Dometic Freshwell 3000, FW3000 Operating Manual

AIR CONDITIONERS

FRESHWELL

FW3000

 

EN

Under-bench air conditioner

 

 

Operating manual . . . . . . . . . . . . . . . . . . .

. . 6

DE

Staukastenklimaanlage

 

 

Bedienungsanleitung . . . . . . . . . . . . . . . .

.30

 

Climatiseur de coffre

 

FR

 

 

 

Notice d’utilisation . . . . . . . . . . . . . . . . . .

.55

 

Equipo de aire acondicionado de

ES

 

 

 

cajón

 

 

Instrucciones de uso . . . . . . . . . . . . . . . . .

.79

 

Sistema de climatização para caixa

PT

 

 

 

de arrumação

 

 

Manual de instruções . . . . . . . . . . . . . . . .

104

 

Climatizzatore per vano di carico

IT

 

 

 

Istruzioni per l’uso . . . . . . . . . . . . . . . . . . .

131

NL

Airco onder de bank

 

 

Gebruiksaanwijzing. . . . . . . . . . . . . . . . . .

156

DA

Klimaanlæg til montering i et

 

 

magasin

 

SV

NO

FI

RU

PL

SK

CS

HU

Klimatanläggning för förvaringsutrymmen

Bruksanvisning . . . . . . . . . . . . . . . . . . . . . 204

Takboksklimaanlegg

Bruksanvisning . . . . . . . . . . . . . . . . . . . . . 226

Kaappi-ilmastointilaite

Käyttöohje . . . . . . . . . . . . . . . . . . . . . . . . . 249

Встраиваемый в багажный ящик кондиционер

Инструкция по эксплуатации . . . . . . . . . 272

Klimatyzator umieszczany w schowku

Instrukcja obsługi . . . . . . . . . . . . . . . . . . . 297

Klimatizačné zariadenie do úložného priestoru

Návod na obsluhu . . . . . . . . . . . . . . . . . . . 321

Klimatizace do zavazadlového prostoru

Návod k obsluze . . . . . . . . . . . . . . . . . . . . 345

Tárolóládás klímaberendezés

Használati utasítás. . . . . . . . . . . . . . . . . . . 368

Betjeningsvejledning . . . . . . . . . . . . . . . . 180

FreshWell3000

1

2

5

1

6

9

7

4

 

10

 

8

 

 

 

4

3

 

 

2

4

5

 

1

3

2

 

2

FreshWell3000

3

1

15

14

 

13

2

12

3

11

4 10

5

9

6

8

7

 

4

1

2

3

Dometic Freshwell 3000, FW3000 Operating Manual

 

FreshWell3000

5

 

 

1.

 

2.

 

3.

 

1

 

2

 

5.

 

4.

6

 

400

628

<![if ! IE]>

<![endif]>286

 

4

FreshWell3000

7

5

FreshWell3000

Original instructions

Please read this instruction manual carefully before first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it.

You find the installation manual online at: “dometic.com/manuals”.

The instructions in the installation manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied.

Table of contents

1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

4 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

5 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

6 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 6.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 6.4 Air conditioning modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 6.5 Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

7 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

8 Operating the under-bench air conditioner. . . . . . . . . . . . . . . . . . . . .17 8.1 Basic notes on operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 8.2 Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 8.3 Hint for improved use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 8.4 Switching the under-bench air conditioner on and off . . . . . . . . . . .18 8.5 Selecting the air conditioning mode . . . . . . . . . . . . . . . . . . . . . . . . .18 8.6 Selecting the blower setting manually . . . . . . . . . . . . . . . . . . . . . . . .19 8.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 8.8 Setting the timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

6

EN

 

FreshWell3000

Explanation of symbols

 

8.9 Activating the Sleep function . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

22

 

8.10

Replacing the remote control batteries . . . . . .

. . . . . . . . . . . . . . . .

22

 

8.11

Setting the time . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

23

9

Cleaning the under-bench air conditioner . . . . .

. . . . . . . . . . . . . . . .

23

10

Maintenance of the under-bench air conditioner . . . . . . . . . . . . . . .

24

11

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

25

12

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

27

13

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

27

14

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

29

1Explanation of symbols

!WARNING!

