dormakaba Canada LPR10M Users Manual

PK2963 02/03 Issue 1 2 of 4
Installation Sheet: LEGIC Proximity Reader (LPR-10M)
Introduction & Preparation
Requirements
Millenium DCD circuit board with an EPROM issue level “Y” or higher (a paper label on the DCD EPROM chip identifies the issue level).
Mullion Mount
Mullion having a minimum width of 1.80”.
External dimensions:
Height: 3 _ ” (90 mm)
Width: 1 _ ” (46 mm)
Projection: _ ” (21 mm)
3/4” hole drilled in the mullion front face for passing the reader cable.
Two other holes must also be drilled – see Table 1 below for dimensions of holes according to material to be drilled.
Two # 4 – 1 _” (32 mm) Phillips pan zinc plated screws supplied with the reader kit.
Millenium DCD circuit board with an EPROM issue level “Y” or higher. (A paper label on the DCD EPROM chip identifies the issue level)
Millenium software release 3.0 or higher.
Installation
1. Drill one _” (21 mm) hole for passing the reader cable through.
1. Drill two holes for fixing the reader to the surface (see Table below for dimensions of hole appropriate for type of surface material).
1. Affix the reader using the two # 4 – 1 _” (32 mm) Phillips pan zinc plated screws supplied with the reader kit.
1. An installation diagram (Figure 1) is in the left-hand column of this sheet.
Table 1
Surface Material
Diameter of “A” Holes
Plugs
Metal
5/64” (2 mm)
N/A
Concrete
3/16” (4 mm)
concrete screw anchors
Drywall
3/16” (4 mm)
drywall nylon grip plugs
LPR-10M Price List
120-510520 Mullion Mount Reader unit Kit with: 009-510655-2 1 spacer 890-510752 2 screws for steel, concrete or drywall 999-510754 2 concrete screw anchors (white) 999-510753 2 drywall nylon grip plugs 009-510655-3 Self-adhesive fascia with foil LED 009-510655-4 Self-adhesive fascia with foil logo
Figure 1: Installation Diagram
Loading...