Domus Ventilation DX6WL, DX12WL Installation Instructions

Page 1
The EMC Direcve
2014/30/EU
The Low Voltage Direcve
2014/35/EU
DX Wall Fan Kits 50/60Hz
Supply / Extract Units
Installaon and Maintenance
269mm
134 mm*
269mm
137mm*
272mm
DX6WL (6 inch)
Front view
DX9WL (9 inch) DX12WL (12 inch)
Side view
Cable entry
Aperture required 260 x 260mm sq.
*To centre of 'duct'
337 mm
171 mm*
342mm
175mm*
342mm
Cable entry
*To centre of 'duct'
413mm
206mm*
420mm
214 mm*
420mm
Cable entry
*To centre of 'duct'
Aperture required 330 x 330mm sq.
Aperture required 410 x 410mm sq.
V E N T I L A T I O N
269mm
272mm
DX6WL (6 inch)
Front view
DX9WL (9 inch) DX12WL (12 inch)
Side view
342mm
342mm
420mm
420mm
DX Wall Fan Kit 50Hz/ 60Hz
Supply / Extract Units – Installaon and Maintenance
IMPORTANT: Installaon or replacement of units or spare parts must be carried out by a qualified or Nuaire approved service engineer/ electrician and in accordance with IEE or local naonal wiring regulaons.
2.0 Introducon
The Domus DX Wall Fan Kit is available in 6, 9 and 12 inch impeller sizes suitable for supply or extract and can be the heart of a room’s automac venlaon system.
Ensure adequate air replacement for the fan and any fuel burning appliance in the room.
Figure 1. Main components of wall installaon assembly.
Outer grille
Wall sleeve
Inside grille
Fan assembly
2.1 Switching
Operated via a separately wired 3 amp fused spur (by others) or operated via the optional DX-CON remote controller allowing supply or extract, variable speed and automatic or manual switching of several fans if desired.
2.2 Sensors
Sensors are available as remote units or integral ‘plug in’ units. They are able to control mulple fans, depending on sensor and fan types.
Integral sensors are quick and easy to install and are aesthecally pleasing, whilst remote sensors give the benefit of locaon close to the pollutant source. Remote sensors can be fied with an oponal security strap to prevent unwanted tampering.
2.3 General
The removable interior grille provides easy access while the external rotor motor makes for simple removal of the push-on impeller for cleaning. Upward angled interior grille vanes shield workings from view and downward sloping external vanes throw off rain. The fan is IP24 splash proof approved with the motor rated at IP44.
All external components are made in so grey colours from ultra violet stable ABS material so they will blend with most decors and will not fade in sunlight.
2.3.1 Coding For Wall Fan Kits
Descripon Code*
6 inch Wall Fan Kit Complete DX6WL
9 inch Wall Fan Kit Complete DX9WL
12 inch Wall Fan Kit Complete DX12WL
Wall Fan Kits are supplied as a complete package with all wall installaon parts included.
3.0 Dimensions
Front view
DX6WL (6 inch)
269mm
LAB1349R May 2018
Front view
DX9WL (9 inch) DX12WL (12 inch)
272mm
342mm
342mm
Rear view
DX6WA (6 inch)
420mm
128mm
DX9WA (9 inch) DX12WA (12 inch)
Aperture required 260 x 260mm sq.
420mm
Cable entry
134 mm*
269 mm
130mm
137 mm*
*To centre of 'duct'
Aperture required 330 x 330mm sq.
Cable entry
171 mm*
337 mm
169 mm
175mm*
*To centre of 'duct'
Aperture required 410 x 410mm sq.
Cable entry
206 mm*
413mm
214 mm*
*To centre
of 'duct'
Page 1
Page 2
Polystyrene former fits temporarily into sleeve end
Make hole for supply cable
Locate the temporary plug to support the other end.
Polystyrene former supporng sleeve end
A
A
2
4
6
8
Supply wire
inside sleeve
Make good around the wall sleeve.
Remove fan plate.
Cut the spacer to match the walls total thickness using a fine/med cut woodsaw.
