Please read this instruction manual carefully before first use, and store it in
a safe place. If you pass on the product to another person, hand over this
instruction manual along with it.
You find the installation manual online at:
“dometic.com/manuals”.
The instructions in the installation manual are intended for qualified
personnel at workshops who are familiar with the guidelines and
safety precautions to be applied.
Safety instruction: Failure to observe this instruction can cause death
or serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
A
I
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
2Safety instructions
The manufacturer accepts no liability for damage in the following cases:
•
Damage to the product resulting from mechanical influences and incorrect
connection voltage
•
Alterations to the product without express permission from the manufacturer
•
Use for purposes other than those described in the operating manual
4
a
AU
IBIS4Safety instructions
In particular, the manufacturer will not be liable for any consequential damage,
especially consequential damage caused by failure of the roof air conditioner.
2.1General safety
WARNING!
•
!
Electrical devices are not toys.
The appliance is not to be used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they are under supervision or have been given
instruction.
•
Children should be supervised to ensure that they do not play with the
appliance.
•
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they are under supervision or
have been given instruction concerning use of the appliance in a safe
way and understand the hazards involved.
•
Children shall not play with the appliance.
•
Cleaning and user maintenance shall not be performed by children
without supervision.
•
Only use the device as intended.
•
Do not make any alterations or conversions to the device.
•
Installation, maintenance and repairs of the roof air conditioner may
only be carried out by qualified personnel who are familiar with the
risks involved when handling refrigerant and air conditioning systems
as well as the relevant regulations. Inadequate repairs may cause
serious hazards. For repair service, please contact the service centre in
your country (addresses on the back page).
•
Do not use the device near flammable fluids or in closed rooms.
•
Make sure no combustible objects are stored or installed near the air
outlet. A distance of at least 50 cm must be kept.
•
Do not reach into air outlets or insert any foreign objects in the roof air
conditioner.
•
Do not undo the upper cover of the roof air conditioner in the event of
a fire. Use approved extinguishing agents instead. Do not use water to
extinguish fires.
5
AU
Target group for this manualIBIS4
NOTICE!
•
A
Never drive through automatic car washes when the roof air
conditioner is mounted.
•
Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height entered
in your vehicle documents needs to be altered.
•
If faults occur in the roof air conditioner's refrigerant circuit, the roof air
conditioner must be checked by a specialist company and properly
repaired. The refrigerant must never be released into the air.
2.2Operating the device safely
WARNING!
•
!
A
Always disconnect the power supply when working on the device.
NOTICE!
•
The roof air conditioner is not suitable for use in agricultural or
construction vehicles.
•
Operate the device only if you are certain that the housing and the
cables are undamaged.
3Target group for this manual
This operating manual is for the user of the roof air conditioner.
4Intended use
The Harrier Lite roof air conditioner is designed for installation on the roof of a
caravan or recreational vehicle to provide reverse cycle heating and cooling. It is
intended for vehicles with roofs with a thickness of 20 to 100 mm. The roof air
onditioner must be installed so that it is within ±10° of the horizontal plane. It is not
suitable for houses and apartments.
The roof air conditioner is not suitable for installation in construction machines,
agricultural machines or similar equipment. It will not work properly if exposed to
strong vibrations.
The function of the roof air conditioner is guaranteed for temperatures between
–2 °C and 52 °C.
a
6
AU
IBIS4Technical description
1
5Technical description
The roof air conditioner supplies the interior with cool or warm air which is without
dust and dirt and can be dehumidified.
The roof air conditioner is operated with the remote control or via the control panel
on the air conditioner.
NOTE
I
5.1Control panel
The roof air conditioner can lower the temperature within the vehicle to
a certain level. The temperature depends on the type of vehicle, the
ambient temperature and the cooling capacity of your roof air
conditioner.
Below an outer temperature of 16 °C the roof air conditioner doesn’t
cool anymore. In this case only use the air conditioning mode
“Ventilation” ().
1
The control panel (1) is at the air outlet unit of the roof air conditioner.
7
AU
Technical descriptionIBIS4
AUTO
2
Control and display elements (fig. 2):
SymbolExplanation
Switches the roof air conditioner on or to stand-by mode.
+ button: Increases the currently displayed value.
– button: Reduces the currently displayed value.
Activates the sleep function (chapter “Additional functions” on page 11).
Indicates the timer is set.
Displays the set temperature and indicates fan level when fan is adjusted.
Enables/disables automatic mode (chapter “Air conditioning modes” on
page 10).
Enables/disables cooling mode (chapter “Air conditioning modes” on
page 10).
Enables/disables heating mode (chapter “Air conditioning modes” on
page 10).
Adjusts the fan speed between Low, Med or High – showing as 1, 2 or 3 on
the air outlet unit display for a short time when changed.
Enables/disables ventilation mode (chapter “Air conditioning modes” on
page 10). Circulates air without heating or cooling.
Enables/disables dehumidification mode (chapter “Air conditioning
modes” on page 10).
a
8
AU
TURBO
°C/°F
1
3
IBIS4Technical description
5.2Remote control
All settings of the device (e. g. temperature settings, timer programming) are
transmitted to the roof air conditioner by remote control.
The following control and display elements are available on the remote control
(fig. 3, page 9) :
No./ButtonExplanation
1Display
Displays the following:
•
Time
•
Selected room temperature (target value) in °C or °F
•
Actual room temperature
•
Air conditioning mode
•
Fan level
•
Symbols for active additional functions
•
Battery status
9
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.