Doyon DRP4, DRPR3, DRPR4, DRP3, DRP4S Instruction Manual

...
Page 1
PIZZA WARMER
DRP3 & DRPR3 DRP4 & DRPR4
DRP4S & DRPR4S
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
CAREFULLY FOLLOW THESE INSTRUCTIONS
SECTION « A » DESCRIPTION PAGE
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A1
Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Installation warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A5
For more information, please contact our office: . . . . . . . . . . . . . . . . . . . . A6
SECTION « B » DIMENSIONS
DRP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B1
DRPR3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B2
DRP4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B3
DRPR4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B4
DRP4S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B5
DRPR4S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B6
SECTION « E » COMPONENT PARTS
DRP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E1
DRPR3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E3
DRP4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E5
DRPR4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E7
DRP4S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E9
DRPR4S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E11
SECTION « G » ELECTRIC SCHEMATICS
DRP3 - 120V/1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . G1
Page 2
DRPR3 - 120V/1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G2
DRP3 - 230V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G3
DRPR3 - 230V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G4
DRP4 - 120V/1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G5
DRPR4 - 120V/1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G6
DRPR4 - 120V/1PH (1 DOOR SWITCH) . . . . . . . . . . . . . . . . . . . . . . . . G7
DRPR4 - 120V/1PH (2 DOOR SWITCH) . . . . . . . . . . . . . . . . . . . . . . . . G8
DRP4 - 230V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G9
DRPR4 - 230V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FAMDRP3A.DOC Rev. 31/03/05
Page 3
SECTION
A
DESCRIPTION
Page 4
A 1
INTRODUCTION
The manufacturer suggests to read this manual carefully.
This electric warmer is manufactured with first quality material by experienced technicians. Proper installation and maintenance will guarantee a reliable service for years to come.
A nameplate specifies the model number, serial number, voltage, amperage, frequency and manufacturing date.
Drawings, electrical diagram and replacement parts numbers are included in this manual.
ATTENTION
DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organisations.
Page 5
A 2
SHIPPING
For your safety, this equipment has been verified by qualified technicians and carefully crated before shipment. The freight company assumes full responsibility concerning the delivery in good condition of the equipment in accepting to transport it.
IMPORTANT
RECEPTION OF THE MERCHANDISE
Take care to verify that the received equipment is not damaged before signing the delivery receipt. If a damage or a lost part is noticed, write it clearly on the receipt. If it is noticed after the carrier has left, contact immediately the freight company in order that they do their inspection.
We do not assume the responsibility for damages or losses that may occur during transportation.
INSTALLATION WARNINGS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY APPLIANCE
INSTALLATION AND SERVICE
The warmer must be connected to the utility and electrically grounded in conformity to the effective local regulations. If these are not established, the warmer must be connected according to the National Electrical Code (NFPA 70-XX). This equipement has a male plug that meets those requirements.
Page 6
A 3
DISTANCES TO RESPECT
You must keep a clearance of one-inch (1") from combustibles material which includes the back, the top and the sides of the warmer.
GENERALITIES
Take off the packaging material with care. Take off all the material used for packing and accessories.
This equipment can be plugged on any network offering a protection of 15 amps.
Page 7
DRP3 & DRP4
1. Fill the pan with water.
2. Turn the switch "on".
3. Adjust the thermostat at 175° F.
DRP3R & DRPR4
1. Fill the pan with water.
2. Turn the two switches "on".
A 4
OPERATION
3. Adjust the thermostat at 175° F.
* To stop the rotation of the rack only, turns the right switch "off".
Page 8
A 5
OVEN MAINTENANCE AND CLEANING
Step by step Recommendations
Clean the inside of the warmer with water and soap
Take out the grills (the grills of the oven could be cleaned with "Easy-Off") After cleaning the inside of the warmer, apply a silicone base oven protector. It avoids food from sticking to the metal.
Clean the warmer windows with products like Brasso or equivalents. They are copper cleaners but good for this use.
Clean the warmer exterior with a stainless steel cleaner.
We recommend and sell: Durt Buster III : Action foam cleaner. CHEMCO Part number : NEB201
We recommend and sell: 316 Silicone base protector and lubricant for oven Dow Corning Part number : EXS400 We recommend and sell: Wright's: Cream copper cleaner J.A. Wright & Co. Part number : EXC300 We recommend and sell: Stainless steel cleaner. SANY or CURTIS (comestible) Part number : NES201
Page 9
A 6
FOR MORE INFORMATION,
PLEASE CONTACT OUR OFFICE:
DOYON EQUIPMENT INC.
