Dometic DM50D, DM50F, DM50 Installation And Operating Manual

Page 1
Drawer Minibar
Installation and Operating Manual . . . 3
EN
DM50
Page 2
Page 3
DM50
3
Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it.
The manufacturer cannot be held liable for damage resulting from
improper usage or incorrect operation.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
10 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Page 4
Explanation of symbols DM50
4
1 Explanation of symbols
! !
A
I
Action: This symbol indicates that action is required on your part. The
required action is described step-by-step.
This symbol describes the result of an action.
Fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.
2 Safety instructions
2.1 General safety
!
WARNING!
Do not operate the device if it is visibly damaged.
This device may only be repaired by qualified personnel.
Improper repairs can lead to considerable hazards.
This device can be used by children aged 8 years and above as
well as persons with reduced physical, sensory or mental capa­bilities or lack of experience and knowledge, if they are super­vised or have been instructed to safely use the device and if they understand the hazards resulting out of it.
WARNING! Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
CAUTION! Safety instruction: Failure to observe this instruction can lead to
injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the function of the product.
NOTE
Supplementary information for operating the product.
Page 5
DM50 Safety instructions
5
Cleaning and user maintenance must not be carried out by chil-
dren without supervision.
Always keep and use the device out of the reach of children
under the age of 8 years.
Children must be supervised to ensure that they do not play with
the device.
If this device's power cable is damaged, it must be replaced by
the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.
Do not store any explosive substances such as spray cans with
a flammable propellant in the device.
!
CAUTION!
Disconnect the device from the mains
before each cleaning and maintenance – after every use
Food may only be stored in its original packaging or in suitable
containers.
A
NOTICE!
Connect the device with the 230 V connection cable to the
230 V AC mains supply.
Check that the voltage specification on the type plate
corresponds to that of the energy supply.
The cooling device is not suitable for transporting caustic
materials or materials containing solvents.
Never pull the plug out of the socket by the cable.
2.2 Operating the device safely
A
NOTICE!
Do not use electrical devices inside the cooler unless they are
recommended by the manufacturer for the purpose.
Do not place the device near naked flames or other heat
sources (heaters, direct sunlight, gas ovens etc.).
Page 6
Scope of delivery DM50
6
Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat that arises during operation does not build up. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
Ensure that the ventilation openings are not covered.
Do not fill the inner container with ice or fluid.
Never immerse the device in water.
Protect the device and the cable against heat and moisture.
3 Scope of delivery
The following main alternatives are obtainable:
Minibar DM50D with door panel, without lock
Minibar DM50D with door panel, with lock
Minibar DM50F without door panel, without lock
Minibar DM50F without door panel, with lock
Quantity Description
1 Minibar
1 Cable for 230 Vw connection
4 Screw ø4 x 45 mm (Installation)
4 Plug (Installation)
1 Handle DM50D only
2 Plug (Handle installation) DM50D only
1 Inlet filter
6 Screw ø3 x 12 mm(Filter installation)
2 Plug (Wooden panel) DM50F wooden version
only
1 Lock decor (Wooden panel) DM50F wooden version
with lock only
2 Key Lock version only
1 Installation and Operating manual
Page 7
DM50 Proper use
7
4 Proper use
The Dometic Minibars DM50D and DM50F are designed for use inside a piece of furniture and are suitable for cooling beverages and food.
The device is designed for use with a 230 V AC mains supply.
The cooling device is intended to be used in household and similar applications such as
staff kitchen areas in shops, offices and other working environments
farm houses
clients in hotels, motels and other residential type environments
bed and breakfast type environments
catering and similar non-retail applications
!
5 Technical description
The minibar has a main drawer for bottles and cans as well as a mini drawer for miniatures and snacks. The main drawer has room for 33 bottles with a maximum height of 30 cm.
The minibar DM50D comes with a anthracite panel and pull handle.
The minibar DM50F is delivered without panel and is prepared for fitting the hotel's own door decor.
Its cooling system is a non-wearing Peltier cooling system with the heat discharged by a fan.
A lock is optionally available.
CAUTION! Health hazard!
Please check if the cooling capacity of the device is suitable for storing the food or medicine you wish to cool.
Page 8
Technical description DM50
8
5.1 Description of the device
Front panel
Item Description
1 Lock (optional)
2 Handle (DM50D only)
3 Door panel (DM50D only)
1
2
3
Page 9
DM50 Technical description
9
Rear side
Item Description
1 Mains adaptor
2 12 Vg socket
3 Cooling unit cover
4 Ventillation openings
5 Drip tray
1
2
3
4
5
Page 10
Technical description DM50
10
Control panel (inside the device)
Item Description
1 Lamp
2 Error LED
3 Status LED
4 Setting button
1
2 43
Page 11
DM50 Technical description
11
Main drawer
Item Description
1 Wide divider
2 Separator
3 Small divider
4 Bottle finger
4
3
2
1
Page 12
Technical description DM50
12
Mini drawer
Dimensions
Item Description
1 Rotatable divider
2 Miniature bottle holder
1
2
160
450
67
480
508
418
91,2
93
Page 13
DM50 Installation
13
6 Installation
6.1 Notes on mounting into furniture
You can mount the minibar in four ways into furniture. Choose your favoured alternative according to the following figure (page 14).