Safety instruction: Failure to observe this instruction can cause fatal or serious injury.

!CAUTION!

Safety instruction: Failure to observe this instruction can lead to injury.

ANOTICE!

Failure to observe this instruction can cause material damage and impair the function of the product.

INOTE

Supplementary information for operating the product.

2Safety instructions

The manufacturer accepts no liability for damage in the following cases:

Damage to the product resulting from mechanical influences and incorrect connection voltage

Alterations to the product without express permission from the manufacturer

Use for purposes other than those described in the operating manual

EN

7

 

 

 

Safety instructions

FreshWell3000

In particular, the manufacturer will not be liable for any consequential damage, especially consequential damage caused by failure of the under-bench air conditioner.

Note the following basic safety information when using electrical devices to protect against:

Electric shock

Fire hazards

Injury

2.1General safety

!WARNING!

Electrical devices are not toys.

Keep electrical devices out of reach of children or infirm persons. Do not allow them to use electrical devices without supervision.

This device can be used by children aged 8 years or over, as well as by persons with diminished physical, sensory or mental capacities or a lack of experience and/or knowledge, providing they are supervised or have been taught how to use the device safely and are aware of the resulting risks.

Cleaning and user maintenance must not be carried out by children without supervision.

Children must not play with the device.

Children must be supervised to ensure that they do not play with the device.

Always keep and use the device out of the reach of children under the age of 8 years.

Only use the device as intended.

Do not make any alterations or conversions to the device.

Installation, maintenance and repairs of the under-bench air conditioner must only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).

Do not use the under-bench air conditioner near flammable fluids.

8

EN

 

FreshWell3000

Target group for this manual

Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept.

Do not reach into air outlets or insert any foreign objects in the underbench air conditioner.

Do not undo the upper cover of the under-bench air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.

A damaged supply cord must be replaced by the manufacturer or a qualified person in order to avoid a hazard.

ANOTICE!

If faults occur in the under-bench air conditioner's refrigerant circuit, the under-bench air conditioner must be checked by a specialist company and properly repaired. The refrigerant must never be released into the air.

Do not apply heavy objects or pressure on the device.

2.2Operating the device safely

!WARNING!

Always disconnect the power supply when working on the device.

!CAUTION!

Do not touch the device during operation. The device contains hot and cold components, moving parts and electrical items which may cause injury.

ANOTICE!

The under-bench air conditioner is not suitable for use in agricultural or construction vehicles.

Operate the device only if you are certain that the housing and the cables are undamaged.

3Target group for this manual

This operating manual is for the user of the under-bench air conditioner.

EN

9

 

 

 

Scope of delivery

FreshWell3000

4Scope of delivery

Dometic FreshWell under-bench air conditioner

Operating manual

5Intended use

The Dometic FreshWell3000 under-bench air conditioner is designed for use in motorcaravans, caravans and other vehicles with habitation compartments only. It is not suitable for houses and appartments.

The under-bench air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work properly if exposed to strong vibrations.

The operating mode of FreshWell3000 is guaranteed for temperatures between 0 °C and 52 °C.

6Technical description

The under-bench air conditioner supplies the interior with cool dehumidified air without dust and dirt.

The under-bench air conditioner is operated with the remote control.

INOTE

The under-bench air conditioner can lower the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your under-bench air conditioner.

Below an outer temperature of 16 °C the under-bench air conditioner doesn’t cool anymore. In this case only use the air conditioning mode “Circulating air” ().

10

EN

 

FreshWell3000

Technical description

6.1Components

The refrigerant circuit of the under-bench air conditioner consists of the following main components (fig. 1, page 2):

Compressor (1)

The compressor draws in the refrigerant used and compresses it. This raises the pressure and therefore the temperature of the refrigerant.

Condenser (2)

The built-in liquefier works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid.

Evaporator (3)

The evaporators cool down and dehumidify the air flowing past them. The refrigerant absorbs the heat and vaporises.

Blower (4)

A blower distributes the cooled or heated air within the vehicle through an air outlet unit.

4-way valve (5)

The 4-way valve reverses the cooling circuit. Thus the internal register of the evaporator becomes a condenser and heats the air passing through.

Electric heating element (6)

The electric heating element increases the heating effect when the outer temperature is low.

