E3 Shorted Indoor Temperature Sensor.
All heat, cool, and dehumidify opera­tion will be locked out. Manual fan op­eration can continue.
E4 Open circuit or out of range Outdoor
Temperature Sensor (Select Models). Heat pump and dehumidifi cation op- eration will be locked out. Air condi­tioner, furnace, heat strip, and fan op­eration can continue to operate.
E5 Open circuit or out of range Freeze
Sensor (Select Models). Air condition­er and dehumidifi cation operation will be locked out. Heat pump, furnace, heat strip, and fan operation can con­tinue to operate but displays the last temperature set-point.
E6 Open circuit Humidity Sensor (Select
Models). Air conditioner and dehu­midifi cation operation will be locked out. Heat pump, furnace, heat strip, and fan can continue to operate.
E7 Loss of 120 VAC power to all power
module boards on the system. The system will shut down.
E8 Invalid zone confi guration. The heat
pump and heat strip DIP switches are both set to the ON position in one zone. Heat pump, heat strip, air con­ditioner, and dehumidify operation will be locked out in the affected zone.
E9 Invalid zone confi guration. The dehu-
midifi er DIP switch and either the heat pump or heat strip DIP switches are set to the ON position in one zone. Heat pump, heat strip, air condition­er, and dehumidify operation will be locked out in the affected zone.
In the unlikely event you experience a system failure, refer to the “SERVICE” section of the Operating Instructions furnished with your unit.
Special Features:
● Auto Fan
● Stage Select (Two air conditioners/ heat pumps or models equipped with two compressors)
● Programs 1 & 2
● Auxiliary Heat (heat pump models only)
● Load Shed
● Automatic Generator Start (optional) See Operating Instructions Manual for more information on special fea­ture.
LCD Error Code
When the system determines that one of the faults listed below has occurred an error code will be displayed in the LCD for the zone in which the error occurred. During normal operation, a blinking zone number indicates a fault has occurred. The error code is displayed in place of the temperature set-point.
Error Code:
E1 Loss of communication between the
CCC 2 thermostat and all system power module boards. System will shut down.
E1 Loss of communication between the
CCC 2 thermostat and an individual system power module board. The LED will display error code E1 and the zone number that lost communi­cation. Any additional zones that lose communication will blink in addition to the current zone.
E2 Open circuit or out-of-range Indoor
Temperature Sensor. All heat, cool, and dehumidify operation will be locked out. Manual fan operation can continue.
Comfort Control Center 2 Thermostat
User’s Guide
USA
SERVICE OFFICE
Dometic, LLC
2320 Industrial Parkway
Elkhart, IN 46516
574-294-2511
CANADA
Dometic, LLC
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
519-720-9578
For Service Center
Assistance Call:
800-544-4881
Dometic Comfort Control Center 2 Thermostat Quick Start-Up
The basic steps for operating your Air Conditioner, Heat Pump or Dehumidifi er (herein after referred to as the “unit”), are described in this User’s Guide. For more detailed information on modes of operation and special features refer to the Operating Instruc­tions Manual.
Quick reference to control buttons
Press to display inside temperature
Press to select temperature format
Press to decrease temperature or humidity set-point
Press to increase temperature or humidity set-point
Press to display relative humidity set­point (Select Models)
Press to select zone
Press to select On and OFF
Press to select fan speed
Press to set clock
Press to select mode
Press to select program 1 or 2
REVISION
Form No. 3314150.016 10/11
(Replaces 3314150.000)
(French 3314170.014)
©2011 Dometic, LLC
LaGrange, IN 46761
1. To turn ON the CCC 2 thermostat when the back light is off, fi rst press any button to wake up the CCC 2 thermostat. Then press and release the ON/OFF button.
2. Press the MODE button to cycle through the mode options. A mode is
an operation that can be performed by the unit and is controlled by the Dometic CCC thermostat. The available modes are: OFF, COOL, HP (HEAT PUMP), HS (Heat Strip), FAN, FURN (Furnace), and AUTO.
The available modes are determined by your system options.
3. Press the ZONE button to cycle through the available zones to be programmed. Each zone signi es a
unit designated to cool, heat or de­humidify a specifi c area of an RV. The Dometic CCC 2 thermostat can control up to four units (zones).
4. Press the UP or DOWN but- tons to increase or decrease the room air temperature (hereinafter referred to as the set-point). The set-point
is the desired inside room air tem­perature.
5. Press the FAN button to select the fan speed. The options are AUTO, HI, MED, or LO.
7. Press and hold the INSIDE TEMP button and the LCD will display the current inside temperature recorded at the CCC 2 Thermostat (or at the optional remote indoor temperature sensor) instead of the temperature set-point. The LCD will also display “IN” to indicate that the inside tem­perature is being displayed. When the INSIDE TEMP button is released, the LCD will return to the programmed temperature set-point.
6. Press the CLOCK button to initiate the clock setting sub-menu on the CCC 2 thermostat. When entering this menu, the “hour” digits will fl ash rst. Press the CLOCK button again and the “minutes” digits will fl ash. Press it a third time and the “AM” or “PM” icon will fl ash. Press the UP and DOWN but- tons to set the “hour”, “minute”, and “AM/PM” setting. Press the CLOCK button one more time to store the new time in memory and exit the clock setting sub-menu.