Read these instructions carefully. These
instructions MUST stay with this product.
USA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
SERVICE CENTER &
DEALER LOCATIONS
Please Visit:
www.eDometic.com
INTRODUCTION
This air conditioner/heat pump (hereinafter referred to as “unit” or “product”) is designed and intended for installation on the
roof of a Recreational Vehicle (hereinafter referred to as RV) during the time it is manufactured.
Read these instructions and highlight the appropriate steps for your particular procedure before starting the installation.
This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly
installed, and properly functioning product.
Dometic Corporation reserves the right to modify appearances and specications without notice.
IMPORTANT SAFETY INSTRUCTIONS ............................................................................................................................3
A. Recognize Safety Information ...................................................................................................................................3
B. Understand Signal Words ..........................................................................................................................................3
C. Supplemental Directives ............................................................................................................................................3
D. General Safety Messages .........................................................................................................................................3
A. Table - Unit Data ........................................................................................................................................................4
B. Roof Requirements .................................................................................................................................................... 4
C. Table - Air Distribution Duct Sizing & Design .............................................................................................................5
A. Choosing Proper Location For Unit ...........................................................................................................................5
B. Roof Preparation .......................................................................................................................................................6
C. Air Distribution Duct Sizing & Design ........................................................................................................................7
D. Wiring Requirements .................................................................................................................................................8
E. Choosing Thermostat Location ..................................................................................................................................8
F. Thermostat Installation .............................................................................................................................................9
G. Placing Unit On Roof ................................................................................................................................................. 9
H. Installation Preparation ............................................................................................................................................ 10
I. LCD SZ System Low Voltage Wire Connections .....................................................................................................12
J. Upgrading from Bi-Metal Thermostat to SZ LCD Thermostat .................................................................................12
K. Installing Return Air Cover .......................................................................................................................................13
GENERAL INFORMATION ................................................................................................................................................14
A. Frost Formation On Cooling Coil ............................................................................................................................. 14
B. Heat Gain ................................................................................................................................................................14
C. Condensation ..........................................................................................................................................................14
D. Air Distribution ......................................................................................................................................................... 14
A. Simple RV Wiring Diagram ......................................................................................................................................15
B. Unit Wiring Diagrams ............................................................................................................................................... 16
DOCUMENT SYMBOLS
Indicates additional information that is NOT related
to physical injury.
Indicates step-by-step instructions.
2
IMPORTANT SAFETY INSTRUCTIONS
This manual has safety information and instructions to help
users eliminate or reduce the risk of accidents and injuries.
A. Recognize Safety Information
This is the safety alert symbol. It is used to
alert you to potential physical injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
B. Understand Signal Words
A signal word will identify safety messages and
property damage messages, and will indicate the
degree or level of hazard seriousness.
indicates a hazardous situation that,
if NOT avoided, could result in death or serious injury.
indicates a hazardous situation that,
if NOT avoided, could result in minor or moderate
injury.
is used to address practices NOT
related to physical injury.
C. Supplemental Directives
Read and follow all safety information and
instructions to avoid possible injury or death.
Read and understand these instructions before [installing / using / servicing / performing
maintenance on] this product.
Incorrect [installation / operation / servicing /
maintaining] of this product can lead to serious injury. Follow all instructions.
The installation MUST comply with all applicable local or national codes, including
the latest edition of the following standards:
U.S.A.
● ANSI/NFPA70, National Electrical Code
(NEC)
● ANSI/NFPA 1192, Recreational Vehicles
Code
CANADA
● CSA C22.1, Parts l & ll, Canadian Electri-
cal Code
● CSA Z240 RV Series, Recreational
Vehicles
D. General Safety Messages
Failure to obey the following warnings could result in death or serious injury:
● This product MUST be [installed / serviced] by a
qualied service technician.
● Do NOT modify this product in any way. Modica-
tion can be extremely hazardous.
* For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements
●A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this
unit. This opening is part of the return air system of the unit and MUST be nished in accordance with NFPA 1192.
●Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
●Minimum of 2 inches and maximum of 5-1/2 inches distance between roof to ceiling of RV.