Air inlet (7), air outlet (8) for external heat exchanger

Air is sucked into the device through the air inlet and escapes through the air outlet.

Air inlet (9), air outlet (10) for internal heat exchanger

Air is sucked into the device through the air inlet and escapes through the air outlet. The internal heat exchanger treats the air in order to be cold or hot depending on active mode.

EN

11

 

 

 

Technical description

FreshWell3000

6.2Receiver

The receiver (fig. 2, page 2) contains the following control and display elements:

No. Explanation

1

Digital display

Displays the room temperature.

2Red/green LED Constantly lit, red: the stand-by mode is active

 

 

Constantly lit, green: any other mode is active

 

 

Flashing, red/green: the under-bench air conditioner is on,

 

 

but the supply voltage is not present

 

 

 

3

Blue LED

Constantly lit: the cooling mode is active

 

 

Flashing: the dehumidification mode is active

 

 

Off: any other mode is active

 

 

 

4

Orange LED

Constantly lit: the heating mode is active

 

 

Flashing: the heating mode is active, but the air conditioner is

 

 

not yet producing hot air, because the defrost function or the

 

 

preventing cold air function is active

 

 

The defrost function prevents ice on the external battery

 

 

exchanger while in heating mode.

 

 

The preventing cold air function prevents that cold air is blown

 

 

into the vehicle while in heating mode.

 

 

Off: any other mode is active

 

 

 

5

Yellow LED

Constantly lit: the timer mode is active

 

 

Off: the timer mode is not active

 

 

 

In case of an alarm the display shows an error code to identify the fault:

Code Explanation

E1 Room temperature probe fault

E2 Indoor battery temperature probe fault

E3 Outdoor battery temperature probe fault

E4 Control card communication fault (control card failure)

12

EN

 

FreshWell3000

Technical description

6.3Remote control

All settings of the device (e. g. temperature settings, timer programming) are transmitted to the under-bench air conditioner by remote control.

The following control and display elements are available on the remote control (fig. 3, page 3) :

No. Explanation

1Digital display: Displays the following:

Time

Selected room temperature (target value) in °C or °F

Actual room temperature

Air conditioning mode

Blower level

Symbols for active additional functions

Battery status

2button:

Switches the air conditioner and remote control on or to stand-by mode

3 button:

Selects the blower setting

4MODE button:

Selects the air conditioning mode

5 button:

Activates the sleep function. The sleep function automatically modifies the target value to provide a pleasant sleeping temperature.

6 button:

Press once:

Displays the current interior temperature (symbol

is dis-

 

played).

 

Press again:

Displays the set temperature.

 

7 button:

No function assigned yet

8°C/°F button:

Switches between temperature units Celsius (°C) and Fahrenheit (°F).

9 button:

Sets the timer and the clock.

EN

13

 

 

 

Technical description

FreshWell3000

No. Explanation

10SET button:

Confirms and saves settings.

11 button:

No function assigned yet

12+ button: Increases the value

13button: Reduces the value

14Symbol (batteries empty)

Is displayed when the batteries in the remote control are empty. If this happens, replace the batteries, see chapter “Replacing the remote control batteries” on page 22.

15Symbol (transmitting values)

Is displayed briefly when the remote control is transmitting values to the underbench air conditioner.

6.4Air conditioning modes

The under-bench air conditioner has the following air conditioning modes:

Air conditioning

Display

Explanation

mode

message

 

 

 

 

Automatic

 

In this mode the air conditioner sets the temperature

 

 

(set point) automatically and manages the compressor,

 

 

heat pump and fan speed by comparing the set point

 

 

with the room temperature and it sets the

 

 

corresponding conditioning mode (see following

 

 

table).

 

 

The , + and buttons are deactivated in this mode.

 

 

 

Cooling

 

You specify the temperature and blower settings, and

 

 

the air conditioner cools the interior to this tempera-

 

 

ture.

 

 

 

Heating

 

You specify the temperature and blower settings, and

 

 

the air conditioner heats the interior to this tempera-

 

 

ture.

 

 

 

14

EN

 

FreshWell3000

 

 

 

Technical description

 

 

 

 

 

Air conditioning

Display

Explanation

 

mode

message

 

 

 

 

 

 

 

Circulating air

 

You specify the blower level, and the air conditioner

 

 

blows air into the interior.

