Dometic 57908.321, 57908.521, 57912.321, 57912.531, 57912.621 User Manual

...
USA
C
S
SERVICE OFFICE The Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 260-463-4858
ANALOG DUCTED INSTALLATION INSTRUCTIONS
RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE:
Model Number Serial Number Date Purchased
600 Series PENGUIN
579 Series BRISK AIR
590 Series QUICK COOL
591 Series HEAT PUMP
595 Series QUICK COOL
Roof Top Air Conditioner/Heat Pump
USED WITH
Part No. 3107541 and 3107546
Analog Relay Kit
WITH REMOTE ANALOG THERMOSTAT
DUCTED
THIS UNIT IS DESIGNED FOR OEM INSTALLATION
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT.
Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7 519-653-4390
For Service Center Assistance Call:
800-544-4881
U
INSTALLATION
INSTRUCTIONS
WARNING
!
This manual must be read and un­derstood before installation, adjust­ment, service, or maintenance is per­formed. This unit must be installed by a qualified service technician. Modification of this product can be extremely hazardous and could re­sult in personal injury or property damage.
57908.321
57908.521
57912.321
57912.531
57912.621
57912.622
57912.631
57915.331
57915.336
57915.421
AVERTISSEMENT
!
Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. L'installation de cet appareil doit être effectuée par un réparateur qualifié. Toute modification de cet appareil peut être extrêmement dangereuse et entraîner des blessures ou dommages matériels.
MODELS
57915.422
57915.426
57915.521
57915.522
57915.526
57915.531
57915.536
57915.621
57915.622
57915.626
57915.631
57915.731
59016.521
59016.621
59516.331
59516.336
59516.501
59516.531
59516.536
59516.601
59516.603
59516.606
59516.631
59528.601
59529.531
59529.601
59529.631
59530.531
59530.532
59530.536
59530.601
59530.631
59530.632
600312.321
600312.421
600315.321
600315.326
600315.421
REVISION
Form No. 3107163.101 6/03 (Replaces 3107163.093) (French 3108062.071) ©2003 Dometic Corporation LaGrange, IN 46761
Important: These instructions
must stay with unit. Owner read carefully.
1
ANALOG DUCTED INSTALLATION INSTRUCTIONS
SAFETY INSTRUCTIONS
This manual has safety information and instruc­tions to help users eliminate or reduce the risk of accidents and injuries.
RECOGNIZE SAFETY INFORMATION
!
This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
Follow recommended precautions and safe op­erating instructions.
UNDERSTAND SIGNAL WORDS
1. GENERAL INFORMATION
A. Product features or specifications as described or illus-
trated are subject to change without notice.
B. This air conditioner is designed for:
1. Installation on a recreational vehicle during the time the vehicle is manufactured.
2. Mounting on the roof of a recreational vehicle.
3. Connection to an air distribution system located in the ceiling/roof cavity of the recreational vehicle.
4. Roof construction with rafters/joists on minimum of 16 inch centers.
5. Minimum of 2.00" and maximum of 5.50" distance between roof to ceiling of recreational vehicle. Alter­nate installation methods will allow for roofs more than 5.50" thick.
C. The ability of the air conditioner to maintain the desired
inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by:
1. Parking the RV in a shaded area
2. Using window shades (blinds and/or curtains)
3. Keeping windows and doors shut or minimizing usage
4. Avoiding the use of heat producing appliances.
A signal word , WARNING OR CAUTION is used with the safety-alert symbol. They give the level of risk for potential injury .
WARNING
!
indicates a potentially hazard­ous situation which, if not avoided, could result in death or serious injury .
CAUTION
!
indicates a potentially hazard­ous situation which, if not avoided may result in minor or moderate injury .
CAUTION
used without the safety alert symbol indicates, a potentially hazardous situa­tion which, if not avoided may result in property damage.
Read and follow all safety information and instruc­tions.
Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside tem­peratures.
Starting the air conditioner early in the morning and giving it a "head start" on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature.
