Please read this instruction manual carefully before installation and
start-up, and store it in a safe place. If you pass on the device to another
person, hand over this instruction manual along with it.
DANGER!
Safety instruction: Indicates a hazardous situation that, if not avoided, will
D
!
!
result in death or serious injury.
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided, could
result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
A
NOTE
Supplementary information for operating the product.
I
3
AU
Safety and installation instructionsIBIS4
2Safety and installation instructions
Please observe the prescribed safety instructions and stipulations from
the vehicle manufacturer and service workshops.
The manufacturer accepts no liability for damage in the following cases:
•
Faulty assembly or connection
•
Damage to the product resulting from mechanical influences and incorrect
connection voltage
•
Alterations to the product without express permission from the manufacturer
•
Use for purposes other than those described in the operating manual
2.1Handling the device
WARNING!
•
Installation and repair of the roof air conditioner may only be carried out by
!
qualified personnel who are familiar with the risks involved and the relevant
regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back
page).
!
•
Electrical devices are not toys.
Keep electrical devices out of reach of children or infirm persons. Do not
allow them to use electrical devices without supervision.
•
Persons whose physical, sensory or mental capabilities or whose lack of
experience and knowledge prevent them from using the device safely
should not use it without supervision or instruction by a responsible person.
•
Do not undo the upper cover of the roof air conditioner in the event of a fire.
Use approved extinguishing agents instead. Do not use water to extinguish
fires.
CAUTION!
•
The roof air conditioner must be installed securely so that it cannot fall down.
•
Only operate the roof air conditioner if you are certain that the housing and
the cables are not damaged.
•
Do not use the roof air conditioner near flammable fluids or in closed rooms.
•
Make sure no combustible objects are stored or installed near the air outlet.
A distance of at least 50 cm must be kept.
•
Do not reach into air outlets or insert any foreign objects in the device.
A
4
NOTICE!
•
Only use the device as intended.
•
The roof air conditioner is not suitable for use in agricultural or construction
vehicles.
AU
IBIS4Target group for this instruction manual
•
Do not make any alterations or conversions to the device.
•
Never drive through automatic car washes when the roof air conditioner is
mounted.
•
If faults occur in the refrigerant circuit, the system must be checked by a specialist company and repaired properly. The refrigerant must never be
released into the air.
NOTE
•
Please ask your vehicle manufacturer if a technical inspection is required after
I
fitting an air conditioner and whether the height entered in the vehicle documents needs to be altered:
–IBIS4: increased height 230 mm
2.2Handling electrical cables
WARNING!
•
The electrical power supply may only be connected by a qualified electrician.
!
•
The appliance shall be installed in accordance with national wiring regulations.
CAUTION!
•
Attach and lay the cables so that they cannot be tripped over or damaged.
!
NOTICE!
•
Use cable ducts to lay cables through walls with sharp edges.
A
3Target group for this instruction manual
•
Do not lay loose or bent cables next to electrically conductive materials
(metal).
•
Do not pull on the cables.
The instructions in this manual are intended for qualified personnel at workshops
who are familiar with the guidelines and safety precautions to be applied.
5
AU
Scope of deliveryIBIS4
1
2
3
4
5
6
7
8
1
4Scope of delivery
No. in
fig. 1
11Roof air conditioner
21Roof plate
31Air distribution box (ADB)
41ADB centre cover
55Duct sections
63Cable connectors
74Long fastening bolts
81Remote control (with batteries)
Quantity Description
5Accessories
Available as accessories (not included in the scope of delivery):
Description
Duct sectionAdditional duct sections to allow fitment to thicker roof
6
AU
IBIS4Intended use
2
3
ADB data label
inside the ADB
centre cover
6Intended use
The IBIS4 air conditioner is designed for installation on the roof of a caravan or
recreational vehicle to provide reverse cycle heating and cooling. The device is
intended for vehicles with roofs that are from 20 to 100 mm thick. The device
must be installed so that it is within ±10° of the horizontal plane. It is not suitable
for houses and apartments.
The roof air conditioner is not suitable for installation in construction machines,
agricultural machines or similar equipment. It will not work properly if exposed
to strong vibrations.
The function of the roof air conditioner is guaranteed for temperatures between
–2 °C and 52 °C.
NOTE
You can find additional information on roof air conditioners in the operating
I
manual, such as the technical description or the controls.
7Labels
Product data label location
on rooop unit
Labels are attached to the IBIS4 roof air conditioners. These labels provide the
user and fitter with information on specifications of the device.
The roof air conditioner label is located on the side of the electronics box and can
be seen through the side vent. The ADB label is located inside the centre cover.
7
AU
InstallationIBIS4
8Installation
CAUTION! Beware of injury
The roof air conditioner may only be installed by qualified personnel. The fol-
!
lowing information is intended for technicians who are familiar with the guidelines and safety precautions to be applied.
8.1Note on installation
Read this installation manual completely before installing the roof air conditioner.
The following tips and instructions must be observed while installing the roof air
conditioner:
DANGER! Danger of electrocution
Disconnect all power supplies when working on the roof air conditioner.
D
!
A
CAUTION! Beware of injury
•
Improper installation of the roof air conditioner can result in irreparable
damage to the device and put the safety of the user at risk.
•
The manufacturer assumes no liability for malfunctions and for the safety of
the roof air conditioner, especially for injury and/or damage to property, if
the roof air conditioner is not fitted in accordance with these installation
instructions.
•
Always wear the recommended protective clothing (e.g. protective goggles, gloves).
NOTICE! Beware of damage
•
Observe the structural engineering of the vehicle and seal of all openings
made when installing the roof air conditioner.
•
Check whether the roof of the vehicle is able to support the weight of a person before climbing onto it. Ask the vehicle manufacturer about the permissible roof loads.