 

 

 

 

Dehumidification

 

You specify the temperature, and the air conditioner

 

 

cools the interior to this temperature and controls the

 

 

necessary blower output and dehumidifys the interior

 

 

(Circulating air mode).

 

 

 

The

button is deactivated in this mode.

 

 

 

 

 

 

 

 

 

 

Current room

ϑ ≤ 20 °C

22 °C < ϑ < 25 °C

ϑ ≥ 25 °C

temperature ϑ

 

 

 

 

 

 

 

 

 

Set point:

20 °C

 

22 °C

25 °C

 

 

 

 

Conditioning

Heating or

Dehumidification or

Cooling

mode:

Circulating air

Circulating air

 

 

 

 

 

 

6.5Additional functions

The under-bench air conditioner has the following additional functions:

Additional

Display

Explanation

function

message

 

 

 

 

Timer

 

The air conditioner is switched on at the specified

 

 

time.

 

 

 

 

 

The air conditioner is switched off at the specified

 

 

time.

 

 

 

 

 

The air conditioner is switched on and off at the

 

 

specified times.

 

 

 

Sleep

 

The set temperature is modified by 1 °C after one hour

 

 

and by 2 °C after two hours to generate a pleasant

 

 

temperature for sleeping.

 

 

 

EN

15

 

 

 

Before initial use

FreshWell3000

7Before initial use

Inspection before starting up

Before you switch on the under-bench air conditioner, observe the following:

Check whether the supply voltage and frequency correspond to the values specified in the technical data, see page 29.

Ensure both the air intake opening and the air nozzles are free. All ventilation grilles must always be kept free to ensure that the under-bench air conditioner is able to operate at maximum capacity.

!CAUTION! Beware of injury

Do not insert your fingers or objects into the air nozzles or the intake grille.

Setting the time

Set the current time: see chapter “Setting the time” on page 23.

Set the remote control

Insert the batteries (see chapter “Replacing the remote control batteries” on page 22).

The display shows all symbols for 5 seconds.

Press simultaneously the button and the button during this 5 seconds.

The display shows the default model number.

Press simultaneously + and button within 3 seconds to select the model number:

FreshWell3000: 02

FreshJet: 07

FreshLight: 11

The display shows all symbols for 5 seconds.

The remote control is ready for operation.

16

EN

 

FreshWell3000

Operating the under-bench air conditioner

8Operating the under-bench air conditioner

8.1Basic notes on operation

The under-bench air conditioner has three operating modes:

Operating mode

Features

 

 

Stand-by

The under-bench air conditioner is ready for operation and can be

 

switched on with the remote control.

 

 

On

The under-bench air conditioner is conditioning the air in the interior.

 

 

The receiver switches on when it receives pulses from the remote control. The display shows (flashing) the temperature setting, after 10 seconds the display shows the room temperature, then it switches off.

You can use the remote control to

switch the under-bench air conditioner to and from stand-by mode.

adjust the settings

select additional functions

8.2Using the remote control

The remote control must be pointed at the IR receiver (fig. 2 4, page 2) on the receiver during operation.

When a button is pressed, the value is transmitted directly to the under-bench air conditioner. The under-bench air conditioner confirms the receipt of data with a high note.

Switching only the remote control to or from stand-by

In stand-by mode, the remote control display shows only the time.

If the remote control is not pointing to the IR receiver (fig. 2 4, page 2) on the control panel, you can activate the remote control or switch it to stand-by independently from the under-bench air conditioner:

Press the button.

EN

17

 

 

 

Operating the under-bench air conditioner

FreshWell3000

8.3Hint for improved use

The following hints will optimise the performance of your under-bench air conditioner:

Improve the heat insulation of your vehicle by sealing gaps and hanging reflective blinds or curtains on your windows.

If the vehicle has been subjected to direct sunlight for a long time: Operate the

under-bench air conditioner in the “Circulating air” () mode with the windows open for a while before switching on the “Cooling” () air conditioning mode.

Avoid opening doors and windows as far as possible in the “Cooling” () mode.

Select an appropriate temperature and blower speed.

Align the air nozzles sensibly.