1255, rue Principale, C.P. 250
Linière, Qc, Canada G0M 1J0
Tel. : 1 (418) 685-3431
Canada : 1 (800) 463-1636
U.S. : 1 (800) 463-4273
FAX : 1 (418) 685-3948
Internet: http://www.doyon.qc.ca
E-Mail : doyon@doyon.qc.ca
Page 10
SECTION
B
DIMENSIONS
Page 11
21 3/4
DRP3
B-1
DRP3
20 1/2
21 3/8
POWER ROTATING
210
200
190
180
170
160
150
140
120
250
OFF
220
230
240
Cooper
40
60
80
100
200
150
100
60
Page 12
21 3/4
DRPR3
B-2
20 1/2
21 3/8
ROTATINGPOWER
190
180
170
160
150
OFF
220
210
230
200
240
Cooper
40
60
140
80
120
100
200
250
150
100
60
DRPR3
Page 13
23 7/8
B-3
DRP4
DRP4
22 1/2
25 3/4
POWER
200
190
180
170
160
150
140
250
OFF
220
210
230
240
Cooper
40
60
80
120
100
200
150
100
60
Page 14
23 7/8
B-4
DRPR4
DRPR4
22 1/2
30 3/4
ROTATING
POWER
210
200
190
180
170
160
150
140
120
250
OFF
220
230
240
Cooper
40
60
80
100
200
150
100
60
Page 15
23 7/8
B-5
DRP4S
DRP4S
22 1/2
26 1/2
POWER
200
190
180
170
160
150
140
250
OFF
220
210
230
240
Cooper
40
60
80
120
100
200
150
100
60
Page 16
23 7/8
B-6
DRPR4S
DRPR4S
22 1/2
26 1/2
ROTATING
POWER
210
200
190
180
170
160
150
140
120
250
OFF
220
230
240
Cooper
40
60
80
100
200
150
100
60
Page 17
SECTION
E
COMPONENT PARTS
Page 18
E-1
DRP3
6
14
7
5
13
1211
4
POWER ROTATING
220
210
230
200
240
190
180
170
Cooper
3
2
160
40
150
60
140
80
120
100
200
250
150
OFF
100
60
1098
1
DRP3
Page 19
E-2
Item Part Number Description Quantity 1 50010823 DRP-3 & DRPR3 HINGE 1 2 VT1916 TEMPERED GLASS 5 MM 1 3 ELA325 BULB 40W 120V 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 50010824 DRP-3 & DRPR3 HANDLE 1 6 VT1815 TEMPERED GLASS 5 MM 3 7 ELE125 STRAIGHT ELEMENT 120V 1000W 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 1 13 PAP700 ADJUSTABLE CHROMED LEG 4 14 ELM759 COOLING FAN 1
Model : DRP3 View : BACK
Page 20
E-3
DRPR3
16
15
14
6
13
7
5
4
3
2
ROTATINGPOWER
190
180
170
160
150
OFF
220
210
230
200
240
Cooper
40
60
140
80
120
100
200
250
150
100
60
11 12
8 9 10
1
DRPR3
Page 21
E-4
Item Part Number Description Quantity 1 50010823 DRP-3 & DRPR3 HINGE 1 2 VT1916 TEMPERED GLASS 5 MM 1 3 ELA325 BULB 40W 120V 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 50010824 DRP-3 & DRPR3 HANDLE 1 6 VT1815 TEMPERED GLASS 5 MM 3 7 ELE125 STRAIGHT ELEMENT 120V 1000W 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 2 13 ELM759 COOLING FAN 1 14 ELM938 GEARMOTOR DAYTON 7 RPM 120 V 1 OR ELM937 GEARMOTOR DAYTON5,87 RPM 220V 50HZ 1 15 QURB013 THRUST BEARING 1 16 PAP700 ADJUSTABLE CHROMED LEG 4
Model : DRP3 ROTATIF View : BACK
Page 22
E-5
DRP4
6
5
4
14
7
13
3
1211
POWER
220
210
230
200
240
190
180
170
Cooper
160
40
150
60
140
80
120
100
1098
2
200
250
150
OFF
100
60
1
DRP4
Page 23
E-6
Item Part Number Description Quantity 1 50010821 DRP-4 & DRPR4 HINGE 1 2 VT2121 TEMPERED GLASS 5 mm 1 3 50010822 DRP-4 & DRPR4 HANDLE 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 ELA275 BULB 60W 130V 1 6 VT2020 TEMPERED GLASS 5 mm 3 7 ELE127 HEATING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 1 13 PAP700 ADJUSTABLE CHROMED LEG 4 14 ELM759 COOLING FAN 1