Make good the inside and outside walls
flush with the
sleeve
Temporary crossbrace
Installation and Maintenance
DX Wall Fan Kits 50Hz/60Hz
4.0 Installaon
4.1 Installaon Of Wall Fan Kits
1
Remove front grille. Release 2 screws. Li grille upwards.
3
DX6WA 260mm sq.
DX9WA 330mm sq.
DX12WA 410mm
sq.
V E N T I L A T I O N
2
Remove fan plate.
4
A
Prepare the wall aperture to dimensions shown.
5
Fit the temporary cross brace across wall sleeve’s outer end to support the sides during installaon (drg No 8).
7
IMPORTANT !
Install the sleeve at a slight angle (lower to outside)
When fing the sleeve, introduce a slight downward slope to the outside, to encourage any water to drain to outside.
LAB1349R May 2018
A
Cut the spacer to match the walls total thickness using a fine/med cut woodsaw.
6
Locate the temporary plug to support the other end.
Make hole for supply cable
Polystyrene former fits temporarily into sleeve end
8
INSIDEOUTSIDE
Temporary crossbrace
Make good around the wall sleeve.
Supply wire
inside sleeve
Make good the inside and outside walls
flush with the
sleeve
Polystyrene former supporng sleeve end
Page 2
Page 3
Installation and Maintenance
10
12
Release the electrical cover from the fan plate.
Assemble the fan plate to the inside sleeve.
IMPORTANT
(Shuer Operaon DX fans)
There will be a short delay on start-up and shutdown of
approximately 40 seconds, this is normal.
Fit the inside grille to the fanplate, locang grille over the top lip before engaging screws.
9
10
11
13
12
Bring the cable through the fan plate.
Remove temporary cross brace when cement has dried. Fit the outer grille (note grille blades sloping down to shed water).
Release the electrical cover from the fan plate.
Assemble the fan plate to the inside sleeve.
IMPORTANT
(Shuer Operaon DX fans)
There will be a short delay on start-up and shutdown of
approximately 40 seconds, this is normal.
4.2 Fing Ancillaries (Also see page 8)
4.2.1 Thin Wall Installaon
This thin wall applicaon is best covered using a Window Kit. Drawing shows a Wall Fixing Plate fixed to the aperture by screws. The Window Kit clamps together either side of the Wall Fixing Plate.
4.2.2 Weather Terminal
This wall applicaon shows a Weather Terminal replacing the Outside Grille and is held in posion using the grille fixing points. However, longer (75mm) screws are provided. This Terminal is used for exposed site
condions.
Spacer
Wall Fixing Plate
Interior Grille
Outside Grille
DX Wall Fan Kits 50Hz/60Hz
9
Remove temporary cross brace when cement has dried. Fit the outer grille (note grille blades sloping down to shed water).
11
10
Release the electrical cover from the fan plate.
12
V E N T I L A T I O N
Bring the cable through the fan plate.
13
Fit the inside grille to the fanplate, locang grille over the top lip before engaging screws.
Assemble the fan plate to the inside sleeve.
IMPORTANT
There will be a short delay on start-up and shutdown of
approximately 40 seconds, this is normal.
(Shuer Operaon DX fans)
Min thickness 25mm MDF
LAB1349R (version 1) April 2018 Page 3
Page 4
Installation and Maintenance
DX Fan unit with
2
4
Remove the terminal cover.
Refit terminal cover before replacing the electrical panel.
5.1.3 Basic Fan Operated By Remote Sensor
Fan operated by on / off switch
Fan operated by integral sensor
Double pole isolator
Fuse max. 3 amp
L5
L4
L3
L2
L1
N
or
L
N
DX Fan unit with
Fan operated by integral sensor
SL
(Switched Live)
Connect link wire between L2 & L4 for extract OR connect link wire between L2 & L3 for supply.
IMPORTANT
Isolaon - Before commencing work, make sure that the unit is
electrically isolated from the mains supply.
DX Wall Fan Kits 50Hz/60Hz
5.0 Electrical Installaon
Electrical work should be undertaken by a qualified electrician in accordance with the wiring regulaons.