For a more permanent solution to high heat gain, accesso­ries like A&E outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening.
D. Condensation Note: The manufacturer of this air conditioner will not be
responsible for damage caused by condensed moisture on ceilings or other surfaces. Air contains moisture and this moisture tends to condense on cold surfaces. When air enters the RV, condensed moisture may appear on the ceiling, windows, metal parts, etc. The air conditioner re­moves this moisture from the air during normal operation. Keeping doors and windows closed when this air conditioner is in operation will minimize condensed moisture on cold surfaces.
2
12 AWG
Copper
ANALOG DUCTED INSTALLATION INSTRUCTIONS
up to 24’
SPECIFICATIONS
(BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE**
115V AC,
60 HZ., 1PH.
COOLING AMPS AMPS “ W. C. SUPPLIED 1 UNIT/ 2 UNITS
When sizing the generator, the tot al power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and
from lack of maintenance.
MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUM
NO. CAPACIT Y RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STA TIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR
57908.321 7,180 6.9 36.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 75 2.5 KW / 4.0 KW
57908.521 7,100 6.6 34.0 2.5 5.8 325 / 250 0.55 / 0.90 17.0 20 Amp 75 2.5 KW / 4.0 KW
57912.321 11,000 9.5 53.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 9 4 2.5 KW / 4.0 KW
57912.531 11,000 8.0 53.0 2.5 5.8 325 / 250 0.55 / 0.90 18.5 20 Amp 9 4 2.5 KW / 4.0 KW
57912.621 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 9 4 2.5 KW / 4.0 KW
57912.622 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 9 4 2.5 KW / 4.0 KW
57912.631 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 9 4 2.5 KW / 4.0 KW
57915.331 13,500 1 1.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 10 0 3.5 KW / 5.0 KW
57915.336 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 100 3.5 KW / 5.0 KW
57915.421 13,500 1 1.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 13.5 20 Amp 10 0 3.5 KW / 5.0 KW
57915.422 13,500 1 1.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 14.5 20 Amp 10 0 3.5 KW / 5.0 KW
57915.426 13,500 1 1.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 13.5 20 Amp 10 0 3.5 KW / 5.0 KW
57915.521 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.522 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.526 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.531 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.536 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.621 13,500 1 1.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 9 4 3.5 KW / 5.0 KW
57915.622 13,500 1 1.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 9 4 3.5 KW / 5.0 KW
57915.626 13,500 1 1.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 9 4 3.5 KW / 5.0 KW
3
57915.631 13,500 1 1.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 9 4 3.5 KW / 5.0 KW
57915.731 13,500 1 1.3 56.0 2.5 5.8 325 / 250 0.55 / 0.90 15.0 20 Amp 9 4 3.5 KW / 5.0 KW
59016.521 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 /1.1 0 26.5 20 Amp 101 3.5 KW / 5.0 KW
59016.621 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 101 3.5 KW / 5.0 KW
59516.331 15,000 1 1.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29.0 20 Amp 9 4 3.5 KW / 5.0 KW
59516.336 15,000 12.7 60.0 2.0 5.6 325 / 250 0.40 / 1.10 29.0 20 Amp 94 3.5 KW / 5.0 KW
59516.501 15,000 1 1.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 31.0 20 Amp 9 4 3.5 KW / 5.0 KW
59516.531 15,000 1 1.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 26.5 20 Amp 9 4 3.5 KW / 5.0 KW
59516.536 15,000 1 1.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29 20 Amp 94 3.5 KW / 5.0 KW
59516.601 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW
59516.603 15,000 12.3 77.0 2.0 5.6 325 / 250 0.40 / 1.10 29.5 20 Amp 102 3.5 KW / 5.0 KW
59516.606 15,000 12.9 71.0 2.0 6.0 325 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW
* For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
12 AWG
Copper
ANALOG DUCTED INSTALLATION INSTRUCTIONS
up to 24’
SPECIFICATIONS
COOLING AMPS AMPS “ W. C. SUPPLIED 1 UNIT/ 2 UNITS
(BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE**
115V AC,
60 HZ., 1PH.
When sizing the generator, the tot al power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and
from lack of maintenance.