Model : DRP4 View : BACK
Page 24
E-7
DRPR4
16
6
15
14
5
4
13
7
3
2
1
DRPR4
ROTATING
POWER
210
200
190
180
170
160
150
140
120
250
OFF
1211
220
230
240
Cooper
40
60
80
100
200
150
100
60
1098
Page 25
E-8
Item Part Number Description Quantity 1 50010821 DRP-4 & DRPR4 HINGE 1 2 VT2121 TEMPERED GLASS 5 mm 1 3 50010822 DRP-4 & DRPR4 HANDLE 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 ELA275 BULB 60W 130V 1 6 VT2020 TEMPERED GLASS 5 mm 3 7 ELE127 HEATING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 2 13 ELM759 COOLING FAN 1 14 ELM938 GEARMOTOR DAYTON 7 RPM 120 V 1 OR ELM937 GEARMOTOR DAYTON5,87 RPM 220V 50HZ 1 15 QURB013 THRUST BEARING (BEARING) 1 16 PAP700 ADJUSTABLE CHROMED LEG 4
Model : DRPR4 ROTATIF View : BACK
Page 26
E-9
DRP4S
6
14
7
5
13
1211
4
3
POWER
220
210
230
200
240
190
180
170
Cooper
160
40
150
60
140
80
120
100
1098
21
200
250
150
OFF
100
60
DRP4S
Page 27
E-10
Item Part Number Description Quantity 1 50010821 DRP-4 & DRPR4 HINGE 1 2 VT2121 TEMPERED GLASS 5 mm 1 3 50010822 DRP-4 & DRPR4 HANDLE 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 ELA275 BULB 60W 130V 1 6 VT2020 TEMPERED GLASS 5 mm 3 7 ELE127 HEATING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 1 13 PAP700 ADJUSTABLE CHROMED LEG 4 14 ELM759 COOLING FAN 1
Model : DRP4S View : BACK
Page 28
E-11
DRPR4S
16
15
14
6
13
7
5
1211
4
ROTATING
POWER
3
220
210
230
200
240
190
180
170
Cooper
160
40
150
60
140
80
120
100
1098
21
200
250
150
OFF
100
60
DRPR4S
Page 29
E-12
Item Part Number Description Quantity 1 50010821 DRP-4 & DRPR4 HINGE 1 2 VT2121 TEMPERED GLASS 5 mm 1 3 50010822 DRP-4 & DRPR4 HANDLE 1 4 ELD050 INCANDESCENT LIGHT SOCKET 1 5 ELA275 BULB 60W 130V 1 6 VT2020 TEMPERED GLASS 5 mm 3 7 ELE127 HEATING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG & CORD 1 9 ELT610 THERMOSTAT 250F 1 & ELT622 THERMOSTAT BEZEL 1 & ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40-240°F 1 12 ELI635 SWITCH 20A/130V - 15A/240 V P. LIGHT 2 13 ELM759 COOLING FAN 1 14 ELM938 GEARMOTOR DAYTON 7 RPM 120 V 1 OR ELM937 GEARMOTOR DAYTON5,87 RPM 220V 50HZ 1 15 QURB013 THRUST BEARING (BEARING) 1 16 PAP700 ADJUSTABLE CHROMED LEG 4
Model : DRPR4S ROTATIF View : BACK
Page 30
SECTION
G
ELECTRIC SCHEMATIC
Page 31
G-1
1000 W
ELEMENT
P.L.
1 / 1
DRP3R_1
STANDARD
DRP3 120V 60 Hz
31/03/05 M. FAUCHER 2
2−6−7 & 9
40 W
BULB
120 8.5 8.5
TOTAL POWER: 1.0 Kw 60 Hz
FAN
COOLING
ON/OFF
SWITCH
L1N
Page 32
G-2
1000 W
ELEMENT
P.L.
1 / 1
DRP3R_1
ROTATIF
DRPR3 120V 60 Hz
2 & 6
31/03/05 M. FAUCHER 2
ON/OFF
SWITCH
40 W
MOTOR
SWITCH
120 9.0 9.0
TOTAL POWER: 1.1 Kw 60 Hz
BULB
FAN
COOLING
M
L1N
Page 33
G-3
1 / 1
1260 W
ELEMENT
P.L.
DRP3R_1
STANDARD
DRP3 230V 50 Hz
31/03/05 M. FAUCHER 2
2−5−7 & 9
230 6.0 6.0
TOTAL POWER: 1.4 Kw 50 Hz
L1N
ON/OFF
SWITCH
40 W
BULB
FAN
COOLING
Page 34
G-4
1260 W
ELEMENT
P.L.
