Dometic CK36H401RI, CK36H401RIY, HARRIER CK36H401RIY, HARRIER CK36H401RI Operating Manual

EN
CLIMATE CONTROL
HARRIER
CK36H401RI, CK36H401RIY
Air conditioning roof unit
Operating manual
Harrier Inverter
EN
Dometic Harrier Inverter
Please read this instruction manual carefully before installation and start­up, and store it in a safe place. If you pass on the device to another person, hand over this instruction manual along with it.
Table of contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Target group for this manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
8 Operating the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
9 Cleaning the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
10 Maintenance of the roof air conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
11 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
14 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3
EN
Explanation of symbols Dometic Harrier Inverter
1 Explanation of symbols
WARNING!
! !
A
I
Safety instruction: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION! Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
• Damage to the product resulting from mechanical influences and incorrect connection voltage
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in the operating manual
In particular, the manufacturer will not be liable for any consequential damage, especially consequential damage caused by failure of the roof air conditioner.
Note the following basic safety information when using electrical devices to protect against:
• Electric shock
•Fire hazards
•Injury
4
EN
Dometic Harrier Inverter Safety instructions
2.1 General safety
WARNING!
!
Electrical devices are not toys. The device is not to be used by persons (including children) with reduced physical, sensory or mental capa­bilities, or lack of experience and knowledge, unless they are under supervision or have been given instruction.
Children should be supervised to ensure that they do not play with the device.
This device can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are under supervision or have been given instruction concerning use of the device in a safe way and understand the hazards involved.
Children shall not play with the device.
Cleaning and user maintenance shall not be performed by children without supervision.
Only use the device as intended.
Do not make any alterations or conversions to the device.
Installation, maintenance and repairs of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).
Do not use the device near flammable fluids or in closed rooms.
Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept.
5
EN
Target group for this manual Dometic Harrier Inverter
Do not reach into air outlets or insert any foreign objects in the roof air conditioner.
Do not undo the upper cover of the roof air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
NOTICE!
A
I
• Never drive through automatic car washes when the roof air conditioner is mounted.
• If faults occur in the roof air conditioner's refrigerant circuit, the roof air conditioner must be checked by a specialist company and properly repaired. The refrigerant must never be released into the air.
NOTE
• Please ask your vehicle manufacturer if a technical inspection is required after fitting an air conditioner and whether the height entered in your vehicle documents needs to be altered: – Harrier Inverter: increased height 255 mm
2.2 Operating the device safely
WARNING!
!
A
Always disconnect the power supply when working on the device.
NOTICE!
• The roof air conditioner is not suitable for use in agricultural or construction vehicles.
• Operate the device only if you are certain that the housing and the cables are undamaged.
3 Target group for this manual
This operating manual is for the user of the roof air conditioner.
6
EN
Dometic Harrier Inverter Scope of delivery
4Scope of delivery
Rooftop unit
Designation Quantity Ref. number
Dometic Harrier Inverter roof air conditioner 1 CK36H401RI2
CK36H401RIY2
ADB with oscillation vents 1 CA02HR112
Installation manual 1
Operating manual 1
5 Intended use
The Dometic Harrier Inverter roof air conditioner can condition the interior of campers and caravans with cool or warm dehumidified air.
The roof air conditioner is not suitable for installation in construction machines, agri­cultural machines or similar equipment. It will not work properly if exposed to strong vibrations.
Do not operate the roof air conditioner if the ambient temperature is above 52 °C (at extreme temperatures the performance will be affected).
6 Technical description
The roof air conditioner supplies the interior with cool or warm dehumidified air with­out dust and dirt.
LED lamps integrated in the air outlet unit provide pleasant lighting.
The roof air conditioner is operated with the remote control.
NOTE
I
• The roof air conditioner can lower the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your roof air conditioner.
• Below an outside temperature of 16 °C the roof air conditioner doesn’t cool anymore.
7
EN
1
Technical description Dometic Harrier Inverter
6.1 Components
1
4
3
2
The refrigerant circuit of the roof air conditioner consists of the following main components:
Compressor (1)
The compressor draws in the refrigerant used and compresses it. This raises the pressure and therefore the temperature of the refrigerant.
Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The refrigerant absorbs the heat and vaporises.
Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet unit.
8
EN
Dometic Harrier Inverter Technical description
1 2 3 54
67810 9
2
6.2 Control panel
The control panel is at the air outlet unit of the roof air conditioner.
It contains the following control and display elements:
No. Explanation
1Button P Switches the roof air conditioner on, off or to stand-by mode
With status indicator:
Off: The roof air conditioning is switched off (no mains power).
Red light: The roof air conditioner is in stand-by mode.
White light: The roof air conditioning is switched on.
2
Button
3 Display Fan, Mode, Timer, Oscillation, Temperature setting, °C or °F
4Button + Increases the temperature setting
5
Button
6
Button
7Button Reduces the temperature setting
8 Infrared receiver for
the remote control
9
Button
10 Button M Switches the mode to:
Switches the fan level to: LOW, MED, HIGH, AUTO
Switches the front oscillation vent On/Off.
Switches the rear oscillation vent On/Off.
Switches the light on or off.
COOL, HEAT, DEHUMIDIFICATION, VENTILLATION, AUTO
9