NO. CAPACIT Y RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STA TIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR
MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUM
59528.601 N/A 6.0 45.6 2.0 5.6 325 / 250 0.41 / 1.10 16.5 15 Amp 92 3.5 KW / 5.0 KW
59529.531 N/A 6.9 49.0 2.0 5.6 325 / 250 0.40 / 1.10 18.5 15 Amp 94 3.5 KW / 5.0 KW
59530.531 N/A 7.8 53.0 2.0 5.6 325 / 250 0.40 / 1.10 19.0 15 Amp 94 3.5 KW / 5.0 KW
59530.532 N/A 8.0 53.0 2.5 5.8 325 / 250 0.40 / 1.10 18.5 15 Amp 94 3.5 KW / 5.0 KW
59530.536 N/A 7.8 53.0 2.0 5.6 325 / 250 0.40 / 1.10 19.0 15 Amp 94 3.5 KW / 5.0 KW
59530.601 N/A 8.0 48.3 2.0 5.6 335/ 250 0.40 / 1.10 19.0 15 Amp 93 3.5 KW / 5.0 KW
59530.631 N/A 8.0 48.3 2.0 5.6 335 / 250 0.40 / 1.10 19.0 15 Amp 94 3.5 KW / 5.0 KW
59530.632 N/A 8.5 48.3 2.5 5.8 325 / 250 0.40 / 1.10 18.0 15 Amp 94 2.5 KW / 4.0 KW
600312.321 11,000 9.5 53.0 3.1 8.8 335 / 250 0.12 / 0.65 16.5 20 Amp 95 2.5 KW / 4.0 KW
600312.421 11,000 10.7 50.0 3.1 8.8 335 / 250 0.12 / 0.65 16.0 20 Amp 101 2.5 KW / 4.0 KW
600315.321 13,500 12.4 60.0 3.1 8.8 335 / 250 0.12 / 0.65 15.5 20 Amp 96 3.5 KW / 5.0 KW
600315.326 13,500 12.4 60.0 3.1 8.8 335 / 250 0.12 / 0.65 17.0 20 Amp 102 3.5 KW / 5.0 KW
600315.421 13,500 1 1.5 50.0 3.1 8.8 335 / 250 0.12 / 0.65 15.5 20 Amp 96 3.5 KW / 5.0 KW
4
* For wire lenghts over 24 ft. consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
ANALOG DUCTED INSTALLATION INSTRUCTIONS
REAR OF UNIT
14-1/4" x 14-1/4” (±1/8) OPENING
CAUTION
2. PRECAUTIONS
WARNING
!
Improper installation may damage equip­ment, could endanger life, cause serious injury and/or property damage.
A. Read Installation and Operating instructions carefully
before attempting to start your air conditioner/heat pump installation.
B. Dometic Corporation will not be liable for any dam-
ages or injury incurred due to failure in following these instructions.
C. Installation must comply with the National Electrical
Code and any State or Local Codes or regulations.
D. DO NOT add any devices or accessories to this air
conditioner/heat pump except those specifically authorized by Dometic.
E. This equipment must be serviced by qualified person-
nel and some states require these people to be licensed.
3. CHOOSING LOCATION FOR THE AIR CONDITIONER/HEAT PUMP
This air conditioner/heat pump is specifically designed for installation on the roof of a recreational vehicle (RV).
A. For One Unit Installation:
The air conditioner/heat pump should be mounted slightly forward of center (front to back) and centered from side to side.
B. For Two Unit Installations:
Install one air conditioner/heat pump one-third and one air conditioner/heat pump two-thirds from front of RV and centered from side to side.
It is preferred that the air conditioner/heat pump be installed on a relatively flat and level roof section measured with the RV parked on a level surface; however,
1. Up to an 8° slant to either side or front-to-back is acceptable on 600 Series Air Conditioners/heat pump.
2. Up to a 15° slant to either side or front-to-back is acceptable on 579, 590, 591 or 595 Series Air conditioners/heat pump.