1
Release the electrical panel from the fan plate.
3
2
Remove the terminal cover.
4
V E N T I L A T I O N
Clamp the cable and complete the connecons.
5.1 Wiring
5.1.1 Fan Operated By On / Off Switch
Double pole isolator
L
N
Connect link wire between L2 & L4 for extract OR connect link wire between L2 & L3 for supply.
Fuse max. 3 amp
5.1.2 Fan Operated By Integral Sensor
SL
(Switched Live)
Double pole isolator
L
N
Connect link wire between L2 & L4 for extract OR connect link wire between L2 & L3 for supply. Connect switched live signal to L5 for integral mer module.
Fuse max. 3 amp
or
DX Fan unit with integral sensor
or
L5
L4
L3
L2
L1
N
DX Fan unit
L5
L4
L3
L2
L1
N
Refit terminal cover before replacing the electrical panel.
5.1.3 Basic Fan Operated By Remote Sensor
Fan operated by integral sensor
SL
Connect link wire between L2 & L4 for extract OR connect link wire between L2 & L3 for supply.
(Switched Live)
L
N
Double pole isolator
Fuse max. 3 amp
IMPORTANT
Isolaon - Before commencing work, make sure that the unit is
electrically isolated from the mains supply.
L5
or
L4
L3
L2
L1
N
LAB1349R May 2018
Page 4
Page 5
Installation and Maintenance
y.
Supply / Extract fan operated via remote DX-MFC control
Remote sensor
Supply / Extract fan operated via remote DX-MFC control & Remote Sensor(s)
IMPORTANT
(Shuer Operaon DX fans)
There will be a short delay on startup and shutdown of
approximately 40 seconds. This is normal.
Model
Input Power
(W)
Weight
(kg)
Max. Economy
DX6WA supply & extract 38 20 4.7
DX6GL supply & extract 50 37 6.5
DX6GL supply & extract 100 70 9.4
5.2 Unit Consumpon & Weight
5.3 Electrical Specificaon
230V ~ 50Hz / 220V ~ 60Hz Class I. Motor thermally protected by overload device. Cable: 1mm max. or min. Fuse: 3 amp (if fan is supplied from a 5A lighng circuit, no local fuse is required).
Note: If 2 x 12 inch fans or 3 x 6 or 9 inch fans are used in the same operang mode in the same room they should all be controlled from the same MFC speed control. This avoids the possibility of one fan (if speed controlled at a lower flow rate) being stalled by the other fan(s).
Adequate make-up air provision sufficient to provide venlaon in accordance with building regulaons is required in all rooms. This should be checked during commissioning with all fans in the same room running together in all possible configuraons.
The automac shuers, motor bearings should be frequently inspected and maintained to ensure they open fully/operate sasfactorily. Use of an RCD and fused spur with 1A, BussmannTDC180, BS1362, fuse (Farnell order no: 1123029) for 1 fan or 2A, Bussmann TDC180, BS1362 fuse (Farnell order no: 1123032) for 2 or 3 fans is recommended.
Always confirm airflow direcon before commissioning.
Note figures are for extract only at 50hz.
DX Wall Fan Kits 50Hz/60Hz
5.1.4 Supply / Extract Fan Operated via remote DX-CON Control
Double
Fuse
pole
max.
isolator
L
N
mains supply
3 amp
Remote switch may be set: On/Off, Supply/ Extract, Economy/Std
(variable speed), Auto/Manual.
5.1.5 Supply / Extract Fan Operated via remote DX-CON Control
Double
Fuse
pole
max.
isolator
L
N
mains supply
Remote sw
3 amp
itch may be set: On/Off, Supply/ Extract, Economy/Std.
(variable speed), Auto/Manual.
One or more Remote Sensors may be wired in parallel to one DX-CON Control. Humidity Se
nsor: DX-RH
5.1.6 Supply / Extract Fan Operated via remote DX-CON Control
Supply / Extract fan operated via remote DX-
CON control and Integral Sensor
Double
Fuse
pole
max.
isolator
3 amp
mains supply
L
N
Remote switch may be set: On/Off, Supply/ Extract, Economy/ Std.