Make sure the air nozzles and intake grille are not covered by cloths, paper or other objects.

Clean the air filter periodically.

8.4Switching the under-bench air conditioner on and off

INOTE

When it is switched on, it begins to condition the air to the values that were set most recently.

You can use the remote control to switch the under-bench air conditioner to and from stand-by mode. Press thebutton.

You can operate the under-bench by remote control and via LIN bus. If you use LIN bus control the receiver is not required.

Don‘t use the under-bench air conditioner if the vehicle is tilted more than 10°.

When you switch on the under-bench air conditioner, the device waits a few minutes before operating the compressor.

8.5Selecting the air conditioning mode

INOTE

The under-bench air conditioner must be switched on.

Select the air conditioning mode of your choice using the MODE key, see chapter “Air conditioning modes” on page 14.

18

EN

 

FreshWell3000

Operating the under-bench air conditioner

The under-bench air conditioner confirms the receipt of the values with a high note.

The under-bench air conditioner is switched to the selected air conditioning mode.

8.6Selecting the blower setting manually

INOTE

The under-bench air conditioner must be switched on.

The blower controls the strength of the air supply.

In the “Cooling” () and “Circulating air” () modes, the blower levels can be selected manually. In the other air conditioning modes, the under-bench air conditioner controls the blower level automatically.

Display message

Explanation

 

Low blower level

 

Medium blower level

 

High blower level

 

not available in the “Cooling” ( ) mode

 

Automatic mode, only available in the “Cooling” ( ), “Heating”

 

( ) and “Dehumidifying” ( ) modes.

Use the button to select the desired blower level.

The under-bench air conditioner confirms the receipt of the values with a high note.

The new blower level has been set.

8.7Setting the temperature

INOTE

The under-bench air conditioner must be switched on.

EN

19

 

 

 

Operating the under-bench air conditioner

FreshWell3000

Cooling Mode

In the “Cooling” (), and “Dehumidifying” () modes, you can specify a temperature between 16 °C and 31 °C via the remote control.

Use the + or button to select the desired temperature.

The under-bench air conditioner confirms the receipt of the values with a high note.

The temperature is set on the under-bench air conditioner.

Heating Mode

In the “Heating” () mode, you can specify a temperature between 16 °C and 31 °C via the remote control.

Use the + or button to select the desired temperature.

The under-bench air conditioner confirms the receipt of the values with a high note.

The temperature is set on the under-bench air conditioner.

8.8Setting the timer

The timer function allows you to set a specific time period for air conditioning. You can specify the switch-on time, the switch-off time or both values.

INOTE

The remote control returns to its initial mode if no button is pressed on the remote control for 15 seconds while programming the timer.

Before programming the timer, select the air conditioning mode and all required values (e.g. temperature).

Setting the switch-on time

INOTE

The under-bench air conditioner must be switched off.

Press the button once.

The ON symbol () flashes on the display of the remote control.

Use the + or button to set the time when the under-bench air conditioner is to switch on.

20

EN

 

FreshWell3000 Operating the under-bench air conditioner

Press the SET button to transmit the value to the under-bench air conditioner.

The switch-on time is set on the under-bench air conditioner.

The under-bench air conditioner is switched on with the selected air conditioning mode at the specified time.

Switch the under-bench air conditioner to stand-by.

Setting the switch-off time

INOTE

The under-bench air conditioner must be switched on.

Press the button twice.

The OFF symbol () flashes on the display of the remote control.

Use the + or button to set the time when the under-bench air conditioner is to switch off.

Press the SET button to transmit the value to the under-bench air conditioner.

The switch-off time is set on the under-bench air conditioner.

The under-bench air conditioner runs in the selected air conditioning mode until the specified time.

Setting the switch-on and switch-off times

Press the button three times.

The ON symbol () flashes on the display of the remote control. The OFF symbol () is displayed.

Use the + or button to set the time when the under-bench air conditioner is to switch on.

Press the button again.

The OFF symbol () flashes on the display of the remote control.

Use the + or button to set the time when the under-bench air conditioner is to switch off.

Press the SET button to transmit the value to the under-bench air conditioner.

The switch-on and switch-off times are set on the under-bench air conditioner. The under-bench air conditioner starts in the selected air conditioning mode at the specified time and runs until the second specified time.

