Dometic TJ22, TJ42, TJ80, TJ18, TJF42 User Manual

RECORD THIS UNIT INFORMATION FOR
C
S
L-0938
FUTURE REFERENCE: Model Number Serial Number Date Purchased
MODELS
TJ18, TJ22, TJ42, TJ80
Refrigerator
and
TJF42
USA
Dometic Enviormental Corporation 200 North Andrews Avenue Extension Pompano Beach, FL 33069 954-973-2477
Dometic Enviormental Corporation 8433 Erie Road Mechanicsville, VA 23116 804-746-1313
Freezer
U
This manual must be read and un­derstood before installation, ad­justment, service, or maintenance is performed. This unit must be in­stalled by a qualified service tech­nician. Modification of this prod­uct can be extremely hazardous and could result in personal injury or property damage.
INSTALLATION & OPERATING
INSTRUCTIONS
REVISION
Form No. 3309080.039 1 1/06 (Replaces 3309080.020) ©2006 Dometic Corporation LaGrange, IN 46761
Important: These Instructions
must stay with unit. Owner read carefully.
1
MODEL
Series
TJ18 TJ42
TJ80
TJ22 TJF42
WARNING
CAUTION
CAUTION
TJ18, TJ22, TJ42, TJF42 & TJ80 Installation And Operating Instructions
SAFETY INSTRUCTIONS
This manual has safety information and instruc­tions to help users eliminate or reduce the risk of accidents and injuries.
RECOGNIZE SAFETY INFORMATION
!
This is the safety-alert symbol. When you see this symbol in this manual, be alert to the poten­tial for personal injury.
GENERAL INFORMATION
A. Before installing your Dometic refrigerator , refer to the
Tundra Installation Check List 3309081.0XX located in the envelope assembly furnished with your Tundra Refrigerator.
B. This refrigerator is designed for making ice and the
conservation of food and drinks only .
C. All materials exposed to contact with food comply with
EC directive 89/109.
D. Inst all appliance away from heat sources in a dry and
well-ventilated area. Avoid direct contact with water.
The Refrigerator is not waterproof.
E. This refrigerator complies with EC directive 89/336
governing radio suppression.
Note: The data plate bearing the model number , serial num­ber, and technical data is located on the right-hand side, inside the refrigerator. An identical dat a plate is located on the back of the cabinet.
SPECIFICATIONS
Follow recommended precautions and safe op­erating instructions.
UNDERSTAND SIGNAL WORDS
A signal word , WARNING OR CAUTION is used with the safety-alert symbol. They give the level of risk for potential injury.
!
ous situation which, if not avoided, could result in death or serious injury.
!
ous situation which, if not avoided may result in minor or moderate injury.
symbol indicates, a potentially hazardous situa­tion which, if not avoided may result in property damage.
Read and follow all safety information and in­structions.
indicates a potentially hazard-
indicates a potentially hazard-
used without the safety alert
A. Danfoss Compressor Data
1. Volt age Operating Range 12 VDC systems: From 10.4 VDC to 17 VDC 24 VDC systems: From 22.8 VDC to 31.5 VDC
The electronic unit will calibrate automatically to the applied voltage. This means that if the battery voltage is less than 17 VDC, the electronic unit as­sumes that it is working in a 12 VDC System. If the voltage is higher than 17 VDC, the electronic unit assumes that it is working in a 24 VDC system. Consequently, the compressor does not run at power supply voltages between about 17 VDC and the desired battery protection cutout voltage (22.8 VDC) for 24 VDC systems.
2. Protection Systems The compressor protection system facilitates pro­tection against compressor overload and start fail­ure as well as destructive battery discharge. When an overload protection is activated, the compres­sor enters a cycle in which it makes start attempts at approximately 60 second intervals until success­ful start is achieved.
3. Overload Protections The compressor overload and start protection cuts off power to the compressor if the compressor speed drops below approximately 1,900 rpm, or if this motor speed is not reached during the start sequence. Possible reasons for overload protec­tion activating could be too high refrigeration sys­tem pressures during operation or lack of pres­sure equalizing at start. The fan overload protection stops the compressor and the fan if the fan current exceeds 0.5 A (aver­age) or 1 A (peak).
2
An overheating of the electronic unit heat sink will cause the compressor to stop. Restart will occur automatically when a normal temperature has been reached.
4. Voltage Protection If a voltage outside the operating range is applied to the electronic unit, the compressor does not start, or it stops if the voltage limit is exceeded during operation. The compressor will restart automati­cally approximately 1 minute after the supply volt­age has reached the reset voltage within the range in question.
5. Battery Protection The electronic unit provides protection as follows:
Standard Battery Protection Settings
12 VDC 12 VDC 24 VDC 24 VDC
cutout cutin cutout cutin
10.4 1 1.7 22.8 24.2
ABYC Standards - ABYC Guidelines E9 - Direct Current
Conductor Sizes For 3 % Drop in Voltage
TJ18, TJ22, TJ42, TJF42 & TJ80 Installation And Operating Instructions
Refrigerator Amperage
Model Amperage
12 VDC 24 VDC
TJ18, TJ22 & TJ42 3.72 1.86
TJF42 & TJ80 4.56 2.28
See Amp Draw Chart Above To Determine Wire Size
Length of Conductor from Source of Current to Device and Back to Source - Feet
Total Current On Circuit In Amps 12 Volts - 3% Drop Wire Size (gauge) - Based on Minimum CM Area
5 181614121210101088866666666 10 141210101086666444422222 15 1210108866644222221111 20 101086664422221110002/0 25 10866644222110002/02/02/03/0 30 108664422110002/02/03/03/03/03/0 40 86644221002/02/03/03/03/04/04/04/04/0 50 664422102/02/03/03/04/04/04/0 60 64422102/03/03/04/01 4/0 4/0 70 6422102/03/03/04/04/0 80 6422103/03/04/04/0 90 422102/03/04/04/0 100 422102/03/04/0
5 1818181616141212121010101010 8 8 8 88 10 181614121210101088866666666 15 1614121210108866666444442 20 141210101086666444422222 25 12121010866644442222221 30 1210108866444222221111 40 101086664422221110002/0 50 10866644222110002/02/02/03/0 60 108664422110002/02/03/03/03/03/0 70 866442211002/02/03/03/03/03/04/04/0 80 86644221002/02/03/03/03/04/04/04/04/0 90 8644221002/02/03/03/04/04/04/04/04/0 100 664422102/02/03/03/04/04/04/0
10 15 20 25 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
24 Volts - 3% Drop Wire sizes (gauge) - Based on Minimum CM Area
3