Dometic COE-C, COE-CG, COE-CGO, COE-FULL, COE-C-DUFU Operating And Installation Instructions

...
Operating and Installation Instructions
for
CRAMER COE Gas Cooker
Models:
(4 gas burners)
COE-CG Cooker + grill
(4 gas burners)
COE-CGO Cooker + grill + oven
(4 gas burners)
COE-FULL Cooker + grill + oven + pot store
(4 gas burners)
COE-C-DUFU
Cooker
(3 gas burners + 1 electric burner)
COE-CG-DUFU Cooker + grill
(3 gas burners + 1 electric burner)
COE-CGO-DUFU Cooker + grill + oven
(3 gas burners + 1 electric burner)
COE-FULL-DUFU Cooker + grill + oven + pot store
(3 gas burners + 1 electric burner)
EN
UK
CE-0085
2
Important
This appliance is a class 3 appliance intended for installation in a kitchen unit.
Output of the hob (Hs) 4 x 1.6 = 6.4 kW (Mn = 465 g/h, propane/butane) or, in the case of the DUFU (dual fuel) model: Output of the hob (Hs) 3 x 1.6 = 4.8 kW (Mn = 465 g/h, propane/butane) 1 x 800W (230V AC / 3.5 A) Output of the grill (Hs) 1.4 kW (Mn = 100 g/h, propane/butane) Output of the oven (Hs) 1.1 kW (Mn = 80 g/h, propane/butane)
The appliance requires 12 V DC to power any internal light and the timed spark ignition.
The pressure regulators used between the gas cylinder and the appliance must comply with the categories in the following table:
Appliance category Supply pressure Gas I
3+
28-30/37 mbar butane/propane I3B 30 mbar butane I
3B/P
28-30 mbar butane/propane I
3B/P
30 mbar butane/propane I
3P
28-30 mbar propane I3B 50 mbar butane I
3B/P
50 mbar butane/propane
It is also possible to operate a 30 mbar appliance in campers with a 50 mbar gas system, but
only if a 50/30 mbar primary pressure regulator is pre-fitted. ! !
The user must read these operating instructions to familiarise himself/herself with use of the appliance. The appliance fitter must hand these operating instructions to the user. We recommend concluding a service contract.
If the gas tap becomes sluggish or jammed, then it must either be replaced or the affected tap removed from the chamber, cleaned in benzene and lubricated with a special gas tap grease, e.g. type "Staburgas no. 32" from the Klüber company in Munich. This work must be carried out by a professional gas technician.
The appliance must be installed by an authorized technician! Particular attention must be paid to the EN 1949 standard in addition to the usual regulations!
This appliance must be installed and connected according to the applicable installation conditions. Special attention must be paid to suitable ventilation.
Before connecting the appliance, ensure that the local conditions (gas type and gas pressure) match the appliance settings. The gas type and gas pressure for this appliance are indicated on an information label (or on the identification plate).
Gas-bearing parts and the connected exhaust lines (waste gas pipe) must be inspected by an expert before the initial start-up and at intervals of 2 years in accordance with the applicable standards, in particular EN 1949 (in Germany also in accordance with DVGW Worksheets G 607 and G 608).
3
The operator is responsible for having the necessary inspections conducted. S/he must be notified in writing of the inspection requirement by the technician who installs the appliance.
The appliance may be used only for cooking, baking and grilling under the conditions specified elsewhere in these instructions. Under no circumstances may it be used for other purposes (e.g. heating, etc.).
Use of the appliance can result in the accumulation of humidity or heat in the installation location. Make sure that the kitchen is well-ventilated: keep the normal ventilation openings open or provide for a mechanical ventilation device.
Intensive or prolonged used of the appliance may require additional ventilation, e.g. opening a window or operation of the mechanical ventilation device at a higher setting.
A sign must be fitted above the cooker, stating that the closable vent must be opened while the cooker is in use, and that the burners must not be used for heating. The sign must be clearly visible.
IMPORTANT: When using gas kitchen appliances, the closable vents in the installation location must be open. Naked burners must not be used for heating!
IMPORTANT: THE APPLIANCE MUST BE INSTALLED BY AN AUTHORIZED TECHNICIAN IN ACCORDANCE WITH THE APPLICABLE STANDARDS (EN
1949).
THE ELECTRIC COMPONENT (IN THE CASE OF THE COE … DUFU MODELS) MUST BE INSTALLED BY AN AUTHORISED TECHNICIAN IN ACCORDANCE WITH THE APPLICABLE REGULATIONS (IN PARTICULAR EN 60335, EN 1648).
IMPORTANT: TO PREVENT ANY RISK OF ACCIDENT, IT IS NECESSARY THAT THE APPLIANCE BE INSTALLED ACCORDING TO THESE INSTRUCTIONS. IMPROPER INSTALLATION WILL VOID THE WARRANTY.
“ANY MODIFICATION TO THE APPLIANCE MAY BE DANGEROUS AND IS PROHIBITED!”
1. ROOM VENTILATION
Any room in which one or more appliances are to be installed must have one or more vents enabling fresh air to enter. One or more vents must be located above the appliance to ensure sufficient disposal of combustion products and sufficient fresh air supply for the user. These vents must comply with the requirements specified in the EN 1949, EN 1646-1 and EN 721 standards.
The user must check and, if necessary, clean these vents from time to time (for example, they must be cleaned of snow or slush during the winter).
4
The following applicable regulations must be observed when installing the gas appliance
EN 1645-1 EN 1646-1 EN 1648 EN 1949 EN 60335 EN 721
(In Germany, the 1988 Technical Rules Governing Liquid Gas, and the rules specified in the DVGW worksheets G 607 (vehicles) and/or G 608 (boats) must also be observed).
2. CONNECTING THE APPLIANCE TO THE GAS SUPPLY
Only gas-tight connection fittings may be used to connect the appliance to the gas supply line.
The pipes for connecting the appliance should be made of galvanized iron or copper. These pipes must be used with a gas-tight connection fitting. After the connection has been established, the gas lines should be checked by applying a soap solution to the connecting points; any leaks can be detected by the formation of bubbles.
IMPORTANT: DURING INSTALLATION AND CONNECTION OF THE APPLIANCE, MAKE SURE THAT THE GAS INLET PIPE IS NOT TWISTED, PULLED OR OTHERWISE STRAINED.
3. GAS CYLINDERS
Use gas cylinders that are commercially available in the country where the appliance was purchased. The type of gas is indicated clearly on the package and on the indelible type plate on the back of the appliance.
THE USE OF DIFFERENT GAS PRESSURES OR GAS TYPES FROM THOSE SPECIFIED IN THE REGULATIONS CAN RESULT IN IRREGULAR OPERATION OF THE APPLIANCE; THEREFORE, THE MANUFACTURER SHALL ASSUME NO RESPONSIBILITY FOR IMPROPER USE OF THE APPLIANCE.
Always comply with the following instructions:
The gas cylinder, including valves and pressure reducers (regulators), must be installed vertically in the cabinet provided; the cylinders must be freely accessible.
It must be possible to replace the gas cylinder easily and without obstructions.
THE GAS CYLINDER VALVE SHOULD BE CLOSED WHEN NOT IN USE.