorporate an all-pole disconnect in the fi xed wiring. Key Operated Switching—Two kinds of key-op er at ed switches are op tion al ly available with this unit. The key-operated power sup ply switch controls power to the screen and switch es. When it is “off ”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. A three-po si tion key switch per mits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote.
Screen has been factory set and should not nor mal ly require further ad just ment. How­ever, if you desire to change the “up” and “down” stop ping po si tions, proceed as follows:
CAUTION: Be sure all switches are in “off ” position before ad just ing limit switches. Always be pre pared to shut screen off man u al ly when new adjust- ment is being tested. Screen may be se vere ly dam aged if viewing surface is al lowed to run too far up or too far down. Adjusting “fully up” position — “Up” stopping position may be ad just ed by turning the yellow limit switch adjustment socket. The yellow socket is lo cat ed on left end of screen roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turn ing the socket coun ter clock wise will allow the view ing surface to retract farther into the case. Turn ing it clockwise will cause the sur face to stop farther out of the case. One full revolution of the socket will alter the stop ping position of the view ing surface by ap prox i mate ly 1½". Adjusting “fully down” position — “Down” stopping position may be adjusted by turn­ing the white limit switch adjustment socket. The white socket is located on the left end of screen roller and is accessible to a screw driv er/Allen wrench (4mm or 5/32"). Turning the socket coun ter clock wise will allow the viewing surface to run farther down. Turning it clockwise will shorten the viewing surface, causing it to stop in a less extended po si tion. At no time should viewing surface be unrolled enough to expose any part of screen roller.
16.8 cm
Use of Large Case Targa or Large Case Premier screens with TorkStar Utility Li­neset requires specially modifi ed Large Premier or Large Targa case and mount­ing brackets. DO NOT use TorkStar with standard Large Case Targa or Premier screen and brackets. Contact Draper for details.
16.8 cm
Targa Premier
Operation
Adjustments
16.8 cm
16.8 cm
IMPORTANT
Copyright © 2009 Draper Inc. Form 220VTarga-LargeSizes_Inst09-R2 Printed in U.S.A.
If you encounter any diffi culties installing or ser vic ing your large size Targa or Premier screen, call your dealer or Draper Inc., Spiceland, Indiana, USA, (765) 987-7999 or fax (765) 987-1689.
Page 2
220V Targa and Premier —Large Sizes by Draper
9
Case Dimensions
Types of Installation
Wall Mounted
Appropriate hardware provided by installer.
Product is very heavy: Installer must provide adequate attachment hardware and anchors as required. Installer must also insure that wall or ceiling structure is of adequate strength.
Ceiling Mounted
Appropriate hardware provided by installer.
Tab-Tension Adjustment
Procedure for Premier
Determine which side requires adjustment. Secure dowel with one hand.
Caution: Do not touch or bend surface.
Using Philips-head screwdriver, depress spring-loaded adjustment screw (see drawing) and slowly turn clockwise to tighten tension, or
Dowel
counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. If problem still is not corrected, repeat steps 2 and 3.
Tensioning Cable
Adjustment Screw
16.8 cm
8.6 cm
Dim Targa Premier A 22.54 cm Varies B 7.62 cm Varies
Single Station Control
Case Dimensions (Premier Tab Tension Surface Shown)
16.8 cm
1
R73 cm
63 mm
cm
1.7 cm
8.6 cm
B
Wiring Diagrams
CE Approved
Terminal strip in junction box at left end of screen
Surface Width + A
Multiple Station Control
Page 2 of 2
Not CE Approved
Terminal strip in junction box at left end of screen
Red
10 cm
Cap off with wire nut & tape
Blue
Two-Way Serial Communication
(RS232) with MC1
Terminal strip in
junction box at left
end of screen
Red-to Screen (directional)
Black-to Screen (directional)
Blue-Common
Brown-Hot to 230V AC
Program LED
Neutral
Hot
Low Voltage Wiring by others
Green/Yellow-Ground
Fuse
All-Pole Disconnect
by Others
STOP
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
230V, 50 Hz.
STOP
Control
Switches
24v DC
Eye Port for IR Eye. For RF Receiver
or LED Wall Switch, a Splitter and a
Power Supply is required. Plug RF
Receiver or LED Wall Switch and
Power Supply into splitter, then run
Manual Switch Up
cable from Splitter to MC1 Eye Port.
MC1
Control switch
Dashed wiring by electrician
Low Voltage & Wireless Control
Neutral
L1
PE
230V, 50 Hz.
Red-to screen (directional) Brown-to screen (directional) White-Common to screen, 230V AC Black-to 230V AC Yellow-to 230V AC Green-Ground
Dashed wiring by electrician
Eye Port for IR Eye, RF Receiver or LED Switch For more than one of these, a splitter is required.
3 Button Wall Switch DOWN - Black COM - White UP - Red
Low voltage wiring by others
Aux Por t for connecting additional LVC-III modules (up to six total­connect from Aux to Eye).
Red
Red
Neutral
Hot
230V, 50 Hz.
STOP
STOP
230V, 50 Hz.
Control Switches 24v DC
Black
Black
Black
Dashed wiring by electrician
Hot
Neutral
All-Pole Disconnect by Others
Blue
Blue
Terminal strip in junction box at left end of screen
See separate Serial Communication­RS232 Instruction sheet for enabling RS232 with the MC1.