AFTER LOCATION HAS BEEN SELECTED:
a.Check for obstructions in the area where air
conditioner/heat pump will be installed. See FIG. 1.
b. The roof must be designed to support 130
pounds when the RV is in motion. Normally 200 pound static load design will meet this require­ment.
It is the responsibility of the installer of this air conditioner/heat pump system to ensure structural integrity of the RV roof. Never cre­ate a low spot on the roof where water will collect. Water standing around the air con­ditioner/heat pump may leak into the interior causing damage to the product and the RV.
FIG. 1 AIR CONDITIONER/HEAT PUMP DIMENSIONS (On Top of Vehicle)
KEEP THIS AREA FREE OF OBSTRUCTIONS
579, 590, 591 & 595 SERIES
7-5/8”
5-1/4”
14-1/4" x 14-1/4” (±1/8) OPENING
7-5/8”
14-7/8”
600 SERIES
REAR OF UNIT
18"
5
ANALOG DUCTED INSTALLATION INSTRUCTIONS
4. AIR DISTRIBUTION SYSTEM SIZING & DESIGN
The Installer of this air conditioner/heat pump system must design the air distribution system for their particular application. Several requirements for this system MUST be met for the air conditioner/heat pump to operate properly. These requirements are as follows: A. The duct material must meet or exceed any agency or RVIA Standard that may be in existence at the time the RV is produced. B. All discharge air ducts must be properly insulated to prevent condensation from forming on their surfaces or adjacent surfaces
during operation of the air conditioner/heat pump. This insulation must be R-7 minimum.
C. Ducts and their joints must be sealed to prevent condensation from forming on adjacent surfaces during operation of the air
conditioner/heat pump. D. Return air openings must have 40 square inches minimum free area including the filter. E. Return air to the air conditioner/heat pump must be filtered to prevent dirt accumulation on air conditioner/heat pump cooling
surface.
CAUTION
It is the responsibility of the installer to in­sure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof struc­tural or ceiling damage due to improperly in­sulated, sealed or collapsed ductwork.
AIR DISTRIBUTION
DUCT SIZING & DESIGN CHART
Return Air Cover Model 3105007.XXX 3308120.XXX
3105935.XXX Genesis Air Filtration System
Roof Cavity Depth 2.0 In. Min. - 5-1/2 In. Max. 2.0 In. Min. - 5-1/2 In. Max. Duct Cross Sectional Area 21.0 Sq. In. Min. 32.0 Sq. In. Min.
Duct Size
Depth 1-1/2 In. Min. - 2-1/2 In. Max. 2.0 In. Min. - 2-1/2 In. Max. Width 7.0 In. Min. - 10.0 In. Max. 8.0 In. Min. - 10.0 In. Max. T ot al Duct Length 15.0 Ft. Min. - 40.0 Ft. Max. 15.0 Ft. Min. - 40.0 Ft. Max. Duct Length (short run) 1/3 T otal Duct Length 1/3 Total Duct Length
Register Requirements
Number Required Per Run 4 Min. 4 Min. Register Free Air Area 14.0 Sq. In. 14.0 Sq. In. Distance From Duct End 5.0 In. Min. - 8.0 In. Max. 5.0 In. Min. - 8.0 In. Max. Distance From Elbow 15.0 In. 15.0 In.
T ot al System St atic Air Pressure 0.55 - 0.90 In. W.C. 579 Series 0.55 - 0.90 In. W.C. 579 Series
Blower at High Speed, 0.40 - 1.10 In. W.C. 590, 591, 595 Series 0.40 - 1.10 In. W.C. 590, 591, 595 Series Filter & Grill In Place 0.12 - 0.65 In. W.C. 600 Series 0.12 - 0.65 In. W.C. 600 Series
Note: Duct sizes listed are inside dimensions.
6