Switch the under-bench air conditioner to stand-by.

EN

21

 

 

 

Operating the under-bench air conditioner

FreshWell3000

Cancelling timer settings

If you have set the timer, you can cancel these settings as follows:

Press the button four times.

The timer symbol disappears.

The setting has been cancelled.

8.9Activating the Sleep function

INOTE

The sleep function is deactivated in “Circulating air” () and the “Dehumidifying” () modes.

When the sleep function is activated, the set temperature is modified by 1 °C after one hour and by 2 °C after two hours to ensure a pleasant temperature for sleeping.

Set the required temperature (see chapter “Setting the temperature” on page 19).

Press the button.

The symbol appears in the display. The sleep function is activated.

To deactivate the sleep function press the button again.

INOTE

The sleep function is deactivated if the MODE button is pressed.

8.10Replacing the remote control batteries

Replace the batteries if you see the symbol on the display.

The battery compartment is on the back of the remote control.

Gently push down the lid of the battery compartment and slide it open in the direction of the arrow.

Insert the new batteries (2x type AAA) in the remote control as indicated in the battery compartment.

Close the cover of the battery compartment.

22

EN

 

FreshWell3000

Cleaning the under-bench air conditioner

BProtect the environment!

Do not dispose of any batteries with general household waste.

Return defective or used batteries to your retailer or dispose of them at collection points.

8.11Setting the time

The remote control needs the current time in order to program the timer. The time is indicated on the display of the remote control.

Perform the following steps to set the time:

INOTE

The remote control returns to its initial mode and saves the current setting, if no key is pressed on the remote control for 15 seconds while setting the time.

Press and hold the button in order to get into the mode for setting the time.

The time flashes on the display of the remote control.

Use the + or button to set the current time.

Press the + or button longer than 2 s to increase or decrease the time quicker.

Press the SET button to confirm the time.

9Cleaning the under-bench air conditioner

ANOTICE! Beware of damage

Do not clean the under-bench air conditioner with a high-pressure cleaner. Exposure to water can damage the air conditioner.

Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the under-bench air conditioner.

To clean the under-bench air conditioner, use water with a gentle cleaning agent. Never use petrol, diesel or solvents.

Clean the housing of the under-bench air conditioner and the air outlet unit occasionally with a damp cloth.

Regularly remove leaves and other dirt from the ventilation grilles (fig. 4 1, page 3) of the under-bench air conditioner. Make sure you do not damage the grilles in the process.

EN

23

 

 

 

Maintenance of the under-bench air conditioner

FreshWell3000

Clean the remote control with a slightly damp cloth from time to time. We recommend using a cleaning cloth for glasses to clean the display.

10Maintenance of the under-bench air conditioner

!WARNING!

Any other maintenance work to that which is described here may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations.

Interval

Inspection/maintenance

 

 

Regularly

Check the condensation water drainage:

 

Check whether the condensation water drainage channels

 

(fig. 42, page 3) at the sides of the under-bench air conditioner

 

are clear and the condensation water is able to escape.

 

 

Regularly

Clean the filter of the air discharge unit (fig. 5, page 4):

 

Pull the filter (1) out of the fastening.

 

Clean the filter (1) with a detergent solution and let it dry.

 

Put the dry filter (1) back in.

 

 

Once per year

Have the heat exchanger serviced:

 

Have the heat exchanger of the under-bench air conditioner

 

serviced by specialist workshop.

 

 

Once per year

Replace the carbon filter (fig. 5, page 4) (optional):

 

Pull the filter (1) out of the fastening.

 

Remove the carbon filter (2).

 

Put a new carbon filter in.

 

or

 

Clean the filter (1) with a detergent solution and let it dry.

 

Put the dry filter (1) back in.

 

 

24

EN

 

FreshWell3000

 

Troubleshooting

11

Troubleshooting

 

 

 

 

 

Problem

 

Cause

Remedy

 

 

 

 

No cooling

 

The under-bench air conditioner is not

Set the under-bench air

capacity

 

set to cooling.

conditioner to cooling.

 

 

 

 

 

The ambient temperature is above 52 °C. The under-bench air conditioner is

 

 

 

only designed for ambient

 

 

 

temperatures of up to 52 °C.