(variable speed), Auto/Manual.
Maximum
one Integral Sensor per fan, 6/9/12 denotes unit size ident
Humidity Sensor: DX-H6/9/12 Passive Infra Red Sensor: DX-PIR6/9/12 Run on Tim
er: DX-T6/9/12.
A single sensor will switch all fans if more than one fan is being
perated by DX-CON controller.
o a single
NOTE: Mul-fan opons:
Up to 5 fans (size 6"/9") can Up to 2 fan Do not mix different fan sizes on the same controller.
s (size 12") can be controlled by one DX-CON.
L4
L3
L2
L1
NL1N
DX-CON controller
L2 L1 N
L4
L3
L2
L1
NL1N
DX-CON controller
Required if using integral Timer
L4
L3
L2
L1
NL1N
DX-CON controller
be controlled by one DX-CON
L5
L4
L3
L2
L1
N
DX Fan unit
L5
L4
L3
L2
L1
N
DX Fan unit
L5
L4
L3
L2
L1
N
DX Fan unit with integral sensor
V E N T I L A T I O N
IMPORTANT
There will be a short delay on startup and shutdown of
5.2 Unit Consumpon & Weight
DX6WL supply & extract
DX9WL supply & extract
DX12WL supply & extract
Note figures are for extract only at 50hz.
5.3 Electrical Specificaon
230V ~ 50Hz / 220V ~ 60Hz Class I. Motor thermally protected by overload device. Cable: 1mm max. or min. Fuse: 3 amp (if fan is supplied from a 5A lighng circuit, no local fuse is required).
Note: If 2 x 12 inch fans or 5 x 6 or 9 inch fans are used in the same
operang mode in the same room they should all be controlled from
the same DX-CON speed control. This avoids the possibility of one fan (if speed controlled at a lower flow rate) being stalled by the other fan(s).Adequate make-up air provision sufficient to provide ventilation in
accordance with building regulaons is required in all rooms. This should be checked during commissioning with all fans in the same room running together in all possible configuraons.
The automac shuers, motor bearings should be frequently inspected and maintained to ensure they open fully/operate sasfactorily. Use of an RCD and fused spur with 1A, Bussmann TDC180, BS1362, fuse (Farnell order no: 1123029) for 1 fan or 2A, Bussmann TDC180, BS1362 fuse (Farnell order no: 1123032) for 2 or 3 fans is recommended.
Always confirm airflow direcon before commissioning.
(Shuer Operaon DX fans)
approximately 40 seconds. This is normal.
Input Power
Model
(W)
Max. Economy
38 20 4.7
50 37 6.5
100 70 9.4
Weight
(kg)
LAB1349R May 2018
Page 5
Page 6
Installation and Maintenance
Screw the sensor module into posion.
1
3
5
7
Push the repacement cover into the grille front.
Li out the sensor module wiring connector.
Unscrew the module plate from motor plate assy.
DX Wall Fan Kits 50Hz/60Hz
5.4 Fing Integral Sensors (Oponal)
Note: Before following the pictorial sequence shown, first remove the fans front cover grille (2 screws). Release the four main corner screws and li out the motor/fan plate assembly. Remove the electrical cover plate opposite the sensor plate. Follow the pictorial sequence on this page.
2
1
Unscrew the module plate from motor plate assy.
3
V E N T I L A T I O N
Remove the module plate.
4
Plug the connector into the required sensor module.
6
Li out the sensor module wiring connector.
5
Screw the sensor module into posion.
7
Push out the sensor area cover from the grille.
LAB1349R May 2018
Push the repacement cover into the grille front.
Page 6
Page 7
Installation and Maintenance
Feed approx. 200mm of supply cable into the box
1
3
5
7
Fit the control into the backplate box and secure. Test the installaon.
Lift up panel and remove two screws to dismantle unit.
Spot through backplate box and drill and plug the ceiling.