Observe the following:
The cut-out dimensions H x W x D are:
DM50D: 428 x 570 x 485 mm – DM50F: 428 x 570 x (485 + d) mm
d is the thickness of the hotel‘s own decor
The clearance between the minibar‘s back and the furniture wall should
be approx. 5 mm.
The ventilation openings for the chosen alternative have to be produced
as shown in following figure (page 14).
Air passing through the inlet air duct must not be heated by any heat
sources (heaters, direct sunlight, gas ovens etc.).
Page 14
Installation DM50
14
1 1
1 1
AB
CD
≥ 15
30
120
≥ 35 cm²
≥ 35 cm²
30
120
260
30 x 300
≥ 150 cm²
≥ 150 cm²
≥ 150 cm²
Page 15
DM50 Installation
15
6.2 Pressing out the ventilation opening
Produce a ventilation opening of 30 x 300 mm in the bottom of the
furniture into which you place the minibar.
Measure the distance of 470 mm from the minibar‘s door front excluding any own decor.
470
30
300
Page 16
Installation DM50
16
6.3 Mounting the minibar into a piece of furniture
Fasten the minibar with the four screws ø4 x 45 mm (1).
Insert the four plugs (2) into the boring.
Fasten the inlet filter (5) with the six screws ø3 x 12 mm (6) to ventilation
opening (4) of the furniture (3).
Item Description
1 Screw ø4 x 45 mm
2Plug
3Furniture
4 Ventilation opening
5Filter
6 Screw ø3 x 12 mm
1
3
2
4
5
6
AB
Page 17
DM50 Operation
17
6.4 Connecting the minibar electrically
Plug the 230 V connection cable into the AC voltage socket and connect
it to the 230 V AC mains supply.
The status LED lights up.
The minibar starts cooling the interior.
6.5 Mounting hotel's own door decor (DM50F only)
The hotel's own door decor has to comply with the following requirements:
Maximum weight: 2 kg
Maximum thickness: 14 mm
Fasten the decor with four screws.
Mounting the lock (lock version only)
Drill a hole with a diameter of 35 mm into the decor.
Mount the lock together with the lock decor.
7 Operation
7.1 Energy saving tips
Do not open the cooling device more often than necessary.
Do not leave the cooler unit open for longer than necessary.
Page 18
Operation DM50
18
7.2 Using the minibar
The minibar starts cooling when connected to power. During normal operation the Status LED is glowing. If an error occurs the Error LED is blinking (see chapter “Troubleshooting” on page 19).
The minibar is set by default to a cooling temperature of 7 °C at an ambient temperature of 25 °C.
You can use the setting button (1) to set the cooling temperature to one of three values (5 °C, 12 °C and 7 °C).
Thereby the temperature will be changed in the order 5 °C … 12 °C … 7°C… 5°C etc.
Press the setting button (1) and keep it pressed for 3 s, until the lamp (2)
starts to blink.
Press immediately the setting button (1) again.
The lamp (2) indicates the setting temperature:
5 °C: the lamp flashes five times in three intervals – 12 °C: the lamp flashes once in three intervals – 7 °C: the lamp flashes three times in three intervals
I
NOTE
The minibar sets the cooling temperature automatically to 7 °C, when it is connected to a power source.
2 1
Page 19
DM50 Troubleshooting
19
8 Troubleshooting
Fault Possible cause Suggested remedy
Device does not function, Status LED does not glow.
No voltage present in the AC voltage socket.
Try using another plug socket.
The mains adapter is defective.
This can only be repaired by an authorised repair centre.
The device does not cool (plug is inserted, Status LED glows).
The cooling element is defective.
This can only be repaired by an authorised repair centre.
The Error LED flashes once per second.
Temperature sensor is defective.
This can only be repaired by an authorised repair centre.
The Error LED flashes twice per second.
The fan is defective. This can only be repaired by an
authorised repair centre.
Device does not cool sufficiently, Status LED glows, Error LED does not glow.
The cooling element is defective.
This can only be repaired by an authorised repair centre.
Poor ventilation Check the ventilation.
Clean the filter underneath the device.
Page 20
Cleaning and maintenance DM50
20
9 Cleaning and maintenance
!
A
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any
dust and dirt, so that heat can be released and the device is not damaged.
Occasionally clean the inlet filter.
If you find water in the drip tray (1) check whether the drainage system is
blocked.
WARNING!
Always disconnect the device from the mains before you clean and service it.
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
P
E
S
1
Page 21
DM50 Guarantee
21
10 Guarantee
The statutory warranty period applies. If the product is defective, please contact your retailer or the manufacturer's branch in your country (see the back of the instruction manual for the addresses).