 

 

 

 

 

 

The temperature set is higher than the

Select a lower temperature.

 

 

room temperature.

 

 

 

 

 

 

 

The ambient temperature is below 16 °C.

The under-bench air conditioner is

 

 

 

only designed for ambient

 

 

 

temperatures above 16 °C.

 

 

 

 

 

 

The thermal protection is defective.

Contact an authorised workshop.

 

 

 

 

 

 

The compressor is damaged.

 

 

 

 

 

 

 

The refrigerating agent filling is

 

 

 

insufficient.

 

 

 

 

 

 

 

The heat exchange coils are polluted.

 

 

 

 

 

 

 

The external blower is defective.

 

 

 

 

 

No heating

 

The under-bench air conditioner is not

Set the under-bench air

capacity

 

set to heating.

conditioner to heating.

 

 

 

 

 

 

The ambient temperature is below 0 °C.

The under-bench air conditioner is

 

 

 

only designed for ambient

 

 

 

temperatures higher than 0 °C.

 

 

 

 

 

 

The temperature set is lower than the

Select a higher temperature.

 

 

room temperature.

 

 

 

 

 

 

 

The ambient temperature is higher than

The temperature is adjustable

 

 

31 °C.

between 16 °C and 31 °C.

 

 

 

 

 

 

The thermal protection is defective.

Contact an authorised workshop.

 

 

 

 

 

 

The compressor is damaged.

 

 

 

 

 

 

 

The refrigerating agent filling is

 

 

 

insufficient.

 

 

 

 

 

 

 

The heat exchange coils are polluted.

 

 

 

 

 

 

 

The external blower is defective.

 

 

 

 

Low air output

The air filter is obstructed.

Clean the air filter.

 

 

 

 

 

 

The heat exchange coils are polluted.

Contact an authorised workshop.

 

 

 

 

 

 

The internal blower is defective.

 

 

 

 

 

EN

25

 

 

 

Troubleshooting

 

FreshWell3000

 

 

 

Problem

Cause

Remedy

 

 

 

Water enters the

The condensation water drainage open-

Clean the drainage openings for

vehicle

ings are clogged up.

condensation water.

 

 

 

 

The seals are damaged.

Contact an authorised workshop.

 

 

 

Under-bench air

No supply voltage (230 Vw) connected.

Check the power supply.

conditioner does

 

 

The voltage is too low (under 200 Vw).

Contact an authorised workshop.

not switch on.

The voltage converter is defective.

 

 

 

 

 

 

 

The defective thermal protection is

 

 

defective.

 

 

 

 

 

The electrical fuse of the power supply is

Check the electrical fuse of the

 

too low.

power supply.

 

 

 

Under-bench air

The air filter is obstructed.

Clean the air filter.

conditioner stops

 

 

The voltage is too low (under 200 Vw).

Contact an authorised workshop.

working.

The voltage converter is defective.

 

 

 

 

 

 

 

The defective thermal protection is

 

 

defective.

 

 

 

 

 

The condenser fan is damaged.

 

 

 

 

 

The heat exchange coils are polluted.

 

 

 

 

 

The external blower is defective.

 

 

 

 

Under-bench air

One of the temperature sensors is

Contact an authorised workshop.

conditioner does

defective.

 

not switch off.

 

 

 

 

 

26

EN

 

FreshWell3000

Warranty

12 Warranty

The statutory warranty period applies. If the product is defective, please contact the service partner in your country (addresses on the back on the instruction manual).

Our experts will be happy to help you and will discuss the warranty process with you in more detail.

13 Disposal

Regulations for environmental safety and correct disposal

All organisations must apply a set of procedures to identify, evaluate and control the influence that their activities (manufacturing, products, services, etc.) have on the environment.

The procedures to be followed to identify significant environmental impact must take the following factors into account:

use of raw materials and natural resources

atmospheric emissions

discharge of liquids

waste management and recycling

contamination of the soil

In order to minimise environmental impact, the manufacturer provides a series of indications here below that should be taken into account by all those who, for whatever reason, interact with the appliance during its working life.

All packing components must be disposed of (preferably recycled) in compliance with statutory legislation in the country in which disposal takes place.

All product components must be disposed of (preferably recycled) in compliance with statutory legislation in the country in which disposal takes place.