200mm
1.5m
ed, (see
DX Wall Fan Kits 50Hz/60Hz
5.5 Fing Remote Controller DX-CON or Remote sensors (oponal)
The DX-CON Mul Fan Control provides supply or extract, variable speed and automac or manual switching of several fans if desir
note below). The control is best mounted approx 1.5m above the floor. Remote Sensors are available for Humidity only. Remote Sensors should be positioned at least 1.5m above the floor and away from direct heat sources e.g. radiators
Note: Up to 5 fans (size 6 / 9 inch) can be controlled by one DX-CON. Up to 2 fans (size 12 inch) can be controlled by one DX-CON. Do not mix different fan sizes on the same controller.
2
V E N T I L A T I O N
1
Lift up panel and remove two screws to dismantle unit.
3
1.5m
Push out backplate box cable entry using a screwdriver.
4
Fix backplate box to the prepared ceiling.
6
Spot through backplate box and drill and plug the ceiling.
5
200mm
Feed approx. 200mm of supply cable into the box
7
Connect the end of the cable into the control block.
LAB1349R May 2018
Fit the control into the backplate box and secure. Test the installaon.
Page 7
Page 8
Installation and Maintenance
DX Wall Fan Kits 50Hz/60Hz
6.0 Ancillaries
Weather Terminal
Used for exposed site wall installaons, comprising one weather terminal, manufactured from HIPS.
Order Code DX-WT6 Dimensions: 360 x 360 x 170mm
Order Code DX-WT9 Dimensions: 425 x 425 x 180mm
Order Code DX-WT12 Dimensions: 506 x 506 x 185mm
Unit replaces the outside grille and is supplied with installaon details.
Picture Frame Adaptor
Used for exposed site wall installaons, comprising one weather terminal, manufactured from HIPS.
Order Code DX-PF6 Dimensions: 330 x 315 x 20mm
Order Code DX-PF9 Dimensions: 405 x 425 x 20mm
Order Code DX-PF12 Dimensions:495 x 510 x 25mm
V E N T I L A T I O N
Outside Grille
Spacer
Wall Fixing Plate
Thin Wall Applicaons
For thin wall applicaons we actually recommend the use of a Window Fan Kit used in conjuncon with a Wall Fixing Plate.
This thin wall applicaon shows a Wall Fixing Plate fixed to the aperture (4 screws). The Window Fan Spacer and Outside Grille clamp together either side of the Wall Fixing Plate to support the Fan and Interior Grille.
Interior Grille
7.0 Maintenance
Periodically, at least once a year or more frequently in case of heavy use, remove the dirt and encrustaon from the grille(s) fan impeller
and motor casing. Ensure the impeller is not cracked or deformed and is able to rotate freely and without oscillaon.
Do not use any solvents to clean this product.
8.0 Replacement Of Parts
As a manufacturer Domus is aware that me is important. In the event of a breakdown of this equipment, it should be adequately packaged and returned to Domus.
Please telephone Domus before posting your unit. A returns number will be issued to identify your package.
9.0 Warranty
The 2 year warranty starts from the day of delivery and includes parts and labour for the first year. The remaining period covers replacement parts only.
This warranty is void if the equipment is modified without
authorisaon, is incorrectly applied, misused, disassembled, or not installed, commissioned and maintained in accordance with the details contained in this manual and general good pracce.
Installaon or replacement of units or spare parts must be carried out
by a qualified or Domus approved service engineer/ electrician and in accordance with IEE or local naonal wiring regulaons.
The product warranty applies to the UK mainland and in accordance with Clause 14 of our Condions of Sale.
10.0 Aer Sales Enquiries
For technical assistance or further product informaon, including spare parts and replacement components, please contact the Aer Sales Department.
Technical or commercial consideraons may, from me to me, make it necessary to alter the design, performance and dimensions of equipment
and the right is reserved to make such changes without prior noce.
V E N T I L A T I O N
Domus Ventilation Block C Caerphilly Business Park
V an Road Caerphilly CF83 3ED
T el: +44 (0)3443 715523
Fax: +44 (0)3443 715524
www.domusventilation.co.uk
LAB1349R May 2018
The EMC Directive 2014/30/EU
The Low Voltage Directive
2014/35/EU
Page 8