1 / 1
DRP3R_1
ROTATIF
DRPR3 230V 50 Hz
2 & 5
31/03/05 M. FAUCHER 2
ON/OFF
SWITCH
40 W
MOTOR
SWITCH
230 6.5 6.5
TOTAL POWER: 1.5 Kw 50 Hz
BULB
FAN
COOLING
M
L1N
Page 35
G-5
1250 W
ELEMENT
P.L.
1 / 1
DRP4R_1
STANDARD
DRP4 120V 60 Hz
31/03/05 M. FAUCHER 2
2−3−4−6−7 & 9
BULB
120 11.0 11.0
TOTAL POWER: 1.3 Kw 60 Hz
FAN
COOLING
ON/OFF
SWITCH
L1
N/L2
Page 36
G-6
1250 W
ELEMENT
P.L.
1 / 1
DRP4R_1
ROTATIF
DRPR4 120V 60 Hz
2−3 & 6
31/03/05 M. FAUCHER 2
ON/OFF
SWITCH
MOTOR
SWITCH
120 11.5 11.5
TOTAL POWER: 1.4 Kw 60 Hz
BULB
FAN
COOLING
M
L1
N/L2
Page 37
G-7
DOOR SWITCH
1 / 1
1250 W
ELEMENT
P.L.
DRP4R_1
ROTATIF
DRPR4 120V 60 Hz
3−6 & 7
31/03/05 M. FAUCHER 2
120 11.5 11.5
TOTAL POWER: 1.4 Kw 60 Hz
L1
ON/OFF
SWITCH
DOOR
SWITCH
MOTOR
SWITCH
BULB
FAN
COOLING
M
N/L2
Page 38
G-8
DOOR SWITCH2
1 / 1
1250 W
ELEMENT
P.L.
DRP4R_1
ROTATIF
DRPR4 120V 60 Hz
4−6 & 7
31/03/05 M. FAUCHER 2
120 11.5 11.5
TOTAL POWER: 1.4 Kw 60 Hz
L1
ON/OFF
SWITCH
DOOR
SWITCH
DOOR
SWITCH
MOTOR
SWITCH
BULB
FAN
COOLING
M
N/L2
Page 39
G-9
1260 W
ELEMENT
P.L.
1 / 1
DRP4R_1
STANDARD
DRP4 230V 50 Hz
31/03/05 M. FAUCHER 2
2−3−4−5−7 & 9
BULB
230 6.0 6.0
TOTAL POWER: 1.4 Kw 50 Hz
FAN
COOLING
ON/OFF
SWITCH
L1
N/L2
Page 40
G-10
1260 W
ELEMENT
P.L.
1 / 1
DRP4R_1
ROTATIF
DRPR4 230V 50 Hz
2−3 & 5
31/03/05 M. FAUCHER 2
BULB
230 6.5 6.5
TOTAL POWER: 1.5 Kw 50 Hz
FAN
COOLING
M
ON/OFF
SWITCH
L1
N/L2
MOTOR
SWITCH
Page 41
LIMITED WARRANTY
(Continental United States Of America And Canada Only)
Doyon Equipment Inc. guarantees to the original purchaser only that its product are free of defects in material and workmanship, under normal use.
This warranty does not cover any light bulbs, thermostat calibration or defects due to or resulting from handling, abuse, misuse, nor shall it extend to any unit from which the serial number has been removed or altered, or modifications made by unauthorised service personnel or damage by flood, fire or other acts of God. Nor will this warranty apply as regards to the immersion element damaged by hard water.
The extent of the manufacturer’s obligation under this warranty shall be limited to the replacement or repair of defective parts within the warranty period. The decision of the acceptance of the warranty will be made by Doyon Equipment service department, which decision will be final.
The purchaser is responsible for having the equipment properly installed, operated under normal conditions with proper supervision and to perform periodic preventive maintenance.
If any parts are proven defective during the period of one year from date of purchase, Doyon Equipment Inc. hereby guarantees to replace, without charge, F.O.B. Linière, Quebec, Canada, such part or parts.
Doyon Equipment Inc will pay the reasonable labour charges in connection with the replacement parts occurring within one year from purchase date. Travel over 50 miles, holiday or overtime charges are not covered. After one year from purchase date, all labour and transportation charges in connection with replacement parts will be the purchaser’s responsibility.
Doyon Equipment Inc. does hereby exclude and shall not be liable to purchaser for any consequential or incidental damages including, but not limited to, damages to property, damages for loss of use, loss of time, loss of profits or income, resulting from any breach or warranty.
In no case, shall this warranty apply outside Canada and continental United States unless the purchaser has a written agreement from Doyon Equipment Inc.