For repair and guarantee processing, please include the following docu­ments when you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
11 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
Page 22
Technical data DM50
22
12 Technical data
DM50D DM50F
Voltage: 100 – 240 Vw, 50 Hz
Cooling capacity: max. 21 °C under ambient temperature
(adjustable in three steps: 5 °C, 7 °C, 12 °C)
Category: 2 (Cellar)
Gross capacity: 50 l
Capacity: 45 l
Energy efficiency class: A
Power consumption: 139 kWh/annum
Climatic class: N
Ambient temperature: +16 °C to +32 °C
Noise emission: 37.6 dB(A)
Dimensions main drawer W x D x H: 430 x 330 x 302 mm
Dimensions mini drawer W x D x H: 159 x 285 x 88 mm
Dimensions W x D x H: 550 x 508 x 418 mm 550 x 485 x 418 mm
Weight: 21.5 kg 21.0 kg
Inspection/certification:
Page 23
Page 24
AUSTRALIA Dometic Australia Pty. Ltd.
1 John Duncan Court Varsity Lakes QLD 4227
+61 7 55076000+61 7 55076001
Mail: sales@dometic-waeco.com.au
AUSTRIA Dometic Austria GmbH
Neudorferstrasse 108 2353 Guntramsdorf
+43 2236 908070+43 2236 90807060
Mail: info@waeco.at
BENELUX Dometic Benelux B.V.
Ecustraat 3 NL-4879 NP Etten-Leur
+31 76 5029000+31 76 5029090
Mail: info@dometic.nl
DENMARK Dometic Denmark A/S
Nordensvej 15, Taulov DK-7000 Fredericia
+45 75585966+45 75586307
Mail: info@waeco.dk
FINLAND Dometic Finland OY
Mestarintie 4 FIN-01730 Vantaa
+358 20 7413220+358 9 7593700
Mail: info@dometic.fi
FRANCE Dometic SAS
ZA du Pré de la Dame Jeanne F-60128 Plailly
+33 3 44633500+33 3 44633518
Commercial : info@dometic.fr SAV/Technique : service@dometic.fr
HONG KONG WAECO Impex Ltd.
Suites 2207-2211 · 22/F · Tower 1 The Gateway · 25 Canton Road, Tsim Sha Tsui · Kowloon Hong Kong
+852 24611386+852 24665553
Mail: info@dometic-waeco.com.hk
HUNGARY Dometic Plc. Sales Office
Kerékgyártó u. 5. H-1147 Budapest
+36 1 468 4400+36 1 468 4401
Mail: budapest@dometic.hu
ITALY Dometic Italy S.r.l.
Via Virgilio, 3 I-47100 Forlì
+39 0543 754901+39 0543 756631
Mail: info@dometic.it
NORWAY Dometic Norway AS
Skolmar 24 N-3232 Sandefjord
+47 33428450+47 33428459
Mail: firmapost@waeco.no
POLAND Dometic Poland Sp. z o.o.
Ul. Puławska 435A 02-801 Warszawa Poland
+48 22 414 32 00+48 22 414 32 01
Mail: info@dometic.pl
RUSSIA Dometic RUS LLC
Komsomolskaya square 6-1 107140 Moscow Russia
+7 495 780 79 39+7 495 916 56 53
Mail: info@dometic.ru
SLOVAKIA Dometic Slovakia s.r.o.
Tehelná 8 SK-98601 Fiľakovo
+421 47 4319 107+421 47 4319 166
Mail: info@dometic.sk
SPAIN Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16 E-28691 Villanueva de la Cañada Madrid
+34 902 111 042+34 900 100 245
Mail: info@dometic.es
SWEDEN Dometic Scandinavia AB
Gustaf Melins gata 7 S-42131 Västra Frölunda (Göteborg)
+46 31 7341100+46 31 7341101
Mail: info@waeco.se
SWITZERLAND Dometic Switzerland AG
Riedackerstrasse 7a CH-8153 Rümlang (Zürich)
+41 44 8187171+41 44 8187191
Mail: info@dometic-waeco.ch
TAIWAN WAECO Impex Ltd.
Taipei Office 2 FL-3 · No. 56 Tunhua South Rd, Sec 2 Taipei 106, Taiwan
+886 2 27014090+886 2 27060119
Mail: marketing@dometic-waeco.com.tw
UNITED KINGDOM Dometic UK Ltd.
Dometic House · The Brewery Blandford St. Mary Dorset DT11 9LS
+44 844 626 0133+44 844 626 0143
Mail: sales@dometic.co.uk
UNITED ARAB STATES Dometic Middle East FZCO
P. O. Box 17860 S-D 6, Jebel Ali Freezone Dubai, United Arab Emirates
+971 4 883 3858+971 4 883 3868
Mail: info@dometic.ae
UNITED STATES OF AMERICA Dometic Marine Division
2000 N. Andrews Ave. Extension Pompano Beach, FL 33069 USA
+1 954 973 2477+1 954 979 4414
Mail: marinesales@dometicusa.com
GERMANY Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten +49 (0) 2572 879-195 · +49 (0) 2572 879-322 Mail: info@dometic-waeco.de · Internet: www.dometic-waeco.de
www.dometic.com
4445100841 07/2014
Loading...