For correct disposal, the appliance must be consigned to an authorised waste disposal company to ensure that all recyclable components are reused and the remaining materials are processed properly.

During installation ensure the room has adequate ventilation to prevent the buildup of stale air that might be harmful to the health of the operators.

During operation and maintenance ensure that any waste pollutant products (oil, grease, etc.) are disposed of correctly.

Keep noise levels down to reduce noise pollution.

EN

27

 

 

 

Disposal

FreshWell3000

For more information on correct dismantling of our products please refer to the recycling handbooks at dometic.com.

Place the packaging material in the appropriate recycling waste bins wherever possible.

When in operation or undergoing repairs and maintenance work, make sure that the refrigerant circuit is not damaged and refrigerant cannot escape. It acts as a greenhouse gas and should not be allowed into the environment.

MIf you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.

Dispose of the product at an official waste disposal facility in accordance with the applicable recycling or disposal guidelines.

BProtect the environment!

Do not dispose of any batteries with general household waste.

Return defective or used batteries to your retailer or dispose of them at collection points.

28

EN

 

FreshWell3000

Technical data

14

Technical data

 

 

 

 

 

 

FreshWell3000

 

 

Cooling capacity according to ISO 5151:

2700 W

 

 

Heating capacity:

3000 W

 

 

(2500 W + 500 W additional

 

 

heating element)

 

 

Rated input voltage:

220 – 240 Vw, 50/60 Hz

 

 

Current consumption:

Cooling (50/60 Hz): 5.1/6.2 A

 

 

Heating (50/60 Hz): 4.6/4.8 A

 

 

Required fuse:

5 A

 

 

Operating temperature range:

0 °C to +52 °C

 

 

Noise emission:

< 70 dB

 

 

Refrigerant:

R-410A

 

 

Refrigerant quantity:

0.6 kg

 

 

CO2 equivalent:

1.2528 t

 

 

Global warming potential (GWP):

2088

 

 

Additional heating element:

500 W

 

 

 

Blower:

 

3 blower levels

 

 

1 automatic mode

 

 

Protection class:

IP X5

 

 

Max. volume of space in the vehicle

30 m³

(with insulated walls):

 

 

 

Dimensions L x W x H:

fig. 6, page 4

 

 

 

Weight:

 

approx. 21 kg

 

 

Inspection/certification:

 

 

 

 

Contains fluorinated greenhouse gases

Hermetically sealed equipment

EN

29

 

 

 

FreshWell3000

Original-Betriebsanleitung

Bitte lesen Sie diese Anleitung vor der Inbetriebnahme sorgfältig durch und bewahren Sie sie auf. Geben Sie sie im Falle einer Weitergabe des Produktes an den Nutzer weiter.

Sie finden die Montageanleitung online auf: „dometic.com/manuals“.

Die Anweisungen in der Montageanleitung sind für Fachpersonal in Werkstätten vorgesehen, die mit den Richtlinien und den anzuwendenden Schutzmaßnahmen vertraut sind.

Inhaltsverzeichnis

1

Erklärung der Symbole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.31

2

Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.31

 

2.1

Grundlegende Sicherheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

 

2.2

Sicherheit beim Betrieb des Gerätes . . . . . . . . . . . . . . . . . . . . . . . .

33

3

Zielgruppe dieser Anleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

4

Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

5

Bestimmungsgemäßer Gebrauch. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

6

Technische Beschreibung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

 

6.1

Komponenten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

 

6.2

Empfänger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

 

6.3

Fernbedienung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

 

6.4

Klimamodi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

38

 

6.5

Zusatzfunktionen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

7 Vor dem ersten Gebrauch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

8 Staukastenklimaanlage bedienen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 8.1 Grundsätzliche Hinweise zur Bedienung. . . . . . . . . . . . . . . . . . . . . .41 8.2 Fernbedienung verwenden . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 8.3 Hinweis zur besseren Nutzung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 8.4 Staukastenklimaanlage einund ausschalten . . . . . . . . . . . . . . . . . . 42 8.5 Klimamodus wählen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.6 Gebläsestufe manuell wählen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.7 Temperatur einstellen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.8 Timer programmieren . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

30

DE

 

Loading...
+ 362 hidden pages